Cummins · Operator controls
Cummins PTO governor and idle controls fault codes
A power take-off governor lets the operator hold a set engine speed using enable, set, resume, accelerate and coast switches, sometimes through a remote panel. Idle increment and decrement switches let the operator adjust the idle speed from the cab.
More about these partsLess
The ECM can shut the engine down at idle and can allow idle events to be overridden.
Where to read it
Connect INSITE or another J1939-capable scan tool to the 9-pin diagnostic port.
What do these codes mean?
Cummins codes 338 to 14623 are all about the pTO governor and idle controls. The most common failure type is erratic or implausible (8 of 19); none needs an immediate stop. Start with this check: watch each PTO switch state in INSITE while operating it.
How urgent are they?
None of the 19 codes here means stop now; all 19 can wait until the shift ends, but find the cause before the next one.
- Check soon19
What should I check first?
Watch each PTO switch state in INSITE while operating it
Shared checks19 of 19
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
Idle shutdown vehicle accessories relay driver circuit2 codes
Cummins 338Idle shutdown vehicle accessories relay driver circuit: Voltage high / shorted high
The ECM reads the idle shutdown vehicle accessories relay driver circuit above its allowed voltage band. That points to a short to a 5 V or battery wire, a lost return, or a failed part, rather than a real change in what it measures. The relay driver switches vehicle accessories off when the idle shutdown timer expires.· Shorted highShorted highCheck soonCauses
- Short to a 5 V reference or a battery wire in the harness to the idle shutdown vehicle accessories relay driver circuit
- Open or high-resistance return wire that lets the signal float high
- Water or corrosion in the connector bridging two pins together
Checks
- 1Key on, unplug the idle shutdown vehicle accessories relay driver circuit and read its circuit at the harness: a high reading with the part removed means the wiring is shorted high or the return is lost
- 2Jumper the signal wire of the idle shutdown vehicle accessories relay driver circuit to ground at the harness and see whether the code changes to a low-voltage code, which proves the wiring and the ECM input
- 3Check continuity and resistance of the return wire from the idle shutdown vehicle accessories relay driver circuit back to the ECM
- 4Check the accessories relay and its fuse, and that the coil resistance is normal.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:Idle shutdown vehicle accessories relay driver circuit - voltage high (shorted to a high source)
Cummins 339Idle shutdown vehicle accessories relay driver circuit: Voltage low / shorted low
The ECM reads the idle shutdown vehicle accessories relay driver circuit below its allowed voltage band. That points to a short to ground, an open supply or signal wire, or a failed part, not necessarily a real low value. The relay driver switches vehicle accessories off when the idle shutdown timer expires.· Shorted lowShorted lowCheck soonCauses
- Signal wire to the idle shutdown vehicle accessories relay driver circuit rubbed through and shorted to ground or to the engine block
- Open 5 V reference or open signal wire that lets the input drop to zero
- Corroded or backed-out pin in the idle shutdown vehicle accessories relay driver circuit connector
Checks
- 1Key on, unplug the idle shutdown vehicle accessories relay driver circuit and read its circuit at the harness: a reading near zero with the part removed means the wiring is shorted to ground or open
- 2Jumper the 5 V reference to the signal wire at the harness and see whether the code changes to a high-voltage code, which proves the wiring and the ECM input
- 3Measure resistance from the idle shutdown vehicle accessories relay driver circuit signal wire to ground with the ECM unplugged to find a short
- 4Check the accessories relay and its fuse, and that the coil resistance is normal.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Idle shutdown vehicle accessories relay driver circuit - voltage low (shorted to a low source)
Engine idle management pending event override2 codes
Cummins 8182Engine idle management pending event override: Abnormal update rate
Same failure as 14362 on the engine idle management pending event override: the same fault condition as 14362, reported for this part. The idle management pending event override lets the vehicle request that the engine stay running for a pending event.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Same causes as 14362, applied to the engine idle management pending event override
- Wiring or connector problem local to the engine idle management pending event override
Checks
- 1Check the vehicle controller that sends the override request and its configuration.
- 2Work through the checks listed for 14362, starting at the engine idle management pending event override and its connector
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Cummins 8183Engine idle management pending event override: Out of calibration
Same failure as 14361 on the engine idle management pending event override: the same fault condition as 14361, reported for this part. The idle management pending event override lets the vehicle request that the engine stay running for a pending event.· Part or controllerPart or controllerCheck soonCauses
- Same causes as 14361, applied to the engine idle management pending event override
- Wiring or connector problem local to the engine idle management pending event override
Checks
- 1Check the vehicle controller that sends the override request and its configuration.
- 2Work through the checks listed for 14361, starting at the engine idle management pending event override and its connector
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Engine idle decrement switch2 codes
Cummins 14349Engine idle decrement switch: Out of calibration
Same failure as 14361 on the engine idle decrement switch: the same fault condition as 14361, reported for this part. The idle increment and decrement switches let the operator trim the idle speed within the allowed range.· Part or controllerPart or controllerCheck soonCauses
- Same causes as 14361, applied to the engine idle decrement switch
- Wiring or connector problem local to the engine idle decrement switch
Checks
- 1Press the idle switch and watch the idle speed target change in INSITE.
- 2Work through the checks listed for 14361, starting at the engine idle decrement switch and its connector
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Cummins 14351Engine idle decrement switch: Abnormal update rate
Same failure as 14362 on the engine idle decrement switch: the same fault condition as 14362, reported for this part. The idle increment and decrement switches let the operator trim the idle speed within the allowed range.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Same causes as 14362, applied to the engine idle decrement switch
- Wiring or connector problem local to the engine idle decrement switch
Checks
- 1Press the idle switch and watch the idle speed target change in INSITE.
- 2Work through the checks listed for 14362, starting at the engine idle decrement switch and its connector
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Engine idle increment switch1 code
Cummins 14353Engine idle increment switch: Abnormal update rate
Same failure as 14362 on the engine idle increment switch: the same fault condition as 14362, reported for this part. The idle increment and decrement switches let the operator trim the idle speed within the allowed range.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Same causes as 14362, applied to the engine idle increment switch
- Wiring or connector problem local to the engine idle increment switch
Checks
- 1Press the idle switch and watch the idle speed target change in INSITE.
- 2Work through the checks listed for 14362, starting at the engine idle increment switch and its connector
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Engine PTO governor accelerate switch2 codes
Cummins 14358Engine PTO governor accelerate switch: Abnormal update rate
Same failure as 14362 on the engine PTO governor accelerate switch: the same fault condition as 14362, reported for this part. The accelerate switch raises the governed PTO engine speed.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Same causes as 14362, applied to the engine PTO governor accelerate switch
- Wiring or connector problem local to the engine PTO governor accelerate switch
Checks
- 1Hold accelerate and watch the target speed climb and the switch state change in INSITE.
- 2Work through the checks listed for 14362, starting at the engine PTO governor accelerate switch and its connector
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Cummins 14622Engine PTO governor accelerate switch: Out of calibration
Same failure as 14361 on the engine PTO governor accelerate switch: the same fault condition as 14361, reported for this part. The accelerate switch raises the governed PTO engine speed.· Part or controllerPart or controllerCheck soonCauses
- Same causes as 14361, applied to the engine PTO governor accelerate switch
- Wiring or connector problem local to the engine PTO governor accelerate switch
Checks
- 1Hold accelerate and watch the target speed climb and the switch state change in INSITE.
- 2Work through the checks listed for 14361, starting at the engine PTO governor accelerate switch and its connector
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Engine PTO governor coast/decelerate switch2 codes
Cummins 14359Engine PTO governor coast/decelerate switch: Abnormal update rate
Same failure as 14362 on the engine PTO governor coast/decelerate switch: the same fault condition as 14362, reported for this part. The coast/decelerate switch lowers the governed PTO engine speed.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Same causes as 14362, applied to the engine PTO governor coast/decelerate switch
- Wiring or connector problem local to the engine PTO governor coast/decelerate switch
Checks
- 1Hold coast and watch the target speed fall and the switch state change in INSITE.
- 2Work through the checks listed for 14362, starting at the engine PTO governor coast/decelerate switch and its connector
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Cummins 14623Engine PTO governor coast/decelerate switch: Out of calibration
Same failure as 14361 on the engine PTO governor coast/decelerate switch: the same fault condition as 14361, reported for this part. The coast/decelerate switch lowers the governed PTO engine speed.· Part or controllerPart or controllerCheck soonCauses
- Same causes as 14361, applied to the engine PTO governor coast/decelerate switch
- Wiring or connector problem local to the engine PTO governor coast/decelerate switch
Checks
- 1Hold coast and watch the target speed fall and the switch state change in INSITE.
- 2Work through the checks listed for 14361, starting at the engine PTO governor coast/decelerate switch and its connector
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Engine remote PTO governor preprogrammed speed control switch2 codes
Cummins 14361Engine remote PTO governor preprogrammed speed control switch: Out of calibration
The ECM reports the engine remote PTO governor preprogrammed speed control switch as out of calibration: the value or setting it received does not match what the ECM was programmed to expect. The remote preprogrammed speed switch selects one of the stored PTO speeds from a panel outside the cab.· Part or controllerPart or controllerCheck soonCauses
- Parameter set for a feature that is not fitted on this vehicle
- Wrong or outdated calibration in the ECM
- Source module sending an invalid or unscaled value for the engine remote PTO governor preprogrammed speed control switch
Checks
- 1Compare the ECM parameters with the vehicle equipment, especially those that enable the engine remote PTO governor preprogrammed speed control switch
- 2Reflash the ECM with the correct calibration if the software level does not match
- 3Read the source module for its own codes and check its configuration
- 4Operate the remote panel and check that the selected speed state arrives at the ECM.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Cummins 14362Engine remote PTO governor preprogrammed speed control switch: Abnormal update rate
The ECM is not receiving fresh data for the engine remote PTO governor preprogrammed speed control switch at the expected rate. The message is late or missing on the data link, or the sending module has stopped updating it. The remote preprogrammed speed switch selects one of the stored PTO speeds from a panel outside the cab.· Lost messageLost messageCheck soonCauses
- Data link wiring fault or a poor connector contact
- The module that sends the message for the engine remote PTO governor preprogrammed speed control switch is offline or failing
- Power or ground problem at the sending module
Checks
- 1Look for other modules reporting timeouts to find where the link is broken
- 2Check the data link wiring, connectors and both terminators near the engine remote PTO governor preprogrammed speed control switch source
- 3Read the module that sends the engine remote PTO governor preprogrammed speed control switch for its own codes and for power or ground faults
- 4Operate the remote panel and check that the selected speed state arrives at the ECM.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Engine PTO governor resume switch2 codes
Cummins 14363Engine PTO governor resume switch: Out of calibration
Same failure as 14361 on the engine PTO governor resume switch: the same fault condition as 14361, reported for this part. The PTO resume switch returns the engine to the stored PTO speed.· Part or controllerPart or controllerCheck soonCauses
- Same causes as 14361, applied to the engine PTO governor resume switch
- Wiring or connector problem local to the engine PTO governor resume switch
Checks
- 1Press PTO resume after a speed change and confirm the state follows the switch.
- 2Work through the checks listed for 14361, starting at the engine PTO governor resume switch and its connector
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Cummins 14364Engine PTO governor resume switch: Abnormal update rate
Same failure as 14362 on the engine PTO governor resume switch: the same fault condition as 14362, reported for this part. The PTO resume switch returns the engine to the stored PTO speed.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Same causes as 14362, applied to the engine PTO governor resume switch
- Wiring or connector problem local to the engine PTO governor resume switch
Checks
- 1Press PTO resume after a speed change and confirm the state follows the switch.
- 2Work through the checks listed for 14362, starting at the engine PTO governor resume switch and its connector
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Engine PTO governor set switch2 codes
Cummins 14365Engine PTO governor set switch: Out of calibration
Same failure as 14361 on the engine PTO governor set switch: the same fault condition as 14361, reported for this part. The PTO set switch stores the current engine speed as the PTO target speed.· Part or controllerPart or controllerCheck soonCauses
- Same causes as 14361, applied to the engine PTO governor set switch
- Wiring or connector problem local to the engine PTO governor set switch
Checks
- 1Press and release PTO set at the desired speed and confirm the state follows the switch.
- 2Work through the checks listed for 14361, starting at the engine PTO governor set switch and its connector
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Cummins 14366Engine PTO governor set switch: Abnormal update rate
Same failure as 14362 on the engine PTO governor set switch: the same fault condition as 14362, reported for this part. The PTO set switch stores the current engine speed as the PTO target speed.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Same causes as 14362, applied to the engine PTO governor set switch
- Wiring or connector problem local to the engine PTO governor set switch
Checks
- 1Press and release PTO set at the desired speed and confirm the state follows the switch.
- 2Work through the checks listed for 14362, starting at the engine PTO governor set switch and its connector
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Engine PTO governor enable switch2 codes
Cummins 14367Engine PTO governor enable switch: Out of calibration
Same failure as 14361 on the engine PTO governor enable switch: the same fault condition as 14361, reported for this part. The PTO governor enable switch allows the engine to be held at a set speed for PTO work.· Part or controllerPart or controllerCheck soonCauses
- Same causes as 14361, applied to the engine PTO governor enable switch
- Wiring or connector problem local to the engine PTO governor enable switch
Checks
- 1Toggle the PTO enable switch and confirm the state in INSITE, with the transmission and park brake conditions met.
- 2Work through the checks listed for 14361, starting at the engine PTO governor enable switch and its connector
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Cummins 14368Engine PTO governor enable switch: Abnormal update rate
Same failure as 14362 on the engine PTO governor enable switch: the same fault condition as 14362, reported for this part. The PTO governor enable switch allows the engine to be held at a set speed for PTO work.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Same causes as 14362, applied to the engine PTO governor enable switch
- Wiring or connector problem local to the engine PTO governor enable switch
Checks
- 1Toggle the PTO enable switch and confirm the state in INSITE, with the transmission and park brake conditions met.
- 2Work through the checks listed for 14362, starting at the engine PTO governor enable switch and its connector
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Shared checks
Checks, in order
- 1Watch each PTO switch state in INSITE while operating it
- 2Press the idle increment and decrement switches and confirm both change state in INSITE
- 3Check the idle shutdown parameters in the ECM
- 4Check the PTO panel wiring and connector for damage
- 5Check the idle adjust enable and its speed limits in the ECM parameter list
- 6Look at the data link for missing PTO messages from the body controller
- 7Inspect the dash switch connector and the wiring behind the panel
Causes
- Switch panel wiring or switch failure
- Idle up/down rocker switch contacts worn
- Relay or wiring fault
- Data link message from the body controller missing
Most common here: erratic or implausible (8 of 19)
Watch the live value on the service tool while you flex the harness and tap the connector.
When to stop
You'll notice: PTO speed control may not work or may not respond to the switches.
Most sensor and wiring faults can be traced with a multimeter and the wiring diagram. Disconnect the battery before unplugging controllers; if the controller itself is suspect or needs programming, that needs the dealer’s service tool.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
- Cummins L9 (2024-2025) Fault Code List (Diesel Repair)
- Cummins ISX15 (2013-2018) Fault Codes List (Diesel Repair)
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.