Skyjack · GP102 module LED flash codes
Skyjack P3, P4, P5 output shorts and supply voltage fault codes
This page covers the GP102 output shorts on the P3, P4 and P5 connectors and the supply voltage, drive and lift input codes. These codes appear when the GP102 sees an output pin pulled to supply or to 0 V when it should not be.
More about these partsLess
The GP102 needs a healthy battery supply on its B+ pin and sensible inputs from the drive and lift controls before it allows any function.
Where this code shows
Find the LED on the GP102 module (older SJIII scissors) or the display and keypad in the hydraulic tray (Skycoded machines).
What do these codes mean?
Skyjack codes 4-1 to 5-6 are all about the p3, P4, P5 output shorts and supply voltage. The most common failure type is shorted high (3 of 11); 6 need an immediate stop. Start with this check: disconnect plug P3 or P4 as the manual says and see whether the code clears.
How urgent are they?
6 of 11 codes here mean stop now; 4 can wait until the shift ends, but find the cause before the next one; 1 is information only.
- Stop now6
- Check soon4
- Info1
What should I check first?
Disconnect plug P3 or P4 as the manual says and see whether the code clears
Shared checks11 of 11
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
Skyjack 4-1P4-1 or P5-1 short to 0 V
The module sees the sensor supply on plug P4 pin 1 or plug P5 pin 1 pulled to ground. Those pins feed the sensors, so a short takes out the readings the module needs before it will allow lift.· OtherOtherStop nowCauses
- Sensor supply wire on P4-1 or P5-1 chafed against the frame
- Cable pinched at the scissor pivot or under a cover
- Failed pressure or height transducer pulling its supply to ground
- Water in the P4 or P5 plug
Checks
- 1With the key off unplug P4 and see if the fault clears; the manual points at the wiring from P4-1 to the rest of the machine if it does
- 2Do the same with P5 to separate the two circuits
- 3Check continuity from each pin 1 to chassis ground with the plugs removed; there should be none
- 4Trace the harness for rubbed insulation at the arms and along the frame rails
- 5Unplug the transducers one at a time to find which one pulls the supply down
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Skyjack 4-2P3-4 short to supply
The module reads the wire on P3 pin 4 as connected to battery positive. Skyjack gives one wiring test for all the P3 pin 4 and pin 6 faults: unplug P3 and see if the fault clears.· Shorted highShorted highStop nowCauses
- P3-4 wire chafed against a live battery positive conductor or terminal
- Pins touching inside the P3 plug
- Damaged cable at a moving point shorting the wire to supply
- Device on the P3-4 circuit with an internal short to supply
Checks
- 1Unplug P3 with the key off; if the fault clears the problem is in the wiring from P3-4 outward
- 2With the plug off, measure P3-4 to battery positive; there should be no continuity
- 3Inspect the P3 plug pins for bridging or damaged seals
- 4Follow the P3-4 wire looking for rubbed insulation next to battery cables
- 5Repair the harness and clear the code by cycling power
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Skyjack 4-3P3-4 short to 0 V
The module reads the wire on P3 pin 4 pulled to ground. It is the opposite fault to 4-2 on the same pin, so the hunt is for a path to the chassis rather than to battery positive.· OtherOtherStop nowCauses
- P3-4 insulation worn through against the frame
- Water or corrosion in the P3 plug leaking to ground
- Device on the P3-4 circuit shorted internally to ground
- Wire pinched under a bracket
Checks
- 1Disconnect P3 with the key off; if the fault clears, the wire from P3-4 outward is at fault
- 2Measure resistance from P3-4 to chassis with the plug off; a reading near zero confirms a short to ground
- 3Check the plug for water and green corrosion on the pin 4 terminal
- 4Trace the wire along the frame looking for bright rub spots where it touches metal
- 5After the repair confirm the LED returns to steady on and the function works
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Skyjack 4-4P3-4 short to supply (second message)
The manual lists a second short-to-supply message for P3 pin 4, written with a question mark. It is the same wire as 4-2 so the same unplug-and-test approach applies.· Shorted highShorted highStop nowCauses
- Short to battery positive on the P3-4 wire
- Moisture bridging pins in the P3 plug
- Harness pinched at a cover or bracket
Checks
- 1Unplug P3 and note whether the LED changes; the manual says to look at the P3-4 wiring if it clears
- 2Measure P3-4 to battery positive with the key off and the plug removed
- 3Inspect the plug seals and pin tension for a pin touching its neighbour
- 4If 4-2 also appears at other times, treat both as one wiring problem
- 5Run the function after the repair to confirm the code does not return
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Skyjack 4-5P3-6 short to 0 V
The module reads the wire on P3 pin 6 shorted to ground. It is the P3-6 version of 4-3, so the fault is on the other pin of the same plug.· Shorted lowShorted lowStop nowCauses
- P3-6 wire rubbed through to the frame
- Corrosion in the P3 plug leaking to ground
- Device on the P3-6 circuit with an internal short
- Cable pinched on a moving arm
Checks
- 1Unplug P3 with the key off and see whether the fault clears; the manual points at the P3-6 wiring if it does
- 2Measure P3-6 to chassis ground with the plug removed and expect no continuity
- 3Inspect the P3 plug for water, bent pins and a split seal around pin 6
- 4Follow the P3-6 wire for chafing near cable clamps and moving arms
- 5Replace the damaged wire section and re-test the function
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Skyjack 4-6P3-6 short to supply
The module reads the wire on P3 pin 6 touching battery positive. It is the P3-6 counterpart of 4-2 and uses the same plug-disconnect test.· Shorted highShorted highStop nowCauses
- P3-6 wire touching a live terminal or cable somewhere along its run
- Pins bridged inside the P3 plug at pin 6
- Device on the P3-6 circuit with an internal short to supply
Checks
- 1Unplug P3 with the key off; if the fault clears the problem is in the wire from P3-6
- 2Measure P3-6 to battery positive with the plug off and look for any continuity
- 3Look inside the plug for a bridged pin 6 or a damaged seal
- 4Inspect where the P3-6 wire runs close to the main battery cables
- 5Repair the wire and clear the code by cycling power
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Skyjack 5-1B+ supply too low
The module sees battery voltage on P2 pin 12 below what it needs. Weak batteries, a bad cable or a poor connection can cause this, and it can stop lift and drive.· Lost messageLost messageCheck soonCauses
- Batteries discharged or at end of life
- Loose or corroded battery terminal or main cable
- Master disconnect contacts worn
- Charger faulty so the batteries stay undercharged
Checks
- 1Measure battery voltage at the terminals with the machine on and watch for a drop when lift is used
- 2Measure at P2-12 and compare with the battery terminals; a difference means a bad cable or switch
- 3Check all battery connections and the master disconnect for heat marks or looseness
- 4Charge the batteries fully, then retest to see whether the code stays away
- 5Load test each battery if one of the string is low or the pack will not hold charge
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Skyjack 5-2Waiting for B+ on P2-12 / EMS inputs faulty
The manual's quick chart gives both messages under this code: no battery positive on P2 pin 12, or the emergency stop inputs read wrong. Either way the module will not allow movement.· OtherOtherCheck soonCauses
- Base or platform emergency stop pressed or faulty
- No battery positive reaching P2-12
- Wire or pin fault on the P2 plug
- Master disconnect off
Checks
- 1Check the master disconnect is on and both emergency stops are pulled out
- 2Measure battery positive at P2-12 with the key on to prove the supply reaches the module
- 3Check the inputs on P2 pins 1 to 8, as the manual says, for a stuck switch or open wire
- 4Inspect the P2 plug for backed-out pins or corrosion on the terminals
- 5Compare the switch states with the wiring diagram for your serial number
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Skyjack 5-4Up/down select inputs active together
The module sees the lift up and lift down inputs on at the same time, which normal operation cannot produce. It stops lift until the conflict clears.· OtherOtherCheck soonCauses
- Joystick or toggle stuck in both directions
- Short between the up and down wires
- Water in the control box
- Failed switch contacts
Checks
- 1Release every control and see if the code clears by itself
- 2Operate up and down separately and watch both inputs for the one that stays on
- 3Check the control cable for pinching between the up and down conductors
- 4Open the control box and look for water or corrosion on the switch board
- 5Replace the switch if both inputs stay on with the handle released
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Skyjack 5-5Waiting for neutral
The controller will not start a function until the joystick is back in neutral. It is waiting, not failed, and appears if the handle was held over when the machine was powered up.· OtherOtherInfoCauses
- Joystick held off-centre when the machine was switched on
- Joystick not centring because of a weak spring
- Handle input reading off-centre because of a wiring fault
- Control box damaged
Checks
- 1Release the joystick and see if the code clears
- 2Check the handle springs back to centre without sticking
- 3Measure the handle signal at neutral and check it sits at its centre value
- 4Inspect the control cable for damage near the handle
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Skyjack 5-6Drive/lift inputs faulty
The module reads the drive and lift selections in a combination it should not see. It stops both functions until the inputs agree.· OtherOtherCheck soonCauses
- Drive/lift selector switch faulty
- Short between the selector wires
- Damaged control cable
- Water in the platform control box
Checks
- 1Release everything and cycle power to see if the code returns straight away
- 2Test the drive/lift selector for a clean single state in each position
- 3Check for continuity between the selector wires that should be isolated from each other
- 4Inspect the control cable along its length for crush damage
- 5Replace the control box switch if the fault stays after the wiring checks
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Shared checks
Checks, in order
- 1Disconnect plug P3 or P4 as the manual says and see whether the code clears
- 2Measure battery voltage at the module B+ pin with a function operated
- 3If it clears, trace the wiring from that pin to the valve or relay for chafing and water
- 4Check the emergency stop buttons and key switch both pass voltage
- 5Measure the coil resistance of the valve or relay on that output
- 6Check the module inputs on P2 with the handheld tool switches screen
- 7Replace the module only if the code stays with the plug removed
Causes
- Damaged wire from the module plug touching the frame or another wire
- Low or discharged battery
- Coil or relay on the output failed short
- Loose or corroded battery or module supply connection
Most common here: shorted high (3 of 11)
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
When to stop
You'll notice: A function is dead or the machine will not start, and the LED shows a 4-x pattern that stays on until the short is cleared.
Most sensor and wiring faults can be traced with a multimeter and the wiring diagram. Disconnect the battery before unplugging controllers; if the controller itself is suspect or needs programming, that needs the dealer’s service tool.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Sources
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.