Bobcat Diverter and high flow solenoids fault codes

The diverter solenoids route attachment oil between circuits and the high flow solenoid adds extra oil to the attachment line. A code names the solenoid and whether its circuit is shorted to ground or battery, open, over current or driven on or off wrongly.

FaultCheck28-02Bobcat · Diverter and high flow solenoids
Code shows hereFAULT28-02

Where this code shows

On touchscreen R-series machines, touch the screen and pick Service Codes from the menu.

What do these codes mean?

Bobcat codes 28-02 to H2932 are all about the diverter and high flow solenoids. The most common failure type is shorted high (6 of 19); none needs an immediate stop. Start with this check: switch between diverter positions and high flow from the cab and listen for each valve to shift.

How urgent are they?

None of the 19 codes here means stop now; all 19 can wait until the shift ends, but find the cause before the next one.

  • Check soon19

What should I check first?

Switch between diverter positions and high flow from the cab and listen for each valve to shift.

Shared checks

19 of 19

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Bobcat 28-02Diverter solenoid error on

    The controller sees the diverter solenoid switched on when it was commanded off, so the oil stays diverted.· Lost message
    Check soon

    Causes

    • Output wire shorted to a live supply
    • Relay or driver stuck closed
    • Controller output stage failed and cannot switch off

    Checks

    1. 1Unplug the diverter solenoid at the diverter valve connector with the key on; if the controller still reads it on, the fault is in the wiring or controller.
    2. 2Check the output wire for contact with a power wire along its run.
    3. 3Listen and feel for the diverter solenoid coil energising while it should be off.
    4. 4Switch between the diverter positions from the cab and listen for the valve to shift at each change.
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Bobcat 28-03Diverter solenoid error off

    The controller sees the diverter solenoid off when it was commanded on, so the oil is not routed to the right circuit.· Shorted low
    Check soon

    Causes

    • Open or grounded output wire
    • The diverter solenoid coil failed open
    • Blown fuse or missing supply to the circuit

    Checks

    1. 1Check the fuse and supply to the diverter solenoid circuit with the key on.
    2. 2Measure the resistance of the diverter solenoid coil and look for an open or a short to its body.
    3. 3Command the function and measure voltage at the diverter solenoid plug; none means a wiring or controller fault.
    4. 4Switch between the diverter positions from the cab and listen for the valve to shift at each change.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat 29-02High flow solenoid error ON

    The controller reads the flow solenoid error on signal above its normal range, which is usually a wire shorted to supply or a sensor that has failed high, so high flow is not available to the attachment.· Shorted high
    Check soon

    Causes

    • Signal wire shorted to the 5 V or battery supply
    • Sensor failed with its output pinned high
    • Ground wire open so the signal floats high
    • Water in the connector bridging signal to supply

    Checks

    1. 1Unplug the flow solenoid error on and measure the signal wire with the key on; a high voltage with the sensor removed means a short in the harness.
    2. 2Check the sensor ground at the plug; an open ground drives the signal high.
    3. 3Measure the 5 V reference at the flow solenoid error on plug to confirm it is not above 5 V.
    4. 4Run the attachment on standard flow and on high flow in turn, and compare the speed to confirm the solenoid is switching.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat 29-03High flow solenoid error OFF

    The controller reads the flow solenoid error off signal above its normal range, which is usually a wire shorted to supply or a sensor that has failed high, so high flow is not available to the attachment.· Shorted high
    Check soon

    Causes

    • Signal wire shorted to the 5 V or battery supply
    • Sensor failed with its output pinned high
    • Ground wire open so the signal floats high
    • Water in the connector bridging signal to supply

    Checks

    1. 1Unplug the flow solenoid error off and measure the signal wire with the key on; a high voltage with the sensor removed means a short in the harness.
    2. 2Check the sensor ground at the plug; an open ground drives the signal high.
    3. 3Measure the 5 V reference at the flow solenoid error off plug to confirm it is not above 5 V.
    4. 4Run the attachment on standard flow and on high flow in turn, and compare the speed to confirm the solenoid is switching.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat C1039-19High flow solenoid overcurrent

    The controller measured too much current on the high flow solenoid output and switched it off to protect its driver, so high flow is not available to the attachment until the overload is cleared.· Real condition
    Check soon

    Causes

    • Coil shorted between turns so it draws too much current
    • Wiring partly shorted to ground at the high flow solenoid connector
    • Wrong or damaged part fitted that loads the output

    Checks

    1. 1Measure the resistance of the high flow solenoid coil with the plug off and compare it with a matching part on the same machine.
    2. 2Check the high flow solenoid wire for a partial short to ground that only shows when the machine is hot or vibrating.
    3. 3Replace the part and clear the code; if it returns at once, suspect the controller output.
    4. 4Run the attachment on standard flow and on high flow in turn, and compare the speed to confirm the solenoid is switching.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Bobcat H2505Diverter solenoid #2 short to battery

    The controller reads the diverter solenoid 2 circuit tied to battery voltage when it should only be switched by the controller.· Shorted high
    Check soon

    Causes

    • Output wire rubbed through at the diverter valve connector and touching a live supply wire
    • Water or corrosion in the plug bridging a pin to a power pin
    • Controller output stage failed shorted to supply

    Checks

    1. 1Unplug the diverter solenoid 2 at the diverter valve connector and check its output wire for voltage with the key on; any voltage with the load removed is a short to supply.
    2. 2Trace the wire back from the diverter solenoid coil for chafing next to live supply wires and for melted insulation.
    3. 3Replace the diverter solenoid coil only if the wire reads clean and the part itself reads shorted.
    4. 4Switch between the diverter positions from the cab and listen for the valve to shift at each change.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat H2506Diverter solenoid #2 short to ground

    The controller reads the diverter solenoid 2 circuit pulled to ground, so it cannot drive the load.· Shorted low
    Check soon

    Causes

    • Wire chafed against the frame or a bracket at the diverter valve connector
    • The diverter solenoid coil shorted to its housing
    • Water in the connector or a pin touching the shell

    Checks

    1. 1With the plug off, test the diverter solenoid 2 output wire to chassis ground; a reading near zero shows a harness short.
    2. 2Measure from each pin of the diverter solenoid coil to its body; any continuity means the part itself is shorted.
    3. 3Look for harness sections crushed under clamps or cut by sharp edges at the diverter valve connector.
    4. 4Switch between the diverter positions from the cab and listen for the valve to shift at each change.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat H2805Diverter solenoid short to battery

    The controller reads the diverter solenoid circuit tied to battery voltage when it should only be switched by the controller.· Shorted high
    Check soon

    Causes

    • Output wire rubbed through at the diverter valve connector and touching a live supply wire
    • Water or corrosion in the plug bridging a pin to a power pin
    • Controller output stage failed shorted to supply

    Checks

    1. 1Unplug the diverter solenoid at the diverter valve connector and check its output wire for voltage with the key on; any voltage with the load removed is a short to supply.
    2. 2Trace the wire back from the diverter solenoid coil for chafing next to live supply wires and for melted insulation.
    3. 3Replace the diverter solenoid coil only if the wire reads clean and the part itself reads shorted.
    4. 4Switch between the diverter positions from the cab and listen for the valve to shift at each change.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat M2805Diverter output short to battery

    The controller reads the diverter output circuit tied to battery voltage when it should only be switched by the controller.· Shorted high
    Check soon

    Causes

    • Output wire rubbed through at the diverter valve connector and touching a live supply wire
    • Water or corrosion in the plug bridging a pin to a power pin
    • Controller output stage failed shorted to supply

    Checks

    1. 1Unplug the diverter output at the diverter valve connector and check its output wire for voltage with the key on; any voltage with the load removed is a short to supply.
    2. 2Trace the wire back from the diverter solenoid coil for chafing next to live supply wires and for melted insulation.
    3. 3Replace the diverter solenoid coil only if the wire reads clean and the part itself reads shorted.
    4. 4Switch between the diverter positions from the cab and listen for the valve to shift at each change.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat H2806Diverter solenoid short to ground

    The controller reads the diverter solenoid circuit pulled to ground, so it cannot drive the load.· Shorted low
    Check soon

    Causes

    • Wire chafed against the frame or a bracket at the diverter valve connector
    • The diverter solenoid coil shorted to its housing
    • Water in the connector or a pin touching the shell

    Checks

    1. 1With the plug off, test the diverter solenoid output wire to chassis ground; a reading near zero shows a harness short.
    2. 2Measure from each pin of the diverter solenoid coil to its body; any continuity means the part itself is shorted.
    3. 3Look for harness sections crushed under clamps or cut by sharp edges at the diverter valve connector.
    4. 4Switch between the diverter positions from the cab and listen for the valve to shift at each change.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat M2806Diverter output short to ground

    The controller reads the diverter output circuit pulled to ground, so it cannot drive the load.· Shorted low
    Check soon

    Causes

    • Wire chafed against the frame or a bracket at the diverter valve connector
    • The diverter solenoid coil shorted to its housing
    • Water in the connector or a pin touching the shell

    Checks

    1. 1With the plug off, test the diverter output output wire to chassis ground; a reading near zero shows a harness short.
    2. 2Measure from each pin of the diverter solenoid coil to its body; any continuity means the part itself is shorted.
    3. 3Look for harness sections crushed under clamps or cut by sharp edges at the diverter valve connector.
    4. 4Switch between the diverter positions from the cab and listen for the valve to shift at each change.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat H2807Diverter output open circuit

    Diverter output open circuit: same fault as M2807 (the circuit is open), here on the diverter output.· Open circuit
    Check soon

    Causes

    • Pin backed out of the connector or plug not latched
    • Wire broken inside its insulation

    Checks

    1. 1Check the diverter output connector is seated, then measure across the part for an open.
    2. 2Test steps: see M2807.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Bobcat M2807Diverter output open circuit

    The controller sees an open circuit on the diverter output, so no current can flow through it and the oil is not routed to the right circuit.· Open circuit
    Check soon

    Causes

    • Pin backed out of the connector or plug not latched at the diverter valve connector
    • Wire broken inside its insulation near a bend or clamp
    • The diverter solenoid coil burnt open or its internal lead broken

    Checks

    1. 1Check that the diverter output connector at the diverter valve connector is fully seated and its lock tab engaged.
    2. 2Measure the resistance of the diverter solenoid coil with the plug off; an infinite reading confirms an open.
    3. 3Check continuity of each wire from the diverter output plug back to the controller connector, flexing the harness as you go.
    4. 4Switch between the diverter positions from the cab and listen for the valve to shift at each change.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Bobcat H2832Diverter output overcurrent

    The controller measured too much current on the diverter output output and switched it off to protect its driver, so the oil is not routed to the right circuit until the overload is cleared.· Lost message
    Check soon

    Causes

    • Coil shorted between turns so it draws too much current
    • Wiring partly shorted to ground at the diverter valve connector
    • Wrong or damaged part fitted that loads the output

    Checks

    1. 1Measure the resistance of the diverter solenoid coil with the plug off and compare it with a matching part on the same machine.
    2. 2Check the diverter output wire for a partial short to ground that only shows when the machine is hot or vibrating.
    3. 3Replace the part and clear the code; if it returns at once, suspect the controller output.
    4. 4Switch between the diverter positions from the cab and listen for the valve to shift at each change.
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Bobcat H2848Diverter multiple input

    The controller reports multiple inputs at once on the diverter input, for example two directions active together, which a healthy control cannot do, so the oil is not routed to the right circuit.· Lost message
    Check soon

    Causes

    • Joystick or handle sensor failed
    • Shorted wires between two signal lines
    • Water in the connector

    Checks

    1. 1Release the control and read each axis on the service screen to find which one reads active.
    2. 2Unplug the diverter input connector and inspect the pins for water and bridging.
    3. 3Replace the the diverter solenoid coil if two axes read active with the control at rest.
    4. 4Switch between the diverter positions from the cab and listen for the valve to shift at each change.
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Bobcat H2905High flow solenoid short to battery

    The controller reads the high flow solenoid circuit tied to battery voltage when it should only be switched by the controller.· Shorted high
    Check soon

    Causes

    • Output wire rubbed through at the high flow solenoid connector and touching a live supply wire
    • Water or corrosion in the plug bridging a pin to a power pin
    • Controller output stage failed shorted to supply

    Checks

    1. 1Unplug the high flow solenoid at the high flow solenoid connector and check its output wire for voltage with the key on; any voltage with the load removed is a short to supply.
    2. 2Trace the wire back from the high flow solenoid coil for chafing next to live supply wires and for melted insulation.
    3. 3Replace the high flow solenoid coil only if the wire reads clean and the part itself reads shorted.
    4. 4Run the attachment on standard flow and on high flow in turn, and compare the speed to confirm the solenoid is switching.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat H2906High flow solenoid short to ground

    The controller reads the high flow solenoid circuit pulled to ground, so it cannot drive the load.· Shorted low
    Check soon

    Causes

    • Wire chafed against the frame or a bracket at the high flow solenoid connector
    • The high flow solenoid coil shorted to its housing
    • Water in the connector or a pin touching the shell

    Checks

    1. 1With the plug off, test the high flow solenoid output wire to chassis ground; a reading near zero shows a harness short.
    2. 2Measure from each pin of the high flow solenoid coil to its body; any continuity means the part itself is shorted.
    3. 3Look for harness sections crushed under clamps or cut by sharp edges at the high flow solenoid connector.
    4. 4Run the attachment on standard flow and on high flow in turn, and compare the speed to confirm the solenoid is switching.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat H2907High flow solenoid open circuit

    The controller sees an open circuit on the high flow solenoid, so no current can flow through it and high flow is not available to the attachment.· Open circuit
    Check soon

    Causes

    • Pin backed out of the connector or plug not latched at the high flow solenoid connector
    • Wire broken inside its insulation near a bend or clamp
    • The high flow solenoid coil burnt open or its internal lead broken

    Checks

    1. 1Check that the high flow solenoid connector at the high flow solenoid connector is fully seated and its lock tab engaged.
    2. 2Measure the resistance of the high flow solenoid coil with the plug off; an infinite reading confirms an open.
    3. 3Check continuity of each wire from the high flow solenoid plug back to the controller connector, flexing the harness as you go.
    4. 4Run the attachment on standard flow and on high flow in turn, and compare the speed to confirm the solenoid is switching.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Bobcat H2932High flow solenoid overcurrent

    High flow solenoid overcurrent: same fault as C1039-19 (the circuit draws more current than the driver allows), here on the high flow solenoid.· Other
    Check soon

    Causes

    • Coil shorted between turns so it draws too much current
    • Wiring partly shorted to ground

    Checks

    1. 1Measure the resistance of the high flow solenoid and compare it with a matching part.
    2. 2Test steps: see C1039-19.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

Shared checks

Checks, in order

  1. 1Switch between diverter positions and high flow from the cab and listen for each valve to shift.
  2. 2Measure the coil resistance of the named solenoid with the plug off and compare it with the other diverter solenoid.
  3. 3Measure voltage at the plug while the function is commanded; none points to the harness or controller output.
  4. 4Check the connector for water and bent pins, then clear the code and retest.
  5. 5Compare attachment speed on standard and high flow to confirm the solenoid is actually switching.

Causes

  • Diverter or high flow coil shorted or burnt open
  • Harness chafed along the boom to the valve
  • Connector at the diverter block corroded
  • Valve spool sticking from contaminated oil

Most common here: shorted high (6 of 19)

Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

When to stop

You'll notice: The attachment gets oil from the wrong circuit, runs weakly without high flow, or keeps high flow on when it is not wanted.

Lower attachments to the ground and relieve hydraulic pressure before loosening any fitting. Never feel for a leak with your hand - oil under pressure can inject through skin.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.