Skyjack · GP102 module LED flash codes
Skyjack Fault Code 2‑1
Elevation switch shifted?
What does Skyjack code 2-1 mean?
The module sees the elevation switch change state at a platform position where it should not. That points at the switch, its mounting or the arm that operates it. Urgency: check soon - the machine may derate or limit a function. Check first: raise and lower the platform slowly and watch the switch operate; it must change state at the same point every time.
Can I keep running with it?
Check soon
The machine may derate or limit a function. Find the cause before the next shift.
What should I check first?
Raise and lower the platform slowly and watch the switch operate; it must change state at the same point every time
Then 4 more checksWhere this code shows
Find the LED on the GP102 module (older SJIII scissors) or the display and keypad in the hydraulic tray (Skycoded machines).
Checks
0 of 5 done
Causes
- Elevation switch loose on its bracket so it has moved out of position
- Operating arm or cam bent or worn
- Switch contacts dirty or intermittent
- Wire rubbing at the scissor arm pivot
How it failed
You'll notice: Drive and lift can be cut because the machine thinks the platform is in the wrong height zone.
OtherRead from how the source describes the code
The source does not say how this one failed.
- Meter test
- Read the code with the service tool and note which other codes are active with it.
- Good result
- Codes that appear together usually share one cause - start with the wiring they share.
When to stop
Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.
Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Same part, other failures: Tilt, overload, armguard and elevation switch codes
- 1-2Vehicle overloadedReal conditionInformation
- 1-3Armguard active (lift and drive stopped)OtherInformation
- 1-4Too high, drive preventedReal conditionInformation
- 1-5Too high, lift up preventedReal conditionInformation
- 2-1Elevation switch shifted?OtherCheck soon
- 2-2Elevation switch stuck?OtherCheck soon
- 2-3Armguard active (one-off flash)OtherInformation
- F06Calibration F06: elevation switch closed at startPart or controllerCheck soon
- F08Calibration F08: elevation switch closed at topPart or controllerCheck soon
Show the other 8 codesHide the other codes
- 1-1Vehicle tiltedOtherInformation
- F15Calibration F15: elevation switch closed at bottomPart or controllerCheck soon
- F16Calibration F16: elevation switch opened too lowPart or controllerCheck soon
- F17Calibration F17: elevation switch opened too highPart or controllerCheck soon
- F18Calibration F18: elevation switch closed too lowPart or controllerCheck soon
- F19Calibration F19: elevation switch closed too highPart or controllerCheck soon
- F46Calibration F46: elevation switch opened twicePart or controllerCheck soon
- F47Calibration F47: elevation switch closed twicePart or controllerCheck soon
Other Skyjack codes: GP102 module LED flash codes
Source
This source lists 2-1 and its meaning. The guidance on this page is general, not taken from it.
The source covers: Skyjack SJIII 3215 and 3219 DC electric scissors with the GP102 module (manual 155147AD, serials 10,000,574-10,000,630 and 22,019,597-22,022,792); later serial ranges can differ, check your own manual.
Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.