Bobcat Excavator auxiliary, power beyond and reverse solenoids fault codes

The excavator auxiliary base and rod solenoids set attachment direction, the power beyond valve passes oil past the main valve, the attachment reverse solenoid flips direction and the hydraulic exchange output runs the exchange function. A code names the part and the failure.

FaultCheckM1802Bobcat · Excavator auxiliary, power beyond and reverse solenoids
Code shows hereFAULTM1802

Where this code shows

On touchscreen R-series machines, touch the screen and pick Service Codes from the menu.

What do these codes mean?

Bobcat codes M1802 to A8803 are all about the excavator auxiliary, power beyond and reverse solenoids. The most common failure type is shorted low (6 of 16); none needs an immediate stop. Start with this check: operate the auxiliary control in each direction and note which direction fails; that names the base or rod solenoid.

How urgent are they?

None of the 16 codes here means stop now; all 16 can wait until the shift ends, but find the cause before the next one.

  • Check soon16

What should I check first?

Operate the auxiliary control in each direction and note which direction fails; that names the base or rod solenoid.

Shared checks

16 of 16

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Bobcat M1802Power beyond valve output error on

    The controller sees the power beyond valve output switched on when it was commanded off, so the circuit stays on.· Other
    Check soon

    Causes

    • Output wire shorted to a live supply
    • Relay or driver stuck closed
    • Controller output stage failed and cannot switch off

    Checks

    1. 1Unplug the power beyond valve output at the power beyond valve connector with the key on; if the controller still reads it on, the fault is in the wiring or controller.
    2. 2Check the output wire for contact with a power wire along its run.
    3. 3Listen and feel for the valve coil energising while it should be off.
    4. 4Check what is connected to the power beyond port and confirm the coupler is fully seated before suspecting the valve.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M1803Power beyond valve output error off

    The controller sees the power beyond valve output off when it was commanded on, so the power beyond circuit does not switch.· Shorted low
    Check soon

    Causes

    • Open or grounded output wire
    • The valve coil failed open
    • Blown fuse or missing supply to the circuit

    Checks

    1. 1Check the fuse and supply to the power beyond valve output circuit with the key on.
    2. 2Measure the resistance of the valve coil and look for an open or a short to its body.
    3. 3Command the function and measure voltage at the power beyond valve output plug; none means a wiring or controller fault.
    4. 4Check what is connected to the power beyond port and confirm the coupler is fully seated before suspecting the valve.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat M1902Power beyond valve relay error on

    The controller sees the power beyond valve relay switched on when it was commanded off, so the circuit stays on.· Other
    Check soon

    Causes

    • Output wire shorted to a live supply
    • Relay or driver stuck closed
    • Controller output stage failed and cannot switch off

    Checks

    1. 1Unplug the power beyond valve relay at the power beyond valve connector with the key on; if the controller still reads it on, the fault is in the wiring or controller.
    2. 2Check the output wire for contact with a power wire along its run.
    3. 3Listen and feel for the valve coil energising while it should be off.
    4. 4Check what is connected to the power beyond port and confirm the coupler is fully seated before suspecting the valve.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M1903Power beyond valve relay error off

    The controller sees the power beyond valve relay off when it was commanded on, so the power beyond circuit does not switch.· Shorted low
    Check soon

    Causes

    • Open or grounded output wire
    • The valve coil failed open
    • Blown fuse or missing supply to the circuit

    Checks

    1. 1Check the fuse and supply to the power beyond valve relay circuit with the key on.
    2. 2Measure the resistance of the valve coil and look for an open or a short to its body.
    3. 3Command the function and measure voltage at the power beyond valve relay plug; none means a wiring or controller fault.
    4. 4Check what is connected to the power beyond port and confirm the coupler is fully seated before suspecting the valve.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat M3702Hyd exchange output error on

    The controller sees the hyd exchange output switched on when it was commanded off, so the output stays on.· Other
    Check soon

    Causes

    • Output wire shorted to a live supply
    • Relay or driver stuck closed
    • Controller output stage failed and cannot switch off

    Checks

    1. 1Unplug the hyd exchange output at the exchange output connector with the key on; if the controller still reads it on, the fault is in the wiring or controller.
    2. 2Check the output wire for contact with a power wire along its run.
    3. 3Listen and feel for the output energising while it should be off.
    4. 4Check the exchange coupler or quick-attach is fully latched and its connector is clean.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M3703Hyd exchange output error off

    The controller sees the hyd exchange output off when it was commanded on, so the hydraulic exchange function does not respond.· Shorted low
    Check soon

    Causes

    • Open or grounded output wire
    • The output failed open
    • Blown fuse or missing supply to the circuit

    Checks

    1. 1Check the fuse and supply to the hyd exchange output circuit with the key on.
    2. 2Measure the resistance of the output and look for an open or a short to its body.
    3. 3Command the function and measure voltage at the hyd exchange output plug; none means a wiring or controller fault.
    4. 4Check the exchange coupler or quick-attach is fully latched and its connector is clean.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat M5505Auxiliary base solenoid short to battery

    The controller reads the auxiliary solenoid circuit tied to battery voltage when it should only be switched by the controller.· Shorted high
    Check soon

    Causes

    • Output wire rubbed through at the auxiliary valve connector and touching a live supply wire
    • Water or corrosion in the plug bridging a pin to a power pin
    • Controller output stage failed shorted to supply

    Checks

    1. 1Unplug the auxiliary solenoid at the auxiliary valve connector and check its output wire for voltage with the key on; any voltage with the load removed is a short to supply.
    2. 2Trace the wire back from the solenoid coil for chafing next to live supply wires and for melted insulation.
    3. 3Replace the solenoid coil only if the wire reads clean and the part itself reads shorted.
    4. 4Check the oil level and the auxiliary relief setting only after the electrical tests pass.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat M5506Auxiliary base solenoid short to ground

    The controller reads the auxiliary solenoid circuit pulled to ground, so it cannot drive the load.· Shorted low
    Check soon

    Causes

    • Wire chafed against the frame or a bracket at the auxiliary valve connector
    • The solenoid coil shorted to its housing
    • Water in the connector or a pin touching the shell

    Checks

    1. 1With the plug off, test the auxiliary solenoid output wire to chassis ground; a reading near zero shows a harness short.
    2. 2Measure from each pin of the solenoid coil to its body; any continuity means the part itself is shorted.
    3. 3Look for harness sections crushed under clamps or cut by sharp edges at the auxiliary valve connector.
    4. 4Check the oil level and the auxiliary relief setting only after the electrical tests pass.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat M5507Auxiliary base solenoid open circuit

    The controller sees an open circuit on the auxiliary solenoid, so no current can flow through it and the attachment does not move in that direction.· Open circuit
    Check soon

    Causes

    • Pin backed out of the connector or plug not latched at the auxiliary valve connector
    • Wire broken inside its insulation near a bend or clamp
    • The solenoid coil burnt open or its internal lead broken

    Checks

    1. 1Check that the auxiliary solenoid connector at the auxiliary valve connector is fully seated and its lock tab engaged.
    2. 2Measure the resistance of the solenoid coil with the plug off; an infinite reading confirms an open.
    3. 3Check continuity of each wire from the auxiliary solenoid plug back to the controller connector, flexing the harness as you go.
    4. 4Check the oil level and the auxiliary relief setting only after the electrical tests pass.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Bobcat M5532Auxiliary base solenoid overcurrent

    The controller measured too much current on the auxiliary solenoid output and switched it off to protect its driver, so the attachment does not move in that direction until the overload is cleared.· Real condition
    Check soon

    Causes

    • Coil shorted between turns so it draws too much current
    • Wiring partly shorted to ground at the auxiliary valve connector
    • Wrong or damaged part fitted that loads the output

    Checks

    1. 1Measure the resistance of the solenoid coil with the plug off and compare it with a matching part on the same machine.
    2. 2Check the auxiliary solenoid wire for a partial short to ground that only shows when the machine is hot or vibrating.
    3. 3Replace the part and clear the code; if it returns at once, suspect the controller output.
    4. 4Check the oil level and the auxiliary relief setting only after the electrical tests pass.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Bobcat M5605Auxiliary rod solenoid short to battery

    Auxiliary rod solenoid short to battery: same fault as M5505 (the circuit reads tied to battery voltage), here on the auxiliary rod solenoid.· Shorted high
    Check soon

    Causes

    • Output wire rubbed through
    • Water or corrosion in the plug bridging a pin to a power pin

    Checks

    1. 1Unplug the auxiliary rod solenoid and look for voltage on its output wire with the key on.
    2. 2Test steps: see M5505.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat M5606Auxiliary rod solenoid short to ground

    Auxiliary rod solenoid short to ground: same fault as M5506 (the circuit reads pulled to ground), here on the auxiliary rod solenoid.· Shorted low
    Check soon

    Causes

    • Wire chafed against the frame or a bracket
    • The solenoid coil shorted to its housing

    Checks

    1. 1Test the auxiliary rod solenoid output wire to chassis ground with the plug off.
    2. 2Test steps: see M5506.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat M5607Auxiliary rod solenoid open circuit

    Auxiliary rod solenoid open circuit: same fault as M5507 (the circuit is open), here on the auxiliary rod solenoid.· Open circuit
    Check soon

    Causes

    • Pin backed out of the connector or plug not latched
    • Wire broken inside its insulation

    Checks

    1. 1Check the auxiliary rod solenoid connector is seated, then measure across the part for an open.
    2. 2Test steps: see M5507.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Bobcat M5632Auxiliary rod solenoid overcurrent

    Auxiliary rod solenoid overcurrent: same fault as M5532 (the circuit draws more current than the driver allows), here on the auxiliary rod solenoid.· Other
    Check soon

    Causes

    • Coil shorted between turns so it draws too much current
    • Wiring partly shorted to ground

    Checks

    1. 1Measure the resistance of the auxiliary rod solenoid and compare it with a matching part.
    2. 2Test steps: see M5532.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat A8802Reverse solenoid error on

    The controller sees the reverse solenoid switched on when it was commanded off, so the attachment stays reversed.· Other
    Check soon

    Causes

    • Output wire shorted to a live supply
    • Relay or driver stuck closed
    • Controller output stage failed and cannot switch off

    Checks

    1. 1Unplug the reverse solenoid at the reverse solenoid connector with the key on; if the controller still reads it on, the fault is in the wiring or controller.
    2. 2Check the output wire for contact with a power wire along its run.
    3. 3Listen and feel for the reverse solenoid coil energising while it should be off.
    4. 4Select each attachment direction in turn and note whether the reverse solenoid clicks as the direction changes.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat A8803Reverse solenoid error off

    The controller sees the reverse solenoid off when it was commanded on, so the attachment cannot be reversed.· Shorted low
    Check soon

    Causes

    • Open or grounded output wire
    • The reverse solenoid coil failed open
    • Blown fuse or missing supply to the circuit

    Checks

    1. 1Check the fuse and supply to the reverse solenoid circuit with the key on.
    2. 2Measure the resistance of the reverse solenoid coil and look for an open or a short to its body.
    3. 3Command the function and measure voltage at the reverse solenoid plug; none means a wiring or controller fault.
    4. 4Select each attachment direction in turn and note whether the reverse solenoid clicks as the direction changes.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

Shared checks

Checks, in order

  1. 1Operate the auxiliary control in each direction and note which direction fails; that names the base or rod solenoid.
  2. 2Measure the named coil resistance with the plug off and compare it with the matching coil.
  3. 3Measure voltage at the plug while the function is commanded.
  4. 4Check the coupler and connector are fully seated before suspecting the valve.
  5. 5Check the connector for water and bent pins, then clear the code and retest.

Causes

  • Auxiliary or reverse coil failed open, shorted or over current
  • Harness damaged where it passes the boom, stick or coupler
  • Connector corrosion at the valve
  • Valve spool or poppet sticking from dirty oil

Most common here: shorted low (6 of 16)

Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

When to stop

You'll notice: The attachment moves in the wrong direction or not at all, or the power beyond or exchange function does not respond.

Lower attachments to the ground and relieve hydraulic pressure before loosening any fitting. Never feel for a leak with your hand - oil under pressure can inject through skin.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.