Detroit · Injectors
Detroit Amplifier control valve circuits fault codes
The amplifier control valve works with the needle control valve in each Detroit injector to build the injection pressure. SPN 3659 to 3664 name cylinders 1 to 6, and SPN 4257 and 4258 are shorts affecting a bank of three cylinders.
Where to read it
Connect a Detroit-capable diagnostic tool (Diagnostic Link or a compatible scan tool) to the vehicle diagnostic socket.
What do these codes mean?
Detroit codes SPN 3659 FMI 3 to SPN 4258 FMI 4 are all about the amplifier control valve circuits. The most common failure type is shorted low (14 of 28); none needs an immediate stop. Start with this check: note the cylinder in the code and read whether needle valve or misfire codes appear on the same cylinder.
How urgent are they?
None of the 28 codes here means stop now; all 28 can wait until the shift ends, but find the cause before the next one.
- Check soon28
What should I check first?
Note the cylinder in the code and read whether needle valve or misfire codes appear on the same cylinder.
Shared checks28 of 28
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
Detroit SPN 3659 FMI 3Injector Cylinder #1 Amplifier Control Valve Abnormal Operation (MAX)
Detroit lists SPN 3659 FMI 3 as "Injector Cylinder #1 Amplifier Control Valve Abnormal Operation (MAX)". The MCM saw the injector amplifier control valve drawing more current than its upper limit during an injection pulse, which Detroit calls the MAX abnormal-operation limit. It is the cylinder 1 entry. Injector 1 amplifier control valve builds the injection pressure for the cylinder 1 injector; its signal runs in the same harness leg as the needle valve.· Shorted highShorted highCheck soonCauses
- A partial short inside the amplifier valve coil or in the injector connector pulling extra current
- Wire insulation damaged so the circuit leaks to another wire
Checks
- 1Measure the amplifier valve coil resistance at the harness connector and compare it with the other cylinders; a low value points to a shorted coil.
- 2Look for a damaged section of the valve cover harness where two injector wires touch.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Detroit SPN 3659 FMI 4Injector Cylinder #1 Amplifier Control Valve Abnormal Operation (MIN)
Detroit lists SPN 3659 FMI 4 as "Injector Cylinder #1 Amplifier Control Valve Abnormal Operation (MIN)". The MCM saw the injector amplifier control valve drawing less current than its lower limit during an injection pulse, which Detroit calls the MIN abnormal-operation limit. It is the cylinder 1 entry. Injector 1 amplifier control valve builds the injection pressure for the cylinder 1 injector; its signal runs in the same harness leg as the needle valve.· Shorted lowShorted lowCheck soonCauses
- High resistance in the amplifier valve circuit from a corroded pin or a half-broken wire
- Weak or sticking solenoid in the injector
Checks
- 1Check the amplifier valve connector pins for corrosion and spread terminals, then measure the circuit resistance end to end.
- 2Compare the value against a cylinder that has no code to see how far this one is out.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Detroit SPN 3659 FMI 5Injector Cylinder #1 Amplifier Control Valve Abnormal Operation (OPEN)
Detroit lists SPN 3659 FMI 5 as "Injector Cylinder #1 Amplifier Control Valve Abnormal Operation (OPEN)". The MCM found the injector amplifier control valve circuit open, so no current flows when the pulse is sent. It is the cylinder 1 entry. Injector 1 amplifier control valve builds the injection pressure for the cylinder 1 injector; its signal runs in the same harness leg as the needle valve.· Open circuitOpen circuitCheck soonCauses
- Broken wire or a pushed-out pin between the MCM and the amplifier valve
- Burned-out injector solenoid
Checks
- 1Check continuity of both amplifier valve wires between the MCM connector and the injector connector under the valve cover.
- 2Measure the solenoid resistance; an open reading means the injector has failed.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Detroit SPN 3659 FMI 6Injector Cylinder #1 Amplifier Control Valve - Valve Shorted Circuit
Detroit lists SPN 3659 FMI 6 as "Injector Cylinder #1 Amplifier Control Valve - Valve Shorted Circuit". The MCM found a short in the injector amplifier control valve circuit, so the driver current rises sharply when the pulse is sent. It is the cylinder 1 entry. Injector 1 amplifier control valve builds the injection pressure for the cylinder 1 injector; its signal runs in the same harness leg as the needle valve.· Shorted lowShorted lowCheck soonCauses
- Shorted amplifier valve solenoid winding
- Two injector wires rubbed together under the valve cover
Checks
- 1Unplug the amplifier valve at the injector and see whether the short remains; if it goes away the injector is shorted.
- 2Check between the injector wires and to ground at the harness side for a dead short.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Detroit SPN 3660 FMI 3Injector Cylinder #2 Amplifier Control Valve Abnormal Operation (MAX)
Same failure as SPN 3659 FMI 3 ("Injector Cylinder #1 Amplifier Control Valve Abnormal Operation (MAX)") on a sibling part: Detroit lists SPN 3660 FMI 3 as "Injector Cylinder #2 Amplifier Control Valve Abnormal Operation (MAX)". Injector 2 amplifier control valve builds the injection pressure for the cylinder 2 injector; its signal runs in the same harness leg as the needle valve.· Shorted highShorted highCheck soonCauses
- The causes listed under SPN 3659 FMI 3, found on this part and its own connector and harness leg
- A fault that affects only this channel and not the part that the first code names
Checks
- 1Run the checks listed under SPN 3659 FMI 3, but at this part and on its own wires.
- 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Detroit SPN 3660 FMI 4Injector Cylinder #2 Amplifier Control Valve Abnormal Operation (MIN)
Same failure as SPN 3659 FMI 4 ("Injector Cylinder #1 Amplifier Control Valve Abnormal Operation (MIN)") on a sibling part: Detroit lists SPN 3660 FMI 4 as "Injector Cylinder #2 Amplifier Control Valve Abnormal Operation (MIN)". Injector 2 amplifier control valve builds the injection pressure for the cylinder 2 injector; its signal runs in the same harness leg as the needle valve.· Shorted lowShorted lowCheck soonCauses
- The causes listed under SPN 3659 FMI 4, found on this part and its own connector and harness leg
- A fault that affects only this channel and not the part that the first code names
Checks
- 1Run the checks listed under SPN 3659 FMI 4, but at this part and on its own wires.
- 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Detroit SPN 3660 FMI 5Injector Cylinder #2 Amplifier Control Valve Abnormal Operation OPEN
Detroit lists SPN 3660 FMI 5 as "Injector Cylinder #2 Amplifier Control Valve Abnormal Operation OPEN". The MCM found the injector amplifier control valve circuit open, so no current flows when the pulse is sent. It is the cylinder 2 entry. Injector 2 amplifier control valve builds the injection pressure for the cylinder 2 injector; its signal runs in the same harness leg as the needle valve.· Open circuitOpen circuitCheck soonCauses
- Broken wire or a pushed-out pin between the MCM and the amplifier valve
- Burned-out injector solenoid
Checks
- 1Check continuity of both amplifier valve wires between the MCM connector and the injector connector under the valve cover.
- 2Measure the solenoid resistance; an open reading means the injector has failed.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Detroit SPN 3660 FMI 6Injector Cylinder #2 Amplifier Control Valve - Valve Shorted Circuit
Same failure as SPN 3659 FMI 6 ("Injector Cylinder #1 Amplifier Control Valve - Valve Shorted Circuit") on a sibling part: Detroit lists SPN 3660 FMI 6 as "Injector Cylinder #2 Amplifier Control Valve - Valve Shorted Circuit". Injector 2 amplifier control valve builds the injection pressure for the cylinder 2 injector; its signal runs in the same harness leg as the needle valve.· Shorted lowShorted lowCheck soonCauses
- The causes listed under SPN 3659 FMI 6, found on this part and its own connector and harness leg
- A fault that affects only this channel and not the part that the first code names
Checks
- 1Run the checks listed under SPN 3659 FMI 6, but at this part and on its own wires.
- 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Detroit SPN 3661 FMI 3Injector Cylinder #3 Amplifier Control Valve Abnormal Operation (MAX)
Same failure as SPN 3659 FMI 3 ("Injector Cylinder #1 Amplifier Control Valve Abnormal Operation (MAX)") on a sibling part: Detroit lists SPN 3661 FMI 3 as "Injector Cylinder #3 Amplifier Control Valve Abnormal Operation (MAX)". Injector 3 amplifier control valve builds the injection pressure for the cylinder 3 injector; its signal runs in the same harness leg as the needle valve.· Shorted highShorted highCheck soonCauses
- The causes listed under SPN 3659 FMI 3, found on this part and its own connector and harness leg
- A fault that affects only this channel and not the part that the first code names
Checks
- 1Run the checks listed under SPN 3659 FMI 3, but at this part and on its own wires.
- 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Detroit SPN 3661 FMI 4Injector Cylinder #3 Amplifier Control Valve Abnormal Operation (MIN)
Same failure as SPN 3659 FMI 4 ("Injector Cylinder #1 Amplifier Control Valve Abnormal Operation (MIN)") on a sibling part: Detroit lists SPN 3661 FMI 4 as "Injector Cylinder #3 Amplifier Control Valve Abnormal Operation (MIN)". Injector 3 amplifier control valve builds the injection pressure for the cylinder 3 injector; its signal runs in the same harness leg as the needle valve.· Shorted lowShorted lowCheck soonCauses
- The causes listed under SPN 3659 FMI 4, found on this part and its own connector and harness leg
- A fault that affects only this channel and not the part that the first code names
Checks
- 1Run the checks listed under SPN 3659 FMI 4, but at this part and on its own wires.
- 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Detroit SPN 3661 FMI 5Injector Cylinder #3 Amplifier Control Valve Abnormal Operation (Open)
Same failure as SPN 3659 FMI 5 ("Injector Cylinder #1 Amplifier Control Valve Abnormal Operation (OPEN)") on a sibling part: Detroit lists SPN 3661 FMI 5 as "Injector Cylinder #3 Amplifier Control Valve Abnormal Operation (Open)". Injector 3 amplifier control valve builds the injection pressure for the cylinder 3 injector; its signal runs in the same harness leg as the needle valve.· Open circuitOpen circuitCheck soonCauses
- The causes listed under SPN 3659 FMI 5, found on this part and its own connector and harness leg
- A fault that affects only this channel and not the part that the first code names
Checks
- 1Run the checks listed under SPN 3659 FMI 5, but at this part and on its own wires.
- 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Detroit SPN 3661 FMI 6Injector Cylinder #3 Amplifier Control Valve, Valve Shorted Circuit
Detroit lists SPN 3661 FMI 6 as "Injector Cylinder #3 Amplifier Control Valve, Valve Shorted Circuit". The MCM found a short in the injector amplifier control valve circuit, so the driver current rises sharply when the pulse is sent. It is the cylinder 3 entry. Injector 3 amplifier control valve builds the injection pressure for the cylinder 3 injector; its signal runs in the same harness leg as the needle valve.· Shorted lowShorted lowCheck soonCauses
- Shorted amplifier valve solenoid winding
- Two injector wires rubbed together under the valve cover
Checks
- 1Unplug the amplifier valve at the injector and see whether the short remains; if it goes away the injector is shorted.
- 2Check between the injector wires and to ground at the harness side for a dead short.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Detroit SPN 3662 FMI 3Injector Cylinder #4 Amplifier Control Valve Abnormal Operation (MAX)
Same failure as SPN 3659 FMI 3 ("Injector Cylinder #1 Amplifier Control Valve Abnormal Operation (MAX)") on a sibling part: Detroit lists SPN 3662 FMI 3 as "Injector Cylinder #4 Amplifier Control Valve Abnormal Operation (MAX)". Injector 4 amplifier control valve builds the injection pressure for the cylinder 4 injector; its signal runs in the same harness leg as the needle valve.· Shorted highShorted highCheck soonCauses
- The causes listed under SPN 3659 FMI 3, found on this part and its own connector and harness leg
- A fault that affects only this channel and not the part that the first code names
Checks
- 1Run the checks listed under SPN 3659 FMI 3, but at this part and on its own wires.
- 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Detroit SPN 3662 FMI 4Injector Cylinder #4 Amplifier Control Valve Abnormal Operation (MIN)
Same failure as SPN 3659 FMI 4 ("Injector Cylinder #1 Amplifier Control Valve Abnormal Operation (MIN)") on a sibling part: Detroit lists SPN 3662 FMI 4 as "Injector Cylinder #4 Amplifier Control Valve Abnormal Operation (MIN)". Injector 4 amplifier control valve builds the injection pressure for the cylinder 4 injector; its signal runs in the same harness leg as the needle valve.· Shorted lowShorted lowCheck soonCauses
- The causes listed under SPN 3659 FMI 4, found on this part and its own connector and harness leg
- A fault that affects only this channel and not the part that the first code names
Checks
- 1Run the checks listed under SPN 3659 FMI 4, but at this part and on its own wires.
- 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Detroit SPN 3662 FMI 5Injector Cylinder #4 Amplifier Control Valve Abnormal Operation (OPEN)
Same failure as SPN 3659 FMI 5 ("Injector Cylinder #1 Amplifier Control Valve Abnormal Operation (OPEN)") on a sibling part: Detroit lists SPN 3662 FMI 5 as "Injector Cylinder #4 Amplifier Control Valve Abnormal Operation (OPEN)". Injector 4 amplifier control valve builds the injection pressure for the cylinder 4 injector; its signal runs in the same harness leg as the needle valve.· Open circuitOpen circuitCheck soonCauses
- The causes listed under SPN 3659 FMI 5, found on this part and its own connector and harness leg
- A fault that affects only this channel and not the part that the first code names
Checks
- 1Run the checks listed under SPN 3659 FMI 5, but at this part and on its own wires.
- 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Detroit SPN 3662 FMI 6Injector Cylinder #4 Amplifier Control Valve - Valve Shorted Circuit
Same failure as SPN 3659 FMI 6 ("Injector Cylinder #1 Amplifier Control Valve - Valve Shorted Circuit") on a sibling part: Detroit lists SPN 3662 FMI 6 as "Injector Cylinder #4 Amplifier Control Valve - Valve Shorted Circuit". Injector 4 amplifier control valve builds the injection pressure for the cylinder 4 injector; its signal runs in the same harness leg as the needle valve.· Shorted lowShorted lowCheck soonCauses
- The causes listed under SPN 3659 FMI 6, found on this part and its own connector and harness leg
- A fault that affects only this channel and not the part that the first code names
Checks
- 1Run the checks listed under SPN 3659 FMI 6, but at this part and on its own wires.
- 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Detroit SPN 3663 FMI 3Injector Cylinder #5 Amplifier Control Valve Abnormal Operation (MAX)
Same failure as SPN 3659 FMI 3 ("Injector Cylinder #1 Amplifier Control Valve Abnormal Operation (MAX)") on a sibling part: Detroit lists SPN 3663 FMI 3 as "Injector Cylinder #5 Amplifier Control Valve Abnormal Operation (MAX)". Injector 5 amplifier control valve builds the injection pressure for the cylinder 5 injector; its signal runs in the same harness leg as the needle valve.· Shorted highShorted highCheck soonCauses
- The causes listed under SPN 3659 FMI 3, found on this part and its own connector and harness leg
- A fault that affects only this channel and not the part that the first code names
Checks
- 1Run the checks listed under SPN 3659 FMI 3, but at this part and on its own wires.
- 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Detroit SPN 3663 FMI 4Injector Cylinder #5 Amplifier Control Valve Abnormal Operation (MIN)
Same failure as SPN 3659 FMI 4 ("Injector Cylinder #1 Amplifier Control Valve Abnormal Operation (MIN)") on a sibling part: Detroit lists SPN 3663 FMI 4 as "Injector Cylinder #5 Amplifier Control Valve Abnormal Operation (MIN)". Injector 5 amplifier control valve builds the injection pressure for the cylinder 5 injector; its signal runs in the same harness leg as the needle valve.· Shorted lowShorted lowCheck soonCauses
- The causes listed under SPN 3659 FMI 4, found on this part and its own connector and harness leg
- A fault that affects only this channel and not the part that the first code names
Checks
- 1Run the checks listed under SPN 3659 FMI 4, but at this part and on its own wires.
- 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Detroit SPN 3663 FMI 5Injector Cylinder #5 Amplifier Control Valve Abnormal Operation (OPEN)
Same failure as SPN 3659 FMI 5 ("Injector Cylinder #1 Amplifier Control Valve Abnormal Operation (OPEN)") on a sibling part: Detroit lists SPN 3663 FMI 5 as "Injector Cylinder #5 Amplifier Control Valve Abnormal Operation (OPEN)". Injector 5 amplifier control valve builds the injection pressure for the cylinder 5 injector; its signal runs in the same harness leg as the needle valve.· Open circuitOpen circuitCheck soonCauses
- The causes listed under SPN 3659 FMI 5, found on this part and its own connector and harness leg
- A fault that affects only this channel and not the part that the first code names
Checks
- 1Run the checks listed under SPN 3659 FMI 5, but at this part and on its own wires.
- 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Detroit SPN 3663 FMI 6Injector Cylinder #5 Spill Control Valve - Valve Shorted Circuit
Detroit lists SPN 3663 FMI 6 as "Injector Cylinder #5 Spill Control Valve - Valve Shorted Circuit". The MCM found a short in the injector amplifier control valve circuit, so the driver current rises sharply when the pulse is sent. It is the cylinder 5 entry. Injector 5 amplifier control valve builds the injection pressure for the cylinder 5 injector; its signal runs in the same harness leg as the needle valve.· Shorted lowShorted lowCheck soonCauses
- Shorted amplifier valve solenoid winding
- Two injector wires rubbed together under the valve cover
Checks
- 1Unplug the amplifier valve at the injector and see whether the short remains; if it goes away the injector is shorted.
- 2Check between the injector wires and to ground at the harness side for a dead short.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Detroit SPN 3664 FMI 3Injector Cylinder #6 Amplifier Control Valve Abnormal Operation (MAX)
Same failure as SPN 3659 FMI 3 ("Injector Cylinder #1 Amplifier Control Valve Abnormal Operation (MAX)") on a sibling part: Detroit lists SPN 3664 FMI 3 as "Injector Cylinder #6 Amplifier Control Valve Abnormal Operation (MAX)". Injector 6 amplifier control valve builds the injection pressure for the cylinder 6 injector; its signal runs in the same harness leg as the needle valve.· Shorted highShorted highCheck soonCauses
- The causes listed under SPN 3659 FMI 3, found on this part and its own connector and harness leg
- A fault that affects only this channel and not the part that the first code names
Checks
- 1Run the checks listed under SPN 3659 FMI 3, but at this part and on its own wires.
- 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Detroit SPN 3664 FMI 4Injector Cylinder #6 Amplifier Control Valve Abnormal Operation (MIN)
Same failure as SPN 3659 FMI 4 ("Injector Cylinder #1 Amplifier Control Valve Abnormal Operation (MIN)") on a sibling part: Detroit lists SPN 3664 FMI 4 as "Injector Cylinder #6 Amplifier Control Valve Abnormal Operation (MIN)". Injector 6 amplifier control valve builds the injection pressure for the cylinder 6 injector; its signal runs in the same harness leg as the needle valve.· Shorted lowShorted lowCheck soonCauses
- The causes listed under SPN 3659 FMI 4, found on this part and its own connector and harness leg
- A fault that affects only this channel and not the part that the first code names
Checks
- 1Run the checks listed under SPN 3659 FMI 4, but at this part and on its own wires.
- 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Detroit SPN 3664 FMI 5Injector Cylinder #6 Amplifier Control Valve Abnormal Operation (Open)
Same failure as SPN 3659 FMI 5 ("Injector Cylinder #1 Amplifier Control Valve Abnormal Operation (OPEN)") on a sibling part: Detroit lists SPN 3664 FMI 5 as "Injector Cylinder #6 Amplifier Control Valve Abnormal Operation (Open)". Injector 6 amplifier control valve builds the injection pressure for the cylinder 6 injector; its signal runs in the same harness leg as the needle valve.· Open circuitOpen circuitCheck soonCauses
- The causes listed under SPN 3659 FMI 5, found on this part and its own connector and harness leg
- A fault that affects only this channel and not the part that the first code names
Checks
- 1Run the checks listed under SPN 3659 FMI 5, but at this part and on its own wires.
- 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Detroit SPN 3664 FMI 6Injector Cylinder #6 Amplifier Control Valve - Valve Shorted Circuit
Same failure as SPN 3659 FMI 6 ("Injector Cylinder #1 Amplifier Control Valve - Valve Shorted Circuit") on a sibling part: Detroit lists SPN 3664 FMI 6 as "Injector Cylinder #6 Amplifier Control Valve - Valve Shorted Circuit". Injector 6 amplifier control valve builds the injection pressure for the cylinder 6 injector; its signal runs in the same harness leg as the needle valve.· Shorted lowShorted lowCheck soonCauses
- The causes listed under SPN 3659 FMI 6, found on this part and its own connector and harness leg
- A fault that affects only this channel and not the part that the first code names
Checks
- 1Run the checks listed under SPN 3659 FMI 6, but at this part and on its own wires.
- 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Detroit SPN 4257 FMI 3Injector Amplifier Control Valve Cylinder 1, 2, 3 Shorted to Battery
Detroit lists SPN 4257 FMI 3 as "Injector Amplifier Control Valve Cylinder 1, 2, 3 Shorted to Battery". The MCM saw the injector amplifier control valve drawing more current than its upper limit during an injection pulse, which Detroit calls the MAX abnormal-operation limit. It is the cylinder 1 entry. Amplifier control valves are grouped by bank; this code flags a short that touches the cylinder 1, 2 and 3 group.· Shorted highShorted highCheck soonCauses
- A partial short inside the amplifier valve coil or in the injector connector pulling extra current
- Wire insulation damaged so the circuit leaks to another wire
Checks
- 1Measure the amplifier valve coil resistance at the harness connector and compare it with the other cylinders; a low value points to a shorted coil.
- 2Look for a damaged section of the valve cover harness where two injector wires touch.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Detroit SPN 4257 FMI 4Injector Amplifier Control Valve Cylinder 1, 2, 3 Shorted to Ground
Detroit lists SPN 4257 FMI 4 as "Injector Amplifier Control Valve Cylinder 1, 2, 3 Shorted to Ground". The MCM saw the injector amplifier control valve drawing less current than its lower limit during an injection pulse, which Detroit calls the MIN abnormal-operation limit. It is the cylinder 1 entry. Amplifier control valves are grouped by bank; this code flags a short that touches the cylinder 1, 2 and 3 group.· Shorted lowShorted lowCheck soonCauses
- High resistance in the amplifier valve circuit from a corroded pin or a half-broken wire
- Weak or sticking solenoid in the injector
Checks
- 1Check the amplifier valve connector pins for corrosion and spread terminals, then measure the circuit resistance end to end.
- 2Compare the value against a cylinder that has no code to see how far this one is out.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Detroit SPN 4258 FMI 3Injector Amplifier Control Valve Cylinder 4, 5, 6 Shorted to Battery
Same failure as SPN 4257 FMI 3 ("Injector Amplifier Control Valve Cylinder 1, 2, 3 Shorted to Battery") on a sibling part: Detroit lists SPN 4258 FMI 3 as "Injector Amplifier Control Valve Cylinder 4, 5, 6 Shorted to Battery". Amplifier control valves are grouped by bank; this code flags a short that touches the cylinder 4, 5 and 6 group.· Shorted highShorted highCheck soonCauses
- The causes listed under SPN 4257 FMI 3, found on this part and its own connector and harness leg
- A fault that affects only this channel and not the part that the first code names
Checks
- 1Run the checks listed under SPN 4257 FMI 3, but at this part and on its own wires.
- 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Detroit SPN 4258 FMI 4Injector Amplifier Control Valve Cylinder 4, 5, 6 Shorted to Ground
Same failure as SPN 4257 FMI 4 ("Injector Amplifier Control Valve Cylinder 1, 2, 3 Shorted to Ground") on a sibling part: Detroit lists SPN 4258 FMI 4 as "Injector Amplifier Control Valve Cylinder 4, 5, 6 Shorted to Ground". Amplifier control valves are grouped by bank; this code flags a short that touches the cylinder 4, 5 and 6 group.· Shorted lowShorted lowCheck soonCauses
- The causes listed under SPN 4257 FMI 4, found on this part and its own connector and harness leg
- A fault that affects only this channel and not the part that the first code names
Checks
- 1Run the checks listed under SPN 4257 FMI 4, but at this part and on its own wires.
- 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Shared checks
Checks, in order
- 1Note the cylinder in the code and read whether needle valve or misfire codes appear on the same cylinder.
- 2Inspect the injector connector and harness under the valve cover for oil, burns and chafing.
- 3Measure the amplifier circuit resistance at the harness and compare it with a good cylinder.
- 4Check for a short between injector wires with the MCM connector unplugged.
- 5Swap the harness section or injector that fails, clear the code and confirm the fault stays away.
Causes
- Injector amplifier solenoid or internal wiring defect
- Harness damage under the valve cover or at the injector connector
- Short between two injector circuits
- MCM driver output problem
Most common here: shorted low (14 of 28)
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
When to stop
You'll notice: Rough idle, a misfire and loss of power on the cylinder named in the code; the check-engine lamp stays on.
Common-rail fuel runs at very high pressure. Never open a high-pressure line or fitting with the engine running or just after it stops - a fine fuel jet can pierce skin.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
- Detroit Diesel DD15 Gen 5 (2023) Fault Codes List, Diesel Repair (SPN/FMI with Detroit descriptions)
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.