EF Logo

Bobcat · Electrical

Bobcat System, battery, alternator and controller voltage fault codes

These codes report the voltage the controllers see at their own supply pins and the alternator output: low or high system voltage, battery voltage at a named controller and alternator faults. They share one supply, so one wiring or charging fault often sets several codes together.

FaultCheck03-09Bobcat · System, battery, alternator and controller voltage
Code shows hereFAULT03-09

Where this code shows

On touchscreen R-series machines, touch the screen and pick Service Codes from the menu.

What do these codes mean?

Bobcat codes LOWVLTG to D7571 are all about the system, battery, alternator and controller voltage. The most common failure type is shorted high (12 of 35); 5 need an immediate stop. Start with this check: measure battery voltage with the engine off and again running; running voltage should be clearly above resting voltage, in the normal 12 to 14 V range.

How urgent are they?

5 of 35 codes here mean stop now; the other 30 can wait until the shift ends, but find the cause before the next one.

  • Stop now5
  • Check soon30

What should I check first?

Measure battery voltage with the engine off and again running; running voltage should be clearly above resting voltage, in the normal 12 to 14 V range.

Shared checks

35 of 35

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Bobcat LOWVLTGLow battery voltage

    The controller logged the message "Low battery voltage".· Other
    Check soon

    Causes

    • Condition the message names is active
    • Wiring or connector problem on the related part
    • Software or programming mismatch

    Checks

    1. 1Read the message in context with any other active code
    2. 2Check the related part and its plug for damage
    3. 3Clear the code and see whether it returns
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat VRLOWVLTGVery low battery voltage

    The controller logged the message "Very low battery voltage".· Other
    Check soon

    Causes

    • Condition the message names is active
    • Wiring or connector problem on the related part
    • Software or programming mismatch

    Checks

    1. 1Read the message in context with any other active code
    2. 2Check the related part and its plug for damage
    3. 3Clear the code and see whether it returns
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat VAL001-03Alternator potential, voltage above normal

    The signal voltage from the alternator potential is above the normal range.· Shorted high
    Check soon

    Causes

    • Signal wire shorted to a supply wire
    • Open sensor ground
    • Sensor failed

    Checks

    1. 1Check the sensor ground at the alternator potential plug and its continuity back to the controller
    2. 2Test the signal wire for voltage with the plug off
    3. 3Swap in a known good sensor to see if the reading moves back into range
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat VAL001-04Alternator potential, voltage below normal

    The signal voltage from the alternator potential is below the normal range.· Shorted low
    Check soon

    Causes

    • Sensor wire shorted to ground
    • Open sensor supply or ground
    • Sensor failed

    Checks

    1. 1Check the 5 V supply and ground at the alternator potential plug with the key on
    2. 2Test the signal wire to ground with the plug off
    3. 3Compare the reading with a known good sensor or the same input on a matching machine
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat 03-09Battery voltage low

    System voltage is below normal, typically a charging problem.· Shorted low
    Check soon

    Causes

    • Corroded or loose battery cable ends
    • Alternator not charging
    • Tired battery that no longer holds a charge
    • Alternator drive belt slipping or glazed

    Checks

    1. 1Check the main battery cables and the engine-to-frame ground for green crust or loose clamps and clean them back to bare metal
    2. 2With the engine at high idle, measure across the battery posts; a healthy charging system shows clearly more than the resting battery voltage
    3. 3Back-probe the alternator output stud and the charge wire at the alternator plug with the engine running to see whether voltage leaves the alternator
    4. 4Watch the voltage while switching on lights and working the hydraulics; a reading that sags with each load points at a weak alternator
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat 03-10Battery voltage high

    System voltage is above normal.· Shorted high
    Check soon

    Causes

    • Loose or corroded battery post or ground
    • Wrong battery type or a jump start left connected wrongly
    • Charge wire from the alternator picking up extra supply

    Checks

    1. 1Ask whether the machine was jump started recently and check the polarity and cable ends used
    2. 2Measure the voltage across the battery at high idle; a steady reading well above a normal charging level means the regulator is stuck high
    3. 3Compare the voltage at the alternator stud to the voltage at the battery; a big gap points at a cable or fuse resistance
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat 03-11Battery voltage extremely high

    Voltage is far above normal and can damage the controller.· Shorted high
    Stop now

    Causes

    • Battery cable pulled off while running
    • Charge wire shorted to a switched supply
    • Two batteries or a booster pack connected in series by mistake

    Checks

    1. 1Stop the engine and measure the battery with the key off first; if the resting voltage is normal the spike is coming from the alternator side
    2. 2Look for burnt or discoloured lamps, relays or sensor plugs that were hit by the surge, and replace any that are damaged
    3. 3Disconnect the alternator output wire and run briefly; if the voltage drops to normal the alternator regulator is the failed part
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat 03-14Battery voltage extremely low

    Voltage is very low and the controller may shut down.· Shorted low
    Stop now

    Causes

    • Main battery cable or ground broken inside the insulation
    • Starter drawing the battery down
    • Flat or sulphated battery

    Checks

    1. 1Inspect the starter for a stuck solenoid or a dragging motor that is pulling the system down every time it cranks
    2. 2Measure battery voltage at rest and while cranking; if it drops almost to nothing the battery or a cable is not carrying current
    3. 3Charge the battery and retest; if it will not hold the charge or fails a load test, replace it
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat 03-22Battery voltage out of range low

    Controller supply voltage is below the valid window.· Other
    Check soon

    Causes

    • Corroded fuse holder or relay socket in the feed
    • Loose ignition feed at the controller plug
    • Weak battery that sags when loads switch on

    Checks

    1. 1Inspect the relay that feeds the controller for pitted contacts, and swap it with a known good one if it clicks weakly
    2. 2With the key on, measure the supply pin at the controller plug against the battery voltage; a difference means loss in the feed wire or a fuse holder
    3. 3Check the controller ground pins against the battery negative; resistance in the ground behaves like low supply voltage
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat 32-66Battery voltage out of range

    The battery voltage signal is outside the range the controller accepts.· Other
    Check soon

    Causes

    • Sensor or its wiring fault
    • Loose connector
    • Supply or ground problem on the circuit

    Checks

    1. 1Check the connector at the battery voltage for moisture and bent pins
    2. 2Check supply and ground at the plug with the key on using a meter
    3. 3Compare the live reading with a separate gauge
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat U109C-A2Lights controller voltage low

    The lights controller voltage reads below its warning level.· Shorted low
    Check soon

    Causes

    • Real low value from leakage or restriction
    • Worn pump or low fluid
    • Sensor reading low

    Checks

    1. 1Verify the real value with a separate gauge before replacing anything
    2. 2Check fluid levels and filters in the system the lights controller voltage belongs to
    3. 3Check the sensor wiring if the real value turns out normal
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat U109C-A3Lights controller voltage high

    The lights controller voltage reads above its warning level.· Shorted high
    Check soon

    Causes

    • Real overload or overheat on the system
    • Restricted flow or poor cooling
    • Sensor reading high

    Checks

    1. 1Verify the real value with a separate gauge or probe before replacing anything
    2. 2Check cooling, filters and flow in the system the lights controller voltage belongs to
    3. 3Check the sensor wiring if the real value turns out normal
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat M0309System voltage too low

    System voltage has dropped below normal while the engine is running.· Shorted low
    Check soon

    Causes

    • Poor ground strap between engine and frame
    • Tired battery that no longer holds a charge
    • Alternator not charging
    • Corroded or loose battery cable ends

    Checks

    1. 1Shut down and measure resting voltage after the machine has sat; a battery that falls fast under cranking is the cause, not the alternator
    2. 2Look at the alternator belt for glazing, cracks or a loose tension; a slipping belt squeals when the hydraulics load the engine
    3. 3Check the main fuse or fusible link in the alternator charge line; a blown link leaves the battery to carry the whole load
    4. 4Run a load test on the battery if the charging side checks out; a cell that has collapsed will keep triggering this code
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat M0310System voltage too high

    The electrical system is seeing more than normal charging voltage, which can damage the controller and lamps.· Shorted high
    Check soon

    Causes

    • Battery with a dead cell causing the regulator to overcharge
    • Loose or corroded battery post or ground
    • Wrong battery type or a jump start left connected wrongly

    Checks

    1. 1Inspect the alternator plug for pushed-back pins, corrosion or a loose sense wire that keeps the regulator reading low
    2. 2Check both battery posts and the engine ground; a poor connection can make the regulator sense low and push the output up
    3. 3Check the battery for a hot, swollen case or a smell of acid; a damaged cell makes the alternator overwork
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat M0311System voltage extremely high

    Voltage has gone far above the safe level.· Shorted high
    Stop now

    Causes

    • Open connection at the battery that lets the alternator spike
    • Two batteries or a booster pack connected in series by mistake
    • Battery cable pulled off while running

    Checks

    1. 1Inspect the harness near the alternator for a charge wire that touched another live wire
    2. 2Inspect the battery terminals for a loose or broken clamp that could let a voltage surge reach the controller
    3. 3Check whether a booster pack, charger or second battery was left connected after a start
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat M0314System voltage extremely low

    System voltage is very low.· Other
    Stop now

    Causes

    • Main power relay or fuse failing under load
    • Alternator completely dead
    • Main battery cable or ground broken inside the insulation

    Checks

    1. 1Hold the key in start while checking voltage drop across each battery cable; a drop across a cable means a hidden break or crust
    2. 2Check that the alternator is spinning and putting out voltage as soon as the engine runs; no output means a dead alternator
    3. 3Check the main power fuse and relay for heat marks or a loose blade and push each back in firmly
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat W0321Battery voltage out of range high

    The battery voltage signal is above the valid range the controller accepts, so the reading is treated as a sensor or wiring problem rather than a real value.· Other
    Check soon

    Causes

    • Signal wire shorted to supply
    • Open sensor ground giving a floating high signal
    • Sensor failed high

    Checks

    1. 1Check the ground wire of the battery voltage for continuity
    2. 2Look at the live reading on the display and see if it sits at the top of its scale
    3. 3Test the signal wire for stray voltage with the plug off
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M0322System voltage out of range low

    The controller measured supply voltage below the allowed window, often during cranking or with a bad connection.· Other
    Check soon

    Causes

    • Corroded fuse holder or relay socket in the feed
    • Poor controller ground connection
    • Weak battery that sags when loads switch on
    • Chafed power wire with high resistance

    Checks

    1. 1Look for the power feed running through a worn connector or bulkhead plug along the harness that has heat marks
    2. 2Check the ignition-switched fuse and its holder for burnt contacts and spread blades
    3. 3Wiggle the controller harness plug while watching the supply reading and the display; a flicker shows a loose terminal
    4. 4After the repair, clear the code and cycle the key a few times while watching for return
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat W0322Battery voltage out of range low

    The battery voltage signal is below the valid range the controller accepts, so the reading is treated as a sensor or wiring problem rather than a real value.· Other
    Check soon

    Causes

    • Signal wire shorted to ground
    • Open signal wire or missing supply
    • Sensor failed low

    Checks

    1. 1Check the supply voltage at the battery voltage plug with the key on
    2. 2Look at the live reading on the display and see if it sits at the bottom of its scale
    3. 3Test the signal wire to ground with the plug off
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat U1092-A2Cab controller system voltage low

    The cab controller system voltage reads below its warning level.· Shorted low
    Check soon

    Causes

    • Real low value from leakage or restriction
    • Worn pump or low fluid
    • Sensor reading low

    Checks

    1. 1Verify the real value with a separate gauge before replacing anything
    2. 2Check fluid levels and filters in the system the cab controller system voltage belongs to
    3. 3Check the sensor wiring if the real value turns out normal
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat U1092-A3Cab controller system voltage high

    The cab controller system voltage reads above its warning level.· Shorted high
    Check soon

    Causes

    • Real overload or overheat on the system
    • Restricted flow or poor cooling
    • Sensor reading high

    Checks

    1. 1Verify the real value with a separate gauge or probe before replacing anything
    2. 2Check cooling, filters and flow in the system the cab controller system voltage belongs to
    3. 3Check the sensor wiring if the real value turns out normal
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat U1093-A2Battery voltage low

    The battery voltage reads below its warning level.· Shorted low
    Check soon

    Causes

    • Real low value from leakage or restriction
    • Worn pump or low fluid
    • Sensor reading low

    Checks

    1. 1Verify the real value with a separate gauge before replacing anything
    2. 2Check fluid levels and filters in the system the battery voltage belongs to
    3. 3Check the sensor wiring if the real value turns out normal
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat U1093-A3Battery voltage high

    The battery voltage reads above its warning level.· Shorted high
    Check soon

    Causes

    • Real overload or overheat on the system
    • Restricted flow or poor cooling
    • Sensor reading high

    Checks

    1. 1Verify the real value with a separate gauge or probe before replacing anything
    2. 2Check cooling, filters and flow in the system the battery voltage belongs to
    3. 3Check the sensor wiring if the real value turns out normal
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat U1097-A2Aux controller system voltage low

    The aux controller system voltage reads below its warning level.· Shorted low
    Check soon

    Causes

    • Real low value from leakage or restriction
    • Worn pump or low fluid
    • Sensor reading low

    Checks

    1. 1Verify the real value with a separate gauge before replacing anything
    2. 2Check fluid levels and filters in the system the aux controller system voltage belongs to
    3. 3Check the sensor wiring if the real value turns out normal
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat U1097-A3Aux controller system voltage high

    The aux controller system voltage reads above its warning level.· Shorted high
    Check soon

    Causes

    • Real overload or overheat on the system
    • Restricted flow or poor cooling
    • Sensor reading high

    Checks

    1. 1Verify the real value with a separate gauge or probe before replacing anything
    2. 2Check cooling, filters and flow in the system the aux controller system voltage belongs to
    3. 3Check the sensor wiring if the real value turns out normal
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat U1098-A2Rear auxiliary controller system voltage low

    The rear auxiliary controller system voltage reads below its warning level.· Shorted low
    Check soon

    Causes

    • Real low value from leakage or restriction
    • Worn pump or low fluid
    • Sensor reading low

    Checks

    1. 1Verify the real value with a separate gauge before replacing anything
    2. 2Check fluid levels and filters in the system the rear auxiliary controller system voltage belongs to
    3. 3Check the sensor wiring if the real value turns out normal
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat U1098-A3Rear auxiliary controller system voltage high

    The rear auxiliary controller system voltage reads above its warning level.· Shorted high
    Check soon

    Causes

    • Real overload or overheat on the system
    • Restricted flow or poor cooling
    • Sensor reading high

    Checks

    1. 1Verify the real value with a separate gauge or probe before replacing anything
    2. 2Check cooling, filters and flow in the system the rear auxiliary controller system voltage belongs to
    3. 3Check the sensor wiring if the real value turns out normal
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat C1182-A3Alternator voltage high

    The alternator voltage reads above its warning level.· Shorted high
    Check soon

    Causes

    • Real overload or overheat on the system
    • Restricted flow or poor cooling
    • Sensor reading high

    Checks

    1. 1Verify the real value with a separate gauge or probe before replacing anything
    2. 2Check cooling, filters and flow in the system the alternator voltage belongs to
    3. 3Check the sensor wiring if the real value turns out normal
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat C1190-00System voltage out of range low

    The system voltage signal is below the valid range the controller accepts, so the reading is treated as a sensor or wiring problem rather than a real value.· Other
    Check soon

    Causes

    • Signal wire shorted to ground
    • Open signal wire or missing supply
    • Sensor failed low

    Checks

    1. 1Check the supply voltage at the system voltage plug with the key on
    2. 2Look at the live reading on the display and see if it sits at the bottom of its scale
    3. 3Test the signal wire to ground with the plug off
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat C1195-00System voltage extremely low

    The system voltage is far below its normal level.· Other
    Stop now

    Causes

    • Loss of fluid or pressure
    • Pump or supply failure
    • Sensor reading extremely low

    Checks

    1. 1Stop the machine and check fluid levels first
    2. 2Verify the real value with a separate gauge
    3. 3Check the supply line and pump before suspecting the sensor
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat W3266ACS battery voltage out of range

    The acs battery voltage signal is outside the range the controller accepts.· Other
    Check soon

    Causes

    • Sensor or its wiring fault
    • Loose connector
    • Supply or ground problem on the circuit

    Checks

    1. 1Check the connector at the acs battery voltage for moisture and bent pins
    2. 2Check supply and ground at the plug with the key on using a meter
    3. 3Compare the live reading with a separate gauge
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M4109Alternator low

    The alternator reads below its warning level.· Shorted low
    Check soon

    Causes

    • Real low value from leakage or restriction
    • Worn pump or low fluid
    • Sensor reading low

    Checks

    1. 1Verify the real value with a separate gauge before replacing anything
    2. 2Check fluid levels and filters in the system the alternator belongs to
    3. 3Check the sensor wiring if the real value turns out normal
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat M4110Alternator high

    The alternator reads above its warning level.· Shorted high
    Check soon

    Causes

    • Real overload or overheat on the system
    • Restricted flow or poor cooling
    • Sensor reading high

    Checks

    1. 1Verify the real value with a separate gauge or probe before replacing anything
    2. 2Check cooling, filters and flow in the system the alternator belongs to
    3. 3Check the sensor wiring if the real value turns out normal
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat D7569Drive battery voltage out of range high

    The drive battery voltage signal is above the valid range the controller accepts, so the reading is treated as a sensor or wiring problem rather than a real value.· Other
    Check soon

    Causes

    • Signal wire shorted to supply
    • Open sensor ground giving a floating high signal
    • Sensor failed high

    Checks

    1. 1Check the ground wire of the drive battery voltage for continuity
    2. 2Look at the live reading on the display and see if it sits at the top of its scale
    3. 3Test the signal wire for stray voltage with the plug off
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat D7571Drive battery voltage out of range low

    The drive battery voltage signal is below the valid range the controller accepts, so the reading is treated as a sensor or wiring problem rather than a real value.· Other
    Check soon

    Causes

    • Signal wire shorted to ground
    • Open signal wire or missing supply
    • Sensor failed low

    Checks

    1. 1Check the supply voltage at the drive battery voltage plug with the key on
    2. 2Look at the live reading on the display and see if it sits at the bottom of its scale
    3. 3Test the signal wire to ground with the plug off
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

Shared checks

Checks, in order

  1. 1Measure battery voltage with the engine off and again running; running voltage should be clearly above resting voltage, in the normal 12 to 14 V range.
  2. 2Check battery terminals, the main ground strap and the controller ground points for tight, clean connections.
  3. 3Check the alternator belt tension and the alternator output wire connection.
  4. 4Measure voltage at the named controller connector while loaded; a drop between the battery and the controller points to a high-resistance connection.
  5. 5Disconnect suspect loads one at a time to find a part pulling the supply down.

Causes

  • Battery terminals or ground straps loose or corroded
  • Alternator not charging or over-charging, or its belt slipping
  • Harness short pulling the supply down
  • Failed component loading the shared supply

Most common here: shorted high (12 of 35)

Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

When to stop

You'll notice: A voltage warning shows and several other codes may follow because the controllers depend on the same supply; the machine can restart badly or lose function when voltage sags.

Most sensor and wiring faults can be traced with a multimeter and the wiring diagram. Disconnect the battery before unplugging controllers; if the controller itself is suspect or needs programming, that needs the dealer’s service tool.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.