EF Logo

Skyjack · GP102 module LED flash codes

Skyjack Fault Code 5‑1

B+ supply too low

What does Skyjack code 5-1 mean?

The module sees battery voltage on P2 pin 12 below what it needs. Weak batteries, a bad cable or a poor connection can cause this, and it can stop lift and drive. Urgency: check soon - the machine may derate or limit a function. Check first: measure battery voltage at the terminals with the machine on and watch for a drop when lift is used.

FaultCheck5-1Skyjack · GP102 module LED flash codes

Can I keep running with it?

Check soon

The machine may derate or limit a function. Find the cause before the next shift.

What should I check first?

Measure battery voltage at the terminals with the machine on and watch for a drop when lift is used

Then 4 more checks
Code shows hereFAULT5-1

Where this code shows

Find the LED on the GP102 module (older SJIII scissors) or the display and keypad in the hydraulic tray (Skycoded machines).

Checks

0 of 5 done

Causes

  • Batteries discharged or at end of life
  • Loose or corroded battery terminal or main cable
  • Master disconnect contacts worn
  • Charger faulty so the batteries stay undercharged

How it failed

You'll notice: The machine feels weak or cuts out under load and the LED shows five flashes then one.

Lost messageRead from how the source describes the code

A module stopped hearing another on the data link, or the data came late or garbled.

Module AModule BCAN HCAN L120 Ω120 Ω
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.
Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good result
About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

When to stop

Most sensor and wiring faults can be traced with a multimeter and the wiring diagram. Disconnect the battery before unplugging controllers; if the controller itself is suspect or needs programming, that needs the dealer’s service tool.

Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Same part, other failures: P3, P4, P5 output shorts and supply voltage

Source

Skyjack SJIII 3215/3219 Service Manual 155147AD (Nov 2013), sections 5.3-2 and 5.3-3, LED Error Codes, pp. 9-11

This source lists 5-1 and its meaning. The guidance on this page is general, not taken from it.

The source covers: Skyjack SJIII 3215 and 3219 DC electric scissors with the GP102 module (manual 155147AD, serials 10,000,574-10,000,630 and 22,019,597-22,022,792); later serial ranges can differ, check your own manual.

Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.