Bobcat · Auxiliary hydraulics
Bobcat Front, offset and Aux 4 solenoids fault codes
The front auxiliary valve, the boom offset valve and the Aux 4 valve on angle-blade machines each use a base solenoid for one direction and a rod solenoid for the other. A code names the valve and solenoid and whether the circuit is shorted to ground or battery, open or drawing too much current.
Where this code shows
On touchscreen R-series machines, touch the screen and pick Service Codes from the menu.
What do these codes mean?
Bobcat codes 26-02 to H5832 are all about the front, offset and Aux 4 solenoids. The most common failure type is shorted low (8 of 34); none needs an immediate stop. Start with this check: command the function in each direction from the cab and note which direction fails; that names the base or rod solenoid.
How urgent are they?
None of the 34 codes here means stop now; all 34 can wait until the shift ends, but find the cause before the next one.
- Check soon34
What should I check first?
Command the function in each direction from the cab and note which direction fails; that names the base or rod solenoid.
Shared checks34 of 34
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
Bobcat 26-02Front base solenoid error on
The controller sees the valve solenoid switched on when it was commanded off, so the front auxiliary keeps moving. The driver, relay or wiring is holding it on.· OtherOtherCheck soonCauses
- Output wire shorted to a live supply
- Relay or driver stuck closed
- Controller output stage failed and cannot switch off
Checks
- 1Unplug the valve solenoid at the front valve connector on the boom with the key on; if the controller still reads it on, the fault is in the wiring or controller.
- 2Check the output wire for contact with a power wire along its run.
- 3Listen and feel for the solenoid coil energising while it should be off.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat 26-03Front base solenoid error off
The controller sees the valve solenoid off when it was commanded on, so the front auxiliary does not move in that direction. The circuit is open, shorted to ground or not being driven.· Shorted lowShorted lowCheck soonCauses
- Open or grounded output wire
- The solenoid coil failed open
- Blown fuse or missing supply to the circuit
Checks
- 1Check the fuse and supply to the valve solenoid circuit with the key on.
- 2Measure the resistance of the solenoid coil and look for an open or a short to its body.
- 3Command the function and measure voltage at the valve solenoid plug; none means a wiring or controller fault.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat 27-02Front rod solenoid error on
Front rod solenoid error on: same fault as 26-02 (the output reads on when it should be off), here on the front rod solenoid.· OtherOtherCheck soonCauses
- Output wire shorted to a live supply
- Relay or driver stuck closed
Checks
- 1Unplug the front rod solenoid with the key on and see whether the controller still reads it on.
- 2Test steps: see 26-02.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat 27-03Front rod solenoid error off
Front rod solenoid error off: same fault as 26-03 (the output reads off when it was commanded on), here on the front rod solenoid.· OtherOtherCheck soonCauses
- Open or grounded output wire
- The solenoid coil failed open
Checks
- 1Check the fuse and the supply voltage at the front rod solenoid plug with the output commanded.
- 2Test steps: see 26-03.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat H0705Aux 4 base short to battery
The controller reads the valve solenoid circuit tied to battery voltage when it should only be switched by the controller. It shuts the output off to protect its driver, so the front auxiliary does not move in that direction.· Shorted highShorted highCheck soonCauses
- Output wire rubbed through at the front valve connector on the boom and touching a live supply wire
- Water or corrosion in the plug bridging a pin to a power pin
- Controller output stage failed shorted to supply
Checks
- 1Unplug the valve solenoid at the front valve connector on the boom and check its output wire for voltage with the key on; any voltage with the load removed is a short to supply.
- 2Trace the wire back from the solenoid coil for chafing next to live supply wires and for melted insulation.
- 3Replace the solenoid coil only if the wire reads clean and the part itself reads shorted.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Bobcat H0706Aux 4 base short to ground
The controller reads the valve solenoid circuit pulled to ground, so it cannot drive the load. The output is shut off and the front auxiliary does not move in that direction until the short is cleared.· Shorted lowShorted lowCheck soonCauses
- Wire chafed against the frame or a bracket at the front valve connector on the boom
- The solenoid coil shorted to its housing
- Water in the connector or a pin touching the shell
Checks
- 1With the plug off, test the valve solenoid output wire to chassis ground; a reading near zero shows a harness short.
- 2Measure from each pin of the solenoid coil to its body; any continuity means the part itself is shorted.
- 3Look for harness sections crushed under clamps or cut by sharp edges at the front valve connector on the boom.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat H0707Aux 4 base open circuit
The controller sees an open circuit on the valve solenoid, so no current can flow through it and the front auxiliary does not move in that direction. The break is in the wire, the connector or the part itself.· Open circuitOpen circuitCheck soonCauses
- Pin backed out of the connector or plug not latched at the front valve connector on the boom
- Wire broken inside its insulation near a bend or clamp
- The solenoid coil burnt open or its internal lead broken
Checks
- 1Check that the valve solenoid connector at the front valve connector on the boom is fully seated and its lock tab engaged.
- 2Measure the resistance of the solenoid coil with the plug off; an infinite reading confirms an open.
- 3Check continuity of each wire from the valve solenoid plug back to the controller connector, flexing the harness as you go.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat H0732Aux 4 base overcurrent
The controller measured too much current on the valve solenoid output and switched it off to protect its driver, so the front auxiliary does not move in that direction until the overload is cleared.· Real conditionReal conditionCheck soonCauses
- Coil shorted between turns so it draws too much current
- Wiring partly shorted to ground at the front valve connector on the boom
- Wrong or damaged part fitted that loads the output
Checks
- 1Measure the resistance of the solenoid coil with the plug off and compare it with a matching part on the same machine.
- 2Check the valve solenoid wire for a partial short to ground that only shows when the machine is hot or vibrating.
- 3Replace the part and clear the code; if it returns at once, suspect the controller output.
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Bobcat H0805Aux 4 rod short to battery
Aux 4 rod short to battery: same fault as H0705 (the circuit reads tied to battery voltage), here on the aux 4 rod.· Shorted highShorted highCheck soonCauses
- Output wire rubbed through
- Water or corrosion in the plug bridging a pin to a power pin
Checks
- 1Unplug the aux 4 rod and look for voltage on its output wire with the key on.
- 2Test steps: see H0705.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Bobcat H0806Aux 4 rod short to ground
Aux 4 rod short to ground: same fault as H0706 (the circuit reads pulled to ground), here on the aux 4 rod.· Shorted lowShorted lowCheck soonCauses
- Wire chafed against the frame or a bracket
- The solenoid coil shorted to its housing
Checks
- 1Test the aux 4 rod output wire to chassis ground with the plug off.
- 2Test steps: see H0706.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat H0807Aux 4 rod open circuit
Aux 4 rod open circuit: same fault as H0707 (the circuit is open), here on the aux 4 rod.· Open circuitOpen circuitCheck soonCauses
- Pin backed out of the connector or plug not latched
- Wire broken inside its insulation
Checks
- 1Check the aux 4 rod connector is seated, then measure across the part for an open.
- 2Test steps: see H0707.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat H0832Aux 4 rod overcurrent
Aux 4 rod overcurrent: same fault as H0732 (the circuit draws more current than the driver allows), here on the aux 4 rod.· OtherOtherCheck soonCauses
- Coil shorted between turns so it draws too much current
- Wiring partly shorted to ground
Checks
- 1Measure the resistance of the aux 4 rod and compare it with a matching part.
- 2Test steps: see H0732.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat H2605Front base solenoid short to battery
Front base solenoid short to battery: same fault as H0705 (the circuit reads tied to battery voltage), here on the front base solenoid.· Shorted highShorted highCheck soonCauses
- Output wire rubbed through
- Water or corrosion in the plug bridging a pin to a power pin
Checks
- 1Unplug the front base solenoid and look for voltage on its output wire with the key on.
- 2Test steps: see H0705.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Bobcat H2606Front base solenoid short to ground
Front base solenoid short to ground: same fault as H0706 (the circuit reads pulled to ground), here on the front base solenoid.· Shorted lowShorted lowCheck soonCauses
- Wire chafed against the frame or a bracket
- The solenoid coil shorted to its housing
Checks
- 1Test the front base solenoid output wire to chassis ground with the plug off.
- 2Test steps: see H0706.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat H2607Front base solenoid open circuit
Front base solenoid open circuit: same fault as H0707 (the circuit is open), here on the front base solenoid.· Open circuitOpen circuitCheck soonCauses
- Pin backed out of the connector or plug not latched
- Wire broken inside its insulation
Checks
- 1Check the front base solenoid connector is seated, then measure across the part for an open.
- 2Test steps: see H0707.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat H2632Front base solenoid overcurrent
Front base solenoid overcurrent: same fault as H0732 (the circuit draws more current than the driver allows), here on the front base solenoid.· OtherOtherCheck soonCauses
- Coil shorted between turns so it draws too much current
- Wiring partly shorted to ground
Checks
- 1Measure the resistance of the front base solenoid and compare it with a matching part.
- 2Test steps: see H0732.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat H2705Front rod solenoid short to battery
Front rod solenoid short to battery: same fault as H0705 (the circuit reads tied to battery voltage), here on the front rod solenoid.· Shorted highShorted highCheck soonCauses
- Output wire rubbed through
- Water or corrosion in the plug bridging a pin to a power pin
Checks
- 1Unplug the front rod solenoid and look for voltage on its output wire with the key on.
- 2Test steps: see H0705.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Bobcat H2706Front rod solenoid short to ground
Front rod solenoid short to ground: same fault as H0706 (the circuit reads pulled to ground), here on the front rod solenoid.· Shorted lowShorted lowCheck soonCauses
- Wire chafed against the frame or a bracket
- The solenoid coil shorted to its housing
Checks
- 1Test the front rod solenoid output wire to chassis ground with the plug off.
- 2Test steps: see H0706.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat H2707Front rod solenoid open circuit
Front rod solenoid open circuit: same fault as H0707 (the circuit is open), here on the front rod solenoid.· Open circuitOpen circuitCheck soonCauses
- Pin backed out of the connector or plug not latched
- Wire broken inside its insulation
Checks
- 1Check the front rod solenoid connector is seated, then measure across the part for an open.
- 2Test steps: see H0707.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat H2732Front rod solenoid overcurrent
Front rod solenoid overcurrent: same fault as H0732 (the circuit draws more current than the driver allows), here on the front rod solenoid.· OtherOtherCheck soonCauses
- Coil shorted between turns so it draws too much current
- Wiring partly shorted to ground
Checks
- 1Measure the resistance of the front rod solenoid and compare it with a matching part.
- 2Test steps: see H0732.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat M5205Offset base solenoid short to battery
Offset base solenoid short to battery: same fault as H0705 (the circuit reads tied to battery voltage), here on the offset base solenoid.· Shorted highShorted highCheck soonCauses
- Output wire rubbed through
- Water or corrosion in the plug bridging a pin to a power pin
Checks
- 1Unplug the offset base solenoid and look for voltage on its output wire with the key on.
- 2Test steps: see H0705.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Bobcat M5206Offset base solenoid short to ground
Offset base solenoid short to ground: same fault as H0706 (the circuit reads pulled to ground), here on the offset base solenoid.· Shorted lowShorted lowCheck soonCauses
- Wire chafed against the frame or a bracket
- The solenoid coil shorted to its housing
Checks
- 1Test the offset base solenoid output wire to chassis ground with the plug off.
- 2Test steps: see H0706.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat M5207Offset base solenoid open circuit
Offset base solenoid open circuit: same fault as H0707 (the circuit is open), here on the offset base solenoid.· Open circuitOpen circuitCheck soonCauses
- Pin backed out of the connector or plug not latched
- Wire broken inside its insulation
Checks
- 1Check the offset base solenoid connector is seated, then measure across the part for an open.
- 2Test steps: see H0707.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat M5232Offset base solenoid overcurrent
Offset base solenoid overcurrent: same fault as H0732 (the circuit draws more current than the driver allows), here on the offset base solenoid.· OtherOtherCheck soonCauses
- Coil shorted between turns so it draws too much current
- Wiring partly shorted to ground
Checks
- 1Measure the resistance of the offset base solenoid and compare it with a matching part.
- 2Test steps: see H0732.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat M5307Offset rod solenoid open circuit
Offset rod solenoid open circuit: same fault as H0707 (the circuit is open), here on the offset rod solenoid.· Open circuitOpen circuitCheck soonCauses
- Pin backed out of the connector or plug not latched
- Wire broken inside its insulation
Checks
- 1Check the offset rod solenoid connector is seated, then measure across the part for an open.
- 2Test steps: see H0707.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat M5332Offset rod solenoid overcurrent
Offset rod solenoid overcurrent: same fault as H0732 (the circuit draws more current than the driver allows), here on the offset rod solenoid.· OtherOtherCheck soonCauses
- Coil shorted between turns so it draws too much current
- Wiring partly shorted to ground
Checks
- 1Measure the resistance of the offset rod solenoid and compare it with a matching part.
- 2Test steps: see H0732.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat H5705Angle blade aux 4 base short to battery
Angle blade aux 4 base short to battery: same fault as H0705 (the circuit reads tied to battery voltage), here on the angle blade aux 4 base.· Shorted highShorted highCheck soonCauses
- Output wire rubbed through
- Water or corrosion in the plug bridging a pin to a power pin
Checks
- 1Unplug the angle blade aux 4 base and look for voltage on its output wire with the key on.
- 2Test steps: see H0705.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Bobcat H5706Angle blade aux 4 base short to ground
Angle blade aux 4 base short to ground: same fault as H0706 (the circuit reads pulled to ground), here on the angle blade aux 4 base.· Shorted lowShorted lowCheck soonCauses
- Wire chafed against the frame or a bracket
- The solenoid coil shorted to its housing
Checks
- 1Test the angle blade aux 4 base output wire to chassis ground with the plug off.
- 2Test steps: see H0706.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat H5707Angle blade aux 4 base open circuit
Angle blade aux 4 base open circuit: same fault as H0707 (the circuit is open), here on the angle blade aux 4 base.· Open circuitOpen circuitCheck soonCauses
- Pin backed out of the connector or plug not latched
- Wire broken inside its insulation
Checks
- 1Check the angle blade aux 4 base connector is seated, then measure across the part for an open.
- 2Test steps: see H0707.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat H5732Angle blade aux 4 base overcurrent
Angle blade aux 4 base overcurrent: same fault as H0732 (the circuit draws more current than the driver allows), here on the angle blade aux 4 base.· OtherOtherCheck soonCauses
- Coil shorted between turns so it draws too much current
- Wiring partly shorted to ground
Checks
- 1Measure the resistance of the angle blade aux 4 base and compare it with a matching part.
- 2Test steps: see H0732.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat H5805Angle blade aux 4 rod short to battery
Angle blade aux 4 rod short to battery: same fault as H0705 (the circuit reads tied to battery voltage), here on the angle blade aux 4 rod.· Shorted highShorted highCheck soonCauses
- Output wire rubbed through
- Water or corrosion in the plug bridging a pin to a power pin
Checks
- 1Unplug the angle blade aux 4 rod and look for voltage on its output wire with the key on.
- 2Test steps: see H0705.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Bobcat H5806Angle blade aux 4 rod short to ground
Angle blade aux 4 rod short to ground: same fault as H0706 (the circuit reads pulled to ground), here on the angle blade aux 4 rod.· Shorted lowShorted lowCheck soonCauses
- Wire chafed against the frame or a bracket
- The solenoid coil shorted to its housing
Checks
- 1Test the angle blade aux 4 rod output wire to chassis ground with the plug off.
- 2Test steps: see H0706.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat H5807Angle blade aux 4 rod open circuit
Angle blade aux 4 rod open circuit: same fault as H0707 (the circuit is open), here on the angle blade aux 4 rod.· Open circuitOpen circuitCheck soonCauses
- Pin backed out of the connector or plug not latched
- Wire broken inside its insulation
Checks
- 1Check the angle blade aux 4 rod connector is seated, then measure across the part for an open.
- 2Test steps: see H0707.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Bobcat H5832Angle blade aux 4 rod overcurrent
Angle blade aux 4 rod overcurrent: same fault as H0732 (the circuit draws more current than the driver allows), here on the angle blade aux 4 rod.· OtherOtherCheck soonCauses
- Coil shorted between turns so it draws too much current
- Wiring partly shorted to ground
Checks
- 1Measure the resistance of the angle blade aux 4 rod and compare it with a matching part.
- 2Test steps: see H0732.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Shared checks
Checks, in order
- 1Command the function in each direction from the cab and note which direction fails; that names the base or rod solenoid.
- 2Measure the coil resistance of the named solenoid with the plug off and compare it with the other solenoid on the same valve.
- 3Check the valve connector for water and pushed-back pins before testing wiring.
- 4Measure supply voltage at the plug while the function is commanded; none points to the harness or controller output.
- 5Inspect the harness along the boom and at the offset pivot for fatigue breaks and rubbed insulation.
Causes
- Solenoid coil shorted between turns or burnt open
- Harness chafed along the boom or at the offset hinge
- Connector corroded where it is exposed to wash water
- Spool sticking from contaminated hydraulic oil
Most common here: shorted low (8 of 34)
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
When to stop
You'll notice: The front auxiliary, boom offset or angle blade function does not move in one direction, or does not move at all.
Lower attachments to the ground and relieve hydraulic pressure before loosening any fitting. Never feel for a leak with your hand - oil under pressure can inject through skin.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
- Bobcat Service Code List (rev. 10-20, M-Series/R-Series loaders and M-Series excavators)
- Bobcat S205 Operation & Maintenance Manual, service codes list
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.