JCB · Communication (CAN / telematics)
JCB NOx sensor CAN data fault codes
The NOx sensors send data over CAN. These codes report errors in that data for the upstream and downstream sensors.
Where this code shows
Switch the key on and note any warning lamp or fault icon on the cluster.
What do these codes mean?
JCB codes U059E-00 to U059F-97 are all about the nOx sensor CAN data. Most are lost message faults; none needs an immediate stop. Start with this check: check the CAN high and low wires to the NOx sensor CAN data for opens, shorts and water.
How urgent are they?
None of the 25 codes here means stop now; all 25 can wait until the shift ends, but find the cause before the next one.
- Check soon25
What should I check first?
Check the CAN high and low wires to the NOx sensor CAN data for opens, shorts and water
Shared checks25 of 25
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
JCB U059E-00Downstream NOx sensor temperature signal CAN error
The downstream NOx sensor (the one after the SCR catalyst) sends a temperature signal over CAN that arrives faulty, so the controller cannot see the sensor's own temperature. The tool shows no sensor temperature while NOx values may still arrive.· Lost messageLost messageCheck soonCauses
- Sensor control unit failing to send its temperature frame
- Intermittent connection at the sensor plug
- Temperature signal scaling wrong after software mismatch
Checks
- 1Read the sensor temperature in the aftertreatment tool and see whether it is missing
- 2Check the sensor plug for corrosion
- 3Look at the sensor plug for a bent CAN pin and fix the terminal tension
- 4Compare the sensor temperature with the exhaust temperature: if the CAN value is stuck at an extreme, suspect the signal and not the bus
- 5Log temperature, NOx and oxygen together; a missing temperature alone points at one signal inside the sensor message.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB U059F-00Upstream NOx sensor temperature signal CAN error
The upstream NOx sensor (the one ahead of the SCR catalyst) sends a temperature signal over CAN that arrives faulty, so the controller cannot see the sensor's own temperature. The tool shows no sensor temperature while NOx values may still arrive.· Lost messageLost messageCheck soonCauses
- Sensor control unit failing to send its temperature frame
- Intermittent connection at the sensor plug
- Temperature signal scaling wrong after software mismatch
Checks
- 1Read the sensor temperature in the aftertreatment tool and see whether it is missing
- 2Check the sensor plug for corrosion
- 3Inspect the harness clips for a lead hanging near the exhaust
- 4Compare the sensor temperature with the exhaust temperature: if the CAN value is stuck at an extreme, suspect the signal and not the bus
- 5Log temperature, NOx and oxygen together; a missing temperature alone points at one signal inside the sensor message.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB U059E-02Upstream NOx sensor CAN bus error
The upstream NOx sensor (the one ahead of the SCR catalyst) has a CAN communication error: its messages are missing or corrupted, so the controller loses the NOx data. All values from this sensor go missing at once.· Lost messageLost messageCheck soonCauses
- CAN wiring to the sensor broken or loose
- Sensor control unit without supply
- Intermittent CAN transceiver in the sensor control unit
Checks
- 1Check the sensor supply and earth at its plug
- 2Check CAN high and low continuity to the sensor
- 3Check the CAN wiring colours at the sensor against the wiring diagram
- 4Watch the sensor message rate on a CAN logger and see whether it drops to nothing during vibration
- 5Park the machine, key off for two minutes, then key on and see how soon the sensor appears in the data list.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB U059F-02Downstream NOx sensor communication error
The downstream NOx sensor (the one after the SCR catalyst) has a CAN communication error: its messages are missing or corrupted, so the controller loses the NOx data. All values from this sensor go missing at once.· Lost messageLost messageCheck soonCauses
- CAN wiring to the sensor broken or loose
- Sensor control unit without supply
- Intermittent CAN transceiver in the sensor control unit
Checks
- 1Check the sensor supply and earth at its plug
- 2Check CAN high and low continuity to the sensor
- 3Clear the code and see how quickly it returns after key-on
- 4Watch the sensor message rate on a CAN logger and see whether it drops to nothing during vibration
- 5Park the machine, key off for two minutes, then key on and see how soon the sensor appears in the data list.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB U059E-08Upstream NOx sensor communication fault
The upstream NOx sensor (the one ahead of the SCR catalyst) reports a CAN communication fault listed under suffix 08 and the source gives no further signal name, so treat it as a general sensor communication loss. The sensor drops out of the data list as if it were switched off.· Lost messageLost messageCheck soonCauses
- CAN wiring to the sensor damaged
- Sensor control unit failure
- Wire pair crossed or swapped after a repair
Checks
- 1Check continuity of the CAN wires to the sensor
- 2Check the sensor supply and earth
- 3Check for chafing where the sensor lead passes an exhaust bracket
- 4Verify CAN high is on the same pin number at the plug as in the wiring diagram
- 5Look in the tool for the sensor's node status and count how many times it has re-announced itself on the bus.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB U059F-08Downstream NOx sensor CAN error
The downstream NOx sensor (the one after the SCR catalyst) reports a CAN communication fault listed under suffix 08 and the source gives no further signal name, so treat it as a general sensor communication loss. The sensor drops out of the data list as if it were switched off.· Lost messageLost messageCheck soonCauses
- CAN wiring to the sensor damaged
- Sensor control unit failure
- Wire pair crossed or swapped after a repair
Checks
- 1Check continuity of the CAN wires to the sensor
- 2Check the sensor supply and earth
- 3Look at the sensor plug for a bent CAN pin and fix the terminal tension
- 4Verify CAN high is on the same pin number at the plug as in the wiring diagram
- 5Look in the tool for the sensor's node status and count how many times it has re-announced itself on the bus.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB U059E-9AUpstream NOx sensor heater ratio CAN error
The upstream NOx sensor (the one ahead of the SCR catalyst) sends the heater ratio signal with a CAN error, so the controller cannot tell how hard the sensor heater is working. Only the heater ratio is missing; the sensor may still measure NOx.· Lost messageLost messageCheck soonCauses
- Sensor control unit sending a corrupted heater ratio
- Weak heater circuit in the sensor
- Heater controller inside the sensor drawing abnormal current
Checks
- 1Read the heater ratio on live data
- 2Check the sensor supply voltage
- 3Read the sensor module's own hardware and software version in the tool
- 4Measure the heater current in the tool and compare it with a good sensor
- 5Observe how the heater ratio changes in the first minute after start and note whether it ever settles.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB U059F-9ADownstream NOx sensor CAN error (code 9A)
The downstream NOx sensor (the one after the SCR catalyst) sends the heater ratio signal with a CAN error, so the controller cannot tell how hard the sensor heater is working. Only the heater ratio is missing; the sensor may still measure NOx.· Lost messageLost messageCheck soonCauses
- Sensor control unit sending a corrupted heater ratio
- Weak heater circuit in the sensor
- Heater controller inside the sensor drawing abnormal current
Checks
- 1Read the heater ratio on live data
- 2Check the sensor supply voltage
- 3Check for after-market wiring splices on the exhaust CAN branch
- 4Measure the heater current in the tool and compare it with a good sensor
- 5Observe how the heater ratio changes in the first minute after start and note whether it ever settles.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB U059E-29Upstream NOx sensor CAN bus error (code 29)
The upstream NOx sensor (the one ahead of the SCR catalyst) has a CAN bus error listed under suffix 29 and the source gives no further signal name; treat it as a general loss or corruption of the sensor's messages. The sensor drops out of the data list for periods and then returns.· Lost messageLost messageCheck soonCauses
- CAN wiring to the sensor damaged
- Sensor control unit failure
- Faulty splice on the exhaust CAN branch
Checks
- 1Check the CAN wires to the sensor and the terminating resistors
- 2Check the sensor supply and earth
- 3Monitor the sensor message on a CAN logger and look for gaps in its normal repeat time
- 4Look for a tape-and-crimp splice in the branch and test it for resistance
- 5Wiggle test the whole sensor branch from the junction to the sensor with a data log running, and mark the position where data breaks.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB U059F-29Downstream NOx sensor CAN error (code 29)
The downstream NOx sensor (the one after the SCR catalyst) has a CAN bus error listed under suffix 29 and the source gives no further signal name; treat it as a general loss or corruption of the sensor's messages. The sensor drops out of the data list for periods and then returns.· Lost messageLost messageCheck soonCauses
- CAN wiring to the sensor damaged
- Sensor control unit failure
- Faulty splice on the exhaust CAN branch
Checks
- 1Check the CAN wires to the sensor and the terminating resistors
- 2Check the sensor supply and earth
- 3Check the CAN wiring colours at the sensor against the wiring diagram
- 4Look for a tape-and-crimp splice in the branch and test it for resistance
- 5Wiggle test the whole sensor branch from the junction to the sensor with a data log running, and mark the position where data breaks.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB U059E-62Upstream NOx sensor NH3 level CAN error
The upstream NOx sensor (the one ahead of the SCR catalyst) sends an NH3 (ammonia) level signal that arrives with an error, so the controller cannot use the ammonia reading. Only the ammonia figure is missing; NOx and oxygen may still show.· Lost messageLost messageCheck soonCauses
- Sensor control unit sending a corrupted ammonia value
- CAN noise at the sensor connector
- NH3 channel in the sensor failing while NOx channel still works
Checks
- 1Read the NH3 value from the aftertreatment tool
- 2Check the sensor connector and shield
- 3Check the 120 ohm termination at both bus ends with the machine powered down
- 4Compare the NH3 reading with the dosing state: NH3 should rise after heavy dosing
- 5Dose heavily for a minute under load, then look at whether the ammonia figure changes at all.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB U059F-62Downstream NOx sensor NH3 level error
The downstream NOx sensor (the one after the SCR catalyst) sends an NH3 (ammonia) level signal that arrives with an error, so the controller cannot use the ammonia reading. Only the ammonia figure is missing; NOx and oxygen may still show.· OtherOtherCheck soonCauses
- Sensor control unit sending a corrupted ammonia value
- CAN noise at the sensor connector
- NH3 channel in the sensor failing while NOx channel still works
Checks
- 1Read the NH3 value from the aftertreatment tool
- 2Check the sensor connector and shield
- 3Check for chafing where the sensor lead passes an exhaust bracket
- 4Compare the NH3 reading with the dosing state: NH3 should rise after heavy dosing
- 5Dose heavily for a minute under load, then look at whether the ammonia figure changes at all.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB U059F-81Downstream NOx sensor CAN error (code 81)
The downstream NOx sensor (the one after the SCR catalyst) has a CAN error listed under suffix 81, a message error on the sensor's frames. Values from this sensor arrive late or jump between readings.· Lost messageLost messageCheck soonCauses
- Intermittent CAN connection at the sensor
- Corrupted frames from the sensor control unit
- Ground offset between the sensor control unit and the controller
Checks
- 1Check the sensor plug and CAN pins
- 2Read the sensor's own diagnostic status
- 3Monitor the sensor message on a CAN logger and look for gaps in its normal repeat time
- 4Measure the voltage difference between the sensor earth and the controller earth while running
- 5Compare how long frames take to arrive with the sensor on a different test harness lead if one is available.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB U059E-84Upstream NOx sensor power signal CAN error
The upstream NOx sensor (the one ahead of the SCR catalyst) sends a power signal over CAN that arrives with an error, which is the sensor's own supply status. The tool shows no sensor supply status while the sensor may still work.· Lost messageLost messageCheck soonCauses
- Sensor supply voltage unstable
- Poor earth at the sensor plug
- Sensor supply dipping when the heater switches on
Checks
- 1Measure the sensor supply while the engine runs
- 2Check the earth connection of the sensor
- 3Check the sensor control unit earth and supply under cranking load
- 4Log the sensor supply voltage while the heater cycles and look for drops
- 5Switch on the heated sensor load and watch the supply value report in the tool.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB U059F-84Downstream NOx sensor power signal CAN error
The downstream NOx sensor (the one after the SCR catalyst) sends a power signal over CAN that arrives with an error, which is the sensor's own supply status. The tool shows no sensor supply status while the sensor may still work.· Lost messageLost messageCheck soonCauses
- Sensor supply voltage unstable
- Poor earth at the sensor plug
- Sensor supply dipping when the heater switches on
Checks
- 1Measure the sensor supply while the engine runs
- 2Check the earth connection of the sensor
- 3Check the 120 ohm termination at both bus ends with the machine powered down
- 4Log the sensor supply voltage while the heater cycles and look for drops
- 5Switch on the heated sensor load and watch the supply value report in the tool.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB U059E-86CAN bus message error from upstream NOx sensor
The upstream NOx sensor (the one ahead of the SCR catalyst) has a CAN message error: the frame arrives but the content fails its check. Values from this sensor flicker between valid and invalid.· Lost messageLost messageCheck soonCauses
- Corrupted frames from the sensor control unit
- Poor CAN connection
- Frame counter or checksum errors from a failing sensor control unit
Checks
- 1Check the CAN pins and shield at the sensor plug
- 2Read the sensor's diagnostic status
- 3Look for water in the sensor connector after pressure washing
- 4Swap in a known good sensor if available and see whether the errors stop
- 5Check that the machine has the latest controller software, since frame definitions change between versions.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB U059F-86Downstream NOx sensor CAN bus error
The downstream NOx sensor (the one after the SCR catalyst) has a CAN message error: the frame arrives but the content fails its check. Values from this sensor flicker between valid and invalid.· Lost messageLost messageCheck soonCauses
- Corrupted frames from the sensor control unit
- Poor CAN connection
- Frame counter or checksum errors from a failing sensor control unit
Checks
- 1Check the CAN pins and shield at the sensor plug
- 2Read the sensor's diagnostic status
- 3Check the sensor control unit earth and supply under cranking load
- 4Swap in a known good sensor if available and see whether the errors stop
- 5Check that the machine has the latest controller software, since frame definitions change between versions.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB U059E-87Upstream NOx sensor CAN bus off error
The upstream NOx sensor (the one ahead of the SCR catalyst) went bus-off: the sensor module stopped talking on the CAN bus after too many errors. The whole sensor drops off the bus and the controller sees silence.· Lost messageLost messageCheck soonCauses
- Short between CAN high and low near the sensor
- Sensor module driving the bus into error
- CAN driver of the sensor shorted internally and holding the bus down
Checks
- 1Measure CAN high and low at the sensor plug
- 2Unplug the sensor and see whether the bus recovers
- 3Check that the CAN shield is earthed at the right end only
- 4Disconnect the sensor and measure CAN high to low resistance; it should return to the bus value
- 5Count bus-off events in the tool's history, which shows how often it happens.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB U059F-87CAN bus off error from downstream NOx sensor
The downstream NOx sensor (the one after the SCR catalyst) went bus-off: the sensor module stopped talking on the CAN bus after too many errors. The whole sensor drops off the bus and the controller sees silence.· Lost messageLost messageCheck soonCauses
- Short between CAN high and low near the sensor
- Sensor module driving the bus into error
- CAN driver of the sensor shorted internally and holding the bus down
Checks
- 1Measure CAN high and low at the sensor plug
- 2Unplug the sensor and see whether the bus recovers
- 3Look for water in the sensor connector after pressure washing
- 4Disconnect the sensor and measure CAN high to low resistance; it should return to the bus value
- 5Count bus-off events in the tool's history, which shows how often it happens.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB U059E-93Upstream NOx sensor CAN message error
The upstream NOx sensor (the one ahead of the SCR catalyst) has a CAN message error listed under suffix 93, a frame that fails its validity check. Values from this sensor arrive late or jump between readings.· Lost messageLost messageCheck soonCauses
- Intermittent CAN connection at the sensor
- Corrupted frames from the sensor control unit
- Marginal CAN voltage levels because of corroded pins
Checks
- 1Check the sensor plug and CAN pins
- 2Read the sensor's own diagnostic status
- 3Compare the sensor CAN address and software number with the parts book
- 4Compare CAN high and low voltages at the sensor with the rest of the bus
- 5Hold the key in the run position for a minute without starting and note whether the fault occurs with the engine off.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB U059F-93Downstream NOx sensor CAN bus message error
The downstream NOx sensor (the one after the SCR catalyst) has a CAN message error listed under suffix 93, a frame that fails its validity check. Values from this sensor arrive late or jump between readings.· Lost messageLost messageCheck soonCauses
- Intermittent CAN connection at the sensor
- Corrupted frames from the sensor control unit
- Marginal CAN voltage levels because of corroded pins
Checks
- 1Check the sensor plug and CAN pins
- 2Read the sensor's own diagnostic status
- 3Check that the CAN shield is earthed at the right end only
- 4Compare CAN high and low voltages at the sensor with the rest of the bus
- 5Hold the key in the run position for a minute without starting and note whether the fault occurs with the engine off.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB U059E-94CAN bus message error for O2 level from upstream NOx sensor
The upstream NOx sensor (the one ahead of the SCR catalyst) sends the oxygen (O2) level signal with a CAN message error, so the controller cannot use the oxygen value that goes with the NOx reading. Only the oxygen figure is missing; NOx may still show.· Lost messageLost messageCheck soonCauses
- Sensor control unit sending a corrupted oxygen value
- Contaminated sensor element
- Oxygen channel degraded by sulphur or soot contamination
Checks
- 1Read the O2 value from the aftertreatment tool
- 2Check the sensor connector and its CAN wiring
- 3Disconnect the other NOx sensor and see whether the fault changes, to rule out the bus
- 4Look at the oxygen value at idle in clean air conditions and compare it with the typical value in the manual
- 5Compare the oxygen reading to the ambient level (about one fifth oxygen) on a cold key-on.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB U059F-94CAN bus message error for O2 level from downstream NOx sensor
The downstream NOx sensor (the one after the SCR catalyst) sends the oxygen (O2) level signal with a CAN message error, so the controller cannot use the oxygen value that goes with the NOx reading. Only the oxygen figure is missing; NOx may still show.· Lost messageLost messageCheck soonCauses
- Sensor control unit sending a corrupted oxygen value
- Contaminated sensor element
- Oxygen channel degraded by sulphur or soot contamination
Checks
- 1Read the O2 value from the aftertreatment tool
- 2Check the sensor connector and its CAN wiring
- 3Compare the sensor CAN address and software number with the parts book
- 4Look at the oxygen value at idle in clean air conditions and compare it with the typical value in the manual
- 5Compare the oxygen reading to the ambient level (about one fifth oxygen) on a cold key-on.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB U059E-97Upstream NOx sensor CAN bus error (code 97)
The upstream NOx sensor (the one ahead of the SCR catalyst) has a CAN bus message error listed under suffix 97, a frame that fails its validity check. Values from this sensor arrive late or jump between readings.· Lost messageLost messageCheck soonCauses
- Intermittent CAN connection at the sensor
- Corrupted frames from the sensor control unit
- Shielded CAN cable with a broken drain wire
Checks
- 1Check the sensor plug and CAN pins
- 2Read the sensor's own diagnostic status
- 3Check for after-market wiring splices on the exhaust CAN branch
- 4Check the drain wire continuity to the earth point
- 5Photograph the plug pins before and after cleaning to prove the contact was bad.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB U059F-97Downstream NOx sensor CAN bus message error (code 97)
The downstream NOx sensor (the one after the SCR catalyst) has a CAN bus message error listed under suffix 97, a frame that fails its validity check. Values from this sensor arrive late or jump between readings.· Lost messageLost messageCheck soonCauses
- Intermittent CAN connection at the sensor
- Corrupted frames from the sensor control unit
- Shielded CAN cable with a broken drain wire
Checks
- 1Check the sensor plug and CAN pins
- 2Read the sensor's own diagnostic status
- 3Disconnect the other NOx sensor and see whether the fault changes, to rule out the bus
- 4Check the drain wire continuity to the earth point
- 5Photograph the plug pins before and after cleaning to prove the contact was bad.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Shared checks
Checks, in order
- 1Check the CAN high and low wires to the NOx sensor CAN data for opens, shorts and water
- 2Measure the supply and earth at the NOx sensor CAN data connector with the key on
- 3Check the CAN bus for other faults and measure the termination resistance
- 4Inspect the NOx sensor CAN data connector for water, corrosion and pushed-back pins
Causes
- CAN wiring fault
- Sensor fault
- Bus fault
- Sensor power fault
Most codes here: lost message (24 of 25)
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
When to stop
You'll notice: An SCR warning may show.
Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.