Bobcat · Auxiliary hydraulics
Bobcat Rear auxiliary solenoids fault codes
The rear auxiliary valve moves an attachment on the rear of the machine with a base solenoid for one direction and a rod solenoid for the other. Lock solenoids hold the spool and a relief solenoid sets the pressure.
More about these partsLess
A code names the solenoid and whether its circuit is shorted to ground or battery, open, over current, or driven on or off wrongly.
Where this code shows
On touchscreen R-series machines, touch the screen and pick Service Codes from the menu.
What do these codes mean?
Bobcat codes 23-02 to H2432 are all about the rear auxiliary solenoids. The most common failure type is shorted low (8 of 26); none needs an immediate stop. Start with this check: work out which direction is dead from the code: base solenoid for one direction, rod for the other, lock or relief for holding and pressure.
How urgent are they?
None of the 26 codes here means stop now; all 26 can wait until the shift ends, but find the cause before the next one.
- Check soon26
What should I check first?
Work out which direction is dead from the code: base solenoid for one direction, rod for the other, lock or relief for holding and pressure.
Shared checks26 of 26
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
Bobcat 23-02Rear base solenoid error on
The controller sees the valve solenoid switched on when it was commanded off, so the function stays on. The driver, relay or wiring is holding it on.· OtherOtherCheck soonCauses
- Output wire shorted to a live supply
- Relay or driver stuck closed
- Controller output stage failed and cannot switch off
Checks
- 1Unplug the valve solenoid at the rear valve connector with the key on; if the controller still reads it on, the fault is in the wiring or controller.
- 2Check the output wire for contact with a power wire along its run.
- 3Listen and feel for the solenoid coil energising while it should be off.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat 23-03Rear base solenoid error off
The controller sees the valve solenoid off when it was commanded on, so the rear auxiliary does not respond. The circuit is open, shorted to ground or not being driven.· Shorted lowShorted lowCheck soonCauses
- Open or grounded output wire
- The solenoid coil failed open
- Blown fuse or missing supply to the circuit
Checks
- 1Check the fuse and supply to the valve solenoid circuit with the key on.
- 2Measure the resistance of the solenoid coil and look for an open or a short to its body.
- 3Command the function and measure voltage at the valve solenoid plug; none means a wiring or controller fault.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat 24-02Rear rod solenoid error on
Rear rod solenoid error on: same fault as 23-02 (the output reads on when it should be off), here on the rear rod solenoid.· OtherOtherCheck soonCauses
- Output wire shorted to a live supply
- Relay or driver stuck closed
Checks
- 1Unplug the rear rod solenoid with the key on and see whether the controller still reads it on.
- 2Test steps: see 23-02.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat 24-03Rear rod solenoid error off
Rear rod solenoid error off: same fault as 23-03 (the output reads off when it was commanded on), here on the rear rod solenoid.· OtherOtherCheck soonCauses
- Open or grounded output wire
- The solenoid coil failed open
Checks
- 1Check the fuse and the supply voltage at the rear rod solenoid plug with the output commanded.
- 2Test steps: see 23-03.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat 25-02Rear auxiliary relief solenoid error on
The controller sees the relief solenoid switched on when it was commanded off, so the relief stays energised. The driver, relay or wiring is holding it on.· OtherOtherCheck soonCauses
- Output wire shorted to a live supply
- Relay or driver stuck closed
- Controller output stage failed and cannot switch off
Checks
- 1Unplug the relief solenoid at the relief solenoid on the rear valve with the key on; if the controller still reads it on, the fault is in the wiring or controller.
- 2Check the output wire for contact with a power wire along its run.
- 3Listen and feel for the relief solenoid coil energising while it should be off.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat 25-03Rear auxiliary relief solenoid error off
The controller sees the relief solenoid off when it was commanded on, so the rear auxiliary relief pressure is not set. The circuit is open, shorted to ground or not being driven.· Shorted lowShorted lowCheck soonCauses
- Open or grounded output wire
- The relief solenoid coil failed open
- Blown fuse or missing supply to the circuit
Checks
- 1Check the fuse and supply to the relief solenoid circuit with the key on.
- 2Measure the resistance of the relief solenoid coil and look for an open or a short to its body.
- 3Command the function and measure voltage at the relief solenoid plug; none means a wiring or controller fault.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat C1070-11Rear auxiliary base solenoid short to ground
The controller reads the valve solenoid circuit pulled to ground, so it cannot drive the load. The output is shut off and the rear auxiliary does not respond until the short is cleared.· Shorted lowShorted lowCheck soonCauses
- Wire chafed against the frame or a bracket at the rear valve connector
- The solenoid coil shorted to its housing
- Water in the connector or a pin touching the shell
Checks
- 1With the plug off, test the valve solenoid output wire to chassis ground; a reading near zero shows a harness short.
- 2Measure from each pin of the solenoid coil to its body; any continuity means the part itself is shorted.
- 3Look for harness sections crushed under clamps or cut by sharp edges at the rear valve connector.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat C1070-12Rear auxiliary base solenoid short to battery
The controller reads the valve solenoid circuit tied to battery voltage when it should only be switched by the controller. It shuts the output off to protect its driver, so the rear auxiliary does not respond.· Shorted highShorted highCheck soonCauses
- Output wire rubbed through at the rear valve connector and touching a live supply wire
- Water or corrosion in the plug bridging a pin to a power pin
- Controller output stage failed shorted to supply
Checks
- 1Unplug the valve solenoid at the rear valve connector and check its output wire for voltage with the key on; any voltage with the load removed is a short to supply.
- 2Trace the wire back from the solenoid coil for chafing next to live supply wires and for melted insulation.
- 3Replace the solenoid coil only if the wire reads clean and the part itself reads shorted.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Bobcat C1070-13Rear auxiliary base solenoid open circuit
The controller sees an open circuit on the valve solenoid, so no current can flow through it and the rear auxiliary does not respond. The break is in the wire, the connector or the part itself.· Open circuitOpen circuitCheck soonCauses
- Pin backed out of the connector or plug not latched at the rear valve connector
- Wire broken inside its insulation near a bend or clamp
- The solenoid coil burnt open or its internal lead broken
Checks
- 1Check that the valve solenoid connector at the rear valve connector is fully seated and its lock tab engaged.
- 2Measure the resistance of the solenoid coil with the plug off; an infinite reading confirms an open.
- 3Check continuity of each wire from the valve solenoid plug back to the controller connector, flexing the harness as you go.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat C1071-11Rear auxiliary base lock solenoid short to ground
The controller reads the lock solenoid circuit pulled to ground, so it cannot drive the load. The output is shut off and the rear auxiliary spool is not held and may drift until the short is cleared.· Shorted lowShorted lowCheck soonCauses
- Wire chafed against the frame or a bracket at the rear valve lock solenoid
- The lock solenoid coil shorted to its housing
- Water in the connector or a pin touching the shell
Checks
- 1With the plug off, test the lock solenoid output wire to chassis ground; a reading near zero shows a harness short.
- 2Measure from each pin of the lock solenoid coil to its body; any continuity means the part itself is shorted.
- 3Look for harness sections crushed under clamps or cut by sharp edges at the rear valve lock solenoid.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat C1071-12Rear auxiliary base lock solenoid short to battery
The controller reads the lock solenoid circuit tied to battery voltage when it should only be switched by the controller. It shuts the output off to protect its driver, so the rear auxiliary spool is not held and may drift.· Shorted highShorted highCheck soonCauses
- Output wire rubbed through at the rear valve lock solenoid and touching a live supply wire
- Water or corrosion in the plug bridging a pin to a power pin
- Controller output stage failed shorted to supply
Checks
- 1Unplug the lock solenoid at the rear valve lock solenoid and check its output wire for voltage with the key on; any voltage with the load removed is a short to supply.
- 2Trace the wire back from the lock solenoid coil for chafing next to live supply wires and for melted insulation.
- 3Replace the lock solenoid coil only if the wire reads clean and the part itself reads shorted.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Bobcat C1071-13Rear auxiliary base lock open circuit
The controller sees an open circuit on the lock solenoid, so no current can flow through it and the rear auxiliary spool is not held and may drift. The break is in the wire, the connector or the part itself.· Open circuitOpen circuitCheck soonCauses
- Pin backed out of the connector or plug not latched at the rear valve lock solenoid
- Wire broken inside its insulation near a bend or clamp
- The lock solenoid coil burnt open or its internal lead broken
Checks
- 1Check that the lock solenoid connector at the rear valve lock solenoid is fully seated and its lock tab engaged.
- 2Measure the resistance of the lock solenoid coil with the plug off; an infinite reading confirms an open.
- 3Check continuity of each wire from the lock solenoid plug back to the controller connector, flexing the harness as you go.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat C1075-11Rear auxiliary rod solenoid short to ground
Rear auxiliary rod solenoid short to ground: same fault as C1070-11 (the circuit reads pulled to ground), here on the rear auxiliary rod solenoid.· Shorted lowShorted lowCheck soonCauses
- Wire chafed against the frame or a bracket
- The solenoid coil shorted to its housing
Checks
- 1Test the rear auxiliary rod solenoid output wire to chassis ground with the plug off.
- 2Test steps: see C1070-11.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat C1075-12Rear auxiliary rod solenoid short to battery
Rear auxiliary rod solenoid short to battery: same fault as C1070-12 (the circuit reads tied to battery voltage), here on the rear auxiliary rod solenoid.· Shorted highShorted highCheck soonCauses
- Output wire rubbed through
- Water or corrosion in the plug bridging a pin to a power pin
Checks
- 1Unplug the rear auxiliary rod solenoid and look for voltage on its output wire with the key on.
- 2Test steps: see C1070-12.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Bobcat C1075-13Rear auxiliary rod solenoid open circuit
Rear auxiliary rod solenoid open circuit: same fault as C1070-13 (the circuit is open), here on the rear auxiliary rod solenoid.· Open circuitOpen circuitCheck soonCauses
- Pin backed out of the connector or plug not latched
- Wire broken inside its insulation
Checks
- 1Check the rear auxiliary rod solenoid connector is seated, then measure across the part for an open.
- 2Test steps: see C1070-13.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat C1076-11Rear auxiliary rod lock solenoid short to ground
Rear auxiliary rod lock solenoid short to ground: same fault as C1071-11 (the circuit reads pulled to ground), here on the rear auxiliary rod lock solenoid.· Shorted lowShorted lowCheck soonCauses
- Wire chafed against the frame or a bracket
- The lock solenoid coil shorted to its housing
Checks
- 1Test the rear auxiliary rod lock solenoid output wire to chassis ground with the plug off.
- 2Test steps: see C1071-11.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat C1076-12Rear auxiliary rod lock solenoid short to battery
Rear auxiliary rod lock solenoid short to battery: same fault as C1071-12 (the circuit reads tied to battery voltage), here on the rear auxiliary rod lock solenoid.· Shorted highShorted highCheck soonCauses
- Output wire rubbed through
- Water or corrosion in the plug bridging a pin to a power pin
Checks
- 1Unplug the rear auxiliary rod lock solenoid and look for voltage on its output wire with the key on.
- 2Test steps: see C1071-12.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Bobcat C1076-13Rear auxiliary rod solenoid open circuit
Rear auxiliary rod solenoid open circuit: same fault as C1070-13 (the circuit is open), here on the rear auxiliary rod solenoid.· Open circuitOpen circuitCheck soonCauses
- Pin backed out of the connector or plug not latched
- Wire broken inside its insulation
Checks
- 1Check the rear auxiliary rod solenoid connector is seated, then measure across the part for an open.
- 2Test steps: see C1070-13.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat H2305Rear base solenoid short to battery
Rear base solenoid short to battery: same fault as C1070-12 (the circuit reads tied to battery voltage), here on the rear base solenoid.· Shorted highShorted highCheck soonCauses
- Output wire rubbed through
- Water or corrosion in the plug bridging a pin to a power pin
Checks
- 1Unplug the rear base solenoid and look for voltage on its output wire with the key on.
- 2Test steps: see C1070-12.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Bobcat H2306Rear base solenoid short to ground
Rear base solenoid short to ground: same fault as C1070-11 (the circuit reads pulled to ground), here on the rear base solenoid.· Shorted lowShorted lowCheck soonCauses
- Wire chafed against the frame or a bracket
- The solenoid coil shorted to its housing
Checks
- 1Test the rear base solenoid output wire to chassis ground with the plug off.
- 2Test steps: see C1070-11.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat H2307Rear base solenoid open circuit
Rear base solenoid open circuit: same fault as C1070-13 (the circuit is open), here on the rear base solenoid.· Open circuitOpen circuitCheck soonCauses
- Pin backed out of the connector or plug not latched
- Wire broken inside its insulation
Checks
- 1Check the rear base solenoid connector is seated, then measure across the part for an open.
- 2Test steps: see C1070-13.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat H2332Rear base solenoid overcurrent
The controller measured too much current on the valve solenoid output and switched it off to protect its driver, so the rear auxiliary does not respond until the overload is cleared.· Real conditionReal conditionCheck soonCauses
- Coil shorted between turns so it draws too much current
- Wiring partly shorted to ground at the rear valve connector
- Wrong or damaged part fitted that loads the output
Checks
- 1Measure the resistance of the solenoid coil with the plug off and compare it with a matching part on the same machine.
- 2Check the valve solenoid wire for a partial short to ground that only shows when the machine is hot or vibrating.
- 3Replace the part and clear the code; if it returns at once, suspect the controller output.
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Bobcat H2405Rear rod solenoid short to battery
Rear rod solenoid short to battery: same fault as C1070-12 (the circuit reads tied to battery voltage), here on the rear rod solenoid.· Shorted highShorted highCheck soonCauses
- Output wire rubbed through
- Water or corrosion in the plug bridging a pin to a power pin
Checks
- 1Unplug the rear rod solenoid and look for voltage on its output wire with the key on.
- 2Test steps: see C1070-12.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Bobcat H2406Rear rod solenoid short to ground
Rear rod solenoid short to ground: same fault as C1070-11 (the circuit reads pulled to ground), here on the rear rod solenoid.· Shorted lowShorted lowCheck soonCauses
- Wire chafed against the frame or a bracket
- The solenoid coil shorted to its housing
Checks
- 1Test the rear rod solenoid output wire to chassis ground with the plug off.
- 2Test steps: see C1070-11.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat H2407Rear rod solenoid open circuit
Rear rod solenoid open circuit: same fault as C1070-13 (the circuit is open), here on the rear rod solenoid.· Open circuitOpen circuitCheck soonCauses
- Pin backed out of the connector or plug not latched
- Wire broken inside its insulation
Checks
- 1Check the rear rod solenoid connector is seated, then measure across the part for an open.
- 2Test steps: see C1070-13.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat H2432Rear rod solenoid overcurrent
Rear rod solenoid overcurrent: same fault as H2332 (the circuit draws more current than the driver allows), here on the rear rod solenoid.· OtherOtherCheck soonCauses
- Coil shorted between turns so it draws too much current
- Wiring partly shorted to ground
Checks
- 1Measure the resistance of the rear rod solenoid and compare it with a matching part.
- 2Test steps: see H2332.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Shared checks
Checks, in order
- 1Work out which direction is dead from the code: base solenoid for one direction, rod for the other, lock or relief for holding and pressure.
- 2Measure each rear solenoid coil with the plug off; the base and rod coils should read about the same as each other.
- 3Check the connector at the rear valve block for water and pushed-back pins, then reseat it.
- 4Measure voltage at the solenoid plug while the function is commanded from the cab.
- 5Inspect the rear harness along the frame and tailgate for rubbing, which gives short-to-ground codes that come and go.
Causes
- Base or rod solenoid coil shorted or burnt open
- Harness chafed where it runs to the rear valve block
- Connector at the rear valve corroded or a pin pushed back
- Relief or lock solenoid plunger sticking from dirty oil
Most common here: shorted low (8 of 26)
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
When to stop
You'll notice: The rear auxiliary function on the machine does not extend or retract, creeps, or will not stop, depending on which solenoid failed.
Lower attachments to the ground and relieve hydraulic pressure before loosening any fitting. Never feel for a leak with your hand - oil under pressure can inject through skin.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
- Bobcat Service Code List (rev. 10-20, M-Series/R-Series loaders and M-Series excavators)
- Bobcat S205 Operation & Maintenance Manual, service codes list
- Bobcat S205 Operation & Maintenance Manual, service codes list
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.