Cummins · Operator controls
Cummins Accelerator pedal and remote throttle fault codes
The accelerator pedal carries two position sensors and an idle validation switch that tell the ECM how much power the operator wants. A remote throttle lets the engine be controlled from a pedal or lever outside the cab, enabled by a switch and an interlock.
Where to read it
Connect INSITE or another J1939-capable scan tool to the 9-pin diagnostic port.
What do these codes mean?
Cummins codes 131 to 15691 are all about the accelerator pedal and remote throttle. The most common failure type is lost message (9 of 25); none needs an immediate stop. Start with this check: watch both pedal sensor values in INSITE while pressing the pedal slowly; they should track each other smoothly.
How urgent are they?
None of the 25 codes here means stop now; all 25 can wait until the shift ends, but find the cause before the next one.
- Check soon25
What should I check first?
Watch both pedal sensor values in INSITE while pressing the pedal slowly; they should track each other smoothly
Shared checks25 of 25
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
Remote accelerator pedal or lever position sensor 1 circuit4 codes
Cummins 133Remote accelerator pedal or lever position sensor 1 circuit: Voltage high / shorted high
The ECM sees the remote accelerator pedal or lever position sensor 1 circuit signal circuit above its normal voltage band. That points to a short to the 5 V reference or a battery wire, a lost return, or a sensor that failed high, not a real change in what it measures.· Shorted highShorted highCheck soonCauses
- Signal wire shorted to the 5 V reference or battery voltage in the harness
- Open sensor return wire letting the signal float up
- Sensor failed high or its connector is corroded
Checks
- 1Read the live remote accelerator pedal or lever position sensor 1 circuit value with the key on; a reading pinned at the top of its range confirms the high-voltage fault
- 2Unplug the sensor and check reference and return at the harness, since a lost return gives the same symptom
- 3With the key off, test the signal wire for continuity to the reference and to battery positive
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:Remote accelerator pedal or lever position sensor 1 circuit - voltage high (shorted to a high source)
Cummins 134Remote accelerator pedal or lever position sensor 1 circuit: Voltage low / shorted low
The ECM sees the remote accelerator pedal or lever position sensor 1 circuit signal circuit below its normal voltage band. That is how a short to ground, an open 5 V reference or a sensor that failed low looks, rather than a real change in what it measures.· Shorted lowShorted lowCheck soonCauses
- Signal wire shorted to ground in the harness
- Open 5 V reference wire so the signal collapses
- Sensor failed low or its connector is wet or corroded
Checks
- 1Read the live remote accelerator pedal or lever position sensor 1 circuit value with the key on; a reading pinned at the bottom of its range confirms the low-voltage fault
- 2Unplug the sensor and check that the 5 V reference arrives at the connector
- 3With the key off, test the signal wire for a short to ground
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Remote accelerator pedal or lever position sensor 1 circuit - voltage low (shorted to a low source)
Cummins 1361Remote accelerator pedal or lever position sensor 1 circuit: Voltage low / shorted low
The ECM sees the remote accelerator pedal or lever position sensor 1 circuit signal circuit below its normal voltage band. That is how a short to ground, an open 5 V reference or a sensor that failed low looks, rather than a real change in what it measures.· Shorted lowShorted lowCheck soonCauses
- Signal wire shorted to ground in the harness
- Open 5 V reference wire so the signal collapses
- Sensor failed low or its connector is wet or corroded
Checks
- 1Read the live remote accelerator pedal or lever position sensor 1 circuit value with the key on; a reading pinned at the bottom of its range confirms the low-voltage fault
- 2Unplug the sensor and check that the 5 V reference arrives at the connector
- 3With the key off, test the signal wire for a short to ground
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Remote accelerator pedal or lever position sensor 1 circuit - voltage low (shorted to a low source)
Cummins 1595Remote accelerator pedal or lever position sensor 1 circuit: Voltage high / shorted high
The ECM sees the remote accelerator pedal or lever position sensor 1 circuit signal circuit above its normal voltage band. That points to a short to the 5 V reference or a battery wire, a lost return, or a sensor that failed high, not a real change in what it measures.· Shorted highShorted highCheck soonCauses
- Signal wire shorted to the 5 V reference or battery voltage in the harness
- Open sensor return wire letting the signal float up
- Sensor failed high or its connector is corroded
Checks
- 1Read the live remote accelerator pedal or lever position sensor 1 circuit value with the key on; a reading pinned at the top of its range confirms the high-voltage fault
- 2Unplug the sensor and check reference and return at the harness, since a lost return gives the same symptom
- 3With the key off, test the signal wire for continuity to the reference and to battery positive
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:Remote accelerator pedal or lever position sensor 1 circuit - voltage high (shorted to a high source)
SAE J1939 multiplexing remote accelerator pedal or lever position sensor system2 codes
Cummins 288SAE J1939 multiplexing remote accelerator pedal or lever position sensor system: Network data in error
The ECM received the SAE J1939 multiplexing remote accelerator pedal or lever position sensor system over the data link but the message is flagged as invalid, so it cannot be used. The fault is usually in the sending module or the link, not the ECM.· Lost messageLost messageCheck soonCauses
- Sending module reporting an invalid value
- Data link wiring or connector fault
Checks
- 1Find which module sends the message and read its codes
- 2Check the data link wiring and connectors
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Source wording:SAE J1939 multiplexing remote accelerator pedal or lever position sensor system - network data received in error
Cummins 6417SAE J1939 multiplexing remote accelerator pedal or lever position sensor system: Network data in error
The ECM received the SAE J1939 multiplexing remote accelerator pedal or lever position sensor system over the data link but the message is flagged as invalid, so it cannot be used. The fault is usually in the sending module or the link, not the ECM.· Lost messageLost messageCheck soonCauses
- Sending module reporting an invalid value
- Data link wiring or connector fault
Checks
- 1Find which module sends the message and read its codes
- 2Check the data link wiring and connectors
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Source wording:SAE J1939 multiplexing remote accelerator pedal or lever position sensor system - network data received in error
Accelerator pedal or lever position sensor 2 circuit2 codes
Cummins 1239Accelerator pedal or lever position sensor 2 circuit: Voltage high / shorted high
The ECM sees the accelerator pedal or lever position sensor 2 circuit signal circuit above its normal voltage band. That points to a short to the 5 V reference or a battery wire, a lost return, or a sensor that failed high, not a real change in what it measures.· Shorted highShorted highCheck soonCauses
- Signal wire shorted to the 5 V reference or battery voltage in the harness
- Open sensor return wire letting the signal float up
- Sensor failed high or its connector is corroded
Checks
- 1Read the live accelerator pedal or lever position sensor 2 circuit value with the key on; a reading pinned at the top of its range confirms the high-voltage fault
- 2Unplug the sensor and check reference and return at the harness, since a lost return gives the same symptom
- 3With the key off, test the signal wire for continuity to the reference and to battery positive
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:Accelerator pedal or lever position sensor 2 circuit - voltage high (shorted to a high source)
Cummins 1241Accelerator pedal or lever position sensor 2 circuit: Voltage low / shorted low
The ECM sees the accelerator pedal or lever position sensor 2 circuit signal circuit below its normal voltage band. That is how a short to ground, an open 5 V reference or a sensor that failed low looks, rather than a real change in what it measures.· Shorted lowShorted lowCheck soonCauses
- Signal wire shorted to ground in the harness
- Open 5 V reference wire so the signal collapses
- Sensor failed low or its connector is wet or corroded
Checks
- 1Read the live accelerator pedal or lever position sensor 2 circuit value with the key on; a reading pinned at the bottom of its range confirms the low-voltage fault
- 2Unplug the sensor and check that the 5 V reference arrives at the connector
- 3With the key off, test the signal wire for a short to ground
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Accelerator pedal or lever position sensor 2 circuit - voltage low (shorted to a low source)
Multiplexed accelerator pedal signal1 code
Cummins 1515Multiplexed accelerator pedal signal: Network data error
The accelerator pedal position sent over the data link is in error, so the ECM cannot trust the throttle demand.· Lost messageLost messageCheck soonCauses
- Body or chassis module sending a bad pedal message
- Data link wiring fault
- Pedal sensor fault
Checks
- 1Check the pedal value on the data link in INSITE
- 2Check the chassis or body module that sends the pedal value for codes
- 3Check the J1939 wiring between the pedal module and the ECM
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
SAE J1939 multiplexed accelerator pedal or lever sensor system1 code
Cummins 3326SAE J1939 multiplexed accelerator pedal or lever sensor system: Abnormal update rate
The ECM is not receiving fresh data for the SAE J1939 multiplexed accelerator pedal or lever sensor system at the expected rate, so the value is late or has stopped updating.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Wiring or connector contact fault
- Sending module offline or failing
Checks
- 1Check the wiring and connector for loose terminals
- 2Look for related data link or module faults
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Accelerator pedal or lever idle validation switch2 codes
Cummins 3527Accelerator pedal or lever idle validation switch: Network data in error
The ECM received the accelerator pedal or lever idle validation switch over the data link but the message is flagged as invalid, so it cannot be used. The fault is usually in the sending module or the link, not the ECM.· Lost messageLost messageCheck soonCauses
- Sending module reporting an invalid value
- Data link wiring or connector fault
Checks
- 1Find which module sends the message and read its codes
- 2Check the data link wiring and connectors
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Source wording:Accelerator pedal or lever idle validation switch - network data received in error
Cummins 3528Accelerator pedal or lever idle validation switch: Abnormal update rate
The ECM is not receiving fresh data for the accelerator pedal or lever idle validation switch at the expected rate. The message is late or missing on the data link, or the input has stopped updating.· Lost messageLost messageCheck soonCauses
- Data link wiring fault or a poor connector contact
- The module that sends the message is offline or failing
- Power or ground problem at the sending module
Checks
- 1Look for other modules reporting timeouts to find where the link is broken
- 2Check the data link wiring, connectors and terminators
- 3Read the sending module for its own codes
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Accelerator pedal or lever position sensor 2 circuit frequency1 code
Cummins 4149Accelerator pedal or lever position sensor 2 circuit frequency: Abnormal frequency / pulse width
The ECM sees the accelerator pedal or lever position sensor 2 circuit frequency or pulse width outside its expected range, which means the signal is distorted or its duty cycle is wrong.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Signal wire damaged or picking up interference
- Failed sensor or encoder electronics
Checks
- 1Check the accelerator pedal or lever position sensor 2 circuit frequency wiring for damage and keep it away from ignition and high-current wires
- 2Compare the signal with the redundant signal in INSITE
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Source wording:Accelerator pedal or lever position sensor 2 circuit frequency - abnormal frequency or pulse width
Accelerator pedal or lever position sensor 1 circuit frequency1 code
Cummins 4289Accelerator pedal or lever position sensor 1 circuit frequency: Abnormal frequency / pulse width
The ECM sees the accelerator pedal or lever position sensor 1 circuit frequency or pulse width outside its expected range, which means the signal is distorted or its duty cycle is wrong.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Signal wire damaged or picking up interference
- Failed sensor or encoder electronics
Checks
- 1Check the accelerator pedal or lever position sensor 1 circuit frequency wiring for damage and keep it away from ignition and high-current wires
- 2Compare the signal with the redundant signal in INSITE
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Source wording:Accelerator pedal or lever position sensor 1 circuit frequency - abnormal frequency or pulse width
Accelerator pedal position 11 code
Cummins 6919Accelerator pedal position 1: Out of calibration
The ECM reports the accelerator pedal position 1 as out of calibration, so its value does not agree with the stored calibration or with the other data it is compared against.· Part or controllerPart or controllerCheck soonCauses
- Sensor or device out of tolerance
- Wrong calibration or learn data after a repair
Checks
- 1Check whether a learn or calibration procedure is needed after the last repair
- 2Compare with a related sensor and replace the part if the offset is real
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Accelerator interlock switch2 codes
Cummins 14331Accelerator interlock switch: Out of calibration
The ECM reports the accelerator interlock switch as out of calibration, meaning the value or setting it received does not match what it was programmed to expect.· Part or controllerPart or controllerCheck soonCauses
- Parameter set for a feature that is not fitted
- Wrong or outdated calibration in the ECM
- Source module sending an invalid value
Checks
- 1Compare the ECM parameters with the vehicle equipment
- 2Reflash the ECM with the correct calibration
- 3Read the source module for its own codes
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Cummins 14332Accelerator interlock switch: Abnormal update rate
The ECM is not receiving fresh data for the accelerator interlock switch at the expected rate. The message is late or missing on the data link, or the input has stopped updating.· Lost messageLost messageCheck soonCauses
- Data link wiring fault or a poor connector contact
- The module that sends the message is offline or failing
- Power or ground problem at the sending module
Checks
- 1Look for other modules reporting timeouts to find where the link is broken
- 2Check the data link wiring, connectors and terminators
- 3Read the sending module for its own codes
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Remote accelerator pedal position3 codes
Cummins 14372Remote accelerator pedal position: Out of calibration
The ECM reports the remote accelerator pedal position as out of calibration, so its value does not agree with the stored calibration or with the other data it is compared against.· Part or controllerPart or controllerCheck soonCauses
- Sensor or device out of tolerance
- Wrong calibration or learn data after a repair
Checks
- 1Check whether a learn or calibration procedure is needed after the last repair
- 2Compare with a related sensor and replace the part if the offset is real
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Cummins 14375Remote accelerator pedal position: Abnormal update rate
The ECM is not receiving fresh data for the remote accelerator pedal position at the expected rate, so the value is late or has stopped updating.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Wiring or connector contact fault
- Sending module offline or failing
Checks
- 1Check the wiring and connector for loose terminals
- 2Look for related data link or module faults
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Cummins 15691Remote accelerator pedal position: Network data in error
The ECM received the remote accelerator pedal position over the data link but the message is flagged as invalid, so it cannot be used. The fault is usually in the sending module or the link, not the ECM.· Lost messageLost messageCheck soonCauses
- Sending module reporting an invalid value
- Data link wiring or connector fault
Checks
- 1Find which module sends the message and read its codes
- 2Check the data link wiring and connectors
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Source wording:Remote accelerator pedal position - network data received in error
Remote accelerator enable switch2 codes
Cummins 14373Remote accelerator enable switch: Out of calibration
The ECM reports the remote accelerator enable switch as out of calibration, meaning the value or setting it received does not match what it was programmed to expect.· Part or controllerPart or controllerCheck soonCauses
- Parameter set for a feature that is not fitted
- Wrong or outdated calibration in the ECM
- Source module sending an invalid value
Checks
- 1Compare the ECM parameters with the vehicle equipment
- 2Reflash the ECM with the correct calibration
- 3Read the source module for its own codes
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Cummins 14374Remote accelerator enable switch: Abnormal update rate
The ECM is not receiving fresh data for the remote accelerator enable switch at the expected rate. The message is late or missing on the data link, or the input has stopped updating.· Lost messageLost messageCheck soonCauses
- Data link wiring fault or a poor connector contact
- The module that sends the message is offline or failing
- Power or ground problem at the sending module
Checks
- 1Look for other modules reporting timeouts to find where the link is broken
- 2Check the data link wiring, connectors and terminators
- 3Read the sending module for its own codes
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Other codes3 codes
Cummins 131Accelerator pedal position sensor signal voltage high
The ECM sees the accelerator pedal position sensor signal above its normal voltage band. That is what a short to the 5 V reference or a battery wire, a lost sensor return, or a sensor that failed high looks like. Throttle demand comes from this sensor.· Shorted highShorted highCheck soonCauses
- Pedal signal wire rubbed bare at the firewall grommet and touching the reference line
- Open return wire inside the pedal connector, so the signal rises to reference
- Pedal track wiper worn and giving a stuck-high output
- Footwell water corroding the pedal connector pins
Checks
- 1Read pedal percent with the key on and the foot off; anything above zero at rest points to a high signal
- 2Unplug the pedal and check 5 V reference and return at the harness side
- 3Check the pedal signal wire for a short to the reference or battery positive
- 4Check the return continuity from the pedal connector to the ECM
- 5Fit a new pedal assembly if the harness is good and the signal stays high
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Cummins 132Accelerator pedal position sensor signal voltage low
The ECM sees the accelerator pedal position sensor signal below its normal voltage band. That points to a signal wire shorted to ground, a lost 5 V reference or a sensor that failed low. Throttle demand comes from this sensor.· Shorted lowShorted lowCheck soonCauses
- Pedal signal wire chafed to ground where it enters the cab floor
- 5 V reference open at the pedal connector, so the sensor has no supply
- Pedal track failed low after internal damage
- Pedal connector pushed on crooked
Checks
- 1With the key on press the pedal slowly and watch the percent; a reading stuck at zero points to a low signal fault
- 2Measure 5 V between reference and return at the unplugged pedal connector
- 3Ohm the signal wire to chassis ground with the ECM plug removed
- 4Wiggle the harness at the firewall while watching the percent value
- 5Replace the pedal assembly once the harness tests clean
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Cummins 1242Accelerator pedal sensors 1 and 2 disagree
The two accelerator pedal position tracks do not agree with each other. The ECM may limit power until it can trust the pedal.· Lost messageLost messageCheck soonCauses
- Pedal assembly sensor out of sync
- Pedal wiring or connector fault
- Pedal not learned after replacement
Checks
- 1Watch both pedal values while sweeping the pedal
- 2Check the pedal connector and wiring for corrosion and loose pins
- 3Check the 5 V reference and return at the pedal connector for a steady value
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Shared checks
Checks, in order
- 1Watch both pedal sensor values in INSITE while pressing the pedal slowly; they should track each other smoothly
- 2Check the remote throttle and enable switch status in INSITE while operating them
- 3Check 5 V reference, return and signal at the pedal connector with the key on
- 4Measure reference, return and signal at the remote pedal connector
- 5Inspect the pedal connector for water and bent pins
- 6Inspect the wiring from the body controller or junction box to the ECM
- 7Wiggle the harness while watching the pedal reading for dropouts
Causes
- Worn or contaminated pedal sensor track
- Remote pedal sensor or wiring fault
- Chafed pedal harness or corroded connector
- Enable or interlock switch not seen by the ECM
Most common here: lost message (9 of 25)
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
When to stop
You'll notice: The engine may idle only, respond slowly or limit power; with both sensors faulty the pedal is ignored.
Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
- Cummins ISX15 (2013-2018) Fault Codes List (Diesel Repair)
- Cummins L9 (2024-2025) Fault Code List (Diesel Repair)
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.