Deutz · CAN communication and shutdown

Deutz CAN messages from the aftertreatment controller: exhaust inlet, DPF, DOC, SCR and DEF fault codes

Messages that the exhaust aftertreatment controller and the SCR and DEF tank units send to the EMR4 over CAN: the exhaust inlet messages, the DPF and DOC filter and catalyst data used for regeneration, and the SCR and DEF messages (dosing, heaters, tank, level, quality). Each code names the message and whether it is missing or implausible.

FaultCheckSPN 523803FMI 9Deutz · CAN messages from the aftertreatment controller: exhaust inlet, DPF, DOC, SCR and DEF
Plug the service tool in hereDiagnosticport, 9-pin

Where to read it

Read the active and stored faults with Deutz SerDia (or the machine maker's diagnostic tool) on the engine diagnostic plug.

What do these codes mean?

Deutz codes SPN 523803 FMI 9 to SPN 524262 FMI 8 are all about the cAN messages from the aftertreatment controller: exhaust inlet, DPF, DOC, SCR and DEF. Most are lost message faults; none needs an immediate stop. Start with this check: check the fuse and key-on supply of the aftertreatment or SCR control unit before looking at the bus.

How urgent are they?

None of the 25 codes here means stop now; all 25 can wait until the shift ends, but find the cause before the next one.

  • Check soon25

What should I check first?

Check the fuse and key-on supply of the aftertreatment or SCR control unit before looking at the bus

Shared checks

25 of 25

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • CAN exhaust inlet6 codes

    • Deutz SPN 523938 FMI 9CAN exhaust inlet: Abnormal update rate timeout

      The EMR4 did not receive the CAN exhaust inlet (sent over CAN from the exhaust aftertreatment controller) within the expected time.· Lost message
      Check soon

      Causes

      • CAN wire open, shorted or a connector loose on the path to the sender
      • Sender not powered, in reset or switched off
      • Exhaust inlet sensor module damaged by heat at the aftertreatment inlet flange

      Checks

      1. 1Check the supply and ground of the sending control unit with the key on
      2. 2Measure the bus resistance with the key off and look for a missing terminating resistor
      3. 3Check the exhaust inlet sensor module plugs and the CAN stub near the exhaust.
      4. 4Wiggle the exhaust inlet sensor module plug and watch whether the message status drops out.
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

    • Deutz SPN 523939 FMI 9CAN exhaust inlet: Abnormal update rate timeout

      Same fault as SPN 523938 FMI 9 for the CAN exhaust inlet message.· Lost message
      Check soon

      Causes

      • CAN wire open, shorted or a connector loose on the path to the sender
      • Sender not powered, in reset or switched off

      Checks

      1. 1Check the exhaust inlet sensor module plugs and the CAN stub near the exhaust.
      2. 2Check the supply and ground of the sending control unit with the key on
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

    • Deutz SPN 523940 FMI 9CAN exhaust inlet: Abnormal update rate timeout

      Same fault as SPN 523938 FMI 9 for the CAN exhaust inlet message.· Lost message
      Check soon

      Causes

      • CAN wire open, shorted or a connector loose on the path to the sender
      • Sender not powered, in reset or switched off

      Checks

      1. 1Check the exhaust inlet sensor module plugs and the CAN stub near the exhaust.
      2. 2Check the supply and ground of the sending control unit with the key on
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

    • Deutz SPN 523941 FMI 9CAN exhaust inlet: Abnormal update rate timeout

      Same fault as SPN 523938 FMI 9 for the CAN exhaust inlet message.· Lost message
      Check soon

      Causes

      • CAN wire open, shorted or a connector loose on the path to the sender
      • Sender not powered, in reset or switched off

      Checks

      1. 1Check the exhaust inlet sensor module plugs and the CAN stub near the exhaust.
      2. 2Check the supply and ground of the sending control unit with the key on
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

    • Deutz SPN 523942 FMI 9CAN exhaust inlet: Abnormal update rate timeout

      Same fault as SPN 523938 FMI 9 for the CAN exhaust inlet message.· Lost message
      Check soon

      Causes

      • CAN wire open, shorted or a connector loose on the path to the sender
      • Sender not powered, in reset or switched off

      Checks

      1. 1Check the exhaust inlet sensor module plugs and the CAN stub near the exhaust.
      2. 2Check the supply and ground of the sending control unit with the key on
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

    • Deutz SPN 523943 FMI 9CAN exhaust inlet: Abnormal update rate timeout

      Same fault as SPN 523938 FMI 9 for the CAN exhaust inlet message.· Lost message
      Check soon

      Causes

      • CAN wire open, shorted or a connector loose on the path to the sender
      • Sender not powered, in reset or switched off

      Checks

      1. 1Check the exhaust inlet sensor module plugs and the CAN stub near the exhaust.
      2. 2Check the supply and ground of the sending control unit with the key on
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • CAN return actuator1 code

    • Deutz SPN 524029 FMI 2CAN return actuator: Erratic reading

      The EMR4 receives the CAN return actuator (sent over CAN by the SCR control unit) but the content is erratic or implausible.· Erratic or implausible
      Check soon

      Causes

      • Sender sending a faulty value because of its own sensor fault
      • Electrical noise on the CAN bus
      • DEF return valve sticking or leaking so its reported position is wrong

      Checks

      1. 1Read the sender status and values in SerDia and compare them with a second source
      2. 2Inspect the CAN wiring for chafing and poor connectors
      3. 3Check the return valve and its circuit and plug.
      4. 4Check the DEF return valve for sticking and its plug for crystals.
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Exhaust aftertreatment - CAN return actuator - Data erratic intermittent or incorrect

  • CAN DPF5 codes

    • Deutz SPN 524099 FMI 9CAN DPF: Abnormal update rate timeout

      The EMR4 did not receive the CAN DPF (sent over CAN by the aftertreatment controller) within the expected time.· Lost message
      Check soon

      Causes

      • CAN wire open, shorted or a connector loose on the path to the sender
      • Sender not powered, in reset or switched off
      • DPF differential pressure module plug filled with soot or water

      Checks

      1. 1Check the supply and ground of the sending control unit with the key on
      2. 2Measure the bus resistance with the key off and look for a missing terminating resistor
      3. 3Check the DPF differential pressure module plug.
      4. 4Read the DPF soot load and differential pressure in SerDia to see whether they still update.
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

    • Deutz SPN 524100 FMI 9CAN DPF: Abnormal update rate timeout

      Same fault as SPN 524099 FMI 9 for the CAN DPF message.· Lost message
      Check soon

      Causes

      • CAN wire open, shorted or a connector loose on the path to the sender
      • Sender not powered, in reset or switched off

      Checks

      1. 1Check the DPF differential pressure module plug.
      2. 2Check the supply and ground of the sending control unit with the key on
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

    • Deutz SPN 524101 FMI 9CAN DPF: Abnormal update rate timeout

      Same fault as SPN 524099 FMI 9 for the CAN DPF message.· Lost message
      Check soon

      Causes

      • CAN wire open, shorted or a connector loose on the path to the sender
      • Sender not powered, in reset or switched off

      Checks

      1. 1Check the DPF differential pressure module plug.
      2. 2Check the supply and ground of the sending control unit with the key on
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

    • Deutz SPN 524104 FMI 9CAN DPF: Abnormal update rate timeout

      Same fault as SPN 524099 FMI 9 for the CAN DPF message.· Lost message
      Check soon

      Causes

      • CAN wire open, shorted or a connector loose on the path to the sender
      • Sender not powered, in reset or switched off

      Checks

      1. 1Check the DPF differential pressure module plug.
      2. 2Check the supply and ground of the sending control unit with the key on
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

    • Deutz SPN 524124 FMI 9CAN DPF: Abnormal update rate timeout

      Same fault as SPN 524099 FMI 9 for the CAN DPF message.· Lost message
      Check soon

      Causes

      • CAN wire open, shorted or a connector loose on the path to the sender
      • Sender not powered, in reset or switched off

      Checks

      1. 1Check the DPF differential pressure module plug.
      2. 2Check the supply and ground of the sending control unit with the key on
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • CAN DOC1 code

    • Deutz SPN 524114 FMI 9CAN DOC: Abnormal update rate timeout

      The EMR4 did not receive the CAN DOC (sent over CAN by the aftertreatment controller) within the expected time.· Lost message
      Check soon

      Causes

      • CAN wire open, shorted or a connector loose on the path to the sender
      • Sender not powered, in reset or switched off
      • DOC temperature sensor wiring burnt where it passes the catalyst housing

      Checks

      1. 1Check the supply and ground of the sending control unit with the key on
      2. 2Measure the bus resistance with the key off and look for a missing terminating resistor
      3. 3Check the DOC temperature sensor plugs.
      4. 4Read the DOC temperatures in SerDia and see whether they still update.
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • CAN service1 code

    • Deutz SPN 524115 FMI 9CAN service: Abnormal update rate timeout

      The EMR4 did not receive the CAN service (sent over CAN by the SCR control unit) within the expected time.· Lost message
      Check soon

      Causes

      • CAN wire open, shorted or a connector loose on the path to the sender
      • Sender not powered, in reset or switched off
      • Service flag set by a recent workshop session and never cleared

      Checks

      1. 1Check the supply and ground of the sending control unit with the key on
      2. 2Measure the bus resistance with the key off and look for a missing terminating resistor
      3. 3Read the service state of the aftertreatment controller in SerDia.
      4. 4Read the service state of the aftertreatment unit and check for open service flags.
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • CAN DEF tank1 code

    • Deutz SPN 524116 FMI 9CAN DEF tank: Abnormal update rate timeout

      The EMR4 did not receive the CAN DEF tank (sent over CAN by the SCR control unit) within the expected time.· Lost message
      Check soon

      Causes

      • CAN wire open, shorted or a connector loose on the path to the sender
      • Sender not powered, in reset or switched off
      • DEF tank unit plug eaten by spilled DEF during refilling

      Checks

      1. 1Check the supply and ground of the sending control unit with the key on
      2. 2Measure the bus resistance with the key off and look for a missing terminating resistor
      3. 3Check the DEF tank unit connector for crystals and supply.
      4. 4Read the DEF tank level and temperature in SerDia and see whether they still update.
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • CAN DEF heater1 code

    • Deutz SPN 524117 FMI 9CAN DEF heater: Abnormal update rate timeout

      The EMR4 did not receive the CAN DEF heater (sent over CAN by the SCR control unit) within the expected time.· Lost message
      Check soon

      Causes

      • CAN wire open, shorted or a connector loose on the path to the sender
      • Sender not powered, in reset or switched off
      • DEF tank heater feed fuse open, silencing the heater status message

      Checks

      1. 1Check the supply and ground of the sending control unit with the key on
      2. 2Measure the bus resistance with the key off and look for a missing terminating resistor
      3. 3Check the DEF tank unit heater plug and supply.
      4. 4Read the DEF tank level and temperature in SerDia and see whether they still update.
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • CAN DPF regeneration1 code

    • Deutz SPN 524118 FMI 9CAN DPF regeneration: Abnormal update rate timeout

      The EMR4 did not receive the CAN DPF regeneration (sent over CAN by the aftertreatment controller) within the expected time.· Lost message
      Check soon

      Causes

      • CAN wire open, shorted or a connector loose on the path to the sender
      • Sender not powered, in reset or switched off
      • Regeneration manager of the aftertreatment unit stalled after a failed burn

      Checks

      1. 1Check the supply and ground of the sending control unit with the key on
      2. 2Measure the bus resistance with the key off and look for a missing terminating resistor
      3. 3Read the regeneration state in SerDia and check what blocks it.
      4. 4Read the DPF soot load and differential pressure in SerDia to see whether they still update.
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • CAN SCR heater diagnostic1 code

    • Deutz SPN 524120 FMI 9CAN SCR heater diagnostic: Abnormal update rate timeout

      The EMR4 did not receive the CAN SCR heater diagnostic (sent over CAN by the SCR control unit) within the expected time.· Lost message
      Check soon

      Causes

      • CAN wire open, shorted or a connector loose on the path to the sender
      • Sender not powered, in reset or switched off
      • SCR heater diagnostic wire chafed against the DEF line clamp

      Checks

      1. 1Check the supply and ground of the sending control unit with the key on
      2. 2Measure the bus resistance with the key off and look for a missing terminating resistor
      3. 3Check the SCR heater connector.
      4. 4Read the SCR dosing state in SerDia and see whether it still updates.
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • CAN DEF quality1 code

    • Deutz SPN 524122 FMI 9CAN DEF quality: Abnormal update rate timeout

      The EMR4 did not receive the CAN DEF quality (sent over CAN by the SCR control unit) within the expected time.· Lost message
      Check soon

      Causes

      • CAN wire open, shorted or a connector loose on the path to the sender
      • Sender not powered, in reset or switched off
      • DEF quality sensor contaminated, so its module stops answering

      Checks

      1. 1Check the supply and ground of the sending control unit with the key on
      2. 2Measure the bus resistance with the key off and look for a missing terminating resistor
      3. 3Check the DEF quality sensor plug in the tank unit.
      4. 4Read the DEF tank level and temperature in SerDia and see whether they still update.
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • CAN SCR heater control1 code

    • Deutz SPN 524123 FMI 9CAN SCR heater control: Abnormal update rate timeout

      The EMR4 did not receive the CAN SCR heater control (sent over CAN by the SCR control unit) within the expected time.· Lost message
      Check soon

      Causes

      • CAN wire open, shorted or a connector loose on the path to the sender
      • Sender not powered, in reset or switched off
      • SCR heater driver in the control unit switched off by its own overcurrent protection

      Checks

      1. 1Check the supply and ground of the sending control unit with the key on
      2. 2Measure the bus resistance with the key off and look for a missing terminating resistor
      3. 3Check the SCR control unit supply.
      4. 4Read the SCR dosing state in SerDia and see whether it still updates.
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • CAN DEF quality sensor1 code

    • Deutz SPN 524152 FMI 2CAN DEF quality sensor: Erratic reading

      The EMR4 receives the CAN DEF quality sensor (sent over CAN by the SCR control unit) but the content is erratic or implausible.· Erratic or implausible
      Check soon

      Causes

      • Sender sending a faulty value because of its own sensor fault
      • Electrical noise on the CAN bus
      • DEF quality sensor reporting a concentration outside any possible value because the element is fouled

      Checks

      1. 1Read the sender status and values in SerDia and compare them with a second source
      2. 2Inspect the CAN wiring for chafing and poor connectors
      3. 3Check the DEF quality sensor plug in the tank unit.
      4. 4Read the DEF tank level and temperature in SerDia and see whether they still update.
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Exhaust aftertreatment - CAN DEF quality sensor - Data erratic intermittent or incorrect

  • DEF tank level and temperature1 code

    • Deutz SPN 524153 FMI 2DEF tank level and temperature: Erratic reading

      The EMR4 receives the DEF tank level and temperature (sent over CAN by the SCR control unit) but the content is erratic or implausible.· Erratic or implausible
      Check soon

      Causes

      • Sender sending a faulty value because of its own sensor fault
      • Electrical noise on the CAN bus
      • Tank level float or temperature element sending an impossible pair of values

      Checks

      1. 1Read the sender status and values in SerDia and compare them with a second source
      2. 2Inspect the CAN wiring for chafing and poor connectors
      3. 3Compare the displayed level and temperature with the real tank.
      4. 4Fill or drain the tank slightly and watch whether the level value follows.
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Exhaust aftertreatment - DEF tank level and temperature - Data erratic intermittent or incorrect

  • CAN SCR2 codes

    • Deutz SPN 524184 FMI 9CAN SCR: Abnormal update rate timeout

      The EMR4 did not receive the CAN SCR (sent over CAN by the SCR control unit) within the expected time.· Lost message
      Check soon

      Causes

      • CAN wire open, shorted or a connector loose on the path to the sender
      • Sender not powered, in reset or switched off
      • SCR control unit reset by a failed dosing self-test

      Checks

      1. 1Check the supply and ground of the sending control unit with the key on
      2. 2Measure the bus resistance with the key off and look for a missing terminating resistor
      3. 3Check the SCR control unit supply and plug.
      4. 4Read the SCR dosing state in SerDia and see whether it still updates.
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

    • Deutz SPN 524262 FMI 8CAN SCR: Abnormal frequency / pulse width

      The EMR4 sees the CAN SCR (sent over CAN by the SCR control unit) arriving with an abnormal rate or timing.· Erratic or implausible
      Check soon

      Causes

      • Heavy load or errors on the CAN bus
      • Sender running at a wrong rate
      • SCR message sent at the wrong rate by a unit running an old software release

      Checks

      1. 1Read the CAN bus load in the service tool, if available
      2. 2Inspect the CAN wiring and connectors for faults
      3. 3Check the SCR control unit for resets and the bus for overload.
      4. 4Read the SCR dosing state in SerDia and see whether it still updates.
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Exhaust aftertreatment - CAN SCR - Abnormal frequency or pulse width or period

  • Other codes1 code

    • Deutz SPN 523803 FMI 9- Abnormal update rate timeout

      The EMR4 did not receive the exhaust aftertreatment (sent over CAN from the exhaust aftertreatment controller) within the expected time.· Lost message
      Check soon

      Causes

      • CAN wire open, shorted or a connector loose on the path to the sender
      • Sender not powered, in reset or switched off
      • Aftertreatment control unit in a software reset after a voltage dip

      Checks

      1. 1Check the supply and ground of the sending control unit with the key on
      2. 2Measure the bus resistance with the key off and look for a missing terminating resistor
      3. 3Check the aftertreatment control unit supply and its CAN stub first.
      4. 4Compare the code with the neighbouring exhaust inlet codes to see which sensor module it belongs to.
      Module AModule BCAN HCAN L120 Ω120 Ω
      Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

      Meter test

      Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

      Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

Shared checks

Checks, in order

  1. 1Check the fuse and key-on supply of the aftertreatment or SCR control unit before looking at the bus
  2. 2Look for DEF crystals or green deposits at the dosing module and DEF tank connectors
  3. 3Read the DPF, SCR and DEF status in SerDia and see which message is stale
  4. 4Compare the software and dataset versions of the control unit and the EMR4
  5. 5Wiggle the harness at the tank unit and exhaust brackets while watching the message status

Causes

  • Aftertreatment, SCR or DEF control unit without supply because of a blown fuse or a failed key-on feed
  • Sensor or tank module plug unplugged or corroded, with DEF crystals on the connector
  • CAN stub chafed on an exhaust bracket or burnt by exhaust heat
  • Software or dataset of the control unit not matching the EMR4

Most codes here: lost message (21 of 25)

Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

When to stop

You'll notice: A warning lamp or limited function.

Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.