Controllers feed their sensors from a regulated supply, normally 5 V and on some modules 8 V. A code means a controller measured its sensor supply out of range high or low.
More about these partsLess
Every sensor on that supply shares the fault, so a single shorted sensor can pull the whole supply down.
Where this code shows
On touchscreen R-series machines, touch the screen and pick Service Codes from the menu.
What do these codes mean?
Bobcat codes 32-65 to D7586 are all about the sensor supply voltages (5 V, 8 V and other). None needs an immediate stop. Start with this check: note which sensors are faulting at the same time; the shared supply names the group to test.
How urgent are they?
None of the 26 codes here means stop now; all 26 can wait until the shift ends, but find the cause before the next one.
- Check soon26
What should I check first?
Note which sensors are faulting at the same time; the shared supply names the group to test.
Shared checks26 of 26
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
Bobcat 32-65Sensor supply voltage out of range
Sensor supply voltage out of range: same fault as W3265 (the signal is outside its allowed range), here on the sensor supply voltage.· OtherOtherCheck soonCauses
- Sensor drifting or failed
- Poor connection
Checks
- 1Compare the sensor supply voltage reading on screen with the real condition.
- 2Test steps: see W3265.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat B102A-16Cab controller sensor supply voltage out of range low
Cab controller sensor supply voltage out of range low: same fault as A4622 (the signal is below its normal range), here on the cab controller sensor supply voltage.· OtherOtherCheck soonCauses
- Signal wire shorted to ground
- Supply wire to the sensor open or the sensor not powered
Checks
- 1Measure the 5 V reference and the signal wire to ground at the cab controller sensor supply voltage plug.
- 2Test steps: see A4622.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat B102A-17Cab controller sensor supply voltage out of range high
Cab controller sensor supply voltage out of range high: same fault as A4621 (the signal is above its normal range), here on the cab controller sensor supply voltage.· OtherOtherCheck soonCauses
- Signal wire shorted to the 5 V or battery supply
- Sensor failed with its output pinned high
Checks
- 1Unplug the cab controller sensor supply voltage and measure the signal wire for a short to supply.
- 2Test steps: see A4621.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat C1002-16Sensor supply out of range low
Sensor supply out of range low: same fault as A4622 (the signal is below its normal range), here on the sensor supply.· OtherOtherCheck soonCauses
- Signal wire shorted to ground
- Supply wire to the sensor open or the sensor not powered
Checks
- 1Measure the 5 V reference and the signal wire to ground at the sensor supply plug.
- 2Test steps: see A4622.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat C1002-17Sensor supply out of range high
Sensor supply out of range high: same fault as A4621 (the signal is above its normal range), here on the sensor supply.· OtherOtherCheck soonCauses
- Signal wire shorted to the 5 V or battery supply
- Sensor failed with its output pinned high
Checks
- 1Unplug the sensor supply and measure the signal wire for a short to supply.
- 2Test steps: see A4621.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat W3265ACS sensor supply voltage out of range
The controller reads the sensor supply sensor supply voltage outside its allowed range without saying whether it is high or low, so the sensors on that supply read wrong and their functions fall back to a safe state. Find which sensors share this supply on the wiring diagram, then unplug them one at a time while watching the reading.· OtherOtherCheck soonCauses
- Sensor drifting or failed
- Poor connection at the first sensor connector on the supply branch
- Wiring damage
- Real condition beyond the sensor range
Checks
- 1Compare the sensor supply value on the service screen with the real condition before replacing anything.
- 2Reseat the connector at the first sensor connector on the supply branch and check it for corrosion.
- 3Check the supply and ground at the sensor plug.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat A46215v sensor supply out of range high
The controller reads the sensor supply sensor supply voltage above its normal range, which is usually a wire shorted to supply or a sensor that has failed high, so the sensors on that supply read wrong and their functions fall back to a safe state. Find which sensors share this supply on the wiring diagram, then unplug them one at a time while watching the reading.· Shorted highShorted highCheck soonCauses
- Signal wire shorted to the 5 V or battery supply
- Sensor failed with its output pinned high
- Ground wire open so the signal floats high
- Water in the connector bridging signal to supply
Checks
- 1Unplug the sensor supply and measure the signal wire with the key on; a high voltage with the sensor removed means a short in the harness.
- 2Check the sensor ground at the plug; an open ground drives the signal high.
- 3Measure the 5 V reference at the sensor supply plug to confirm it is not above 5 V.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Bobcat H46215 volt sensor supply out of range high
5 volt sensor supply out of range high: same fault as A4621 (the signal is above its normal range), here on the 5 volt sensor supply.· OtherOtherCheck soonCauses
- Signal wire shorted to the 5 V or battery supply
- Sensor failed with its output pinned high
Checks
- 1Unplug the 5 volt sensor supply and measure the signal wire for a short to supply.
- 2Test steps: see A4621.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat M46215v sensor supply out of range high
5v sensor supply out of range high: same fault as A4621 (the signal is above its normal range), here on the 5v sensor supply.· OtherOtherCheck soonCauses
- Signal wire shorted to the 5 V or battery supply
- Sensor failed with its output pinned high
Checks
- 1Unplug the 5v sensor supply and measure the signal wire for a short to supply.
- 2Test steps: see A4621.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat A46225v sensor supply out of range low
The controller reads the sensor supply sensor supply voltage below its normal range, typically a wire shorted to ground, an open supply or a sensor failed low, so the sensors on that supply read wrong and their functions fall back to a safe state. Find which sensors share this supply on the wiring diagram, then unplug them one at a time while watching the reading.· Shorted lowShorted lowCheck soonCauses
- Signal wire shorted to ground
- Supply wire to the sensor open or the sensor not powered
- Sensor failed with its output pinned low
- Pin backed out of the connector
Checks
- 1Measure the 5 V reference at the sensor supply plug; no reference means the fault is in the supply wire, not the sensor.
- 2Unplug the sensor and measure the signal wire to ground for a short.
- 3Check the connector at the first sensor connector on the supply branch for a backed-out pin.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Bobcat H46225 volt sensor supply out of range low
5 volt sensor supply out of range low: same fault as A4622 (the signal is below its normal range), here on the 5 volt sensor supply.· OtherOtherCheck soonCauses
- Signal wire shorted to ground
- Supply wire to the sensor open or the sensor not powered
Checks
- 1Measure the 5 V reference and the signal wire to ground at the 5 volt sensor supply plug.
- 2Test steps: see A4622.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat M46225v sensor supply out of range low
5v sensor supply out of range low: same fault as A4622 (the signal is below its normal range), here on the 5v sensor supply.· OtherOtherCheck soonCauses
- Signal wire shorted to ground
- Supply wire to the sensor open or the sensor not powered
Checks
- 1Measure the 5 V reference and the signal wire to ground at the 5v sensor supply plug.
- 2Test steps: see A4622.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat A47218v sensor supply out of range high
8v sensor supply out of range high: same fault as A4621 (the signal is above its normal range), here on the 8v sensor supply.· OtherOtherCheck soonCauses
- Signal wire shorted to the 5 V or battery supply
- Sensor failed with its output pinned high
Checks
- 1Unplug the 8v sensor supply and measure the signal wire for a short to supply.
- 2Test steps: see A4621.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat H4721Sensor supply 1 out of range high
Sensor supply 1 out of range high: same fault as A4621 (the signal is above its normal range), here on the sensor supply 1.· OtherOtherCheck soonCauses
- Signal wire shorted to the 5 V or battery supply
- Sensor failed with its output pinned high
Checks
- 1Unplug the sensor supply 1 and measure the signal wire for a short to supply.
- 2Test steps: see A4621.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat M47218v sensor supply out of range high
8v sensor supply out of range high: same fault as A4621 (the signal is above its normal range), here on the 8v sensor supply.· OtherOtherCheck soonCauses
- Signal wire shorted to the 5 V or battery supply
- Sensor failed with its output pinned high
Checks
- 1Unplug the 8v sensor supply and measure the signal wire for a short to supply.
- 2Test steps: see A4621.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat W4721Sensor supply out of range high
Sensor supply out of range high: same fault as A4621 (the signal is above its normal range), here on the sensor supply.· OtherOtherCheck soonCauses
- Signal wire shorted to the 5 V or battery supply
- Sensor failed with its output pinned high
Checks
- 1Unplug the sensor supply and measure the signal wire for a short to supply.
- 2Test steps: see A4621.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat A47228v sensor supply out of range low
8v sensor supply out of range low: same fault as A4622 (the signal is below its normal range), here on the 8v sensor supply.· OtherOtherCheck soonCauses
- Signal wire shorted to ground
- Supply wire to the sensor open or the sensor not powered
Checks
- 1Measure the 5 V reference and the signal wire to ground at the 8v sensor supply plug.
- 2Test steps: see A4622.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat H4722Sensor supply 1 out of range low
Sensor supply 1 out of range low: same fault as A4622 (the signal is below its normal range), here on the sensor supply 1.· OtherOtherCheck soonCauses
- Signal wire shorted to ground
- Supply wire to the sensor open or the sensor not powered
Checks
- 1Measure the 5 V reference and the signal wire to ground at the sensor supply 1 plug.
- 2Test steps: see A4622.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat M47228v sensor supply out of range low
8v sensor supply out of range low: same fault as A4622 (the signal is below its normal range), here on the 8v sensor supply.· OtherOtherCheck soonCauses
- Signal wire shorted to ground
- Supply wire to the sensor open or the sensor not powered
Checks
- 1Measure the 5 V reference and the signal wire to ground at the 8v sensor supply plug.
- 2Test steps: see A4622.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat W4722Sensor supply out of range low
Sensor supply out of range low: same fault as A4622 (the signal is below its normal range), here on the sensor supply.· OtherOtherCheck soonCauses
- Signal wire shorted to ground
- Supply wire to the sensor open or the sensor not powered
Checks
- 1Measure the 5 V reference and the signal wire to ground at the sensor supply plug.
- 2Test steps: see A4622.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat H48215v sensor supply out of range high
5v sensor supply out of range high: same fault as A4621 (the signal is above its normal range), here on the 5v sensor supply.· OtherOtherCheck soonCauses
- Signal wire shorted to the 5 V or battery supply
- Sensor failed with its output pinned high
Checks
- 1Unplug the 5v sensor supply and measure the signal wire for a short to supply.
- 2Test steps: see A4621.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat H48225v sensor supply out of range low
5v sensor supply out of range low: same fault as A4622 (the signal is below its normal range), here on the 5v sensor supply.· OtherOtherCheck soonCauses
- Signal wire shorted to ground
- Supply wire to the sensor open or the sensor not powered
Checks
- 1Measure the 5 V reference and the signal wire to ground at the 5v sensor supply plug.
- 2Test steps: see A4622.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat D7537Drive 5 volt sensor supply 1 out of range low
Drive 5 volt sensor supply 1 out of range low: same fault as A4622 (the signal is below its normal range), here on the 5 volt sensor supply 1.· OtherOtherCheck soonCauses
- Signal wire shorted to ground
- Supply wire to the sensor open or the sensor not powered
Checks
- 1Measure the 5 V reference and the signal wire to ground at the 5 volt sensor supply 1 plug.
- 2Test steps: see A4622.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat D7538Drive+ sensor supply 2 out of range low
Drive+ sensor supply 2 out of range low: same fault as A4622 (the signal is below its normal range), here on the sensor supply 2.· OtherOtherCheck soonCauses
- Signal wire shorted to ground
- Supply wire to the sensor open or the sensor not powered
Checks
- 1Measure the 5 V reference and the signal wire to ground at the sensor supply 2 plug.
- 2Test steps: see A4622.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat D7585Drive 5 volt sensor supply 1 out of range high
Drive 5 volt sensor supply 1 out of range high: same fault as A4621 (the signal is above its normal range), here on the 5 volt sensor supply 1.· OtherOtherCheck soonCauses
- Signal wire shorted to the 5 V or battery supply
- Sensor failed with its output pinned high
Checks
- 1Unplug the 5 volt sensor supply 1 and measure the signal wire for a short to supply.
- 2Test steps: see A4621.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Bobcat D7586Drive+ sensor supply 2 out of range high
Drive+ sensor supply 2 out of range high: same fault as A4621 (the signal is above its normal range), here on the sensor supply 2.· OtherOtherCheck soonCauses
- Signal wire shorted to the 5 V or battery supply
- Sensor failed with its output pinned high
Checks
- 1Unplug the sensor supply 2 and measure the signal wire for a short to supply.
- 2Test steps: see A4621.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Shared checks
Checks, in order
- 1Note which sensors are faulting at the same time; the shared supply names the group to test.
- 2Measure the supply voltage at the controller with all sensors connected, then unplug sensors on that supply one at a time and watch for the voltage recovering.
- 3Check shared connectors and junction points for water and corrosion between the supply and the signal pins.
- 4Measure the wire from the controller supply pin to the first sensor for a short to ground or to battery with the plug off.
- 5Suspect the controller only after every sensor and the wiring on that supply test clean.
Causes
- One sensor on the shared supply shorted internally
- Supply wire shorted to ground or to battery in the harness
- Water in a shared connector bridging the supply to another pin
- Controller supply regulator failed
When to stop
You'll notice: Several sensor or input codes appear at once, and functions that rely on position or pressure sensors stop working or go to a safe state.
Most sensor and wiring faults can be traced with a multimeter and the wiring diagram. Disconnect the battery before unplugging controllers; if the controller itself is suspect or needs programming, that needs the dealer’s service tool.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
- Bobcat Service Code List (rev. 10-20, M-Series/R-Series loaders and M-Series excavators)
- Bobcat S205 Operation & Maintenance Manual, service codes list
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.