Bobcat · Operator presence
Bobcat Control switches, remote control and jog shuttle fault codes
The jog shuttle, the remote control and the control switches for the angle blade, offset boom, excavator auxiliary hydraulics and front auxiliary PWM are driver inputs read by the controller. A code names the switch and whether the controller sees it stuck, open or not responding.
Where this code shows
On touchscreen R-series machines, touch the screen and pick Service Codes from the menu.
What do these codes mean?
Bobcat codes U10D0-08 to M7316 are all about the control switches, remote control and jog shuttle. The most common failure type is lost message (6 of 25); none needs an immediate stop. Start with this check: press each switch while watching its state on the service screen to find which one reads wrong.
How urgent are they?
None of the 25 codes here means stop now; all 25 can wait until the shift ends, but find the cause before the next one.
- Check soon25
What should I check first?
Press each switch while watching its state on the service screen to find which one reads wrong.
Shared checks25 of 25
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
Bobcat U10D0-08Remote control no communication
Remote control no communication: same fault as M7304 (the controller lost communication), here on the remote control.· Lost messageLost messageCheck soonCauses
- Supply or ground to the unit missing
- Data wire chafed, open or shorted
Checks
- 1Measure supply and ground at the remote control connector and check its data wires.
- 2Test steps: see M7304.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Bobcat U10D0-93Remote control loss communication
Remote control loss communication: same fault as M7304 (the controller lost communication), here on the remote control.· Lost messageLost messageCheck soonCauses
- Supply or ground to the unit missing
- Data wire chafed, open or shorted
Checks
- 1Measure supply and ground at the remote control connector and check its data wires.
- 2Test steps: see M7304.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Bobcat 12-21Front auxiliary PWM switch out of range high
The controller reads the front auxiliary pwm switch signal above its normal range, which is usually a wire shorted to supply or a sensor that has failed high, so the function the switch selects cannot be used.· Shorted highShorted highCheck soonCauses
- Signal wire shorted to the 5 V or battery supply
- Sensor failed with its output pinned high
- Ground wire open so the signal floats high
- Water in the connector bridging signal to supply
Checks
- 1Unplug the front auxiliary pwm switch and measure the signal wire with the key on; a high voltage with the sensor removed means a short in the harness.
- 2Check the sensor ground at the plug; an open ground drives the signal high.
- 3Measure the 5 V reference at the front auxiliary pwm switch plug to confirm it is not above 5 V.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Bobcat 12-22Front auxiliary PWM switch out of range low
The controller reads the front auxiliary pwm switch signal below its normal range, typically a wire shorted to ground, an open supply or a sensor failed low, so the function the switch selects cannot be used.· Shorted lowShorted lowCheck soonCauses
- Signal wire shorted to ground
- Supply wire to the sensor open or the sensor not powered
- Sensor failed with its output pinned low
- Pin backed out of the connector
Checks
- 1Measure the 5 V reference at the front auxiliary pwm switch plug; no reference means the fault is in the supply wire, not the sensor.
- 2Unplug the sensor and measure the signal wire to ground for a short.
- 3Check the connector at the switch connector in the armrest or console for a backed-out pin.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat 12-23Front auxiliary PWM switch not in neutral
The controller sees the front auxiliary pwm switch away from neutral when it should be at rest, so the function the switch selects cannot be used. A sticking part or a drifting sensor holds it off neutral.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Part held off neutral by dirt or a bent linkage
- Sensor drifted or out of calibration
- Spring weak or broken
- Operator control held while starting
Checks
- 1Release the control fully and read the front auxiliary pwm switch value on the service screen; it should sit at neutral.
- 2Check the linkage and return spring for binding.
- 3Recalibrate the neutral position if the part moves freely but still reads off neutral.
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Bobcat H2521Angle blade control switch out of range high
The controller reads the control switch signal above its normal range, which is usually a wire shorted to supply or a sensor that has failed high, so the function the switch selects cannot be used.· Shorted highShorted highCheck soonCauses
- Signal wire shorted to the 5 V or battery supply
- Sensor failed with its output pinned high
- Ground wire open so the signal floats high
- Water in the connector bridging signal to supply
Checks
- 1Unplug the control switch and measure the signal wire with the key on; a high voltage with the sensor removed means a short in the harness.
- 2Check the sensor ground at the plug; an open ground drives the signal high.
- 3Measure the 5 V reference at the control switch plug to confirm it is not above 5 V.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Bobcat H2522Angle blade control switch out of range low
The controller reads the control switch signal below its normal range, typically a wire shorted to ground, an open supply or a sensor failed low, so the function the switch selects cannot be used.· Shorted lowShorted lowCheck soonCauses
- Signal wire shorted to ground
- Supply wire to the sensor open or the sensor not powered
- Sensor failed with its output pinned low
- Pin backed out of the connector
Checks
- 1Measure the 5 V reference at the control switch plug; no reference means the fault is in the supply wire, not the sensor.
- 2Unplug the sensor and measure the signal wire to ground for a short.
- 3Check the connector at the switch connector in the armrest or console for a backed-out pin.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat H2524Angle blade control switch out of neutral
The controller sees the control switch away from neutral when it should be at rest, so the function the switch selects cannot be used. A sticking part or a drifting sensor holds it off neutral.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Part held off neutral by dirt or a bent linkage
- Sensor drifted or out of calibration
- Spring weak or broken
- Operator control held while starting
Checks
- 1Release the control fully and read the control switch value on the service screen; it should sit at neutral.
- 2Check the linkage and return spring for binding.
- 3Recalibrate the neutral position if the part moves freely but still reads off neutral.
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Bobcat M3904Jog shuttle no communication
The controller has lost communication with the jog shuttle, so the jog shuttle does not scroll or select in the menu. A power, ground or data wire problem on the link looks the same as a failed unit.· Lost messageLost messageCheck soonCauses
- Supply or ground to the unit missing
- Data wire chafed, open or shorted
- Unit failed or not programmed
- Connector corroded at the jog shuttle connector
Checks
- 1Measure supply and ground at the jog shuttle connector with the key on.
- 2Check the data wires for continuity and shorts, flexing the harness at the jog shuttle connector.
- 3Reseat the connector and clear the code to see whether communication returns.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Bobcat R3904Jog shuttle no communication
Jog shuttle no communication: same fault as M3904 (the controller lost communication), here on the jog shuttle.· Lost messageLost messageCheck soonCauses
- Supply or ground to the unit missing
- Data wire chafed, open or shorted
Checks
- 1Measure supply and ground at the jog shuttle connector and check its data wires.
- 2Test steps: see M3904.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Bobcat M5421Offset control switch out of range high
Offset control switch out of range high: same fault as H2521 (the signal is above its normal range), here on the offset control switch.· OtherOtherCheck soonCauses
- Signal wire shorted to the 5 V or battery supply
- Sensor failed with its output pinned high
Checks
- 1Unplug the offset control switch and measure the signal wire for a short to supply.
- 2Test steps: see H2521.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat M5422Offset control switch out of range low
Offset control switch out of range low: same fault as H2522 (the signal is below its normal range), here on the offset control switch.· OtherOtherCheck soonCauses
- Signal wire shorted to ground
- Supply wire to the sensor open or the sensor not powered
Checks
- 1Measure the 5 V reference and the signal wire to ground at the offset control switch plug.
- 2Test steps: see H2522.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat M5424Offset control switch out of neutral
Offset control switch out of neutral: same fault as H2524 (the input reads away from neutral), here on the offset control switch.· OtherOtherCheck soonCauses
- Part held off neutral by dirt or a bent linkage
- Sensor drifted or out of calibration
Checks
- 1Release the control and read the offset control switch value on the service screen.
- 2Test steps: see H2524.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat M5721Auxiliary control switch out of range high
Auxiliary control switch out of range high: same fault as H2521 (the signal is above its normal range), here on the auxiliary control switch.· OtherOtherCheck soonCauses
- Signal wire shorted to the 5 V or battery supply
- Sensor failed with its output pinned high
Checks
- 1Unplug the auxiliary control switch and measure the signal wire for a short to supply.
- 2Test steps: see H2521.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat M5722Auxiliary control switch out of range low
Auxiliary control switch out of range low: same fault as H2522 (the signal is below its normal range), here on the auxiliary control switch.· OtherOtherCheck soonCauses
- Signal wire shorted to ground
- Supply wire to the sensor open or the sensor not powered
Checks
- 1Measure the 5 V reference and the signal wire to ground at the auxiliary control switch plug.
- 2Test steps: see H2522.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat M5724Auxiliary control switch out of neutral
Auxiliary control switch out of neutral: same fault as H2524 (the input reads away from neutral), here on the auxiliary control switch.· OtherOtherCheck soonCauses
- Part held off neutral by dirt or a bent linkage
- Sensor drifted or out of calibration
Checks
- 1Release the control and read the auxiliary control switch value on the service screen.
- 2Test steps: see H2524.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat M6021Left control switch out of range high
Left control switch out of range high: same fault as H2521 (the signal is above its normal range), here on the left control switch.· OtherOtherCheck soonCauses
- Signal wire shorted to the 5 V or battery supply
- Sensor failed with its output pinned high
Checks
- 1Unplug the left control switch and measure the signal wire for a short to supply.
- 2Test steps: see H2521.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat M6022Left control switch out of range low
Left control switch out of range low: same fault as H2522 (the signal is below its normal range), here on the left control switch.· OtherOtherCheck soonCauses
- Signal wire shorted to ground
- Supply wire to the sensor open or the sensor not powered
Checks
- 1Measure the 5 V reference and the signal wire to ground at the left control switch plug.
- 2Test steps: see H2522.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat M6024Left control switch out of neutral
Left control switch out of neutral: same fault as H2524 (the input reads away from neutral), here on the left control switch.· OtherOtherCheck soonCauses
- Part held off neutral by dirt or a bent linkage
- Sensor drifted or out of calibration
Checks
- 1Release the control and read the left control switch value on the service screen.
- 2Test steps: see H2524.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat M6121Right control switch out of range high
Right control switch out of range high: same fault as H2521 (the signal is above its normal range), here on the right control switch.· OtherOtherCheck soonCauses
- Signal wire shorted to the 5 V or battery supply
- Sensor failed with its output pinned high
Checks
- 1Unplug the right control switch and measure the signal wire for a short to supply.
- 2Test steps: see H2521.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat M6122Right control switch out of range low
Right control switch out of range low: same fault as H2522 (the signal is below its normal range), here on the right control switch.· OtherOtherCheck soonCauses
- Signal wire shorted to ground
- Supply wire to the sensor open or the sensor not powered
Checks
- 1Measure the 5 V reference and the signal wire to ground at the right control switch plug.
- 2Test steps: see H2522.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat M6124Right control switch out of neutral
Right control switch out of neutral: same fault as H2524 (the input reads away from neutral), here on the right control switch.· OtherOtherCheck soonCauses
- Part held off neutral by dirt or a bent linkage
- Sensor drifted or out of calibration
Checks
- 1Release the control and read the right control switch value on the service screen.
- 2Test steps: see H2524.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat M7304Remote control no communication
The controller has lost communication with the remote control, so the remote control does not respond. A power, ground or data wire problem on the link looks the same as a failed unit.· Lost messageLost messageCheck soonCauses
- Supply or ground to the unit missing
- Data wire chafed, open or shorted
- Unit failed or not programmed
- Connector corroded at the remote receiver connector
Checks
- 1Measure supply and ground at the remote control connector with the key on.
- 2Check the data wires for continuity and shorts, flexing the harness at the remote receiver connector.
- 3Reseat the connector and clear the code to see whether communication returns.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Bobcat W7304Remote control no communication
Remote control no communication: same fault as M7304 (the controller lost communication), here on the remote control.· Lost messageLost messageCheck soonCauses
- Supply or ground to the unit missing
- Data wire chafed, open or shorted
Checks
- 1Measure supply and ground at the remote control connector and check its data wires.
- 2Test steps: see M7304.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Bobcat M7316Remote control not connected
The controller sees an open circuit on the remote control, so no current can flow through it and the remote control does not respond. The break is in the wire, the connector or the part itself.· Open circuitOpen circuitCheck soonCauses
- Pin backed out of the connector or plug not latched at the remote receiver connector
- Wire broken inside its insulation near a bend or clamp
- The receiver or key fob link burnt open or its internal lead broken
Checks
- 1Check that the remote control connector at the remote receiver connector is fully seated and its lock tab engaged.
- 2Measure the resistance of the receiver or key fob link with the plug off; an infinite reading confirms an open.
- 3Check continuity of each wire from the remote control plug back to the controller connector, flexing the harness as you go.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Shared checks
Checks, in order
- 1Press each switch while watching its state on the service screen to find which one reads wrong.
- 2Unplug the switch connector and check for moisture and pushed-back pins.
- 3Measure the circuit across the switch with it pressed and released; it should change between open and closed.
- 4Inspect the cable where it flexes for broken conductors.
- 5For the remote control, re-pair the key fob or remote and check its battery and receiver connector.
Causes
- Switch contacts worn or stuck from dirt
- Switch connector loose or corroded
- Cable damaged where it moves with the joystick or armrest
- Remote receiver or key fob not paired or lost power
Most common here: lost message (6 of 25)
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
When to stop
You'll notice: A switch does nothing or acts as if pressed, and the function it controls cannot be selected.
Lower attachments to the ground and relieve hydraulic pressure before loosening any fitting. Never feel for a leak with your hand - oil under pressure can inject through skin.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
- Bobcat Service Code List (rev. 10-20, M-Series/R-Series loaders and M-Series excavators)
- Bobcat S205 Operation & Maintenance Manual, service codes list
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.
