EF Logo

Bobcat · Hydraulics

Bobcat Bob-Tach controls and boom, arm and bucket angle sensors fault codes

The Bob-Tach controls lock and release the attachment, while angle sensors on the boom, arm, bucket, frame and Bob-Tach report the geometry to the controller for limits and automatic functions. Codes are out of range high or low, no signal, or a calibration fault.

FaultCheckVSE007-03Bobcat · Bob-Tach controls and boom, arm and bucket angle sensors
Code shows hereFAULTVSE007-03

Where this code shows

On touchscreen R-series machines, touch the screen and pick Service Codes from the menu.

What do these codes mean?

Bobcat codes VSE007-03 to H3702 are all about the bob-Tach controls and boom, arm and bucket angle sensors. The most common failure type is lost message (7 of 23); none needs an immediate stop. Start with this check: move the boom, arm and bucket and watch the angle readings change smoothly on the service screen.

How urgent are they?

None of the 23 codes here means stop now; all 23 can wait until the shift ends, but find the cause before the next one.

  • Check soon23

What should I check first?

Move the boom, arm and bucket and watch the angle readings change smoothly on the service screen.

Shared checks

23 of 23

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Bobcat VSE007-03Angle sensor (a), voltage above normal

    The signal voltage from the angle sensor (a) is above the normal range.· Shorted high
    Check soon

    Causes

    • Signal wire shorted to a supply wire
    • Open sensor ground
    • Sensor failed

    Checks

    1. 1Check the sensor ground at the angle sensor (a) plug and its continuity back to the controller
    2. 2Test the signal wire for voltage with the plug off
    3. 3Swap in a known good sensor to see if the reading moves back into range
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat VSE007-04Angle sensor (a), voltage below normal

    The signal voltage from the angle sensor (a) is below the normal range.· Shorted low
    Check soon

    Causes

    • Sensor wire shorted to ground
    • Open sensor supply or ground
    • Sensor failed

    Checks

    1. 1Check the 5 V supply and ground at the angle sensor (a) plug with the key on
    2. 2Test the signal wire to ground with the plug off
    3. 3Compare the reading with a known good sensor or the same input on a matching machine
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat VSE008-03Angle sensor (b), voltage above normal

    The signal voltage from the angle sensor (b) is above the normal range.· Shorted high
    Check soon

    Causes

    • Signal wire shorted to a supply wire
    • Open sensor ground
    • Sensor failed

    Checks

    1. 1Check the sensor ground at the angle sensor (b) plug and its continuity back to the controller
    2. 2Test the signal wire for voltage with the plug off
    3. 3Swap in a known good sensor to see if the reading moves back into range
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat VSE008-04Angle sensor (b), voltage below normal

    The signal voltage from the angle sensor (b) is below the normal range.· Shorted low
    Check soon

    Causes

    • Sensor wire shorted to ground
    • Open sensor supply or ground
    • Sensor failed

    Checks

    1. 1Check the 5 V supply and ground at the angle sensor (b) plug with the key on
    2. 2Test the signal wire to ground with the plug off
    3. 3Compare the reading with a known good sensor or the same input on a matching machine
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat C103C-11Bob-Tach engage short to ground

    The controller reads the bob-tach engage circuit pulled to ground, so it cannot drive the load.· Shorted low
    Check soon

    Causes

    • Wire chafed against the frame or a bracket
    • Coil or element shorted to its housing
    • Water in the connector or a pin touching the shell

    Checks

    1. 1With the plug off, test the output wire to chassis ground; a reading near zero shows a harness short
    2. 2Measure from each coil pin to the body of the bob-tach engage; any continuity means the part is shorted
    3. 3Look for harness sections crushed under clamps or cut by sharp edges near the bob-tach engage
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat C103D-11Bob-Tach disengage short to ground

    The controller reads the bob-tach disengage circuit pulled to ground, so it cannot drive the load.· Shorted low
    Check soon

    Causes

    • Wire chafed against the frame or a bracket
    • Coil or element shorted to its housing
    • Water in the connector or a pin touching the shell

    Checks

    1. 1With the plug off, test the output wire to chassis ground; a reading near zero shows a harness short
    2. 2Measure from each coil pin to the body of the bob-tach disengage; any continuity means the part is shorted
    3. 3Look for harness sections crushed under clamps or cut by sharp edges near the bob-tach disengage
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat C103C-12Bob-Tach engage short to battery

    The controller reads the bob-tach engage circuit as tied to battery voltage when it should be switched by the controller.· Shorted high
    Check soon

    Causes

    • Output wire rubbed through and touching a live supply wire
    • Water or corrosion in the plug bridging a pin to a power pin
    • Controller output stage failed shorted to supply

    Checks

    1. 1Unplug the bob-tach engage and check the output wire for voltage with the key on; any voltage with the load removed is a short to supply
    2. 2Trace the wire along the harness for chafing next to live supply wires and for melted insulation
    3. 3Replace the bob-tach engage only if the wire reads clean and the coil or element itself reads shorted
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat C103D-12Bob-Tach disengage short to battery

    The controller reads the bob-tach disengage circuit as tied to battery voltage when it should be switched by the controller.· Shorted high
    Check soon

    Causes

    • Output wire rubbed through and touching a live supply wire
    • Water or corrosion in the plug bridging a pin to a power pin
    • Controller output stage failed shorted to supply

    Checks

    1. 1Unplug the bob-tach disengage and check the output wire for voltage with the key on; any voltage with the load removed is a short to supply
    2. 2Trace the wire along the harness for chafing next to live supply wires and for melted insulation
    3. 3Replace the bob-tach disengage only if the wire reads clean and the coil or element itself reads shorted
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat C103C-13Bob-Tach engage open circuit

    The controller sees an open circuit on the bob-tach engage, meaning no current can flow through it.· Open circuit
    Check soon

    Causes

    • Pin backed out of the connector or plug not latched
    • Wire broken inside its insulation near a bend or clamp
    • Coil or element burnt open

    Checks

    1. 1Check the connector at the bob-tach engage is fully seated and its lock tab engaged
    2. 2Measure the resistance across the part with the plug off; infinite resistance confirms an open
    3. 3Check continuity of each wire from the plug back to the controller connector
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Bobcat C103D-13Bob-Tach disengage open circuit

    The controller sees an open circuit on the bob-tach disengage, meaning no current can flow through it.· Open circuit
    Check soon

    Causes

    • Pin backed out of the connector or plug not latched
    • Wire broken inside its insulation near a bend or clamp
    • Coil or element burnt open

    Checks

    1. 1Check the connector at the bob-tach disengage is fully seated and its lock tab engaged
    2. 2Measure the resistance across the part with the plug off; infinite resistance confirms an open
    3. 3Check continuity of each wire from the plug back to the controller connector
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Bobcat H0104Boom angle sensor no communication

    The controller cannot talk to the boom angle sensor.· Lost message
    Check soon

    Causes

    • Loose or corroded CAN connector
    • CAN wire broken or shorted
    • Device without power or damaged

    Checks

    1. 1Check the supply and ground at the boom angle sensor plug
    2. 2Check the CAN wires for continuity and for shorts to each other
    3. 3Reseat the connectors and cycle the key to see if communication returns
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Bobcat H0204Arm angle sensor no communication

    The controller cannot talk to the arm angle sensor.· Lost message
    Check soon

    Causes

    • Loose or corroded CAN connector
    • CAN wire broken or shorted
    • Device without power or damaged

    Checks

    1. 1Check the supply and ground at the arm angle sensor plug
    2. 2Check the CAN wires for continuity and for shorts to each other
    3. 3Reseat the connectors and cycle the key to see if communication returns
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Bobcat H0304Bucket angle sensor no communication

    The controller cannot talk to the bucket angle sensor.· Lost message
    Check soon

    Causes

    • Loose or corroded CAN connector
    • CAN wire broken or shorted
    • Device without power or damaged

    Checks

    1. 1Check the supply and ground at the bucket angle sensor plug
    2. 2Check the CAN wires for continuity and for shorts to each other
    3. 3Reseat the connectors and cycle the key to see if communication returns
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Bobcat H0405Angle sensor supply short to battery

    The controller reads the angle sensor supply circuit as tied to battery voltage when it should be switched by the controller.· Shorted high
    Check soon

    Causes

    • Output wire rubbed through and touching a live supply wire
    • Water or corrosion in the plug bridging a pin to a power pin
    • Controller output stage failed shorted to supply

    Checks

    1. 1Unplug the angle sensor supply and check the output wire for voltage with the key on; any voltage with the load removed is a short to supply
    2. 2Trace the wire along the harness for chafing next to live supply wires and for melted insulation
    3. 3Replace the angle sensor supply only if the wire reads clean and the coil or element itself reads shorted
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat H0406Angle sensor supply short to ground

    The controller reads the angle sensor supply circuit pulled to ground, so it cannot drive the load.· Shorted low
    Check soon

    Causes

    • Wire chafed against the frame or a bracket
    • Coil or element shorted to its housing
    • Water in the connector or a pin touching the shell

    Checks

    1. 1With the plug off, test the output wire to chassis ground; a reading near zero shows a harness short
    2. 2Measure from each coil pin to the body of the angle sensor supply; any continuity means the part is shorted
    3. 3Look for harness sections crushed under clamps or cut by sharp edges near the angle sensor supply
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat H0407Angle sensor supply open circuit

    The controller sees an open circuit on the angle sensor supply, meaning no current can flow through it.· Open circuit
    Check soon

    Causes

    • Pin backed out of the connector or plug not latched
    • Wire broken inside its insulation near a bend or clamp
    • Coil or element burnt open

    Checks

    1. 1Check the connector at the angle sensor supply is fully seated and its lock tab engaged
    2. 2Measure the resistance across the part with the plug off; infinite resistance confirms an open
    3. 3Check continuity of each wire from the plug back to the controller connector
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Bobcat B1100-9EBob-Tach engage button stuck on

    The controller reads the bob-tach engage button as stuck.· Other
    Check soon

    Causes

    • Sensor or mechanism seized
    • Debris in the part
    • Signal wire fault

    Checks

    1. 1Check the bob-tach engage button moves freely by hand with the key off
    2. 2Check its signal on the display while moving it
    3. 3Replace the part if the reading never changes
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat B1101-9EBob-Tach disengage button stuck on

    The controller reads the bob-tach disengage button as stuck.· Other
    Check soon

    Causes

    • Sensor or mechanism seized
    • Debris in the part
    • Signal wire fault

    Checks

    1. 1Check the bob-tach disengage button moves freely by hand with the key off
    2. 2Check its signal on the display while moving it
    3. 3Replace the part if the reading never changes
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat U1110-08Bob-Tach angle sensor no communication

    The controller cannot talk to the bob-tach angle sensor.· Lost message
    Check soon

    Causes

    • Loose or corroded CAN connector
    • CAN wire broken or shorted
    • Device without power or damaged

    Checks

    1. 1Check the supply and ground at the bob-tach angle sensor plug
    2. 2Check the CAN wires for continuity and for shorts to each other
    3. 3Reseat the connectors and cycle the key to see if communication returns
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Bobcat U1111-08Bucket angle sensor no communication

    The controller cannot talk to the bucket angle sensor.· Lost message
    Check soon

    Causes

    • Loose or corroded CAN connector
    • CAN wire broken or shorted
    • Device without power or damaged

    Checks

    1. 1Check the supply and ground at the bucket angle sensor plug
    2. 2Check the CAN wires for continuity and for shorts to each other
    3. 3Reseat the connectors and cycle the key to see if communication returns
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Bobcat U1112-08Lift arm angle no communication

    The controller cannot talk to the lift arm angle.· Lost message
    Check soon

    Causes

    • Loose or corroded CAN connector
    • CAN wire broken or shorted
    • Device without power or damaged

    Checks

    1. 1Check the supply and ground at the lift arm angle plug
    2. 2Check the CAN wires for continuity and for shorts to each other
    3. 3Reseat the connectors and cycle the key to see if communication returns
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Bobcat U1113-08Frame angle sensor no communication

    The controller cannot talk to the frame angle sensor.· Lost message
    Check soon

    Causes

    • Loose or corroded CAN connector
    • CAN wire broken or shorted
    • Device without power or damaged

    Checks

    1. 1Check the supply and ground at the frame angle sensor plug
    2. 2Check the CAN wires for continuity and for shorts to each other
    3. 3Reseat the connectors and cycle the key to see if communication returns
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Bobcat H3702Power Bob-Tach up solenoid error on

    The controller sees the power bob-tach up solenoid switched on when it was commanded off.· Shorted high
    Check soon

    Causes

    • Output wire shorted to a live supply
    • Relay or driver stuck on
    • Controller output stage failed

    Checks

    1. 1Unplug the power bob-tach up solenoid with the key on; if the controller still reads it on, the fault is in the wiring or controller
    2. 2Check the output wire for contact with a power wire along its run
    3. 3Listen and feel for the part energising while it should be off
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

Shared checks

Checks, in order

  1. 1Move the boom, arm and bucket and watch the angle readings change smoothly on the service screen.
  2. 2Check the sensor linkage and mounting bolts for looseness.
  3. 3Check the sensor connector and its supply and ground.
  4. 4Run the angle calibration after replacing a sensor.
  5. 5Operate the Bob-Tach switch and watch the output state on screen.

Causes

  • Angle sensor linkage loose or damaged
  • Sensor connector corroded
  • Bob-Tach valve or switch failed
  • Calibration lost after a sensor change

Most common here: lost message (7 of 23)

Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

When to stop

You'll notice: Automatic functions or limits stop working, the bucket angle display is wrong, or the Bob-Tach cannot be released.

Lower attachments to the ground and relieve hydraulic pressure before loosening any fitting. Never feel for a leak with your hand - oil under pressure can inject through skin.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.