EF Logo

Bobcat · Electrical

Bobcat HVAC climate control outputs and sensors fault codes

The heating and air-conditioning unit is run by controller outputs for the blower, compressor clutch, water valve and relay, and read by inside, device and coil temperature sensors. A code names the output or sensor and the way its circuit failed.

FaultCheckB1050-12Bobcat · HVAC climate control outputs and sensors
Code shows hereFAULTB1050-12

Where this code shows

On touchscreen R-series machines, touch the screen and pick Service Codes from the menu.

What do these codes mean?

Bobcat codes B1050-12 to M6803 are all about the hVAC climate control outputs and sensors. The most common failure type is shorted low (4 of 16); none needs an immediate stop. Start with this check: switch the A/C and heater on and listen for the compressor clutch and blower to confirm which output is dead.

How urgent are they?

None of the 16 codes here means stop now; all 16 can wait until the shift ends, but find the cause before the next one.

  • Check soon16

What should I check first?

Switch the A/C and heater on and listen for the compressor clutch and blower to confirm which output is dead.

Shared checks

16 of 16

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Bobcat B1050-12HVAC output short to battery

    The controller reads the hvac output circuit tied to battery voltage when it should only be switched by the controller.· Shorted high
    Check soon

    Causes

    • Output wire rubbed through at the HVAC unit connector behind the seat and touching a live supply wire
    • Water or corrosion in the plug bridging a pin to a power pin
    • Controller output stage failed shorted to supply

    Checks

    1. 1Unplug the hvac output at the HVAC unit connector behind the seat and check its output wire for voltage with the key on; any voltage with the load removed is a short to supply.
    2. 2Trace the wire back from the HVAC output for chafing next to live supply wires and for melted insulation.
    3. 3Replace the HVAC output only if the wire reads clean and the part itself reads shorted.
    4. 4Turn the A/C and heater controls through their range and listen for the clutch to engage and the blower speeds to change.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat B1050-14HVAC output short to ground or open circuit

    The controller cannot tell whether the hvac output circuit is shorted to ground or open, because both read the same on this output, so the heating or cooling function does not respond.· Shorted low
    Check soon

    Causes

    • Wire broken or pin backed out at the HVAC unit connector behind the seat
    • Wire chafed to the frame
    • The HVAC output failed open or shorted

    Checks

    1. 1Unplug the hvac output and measure the output wire to ground; a reading near zero is a short, infinite resistance at the part is an open.
    2. 2Check the connector at the HVAC unit connector behind the seat for pushed-back pins before measuring.
    3. 3Measure the resistance of the HVAC output with the plug off and compare with a new part's specification.
    4. 4Turn the A/C and heater controls through their range and listen for the clutch to engage and the blower speeds to change.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat B1051-93HVAC inside sensor in error

    The controller reports a failure on the hvac inside sensor without saying whether it is open, shorted or stuck, so the climate control reads the wrong temperature and heating or cooling is poor.· Other
    Check soon

    Causes

    • Driver damaged by an earlier short or overload
    • Corroded or loose connector at the sensor connector under the dash
    • Intermittent break in the harness
    • Controller output stage failed

    Checks

    1. 1Read the other active codes for the hvac inside sensor; a short or open code beside this one narrows the cause.
    2. 2Reseat the connector at the sensor connector under the dash and clear the code to see whether it returns.
    3. 3Measure voltage at the plug while the output is commanded to see whether the controller drives it at all.
    4. 4Unplug the HVAC sensor and measure its resistance, then warm it in your hand and confirm the reading changes smoothly.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat B1052-93HVAC device sensor in error

    The controller reports a failure on the hvac device sensor without saying whether it is open, shorted or stuck, so the climate control reads the wrong temperature and heating or cooling is poor.· Other
    Check soon

    Causes

    • Driver damaged by an earlier short or overload
    • Corroded or loose connector at the sensor connector under the dash
    • Intermittent break in the harness
    • Controller output stage failed

    Checks

    1. 1Read the other active codes for the hvac device sensor; a short or open code beside this one narrows the cause.
    2. 2Reseat the connector at the sensor connector under the dash and clear the code to see whether it returns.
    3. 3Measure voltage at the plug while the output is commanded to see whether the controller drives it at all.
    4. 4Unplug the HVAC sensor and measure its resistance, then warm it in your hand and confirm the reading changes smoothly.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat B1053-93HVAC coil sensor in error

    The controller reports a failure on the hvac coil sensor without saying whether it is open, shorted or stuck, so the climate control reads the wrong temperature and heating or cooling is poor.· Other
    Check soon

    Causes

    • Driver damaged by an earlier short or overload
    • Corroded or loose connector at the sensor connector under the dash
    • Intermittent break in the harness
    • Controller output stage failed

    Checks

    1. 1Read the other active codes for the hvac coil sensor; a short or open code beside this one narrows the cause.
    2. 2Reseat the connector at the sensor connector under the dash and clear the code to see whether it returns.
    3. 3Measure voltage at the plug while the output is commanded to see whether the controller drives it at all.
    4. 4Unplug the HVAC sensor and measure its resistance, then warm it in your hand and confirm the reading changes smoothly.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat B1054-11HVAC clutch output error off

    The controller sees the hvac clutch output off when it was commanded on, so the heating or cooling function does not respond.· Shorted low
    Check soon

    Causes

    • Open or grounded output wire
    • The HVAC output failed open
    • Blown fuse or missing supply to the circuit

    Checks

    1. 1Check the fuse and supply to the hvac clutch output circuit with the key on.
    2. 2Measure the resistance of the HVAC output and look for an open or a short to its body.
    3. 3Command the function and measure voltage at the hvac clutch output plug; none means a wiring or controller fault.
    4. 4Turn the A/C and heater controls through their range and listen for the clutch to engage and the blower speeds to change.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat B1054-12HVAC clutch output error on

    The controller sees the hvac clutch output switched on when it was commanded off, so the cooling or heating runs continuously.· Other
    Check soon

    Causes

    • Output wire shorted to a live supply
    • Relay or driver stuck closed
    • Controller output stage failed and cannot switch off

    Checks

    1. 1Unplug the hvac clutch output at the HVAC unit connector behind the seat with the key on; if the controller still reads it on, the fault is in the wiring or controller.
    2. 2Check the output wire for contact with a power wire along its run.
    3. 3Listen and feel for the HVAC output energising while it should be off.
    4. 4Turn the A/C and heater controls through their range and listen for the clutch to engage and the blower speeds to change.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat B1054-13HVAC clutch output open circuit

    The controller sees an open circuit on the hvac clutch output, so no current can flow through it and the heating or cooling function does not respond.· Open circuit
    Check soon

    Causes

    • Pin backed out of the connector or plug not latched at the HVAC unit connector behind the seat
    • Wire broken inside its insulation near a bend or clamp
    • The HVAC output burnt open or its internal lead broken

    Checks

    1. 1Check that the hvac clutch output connector at the HVAC unit connector behind the seat is fully seated and its lock tab engaged.
    2. 2Measure the resistance of the HVAC output with the plug off; an infinite reading confirms an open.
    3. 3Check continuity of each wire from the hvac clutch output plug back to the controller connector, flexing the harness as you go.
    4. 4Turn the A/C and heater controls through their range and listen for the clutch to engage and the blower speeds to change.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Bobcat B1054-19HVAC clutch output overcurrent

    The controller measured too much current on the hvac clutch output output and switched it off to protect its driver, so the heating or cooling function does not respond until the overload is cleared.· Real condition
    Check soon

    Causes

    • Coil shorted between turns so it draws too much current
    • Wiring partly shorted to ground at the HVAC unit connector behind the seat
    • Wrong or damaged part fitted that loads the output

    Checks

    1. 1Measure the resistance of the HVAC output with the plug off and compare it with a matching part on the same machine.
    2. 2Check the hvac clutch output wire for a partial short to ground that only shows when the machine is hot or vibrating.
    3. 3Replace the part and clear the code; if it returns at once, suspect the controller output.
    4. 4Turn the A/C and heater controls through their range and listen for the clutch to engage and the blower speeds to change.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Bobcat B1055-93HVAC water valve in error

    The controller reports a failure on the hvac water valve without saying whether it is open, shorted or stuck, so the heating or cooling function does not respond.· Other
    Check soon

    Causes

    • Driver damaged by an earlier short or overload
    • Corroded or loose connector at the HVAC unit connector behind the seat
    • Intermittent break in the harness
    • Controller output stage failed

    Checks

    1. 1Read the other active codes for the hvac water valve; a short or open code beside this one narrows the cause.
    2. 2Reseat the connector at the HVAC unit connector behind the seat and clear the code to see whether it returns.
    3. 3Measure voltage at the plug while the output is commanded to see whether the controller drives it at all.
    4. 4Turn the A/C and heater controls through their range and listen for the clutch to engage and the blower speeds to change.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M6702HVAC output error on

    The controller sees the hvac output switched on when it was commanded off, so the cooling or heating runs continuously.· Other
    Check soon

    Causes

    • Output wire shorted to a live supply
    • Relay or driver stuck closed
    • Controller output stage failed and cannot switch off

    Checks

    1. 1Unplug the hvac output at the HVAC unit connector behind the seat with the key on; if the controller still reads it on, the fault is in the wiring or controller.
    2. 2Check the output wire for contact with a power wire along its run.
    3. 3Listen and feel for the HVAC output energising while it should be off.
    4. 4Turn the A/C and heater controls through their range and listen for the clutch to engage and the blower speeds to change.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M6703HVAC output error off

    The controller sees the hvac output off when it was commanded on, so the heating or cooling function does not respond.· Shorted low
    Check soon

    Causes

    • Open or grounded output wire
    • The HVAC output failed open
    • Blown fuse or missing supply to the circuit

    Checks

    1. 1Check the fuse and supply to the hvac output circuit with the key on.
    2. 2Measure the resistance of the HVAC output and look for an open or a short to its body.
    3. 3Command the function and measure voltage at the hvac output plug; none means a wiring or controller fault.
    4. 4Turn the A/C and heater controls through their range and listen for the clutch to engage and the blower speeds to change.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat M6707HVAC output open circuit

    The controller sees an open circuit on the hvac output, so no current can flow through it and the heating or cooling function does not respond.· Open circuit
    Check soon

    Causes

    • Pin backed out of the connector or plug not latched at the HVAC unit connector behind the seat
    • Wire broken inside its insulation near a bend or clamp
    • The HVAC output burnt open or its internal lead broken

    Checks

    1. 1Check that the hvac output connector at the HVAC unit connector behind the seat is fully seated and its lock tab engaged.
    2. 2Measure the resistance of the HVAC output with the plug off; an infinite reading confirms an open.
    3. 3Check continuity of each wire from the hvac output plug back to the controller connector, flexing the harness as you go.
    4. 4Turn the A/C and heater controls through their range and listen for the clutch to engage and the blower speeds to change.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Bobcat M6728HVAC output failure

    The controller reports a failure on the hvac output without saying whether it is open, shorted or stuck, so the heating or cooling function does not respond.· Other
    Check soon

    Causes

    • Driver damaged by an earlier short or overload
    • Corroded or loose connector at the HVAC unit connector behind the seat
    • Intermittent break in the harness
    • Controller output stage failed

    Checks

    1. 1Read the other active codes for the hvac output; a short or open code beside this one narrows the cause.
    2. 2Reseat the connector at the HVAC unit connector behind the seat and clear the code to see whether it returns.
    3. 3Measure voltage at the plug while the output is commanded to see whether the controller drives it at all.
    4. 4Turn the A/C and heater controls through their range and listen for the clutch to engage and the blower speeds to change.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M6802HVAC relay error on

    The controller sees the hvac relay switched on when it was commanded off, so the cooling or heating runs continuously.· Other
    Check soon

    Causes

    • Output wire shorted to a live supply
    • Relay or driver stuck closed
    • Controller output stage failed and cannot switch off

    Checks

    1. 1Unplug the hvac relay at the HVAC unit connector behind the seat with the key on; if the controller still reads it on, the fault is in the wiring or controller.
    2. 2Check the output wire for contact with a power wire along its run.
    3. 3Listen and feel for the HVAC output energising while it should be off.
    4. 4Turn the A/C and heater controls through their range and listen for the clutch to engage and the blower speeds to change.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M6803HVAC relay error off

    The controller sees the hvac relay off when it was commanded on, so the heating or cooling function does not respond.· Shorted low
    Check soon

    Causes

    • Open or grounded output wire
    • The HVAC output failed open
    • Blown fuse or missing supply to the circuit

    Checks

    1. 1Check the fuse and supply to the hvac relay circuit with the key on.
    2. 2Measure the resistance of the HVAC output and look for an open or a short to its body.
    3. 3Command the function and measure voltage at the hvac relay plug; none means a wiring or controller fault.
    4. 4Turn the A/C and heater controls through their range and listen for the clutch to engage and the blower speeds to change.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

Shared checks

Checks, in order

  1. 1Switch the A/C and heater on and listen for the compressor clutch and blower to confirm which output is dead.
  2. 2Check the HVAC fuse and measure voltage at the clutch or blower plug while the function is commanded.
  3. 3Swap the HVAC relay with an identical one and see whether the code follows it.
  4. 4Unplug an HVAC temperature sensor and measure its resistance, warming it in your hand to see it change.
  5. 5Inspect the cab harness behind the dash and at the door pillar for pinched or broken wires.

Causes

  • Blower, compressor clutch or water valve coil failed
  • HVAC relay stuck or its socket loose
  • Temperature sensor connector corroded behind the dash
  • Harness fatigue where the cab harness flexes at the door pillar

Most common here: shorted low (4 of 16)

Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

When to stop

You'll notice: The cab does not heat or cool, the compressor clutch does not engage, or the climate control shows a wrong temperature.

Lower attachments to the ground and relieve hydraulic pressure before loosening any fitting. Never feel for a leak with your hand - oil under pressure can inject through skin.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.