Bobcat · Auxiliary hydraulics
Bobcat Attachment output solenoids (A to H) fault codes
Attachment outputs A to H are the coil and valve outputs the attachment controller uses to run the functions of a multi-function attachment, one letter per output. A code gives the output letter and the failure: error on, error off, short to battery, short to ground, open circuit or overcurrent.
More about these partsLess
The ACD (attachment control device) outputs repeat the same faults with an H prefix.
Where this code shows
On touchscreen R-series machines, touch the screen and pick Service Codes from the menu.
What do these codes mean?
Bobcat codes A8002 to A8707 are all about the attachment output solenoids (A to H). The most common failure type is shorted low (9 of 62); none needs an immediate stop. Start with this check: find the output letter named by the code and the matching pin on the attachment connector before measuring anything.
How urgent are they?
None of the 62 codes here means stop now; all 62 can wait until the shift ends, but find the cause before the next one.
- Check soon62
What should I check first?
Find the output letter named by the code and the matching pin on the attachment connector before measuring anything.
Shared checks62 of 62
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
Bobcat A8002Output a error on
The controller sees the attachment output switched on when it was commanded off, so the attachment function stays active. The driver, relay or wiring is holding it on.· OtherOtherCheck soonCauses
- Output wire shorted to a live supply
- Relay or driver stuck closed
- Controller output stage failed and cannot switch off
Checks
- 1Unplug the attachment output at the attachment connector on the hitch with the key on; if the controller still reads it on, the fault is in the wiring or controller.
- 2Check the output wire for contact with a power wire along its run.
- 3Listen and feel for the attachment coil energising while it should be off.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat H8002ACD output a error on
ACD output a error on: same fault as A8002 (the output reads on when it should be off), here on the output a.· OtherOtherCheck soonCauses
- Output wire shorted to a live supply
- Relay or driver stuck closed
Checks
- 1Unplug the output a with the key on and see whether the controller still reads it on.
- 2Test steps: see A8002.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat A8003Output a error off
The controller sees the attachment output off when it was commanded on, so the attachment function driven by that output does not respond. The circuit is open, shorted to ground or not being driven.· Shorted lowShorted lowCheck soonCauses
- Open or grounded output wire
- The attachment coil failed open
- Blown fuse or missing supply to the circuit
Checks
- 1Check the fuse and supply to the attachment output circuit with the key on.
- 2Measure the resistance of the attachment coil and look for an open or a short to its body.
- 3Command the function and measure voltage at the attachment output plug; none means a wiring or controller fault.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat H8003ACD output a error off
ACD output a error off: same fault as A8003 (the output reads off when it was commanded on), here on the output a.· OtherOtherCheck soonCauses
- Open or grounded output wire
- The attachment coil failed open
Checks
- 1Check the fuse and the supply voltage at the output a plug with the output commanded.
- 2Test steps: see A8003.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat A8005Output a short to battery
The controller reads the attachment output circuit tied to battery voltage when it should only be switched by the controller. It shuts the output off to protect its driver, so the attachment function driven by that output does not respond.· Shorted highShorted highCheck soonCauses
- Output wire rubbed through at the attachment connector on the hitch and touching a live supply wire
- Water or corrosion in the plug bridging a pin to a power pin
- Controller output stage failed shorted to supply
Checks
- 1Unplug the attachment output at the attachment connector on the hitch and check its output wire for voltage with the key on; any voltage with the load removed is a short to supply.
- 2Trace the wire back from the attachment coil for chafing next to live supply wires and for melted insulation.
- 3Replace the attachment coil only if the wire reads clean and the part itself reads shorted.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Bobcat A8006Output a short to ground
The controller reads the attachment output circuit pulled to ground, so it cannot drive the load. The output is shut off and the attachment function driven by that output does not respond until the short is cleared.· Shorted lowShorted lowCheck soonCauses
- Wire chafed against the frame or a bracket at the attachment connector on the hitch
- The attachment coil shorted to its housing
- Water in the connector or a pin touching the shell
Checks
- 1With the plug off, test the attachment output output wire to chassis ground; a reading near zero shows a harness short.
- 2Measure from each pin of the attachment coil to its body; any continuity means the part itself is shorted.
- 3Look for harness sections crushed under clamps or cut by sharp edges at the attachment connector on the hitch.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat A8007Output a open circuit
The controller sees an open circuit on the attachment output, so no current can flow through it and the attachment function driven by that output does not respond. The break is in the wire, the connector or the part itself.· Open circuitOpen circuitCheck soonCauses
- Pin backed out of the connector or plug not latched at the attachment connector on the hitch
- Wire broken inside its insulation near a bend or clamp
- The attachment coil burnt open or its internal lead broken
Checks
- 1Check that the attachment output connector at the attachment connector on the hitch is fully seated and its lock tab engaged.
- 2Measure the resistance of the attachment coil with the plug off; an infinite reading confirms an open.
- 3Check continuity of each wire from the attachment output plug back to the controller connector, flexing the harness as you go.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat A8032Output a overcurrent
The controller measured too much current on the attachment output output and switched it off to protect its driver, so the attachment function driven by that output does not respond until the overload is cleared.· Real conditionReal conditionCheck soonCauses
- Coil shorted between turns so it draws too much current
- Wiring partly shorted to ground at the attachment connector on the hitch
- Wrong or damaged part fitted that loads the output
Checks
- 1Measure the resistance of the attachment coil with the plug off and compare it with a matching part on the same machine.
- 2Check the attachment output wire for a partial short to ground that only shows when the machine is hot or vibrating.
- 3Replace the part and clear the code; if it returns at once, suspect the controller output.
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Bobcat A8102Output b error on
Output b error on: same fault as A8002 (the output reads on when it should be off), here on the output b.· OtherOtherCheck soonCauses
- Output wire shorted to a live supply
- Relay or driver stuck closed
Checks
- 1Unplug the output b with the key on and see whether the controller still reads it on.
- 2Test steps: see A8002.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat H8102ACD output b error on
ACD output b error on: same fault as A8002 (the output reads on when it should be off), here on the output b.· OtherOtherCheck soonCauses
- Output wire shorted to a live supply
- Relay or driver stuck closed
Checks
- 1Unplug the output b with the key on and see whether the controller still reads it on.
- 2Test steps: see A8002.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat A8103Output b error off
Output b error off: same fault as A8003 (the output reads off when it was commanded on), here on the output b.· OtherOtherCheck soonCauses
- Open or grounded output wire
- The attachment coil failed open
Checks
- 1Check the fuse and the supply voltage at the output b plug with the output commanded.
- 2Test steps: see A8003.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat H8103ACD output b error off
ACD output b error off: same fault as A8003 (the output reads off when it was commanded on), here on the output b.· OtherOtherCheck soonCauses
- Open or grounded output wire
- The attachment coil failed open
Checks
- 1Check the fuse and the supply voltage at the output b plug with the output commanded.
- 2Test steps: see A8003.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat A8105Output b short to battery
Output b short to battery: same fault as A8005 (the circuit reads tied to battery voltage), here on the output b.· Shorted highShorted highCheck soonCauses
- Output wire rubbed through
- Water or corrosion in the plug bridging a pin to a power pin
Checks
- 1Unplug the output b and look for voltage on its output wire with the key on.
- 2Test steps: see A8005.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Bobcat A8106Output b short to ground
Output b short to ground: same fault as A8006 (the circuit reads pulled to ground), here on the output b.· Shorted lowShorted lowCheck soonCauses
- Wire chafed against the frame or a bracket
- The attachment coil shorted to its housing
Checks
- 1Test the output b output wire to chassis ground with the plug off.
- 2Test steps: see A8006.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat A8107Output b open circuit
Output b open circuit: same fault as A8007 (the circuit is open), here on the output b.· Open circuitOpen circuitCheck soonCauses
- Pin backed out of the connector or plug not latched
- Wire broken inside its insulation
Checks
- 1Check the output b connector is seated, then measure across the part for an open.
- 2Test steps: see A8007.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat A8132Output b overcurrent
Output b overcurrent: same fault as A8032 (the circuit draws more current than the driver allows), here on the output b.· OtherOtherCheck soonCauses
- Coil shorted between turns so it draws too much current
- Wiring partly shorted to ground
Checks
- 1Measure the resistance of the output b and compare it with a matching part.
- 2Test steps: see A8032.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat A8202Output c error on
Output c error on: same fault as A8002 (the output reads on when it should be off), here on the output c.· OtherOtherCheck soonCauses
- Output wire shorted to a live supply
- Relay or driver stuck closed
Checks
- 1Unplug the output c with the key on and see whether the controller still reads it on.
- 2Test steps: see A8002.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat H8202ACD output c error on
ACD output c error on: same fault as A8002 (the output reads on when it should be off), here on the output c.· OtherOtherCheck soonCauses
- Output wire shorted to a live supply
- Relay or driver stuck closed
Checks
- 1Unplug the output c with the key on and see whether the controller still reads it on.
- 2Test steps: see A8002.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat A8203Output c error off
Output c error off: same fault as A8003 (the output reads off when it was commanded on), here on the output c.· OtherOtherCheck soonCauses
- Open or grounded output wire
- The attachment coil failed open
Checks
- 1Check the fuse and the supply voltage at the output c plug with the output commanded.
- 2Test steps: see A8003.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat H8203ACD output c error off
ACD output c error off: same fault as A8003 (the output reads off when it was commanded on), here on the output c.· OtherOtherCheck soonCauses
- Open or grounded output wire
- The attachment coil failed open
Checks
- 1Check the fuse and the supply voltage at the output c plug with the output commanded.
- 2Test steps: see A8003.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat A8205Output c short to battery
Output c short to battery: same fault as A8005 (the circuit reads tied to battery voltage), here on the output c.· Shorted highShorted highCheck soonCauses
- Output wire rubbed through
- Water or corrosion in the plug bridging a pin to a power pin
Checks
- 1Unplug the output c and look for voltage on its output wire with the key on.
- 2Test steps: see A8005.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Bobcat A8206Output c short to ground
Output c short to ground: same fault as A8006 (the circuit reads pulled to ground), here on the output c.· Shorted lowShorted lowCheck soonCauses
- Wire chafed against the frame or a bracket
- The attachment coil shorted to its housing
Checks
- 1Test the output c output wire to chassis ground with the plug off.
- 2Test steps: see A8006.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat A8207Output c open circuit
Output c open circuit: same fault as A8007 (the circuit is open), here on the output c.· Open circuitOpen circuitCheck soonCauses
- Pin backed out of the connector or plug not latched
- Wire broken inside its insulation
Checks
- 1Check the output c connector is seated, then measure across the part for an open.
- 2Test steps: see A8007.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat A8232Output c overcurrent
Output c overcurrent: same fault as A8032 (the circuit draws more current than the driver allows), here on the output c.· OtherOtherCheck soonCauses
- Coil shorted between turns so it draws too much current
- Wiring partly shorted to ground
Checks
- 1Measure the resistance of the output c and compare it with a matching part.
- 2Test steps: see A8032.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat A8302Output d error on
Output d error on: same fault as A8002 (the output reads on when it should be off), here on the output d.· OtherOtherCheck soonCauses
- Output wire shorted to a live supply
- Relay or driver stuck closed
Checks
- 1Unplug the output d with the key on and see whether the controller still reads it on.
- 2Test steps: see A8002.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat H8302ACD output d error on
ACD output d error on: same fault as A8002 (the output reads on when it should be off), here on the output d.· OtherOtherCheck soonCauses
- Output wire shorted to a live supply
- Relay or driver stuck closed
Checks
- 1Unplug the output d with the key on and see whether the controller still reads it on.
- 2Test steps: see A8002.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat A8303Output d error off
Output d error off: same fault as A8003 (the output reads off when it was commanded on), here on the output d.· OtherOtherCheck soonCauses
- Open or grounded output wire
- The attachment coil failed open
Checks
- 1Check the fuse and the supply voltage at the output d plug with the output commanded.
- 2Test steps: see A8003.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat H8303ACD output d error off
ACD output d error off: same fault as A8003 (the output reads off when it was commanded on), here on the output d.· OtherOtherCheck soonCauses
- Open or grounded output wire
- The attachment coil failed open
Checks
- 1Check the fuse and the supply voltage at the output d plug with the output commanded.
- 2Test steps: see A8003.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat A8305Output d short to battery
Output d short to battery: same fault as A8005 (the circuit reads tied to battery voltage), here on the output d.· Shorted highShorted highCheck soonCauses
- Output wire rubbed through
- Water or corrosion in the plug bridging a pin to a power pin
Checks
- 1Unplug the output d and look for voltage on its output wire with the key on.
- 2Test steps: see A8005.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Bobcat A8306Output d short to ground
Output d short to ground: same fault as A8006 (the circuit reads pulled to ground), here on the output d.· Shorted lowShorted lowCheck soonCauses
- Wire chafed against the frame or a bracket
- The attachment coil shorted to its housing
Checks
- 1Test the output d output wire to chassis ground with the plug off.
- 2Test steps: see A8006.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat A8307Output d open circuit
Output d open circuit: same fault as A8007 (the circuit is open), here on the output d.· Open circuitOpen circuitCheck soonCauses
- Pin backed out of the connector or plug not latched
- Wire broken inside its insulation
Checks
- 1Check the output d connector is seated, then measure across the part for an open.
- 2Test steps: see A8007.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat A8332Output d overcurrent
Output d overcurrent: same fault as A8032 (the circuit draws more current than the driver allows), here on the output d.· OtherOtherCheck soonCauses
- Coil shorted between turns so it draws too much current
- Wiring partly shorted to ground
Checks
- 1Measure the resistance of the output d and compare it with a matching part.
- 2Test steps: see A8032.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat A8402Output e error on
Output e error on: same fault as A8002 (the output reads on when it should be off), here on the output e.· OtherOtherCheck soonCauses
- Output wire shorted to a live supply
- Relay or driver stuck closed
Checks
- 1Unplug the output e with the key on and see whether the controller still reads it on.
- 2Test steps: see A8002.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat H8402ACD output e error on
ACD output e error on: same fault as A8002 (the output reads on when it should be off), here on the output e.· OtherOtherCheck soonCauses
- Output wire shorted to a live supply
- Relay or driver stuck closed
Checks
- 1Unplug the output e with the key on and see whether the controller still reads it on.
- 2Test steps: see A8002.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat A8403Output e error off
Output e error off: same fault as A8003 (the output reads off when it was commanded on), here on the output e.· OtherOtherCheck soonCauses
- Open or grounded output wire
- The attachment coil failed open
Checks
- 1Check the fuse and the supply voltage at the output e plug with the output commanded.
- 2Test steps: see A8003.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat H8403ACD output e error off
ACD output e error off: same fault as A8003 (the output reads off when it was commanded on), here on the output e.· OtherOtherCheck soonCauses
- Open or grounded output wire
- The attachment coil failed open
Checks
- 1Check the fuse and the supply voltage at the output e plug with the output commanded.
- 2Test steps: see A8003.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat A8405Output e short to battery
Output e short to battery: same fault as A8005 (the circuit reads tied to battery voltage), here on the output e.· Shorted highShorted highCheck soonCauses
- Output wire rubbed through
- Water or corrosion in the plug bridging a pin to a power pin
Checks
- 1Unplug the output e and look for voltage on its output wire with the key on.
- 2Test steps: see A8005.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Bobcat A8406Output e short to ground
Output e short to ground: same fault as A8006 (the circuit reads pulled to ground), here on the output e.· Shorted lowShorted lowCheck soonCauses
- Wire chafed against the frame or a bracket
- The attachment coil shorted to its housing
Checks
- 1Test the output e output wire to chassis ground with the plug off.
- 2Test steps: see A8006.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat A8407Output e open circuit
Output e open circuit: same fault as A8007 (the circuit is open), here on the output e.· Open circuitOpen circuitCheck soonCauses
- Pin backed out of the connector or plug not latched
- Wire broken inside its insulation
Checks
- 1Check the output e connector is seated, then measure across the part for an open.
- 2Test steps: see A8007.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat A8432Output e overcurrent
Output e overcurrent: same fault as A8032 (the circuit draws more current than the driver allows), here on the output e.· OtherOtherCheck soonCauses
- Coil shorted between turns so it draws too much current
- Wiring partly shorted to ground
Checks
- 1Measure the resistance of the output e and compare it with a matching part.
- 2Test steps: see A8032.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat A8502Output f error on
Output f error on: same fault as A8002 (the output reads on when it should be off), here on the output f.· OtherOtherCheck soonCauses
- Output wire shorted to a live supply
- Relay or driver stuck closed
Checks
- 1Unplug the output f with the key on and see whether the controller still reads it on.
- 2Test steps: see A8002.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat H8502ACD output f error on
ACD output f error on: same fault as A8002 (the output reads on when it should be off), here on the output f.· OtherOtherCheck soonCauses
- Output wire shorted to a live supply
- Relay or driver stuck closed
Checks
- 1Unplug the output f with the key on and see whether the controller still reads it on.
- 2Test steps: see A8002.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat A8503Output f error off
Output f error off: same fault as A8003 (the output reads off when it was commanded on), here on the output f.· OtherOtherCheck soonCauses
- Open or grounded output wire
- The attachment coil failed open
Checks
- 1Check the fuse and the supply voltage at the output f plug with the output commanded.
- 2Test steps: see A8003.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat H8503ACD output f error off
ACD output f error off: same fault as A8003 (the output reads off when it was commanded on), here on the output f.· OtherOtherCheck soonCauses
- Open or grounded output wire
- The attachment coil failed open
Checks
- 1Check the fuse and the supply voltage at the output f plug with the output commanded.
- 2Test steps: see A8003.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat A8505Output f short to battery
Output f short to battery: same fault as A8005 (the circuit reads tied to battery voltage), here on the output f.· Shorted highShorted highCheck soonCauses
- Output wire rubbed through
- Water or corrosion in the plug bridging a pin to a power pin
Checks
- 1Unplug the output f and look for voltage on its output wire with the key on.
- 2Test steps: see A8005.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Bobcat A8506Output f short to ground
Output f short to ground: same fault as A8006 (the circuit reads pulled to ground), here on the output f.· Shorted lowShorted lowCheck soonCauses
- Wire chafed against the frame or a bracket
- The attachment coil shorted to its housing
Checks
- 1Test the output f output wire to chassis ground with the plug off.
- 2Test steps: see A8006.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat A8507Output f open circuit
Output f open circuit: same fault as A8007 (the circuit is open), here on the output f.· Open circuitOpen circuitCheck soonCauses
- Pin backed out of the connector or plug not latched
- Wire broken inside its insulation
Checks
- 1Check the output f connector is seated, then measure across the part for an open.
- 2Test steps: see A8007.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat A8532Output f overcurrent
Output f overcurrent: same fault as A8032 (the circuit draws more current than the driver allows), here on the output f.· OtherOtherCheck soonCauses
- Coil shorted between turns so it draws too much current
- Wiring partly shorted to ground
Checks
- 1Measure the resistance of the output f and compare it with a matching part.
- 2Test steps: see A8032.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat A8602Output g error on
Output g error on: same fault as A8002 (the output reads on when it should be off), here on the output g.· OtherOtherCheck soonCauses
- Output wire shorted to a live supply
- Relay or driver stuck closed
Checks
- 1Unplug the output g with the key on and see whether the controller still reads it on.
- 2Test steps: see A8002.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat H8602ACD output g error on
ACD output g error on: same fault as A8002 (the output reads on when it should be off), here on the output g.· OtherOtherCheck soonCauses
- Output wire shorted to a live supply
- Relay or driver stuck closed
Checks
- 1Unplug the output g with the key on and see whether the controller still reads it on.
- 2Test steps: see A8002.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat A8603Output g error off
Output g error off: same fault as A8003 (the output reads off when it was commanded on), here on the output g.· OtherOtherCheck soonCauses
- Open or grounded output wire
- The attachment coil failed open
Checks
- 1Check the fuse and the supply voltage at the output g plug with the output commanded.
- 2Test steps: see A8003.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat H8603ACD output g error off
ACD output g error off: same fault as A8003 (the output reads off when it was commanded on), here on the output g.· OtherOtherCheck soonCauses
- Open or grounded output wire
- The attachment coil failed open
Checks
- 1Check the fuse and the supply voltage at the output g plug with the output commanded.
- 2Test steps: see A8003.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat A8605Output g short to battery
Output g short to battery: same fault as A8005 (the circuit reads tied to battery voltage), here on the output g.· Shorted highShorted highCheck soonCauses
- Output wire rubbed through
- Water or corrosion in the plug bridging a pin to a power pin
Checks
- 1Unplug the output g and look for voltage on its output wire with the key on.
- 2Test steps: see A8005.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Bobcat A8606Output g short to ground
Output g short to ground: same fault as A8006 (the circuit reads pulled to ground), here on the output g.· Shorted lowShorted lowCheck soonCauses
- Wire chafed against the frame or a bracket
- The attachment coil shorted to its housing
Checks
- 1Test the output g output wire to chassis ground with the plug off.
- 2Test steps: see A8006.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat A8607Output g open circuit
Output g open circuit: same fault as A8007 (the circuit is open), here on the output g.· Open circuitOpen circuitCheck soonCauses
- Pin backed out of the connector or plug not latched
- Wire broken inside its insulation
Checks
- 1Check the output g connector is seated, then measure across the part for an open.
- 2Test steps: see A8007.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat A8702Output h error on
Output h error on: same fault as A8002 (the output reads on when it should be off), here on the output h.· OtherOtherCheck soonCauses
- Output wire shorted to a live supply
- Relay or driver stuck closed
Checks
- 1Unplug the output h with the key on and see whether the controller still reads it on.
- 2Test steps: see A8002.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat H8702ACD output h error on
ACD output h error on: same fault as A8002 (the output reads on when it should be off), here on the output h.· OtherOtherCheck soonCauses
- Output wire shorted to a live supply
- Relay or driver stuck closed
Checks
- 1Unplug the output h with the key on and see whether the controller still reads it on.
- 2Test steps: see A8002.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat A8703Output h error off
Output h error off: same fault as A8003 (the output reads off when it was commanded on), here on the output h.· OtherOtherCheck soonCauses
- Open or grounded output wire
- The attachment coil failed open
Checks
- 1Check the fuse and the supply voltage at the output h plug with the output commanded.
- 2Test steps: see A8003.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat H8703ACD output h error off
ACD output h error off: same fault as A8003 (the output reads off when it was commanded on), here on the output h.· OtherOtherCheck soonCauses
- Open or grounded output wire
- The attachment coil failed open
Checks
- 1Check the fuse and the supply voltage at the output h plug with the output commanded.
- 2Test steps: see A8003.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat A8705Output h short to battery
Output h short to battery: same fault as A8005 (the circuit reads tied to battery voltage), here on the output h.· Shorted highShorted highCheck soonCauses
- Output wire rubbed through
- Water or corrosion in the plug bridging a pin to a power pin
Checks
- 1Unplug the output h and look for voltage on its output wire with the key on.
- 2Test steps: see A8005.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Bobcat A8706Output h short to ground
Output h short to ground: same fault as A8006 (the circuit reads pulled to ground), here on the output h.· Shorted lowShorted lowCheck soonCauses
- Wire chafed against the frame or a bracket
- The attachment coil shorted to its housing
Checks
- 1Test the output h output wire to chassis ground with the plug off.
- 2Test steps: see A8006.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat A8707Output h open circuit
Output h open circuit: same fault as A8007 (the circuit is open), here on the output h.· Open circuitOpen circuitCheck soonCauses
- Pin backed out of the connector or plug not latched
- Wire broken inside its insulation
Checks
- 1Check the output h connector is seated, then measure across the part for an open.
- 2Test steps: see A8007.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Shared checks
Checks, in order
- 1Find the output letter named by the code and the matching pin on the attachment connector before measuring anything.
- 2Unplug the attachment and check the output wire for voltage with the key on; any voltage with the load removed is a short to supply.
- 3Measure resistance across the attachment coil with the plug off and compare it with a matching good coil.
- 4Check the output wire to chassis ground with the plug off; a reading near zero shows a harness short.
- 5Clear the code, reconnect, command the output again and watch whether the code returns at once or only when warm.
Causes
- Coil in the attachment shorted or burnt open
- Output wire chafed or crushed at the hitch or attachment connector
- Connector pin backed out, corroded or full of water
- Controller output stage failed after a short
Most common here: shorted low (9 of 62)
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
When to stop
You'll notice: An attachment function does not respond, stays on, or the controller switches the output off to protect its driver; the code names the output letter that failed.
Lower attachments to the ground and relieve hydraulic pressure before loosening any fitting. Never feel for a leak with your hand - oil under pressure can inject through skin.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.