Deutz · CAN communication and shutdown

Deutz CAN messages: torque and speed requests, wastegate, EGR and throttle actuators fault codes

Control messages the EMR4 exchanges over CAN: torque and speed requests from the machine controller (SPN 520, 898, 523605 and related), and the messages with the smart actuators for the wastegate, EGR valve, intake throttle and exhaust flaps. Each code names the message and whether it timed out or arrived wrong.

FaultCheckSPN 520FMI 9Deutz · Machine - CAN torque rotation speed control
Plug the service tool in hereDiagnosticport, 9-pin

Where to read it

Read the active and stored faults with Deutz SerDia (or the machine maker's diagnostic tool) on the engine diagnostic plug.

What do these codes mean?

Deutz codes SPN 520 FMI 9 to SPN 524125 FMI 9 are all about the cAN messages: torque and speed requests, wastegate, EGR and throttle actuators. Most are lost message faults; none needs an immediate stop. Start with this check: read the status of the machine controller or actuator first, since it is the sender.

How urgent are they?

None of the 24 codes here means stop now; all 24 can wait until the shift ends, but find the cause before the next one.

  • Check soon24

What should I check first?

Read the status of the machine controller or actuator first, since it is the sender

Shared checks

24 of 24

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Machine - CAN torque rotation speed control11 codes

    • Deutz SPN 520 FMI 9Machine - CAN torque rotation speed control: Abnormal update rate timeout

      The EMR4 reports a timeout of the CAN torque and speed control message from the machine.· Lost message
      Check soon

      Causes

      • Machine controller not sending the message
      • CAN wiring fault
      • Message ID mismatch after software change

      Checks

      1. 1Check the machine controller is powered and running, since a dead controller sends nothing
      2. 2Measure CAN-H to CAN-L resistance at the diagnostic plug and check the terminators
      3. 3Use SerDia to see whether the speed and torque request arrives at all
      4. 4Check the CAN wires for chafing and loose connectors
      5. 5Watch the requested torque and speed in SerDia; if they freeze or drop to a default the message has stopped.
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

    • Deutz SPN 523605 FMI 9Machine - CAN torque rotation speed control: Abnormal update rate timeout

      Same fault as SPN 520 FMI 9 for the CAN torque rotation speed control message.· Lost message
      Check soon

      Causes

      • Machine controller not sending the message
      • CAN wiring fault

      Checks

      1. 1Watch the requested torque and speed in SerDia; if they freeze or drop to a default the message has stopped.
      2. 2Check the machine controller is powered and running, since a dead controller sends nothing
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

    • Deutz SPN 523606 FMI 9Machine - CAN torque rotation speed control: Abnormal update rate timeout

      Same fault as SPN 520 FMI 9 for the CAN torque rotation speed control message.· Lost message
      Check soon

      Causes

      • Machine controller not sending the message
      • CAN wiring fault

      Checks

      1. 1Watch the requested torque and speed in SerDia; if they freeze or drop to a default the message has stopped.
      2. 2Check the machine controller is powered and running, since a dead controller sends nothing
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

    • Deutz SPN 523766 FMI 9Machine - CAN torque rotation speed control: Abnormal update rate timeout

      Same fault as SPN 520 FMI 9 for the CAN torque rotation speed control message.· Lost message
      Check soon

      Causes

      • Machine controller not sending the message
      • CAN wiring fault

      Checks

      1. 1Watch the requested torque and speed in SerDia; if they freeze or drop to a default the message has stopped.
      2. 2Check the machine controller is powered and running, since a dead controller sends nothing
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

    • Deutz SPN 523767 FMI 9Machine - CAN torque rotation speed control: Abnormal update rate timeout

      Same fault as SPN 520 FMI 9 for the CAN torque rotation speed control message.· Lost message
      Check soon

      Causes

      • Machine controller not sending the message
      • CAN wiring fault

      Checks

      1. 1Watch the requested torque and speed in SerDia; if they freeze or drop to a default the message has stopped.
      2. 2Check the machine controller is powered and running, since a dead controller sends nothing
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

    • Deutz SPN 523768 FMI 9Machine - CAN torque rotation speed control: Abnormal update rate timeout

      Same fault as SPN 520 FMI 9 for the CAN torque rotation speed control message.· Lost message
      Check soon

      Causes

      • Machine controller not sending the message
      • CAN wiring fault

      Checks

      1. 1Watch the requested torque and speed in SerDia; if they freeze or drop to a default the message has stopped.
      2. 2Check the machine controller is powered and running, since a dead controller sends nothing
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

    • Deutz SPN 523769 FMI 9Machine - CAN torque rotation speed control: Abnormal update rate timeout

      Same fault as SPN 520 FMI 9 for the CAN torque rotation speed control message.· Lost message
      Check soon

      Causes

      • Machine controller not sending the message
      • CAN wiring fault

      Checks

      1. 1Watch the requested torque and speed in SerDia; if they freeze or drop to a default the message has stopped.
      2. 2Check the machine controller is powered and running, since a dead controller sends nothing
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

    • Deutz SPN 523776 FMI 9Machine - CAN torque rotation speed control: Abnormal update rate timeout

      Same fault as SPN 520 FMI 9 for the CAN torque rotation speed control message.· Lost message
      Check soon

      Causes

      • Machine controller not sending the message
      • CAN wiring fault

      Checks

      1. 1Watch the requested torque and speed in SerDia; if they freeze or drop to a default the message has stopped.
      2. 2Check the machine controller is powered and running, since a dead controller sends nothing
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

    • Deutz SPN 523777 FMI 9Machine - CAN torque rotation speed control: Abnormal update rate timeout

      Same fault as SPN 520 FMI 9 for the CAN torque rotation speed control message.· Lost message
      Check soon

      Causes

      • Machine controller not sending the message
      • CAN wiring fault

      Checks

      1. 1Watch the requested torque and speed in SerDia; if they freeze or drop to a default the message has stopped.
      2. 2Check the machine controller is powered and running, since a dead controller sends nothing
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

    • Deutz SPN 523778 FMI 9Machine - CAN torque rotation speed control: Abnormal update rate timeout

      Same fault as SPN 520 FMI 9 for the CAN torque rotation speed control message.· Lost message
      Check soon

      Causes

      • Machine controller not sending the message
      • CAN wiring fault

      Checks

      1. 1Watch the requested torque and speed in SerDia; if they freeze or drop to a default the message has stopped.
      2. 2Check the machine controller is powered and running, since a dead controller sends nothing
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

    • Deutz SPN 523779 FMI 9Machine - CAN torque rotation speed control: Abnormal update rate timeout

      Same fault as SPN 520 FMI 9 for the CAN torque rotation speed control message.· Lost message
      Check soon

      Causes

      • Machine controller not sending the message
      • CAN wiring fault

      Checks

      1. 1Watch the requested torque and speed in SerDia; if they freeze or drop to a default the message has stopped.
      2. 2Check the machine controller is powered and running, since a dead controller sends nothing
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Machine - Externally requested engine rotation speed1 code

    • Deutz SPN 898 FMI 9Machine - Externally requested engine rotation speed: Abnormal update rate timeout

      The EMR4 reports a timeout of the externally requested engine speed message.· Lost message
      Check soon

      Causes

      • Machine controller stopped sending the speed request
      • CAN wiring fault
      • Power loss on the machine controller

      Checks

      1. 1Check the supply and ground of the machine controller that sends the speed request
      2. 2Measure CAN-H to CAN-L resistance at the diagnostic plug and check the terminators
      3. 3Watch for the speed request message in SerDia while the machine asks for a speed change
      4. 4Check the CAN wires for chafing and loose connectors
      5. 5Check the source of the speed request and its CAN wires.
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Engine - CAN Wastegate actuator2 codes

    • Deutz SPN 523788 FMI 0Engine - CAN Wastegate actuator: Reading too high· most severe

      The EMR4 rates the CAN Wastegate actuator (exchanged with the wastegate actuator over CAN) as above its allowed operating range, at the most severe level.· Real condition
      Check soon

      Causes

      • The monitored condition is really above its limit, for example from overload or a blockage
      • Signal or part drifting high with age

      Checks

      1. 1Read the CAN Wastegate actuator value in SerDia and compare it with an independent measurement before replacing parts
      2. 2Look for the real cause of an excessive value, such as a restriction or an overloaded function
      3. 3Read the wastegate position in SerDia and compare it with the target.
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Engine - CAN Wastegate actuator - Data above normal operational range (Most severe level)

    • Deutz SPN 523788 FMI 12Engine - CAN Wastegate actuator: Bad device or component

      The EMR4 judges the CAN Wastegate actuator (exchanged with the wastegate actuator over CAN) to be a bad device.· Part or controller
      Check soon

      Causes

      • Internal failure of the part or its electronics
      • Water, soot or dirt inside the part

      Checks

      1. 1Read the CAN Wastegate actuator status in SerDia and run any available actuator or component test
      2. 2Check supply voltage and ground at the connector with the key on to confirm it is powered
      3. 3Check the supply and ground at the wastegate actuator, then swap it with a known good one.
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

      Source wording:Engine - CAN Wastegate actuator - Bad intelligent device or component

  • Engine - CAN EGR actuator4 codes

    • Deutz SPN 524106 FMI 9Engine - CAN EGR actuator: Abnormal update rate timeout

      Same fault as SPN 524108 FMI 9 for the CAN EGR actuator message.· Lost message
      Check soon

      Causes

      • CAN wire open, shorted or a connector loose on the path to the sender
      • Sender not powered, in reset or switched off

      Checks

      1. 1Check the heat damage on the CAN stub and plug of the EGR actuator.
      2. 2Check the supply and ground of the sending control unit with the key on
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

    • Deutz SPN 524107 FMI 9Engine - CAN EGR actuator: Abnormal update rate timeout

      Same fault as SPN 524108 FMI 9 for the CAN EGR actuator message.· Lost message
      Check soon

      Causes

      • CAN wire open, shorted or a connector loose on the path to the sender
      • Sender not powered, in reset or switched off

      Checks

      1. 1Check the heat damage on the CAN stub and plug of the EGR actuator.
      2. 2Check the supply and ground of the sending control unit with the key on
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

    • Deutz SPN 524108 FMI 9Engine - CAN EGR actuator: Abnormal update rate timeout

      The EMR4 did not receive the CAN EGR actuator (exchanged with the actuator over CAN) within the expected time.· Lost message
      Check soon

      Causes

      • CAN wire open, shorted or a connector loose on the path to the sender
      • Sender not powered, in reset or switched off

      Checks

      1. 1Check the supply and ground of the sending control unit with the key on
      2. 2Measure the bus resistance with the key off and look for a missing terminating resistor
      3. 3Check the heat damage on the CAN stub and plug of the EGR actuator.
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

    • Deutz SPN 524109 FMI 9Engine - CAN EGR actuator: Abnormal update rate timeout

      Same fault as SPN 524108 FMI 9 for the CAN EGR actuator message.· Lost message
      Check soon

      Causes

      • CAN wire open, shorted or a connector loose on the path to the sender
      • Sender not powered, in reset or switched off

      Checks

      1. 1Check the heat damage on the CAN stub and plug of the EGR actuator.
      2. 2Check the supply and ground of the sending control unit with the key on
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Engine - Exhaust throttle flap1 code

    • Deutz SPN 524110 FMI 9Engine - Exhaust throttle flap: Abnormal update rate timeout

      The EMR4 did not receive the exhaust throttle flap (exchanged with the actuator over CAN) within the expected time.· Lost message
      Check soon

      Causes

      • CAN wire open, shorted or a connector loose on the path to the sender
      • Sender not powered, in reset or switched off

      Checks

      1. 1Check the supply and ground of the sending control unit with the key on
      2. 2Measure the bus resistance with the key off and look for a missing terminating resistor
      3. 3Check that the exhaust throttle flap moves freely and has supply.
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Engine - Exhaust brake flap1 code

    • Deutz SPN 524111 FMI 9Engine - Exhaust brake flap: Abnormal update rate timeout

      The EMR4 did not receive the exhaust brake flap (exchanged with the actuator over CAN) within the expected time.· Lost message
      Check soon

      Causes

      • CAN wire open, shorted or a connector loose on the path to the sender
      • Sender not powered, in reset or switched off

      Checks

      1. 1Check the supply and ground of the sending control unit with the key on
      2. 2Measure the bus resistance with the key off and look for a missing terminating resistor
      3. 3Check that the exhaust brake flap moves freely and has supply.
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Engine - CAN throttle valve2 codes

    • Deutz SPN 524112 FMI 9Engine - CAN throttle valve: Abnormal update rate timeout

      The EMR4 did not receive the CAN throttle valve (exchanged with the actuator over CAN) within the expected time.· Lost message
      Check soon

      Causes

      • CAN wire open, shorted or a connector loose on the path to the sender
      • Sender not powered, in reset or switched off

      Checks

      1. 1Check the supply and ground of the sending control unit with the key on
      2. 2Measure the bus resistance with the key off and look for a missing terminating resistor
      3. 3Check supply and ground at the intake throttle valve and its CAN plug.
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

    • Deutz SPN 524113 FMI 9Engine - CAN throttle valve: Abnormal update rate timeout

      Same fault as SPN 524112 FMI 9 for the CAN throttle valve message.· Lost message
      Check soon

      Causes

      • CAN wire open, shorted or a connector loose on the path to the sender
      • Sender not powered, in reset or switched off

      Checks

      1. 1Check supply and ground at the intake throttle valve and its CAN plug.
      2. 2Check the supply and ground of the sending control unit with the key on
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Engine - CAN wastegate actuator2 codes

    • Deutz SPN 524121 FMI 9Engine - CAN wastegate actuator: Abnormal update rate timeout

      The EMR4 did not receive the CAN wastegate actuator (exchanged with the wastegate actuator over CAN) within the expected time.· Lost message
      Check soon

      Causes

      • CAN wire open, shorted or a connector loose on the path to the sender
      • Sender not powered, in reset or switched off

      Checks

      1. 1Check the supply and ground of the sending control unit with the key on
      2. 2Measure the bus resistance with the key off and look for a missing terminating resistor
      3. 3Check the supply, the CAN stub and the heat shield of the wastegate actuator.
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

    • Deutz SPN 524125 FMI 9Engine - CAN wastegate actuator: Abnormal update rate timeout

      Same fault as SPN 524121 FMI 9 for the CAN wastegate actuator message.· Lost message
      Check soon

      Causes

      • CAN wire open, shorted or a connector loose on the path to the sender
      • Sender not powered, in reset or switched off

      Checks

      1. 1Check the supply, the CAN stub and the heat shield of the wastegate actuator.
      2. 2Check the supply and ground of the sending control unit with the key on
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

Shared checks

Checks, in order

  1. 1Read the status of the machine controller or actuator first, since it is the sender
  2. 2Measure CAN high to CAN low resistance with the key off and compare it with the machine wiring diagram
  3. 3Wiggle the CAN harness near the connector while watching the message status in SerDia
  4. 4Measure supply and ground at the actuator connector with the key on
  5. 5Look at the requested speed and torque in SerDia and see whether they drop to a default when the code is active

Causes

  • Machine controller or smart actuator not sending because it is in a fault state or has lost its supply
  • CAN high or CAN low wire open, chafed or shorted, or a terminating resistor missing
  • Connector with a pushed-back pin or water inside
  • Actuator stuck with soot and reporting a fault on the bus

Most codes here: lost message (22 of 24)

Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

When to stop

You'll notice: A warning lamp or limited function.

Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.