EF Logo

JCB · Communication (CAN / telematics)

JCB CAN bus, module communication and LiveLink telematics fault codes

These codes report a general CAN bus fault such as a bus-off state or timeout, lost communication with the EGR, turbo or other control modules, or an ECU that is not bound to the machine. The LiveLink unit is JCB's telematics box with a modem, GPS and SIM.

More about these parts

These codes report problems with its power, antenna, SIM or network.

FaultCheckU0002JCB · CAN bus, module communication and LiveLink telematics
Code shows hereFAULTU0002

Where this code shows

Switch the key on and note any warning lamp or fault icon on the cluster.

What do these codes mean?

JCB codes U0002 to U2106 are all about the cAN bus, module communication and LiveLink telematics. The most common failure type is lost message (12 of 27); none needs an immediate stop. Start with this check: check the CAN high and low wiring for opens, shorts and water.

How urgent are they?

None of the 27 codes here means stop now; 16 can wait until the shift ends, but find the cause before the next one; 11 are information only.

  • Check soon16
  • Info11

What should I check first?

Check the CAN high and low wiring for opens, shorts and water

Shared checks

27 of 27

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • JCB U0002ISO-CAN bus fault

    A controller reports a general fault on the ISO CAN bus.· Lost message
    Check soon

    Causes

    • Open or shorted CAN high or CAN low wire
    • Missing or faulty terminating resistor at either end of the bus
    • A module pulling the bus down after an internal failure

    Checks

    1. 1Measure resistance between CAN high and CAN low with the system powered down and compare it with the combined terminator value
    2. 2Unplug modules one at a time to find one that drags the bus down
    3. 3Inspect connectors and splices on the CAN trunk for water or corrosion
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • JCB U010ALost communication with EGR control module A

    The engine ECU lost communication with the EGR control module.· Lost message
    Check soon

    Causes

    • EGR control module without supply or earth
    • CAN wiring to the EGR module open or loose

    Checks

    1. 1Check the EGR module supply, earth and connector
    2. 2Check CAN continuity to the module
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • JCB U010CLost communication with turbocharger control module A

    The engine ECU lost communication with the turbocharger control module that drives the variable-geometry actuator.· Lost message
    Check soon

    Causes

    • Turbocharger control module without power
    • CAN link to the module damaged or loose
    • Module failed internally

    Checks

    1. 1Check the turbocharger actuator module supply, earth and connector
    2. 2Check CAN continuity and the termination between the module and the engine ECU
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • JCB U0029-87CAN bus communication failure at 250 kbps

    The machine's CAN network, which runs at 250 kbps, has lost communication.· Lost message
    Check soon

    Causes

    • Wiring fault on the 250 kbps CAN trunk
    • A module on the bus not powered or stuck in reset

    Checks

    1. 1Check CAN high and low continuity and the termination resistors
    2. 2Check that each module on the bus has power and earth
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • JCB U0029-88CAN bus communication failure at 250 kbps (code 88)

    The same 250 kbps CAN communication failure as U0029-87, recorded under suffix 88.· Lost message
    Check soon

    Causes

    • Wiring fault on the CAN trunk
    • A module on the bus not powered or in reset

    Checks

    1. 1Compare which controllers report the fault under -87 and -88 and look for the one they have in common
    2. 2Inspect CAN connectors for water or corrosion
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • JCB U040BCAN communication error, EGR overtemperature

    A CAN communication error was raised together with an EGR overtemperature condition.· Lost message
    Check soon

    Causes

    • CAN message about EGR temperature not received
    • Overheating EGR cooler genuinely reporting high temperature

    Checks

    1. 1Read the EGR temperature on live data to see whether the value is real
    2. 2Check CAN wiring between the EGR module and the engine ECU
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • JCB U040DInvalid data from turbocharger control module A

    The turbocharger control module sent data that the engine ECU judged invalid.· Other
    Check soon

    Causes

    • Turbocharger control module sending corrupted data
    • Intermittent CAN fault on the module link

    Checks

    1. 1Check the turbocharger actuator supply voltage and its connector
    2. 2Read the turbo module's own fault list for internal faults
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JCB U040FEngine rating mismatch

    The engine rating stored in the engine ECU does not match what another controller expects.· Other
    Check soon

    Causes

    • Wrong software or rating file loaded in one of the controllers
    • A replaced controller not programmed for this machine

    Checks

    1. 1Compare the engine rating and software versions in each controller with the machine's data plate or service tool
    2. 2Reprogram the replaced controller with the right file
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JCB U0073Control module communication bus A off

    The control module communication bus A has gone off: a controller disconnected itself from the bus after repeated errors, so other controllers stop hearing from it.· Open circuit
    Check soon

    Causes

    • Short between CAN high and CAN low
    • Bus A wiring open at a connector
    • Faulty module sending constant errors

    Checks

    1. 1Measure the CAN voltages with the key on and look for a bus stuck at one level
    2. 2Disconnect modules one at a time and watch whether the bus recovers
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • JCB U0101CAN timeout fault

    A controller waited for a CAN message from another controller and nothing arrived in time.· Lost message
    Check soon

    Causes

    • Sending controller without power or earth
    • CAN wiring break or loose connector

    Checks

    1. 1Check fuses and supply to the controller that should be sending the message
    2. 2Wiggle the CAN connectors while watching whether communication returns
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • JCB U0110Inducement BAM time-out fault

    The inducement message from the aftertreatment controller to the engine ECU timed out, so the engine cannot be told the state of inducement and the derate function may misbehave.· Lost message
    Check soon

    Causes

    • CAN link between the aftertreatment controller and the engine ECU interrupted
    • Aftertreatment controller reset or without power

    Checks

    1. 1Check the aftertreatment controller supply and CAN wiring
    2. 2Compare the message timing in the diagnostic tool if it can show the bus traffic
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • JCB U190ALiveLink SIM card failure

    LiveLink SIM card failure.· Other
    Info

    Causes

    • LiveLink SIM card failure or its wiring faulty
    • Connector corrosion or a loose pin

    Checks

    1. 1Read the live data for the liveLink SIM card failure and look for a value that is stuck or implausible
    2. 2Check the liveLink SIM card failure connector and wiring for damage
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JCB U190BLiveLink loss of communication with GSM module

    LiveLink loss of communication with GSM module.· Other
    Info

    Causes

    • CAN wiring open, shorted or wet at a connector
    • The sending module not powered, reset or faulty

    Checks

    1. 1Check the CAN high and low wiring and the 120 ohm termination
    2. 2Check that the sending module has power, earth and no active faults of its own
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JCB U190CLiveLink GSM network registration failure

    LiveLink GSM network registration failure.· Lost message
    Info

    Causes

    • LiveLink GSM network registration failure or its wiring faulty
    • Connector corrosion or a loose pin

    Checks

    1. 1Read the live data for the liveLink GSM network registration failure and look for a value that is stuck or implausible
    2. 2Check the liveLink GSM network registration failure connector and wiring for damage
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • JCB U0410VNT communication fault

    Communication with the variable-nozzle turbocharger (VNT) actuator failed.· Lost message
    Check soon

    Causes

    • VNT actuator connector or wiring damaged
    • Actuator electronics failed

    Checks

    1. 1Check the VNT actuator connector and wiring
    2. 2Run the actuator test with the diagnostic tool
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • JCB U1100Communication failure between systems

    A controller reported a communication failure between two systems on the machine, without naming which.· Other
    Check soon

    Causes

    • Wiring problem between the two systems
    • One of the two controllers not powered

    Checks

    1. 1Read the fault lists from all controllers to find which two lost contact
    2. 2Check power and earth to each of them
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JCB U1300ECU binding fault

    The engine ECU is not bound to the machine controller, a security pairing that must match after a replacement.· Other
    Check soon

    Causes

    • Engine ECU or machine controller replaced and not paired
    • Pairing data corrupted

    Checks

    1. 1Perform the ECU binding or matching procedure with the service tool
    2. 2Check you are binding the correct controllers for this machine
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JCB U1800ECU binding fault

    The same ECU binding fault as U1300, recorded under a different code number.· Other
    Check soon

    Causes

    • ECU or machine controller replaced and not paired
    • Binding data lost after reprogramming

    Checks

    1. 1Repeat the binding procedure and read both codes again
    2. 2Confirm the part numbers of both controllers match the machine
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JCB U1900LiveLink vehicle battery voltage below normal

    LiveLink vehicle battery voltage below normal.· Shorted low
    Info

    Causes

    • LiveLink vehicle battery voltage below normal signal pulled low by a short to ground or an open supply
    • Sensor or part failed giving a low reading

    Checks

    1. 1Read the liveLink vehicle battery voltage below normal value on live data and compare it with the expected value
    2. 2Unplug the liveLink vehicle battery voltage below normal and check the signal wire for a short to ground and the supply for 5 V
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • JCB U1901LiveLink ECU internal voltage below normal

    LiveLink ECU internal voltage below normal.· Shorted low
    Info

    Causes

    • LiveLink ECU internal voltage below normal signal pulled low by a short to ground or an open supply
    • Sensor or part failed giving a low reading

    Checks

    1. 1Read the liveLink ECU internal voltage below normal value on live data and compare it with the expected value
    2. 2Unplug the liveLink ECU internal voltage below normal and check the signal wire for a short to ground and the supply for 5 V
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • JCB U1904LiveLink ECU above temperature threshold

    LiveLink ECU above temperature threshold.· Other
    Info

    Causes

    • LiveLink ECU above temperature threshold signal pulled high by a short to the 5 V reference or supply
    • Sensor or part failed giving a high reading

    Checks

    1. 1Read the liveLink ECU above temperature threshold value on live data and compare it with the expected value
    2. 2Unplug the liveLink ECU above temperature threshold and check the signal wire for a short to 5 V or battery
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JCB U1905LiveLink ECU below temperature threshold

    LiveLink ECU below temperature threshold.· Other
    Info

    Causes

    • LiveLink ECU below temperature threshold signal pulled low by a short to ground or an open supply
    • Sensor or part failed giving a low reading

    Checks

    1. 1Read the liveLink ECU below temperature threshold value on live data and compare it with the expected value
    2. 2Unplug the liveLink ECU below temperature threshold and check the signal wire for a short to ground and the supply for 5 V
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JCB U1906LiveLink accelerometer internal failure

    LiveLink accelerometer internal failure.· Other
    Info

    Causes

    • LiveLink accelerometer internal failure or its wiring faulty
    • Connector corrosion or a loose pin

    Checks

    1. 1Read the live data for the liveLink accelerometer internal failure and look for a value that is stuck or implausible
    2. 2Check the liveLink accelerometer internal failure connector and wiring for damage
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JCB U1907LiveLink telematics modem jammed

    LiveLink telematics modem jammed.· Other
    Info

    Causes

    • LiveLink telematics modem jammed or its wiring faulty
    • Connector corrosion or a loose pin

    Checks

    1. 1Read the live data for the liveLink telematics modem jammed and look for a value that is stuck or implausible
    2. 2Check the liveLink telematics modem jammed connector and wiring for damage
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JCB U1908LiveLink GPS antenna malfunction

    LiveLink GPS antenna malfunction.· Other
    Info

    Causes

    • LiveLink GPS antenna malfunction or its wiring faulty
    • Connector corrosion or a loose pin

    Checks

    1. 1Read the live data for the liveLink GPS antenna malfunction and look for a value that is stuck or implausible
    2. 2Check the liveLink GPS antenna malfunction connector and wiring for damage
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JCB U1909LiveLink no communication with GPS module

    LiveLink no communication with GPS module.· Lost message
    Info

    Causes

    • CAN wiring open, shorted or wet at a connector
    • The sending module not powered, reset or faulty

    Checks

    1. 1Check the CAN high and low wiring and the 120 ohm termination
    2. 2Check that the sending module has power, earth and no active faults of its own
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • JCB U2106CAN timeout fault

    A controller timed out waiting for a CAN message, the same condition as U0101 but reported from another module.· Lost message
    Check soon

    Causes

    • Controller that sends the message not powered or reset
    • CAN wiring or connector fault

    Checks

    1. 1Find out which controller reports the code and which one it expects to hear from
    2. 2Check that controller's supply, earth and CAN connector
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

Shared checks

Checks, in order

  1. 1Check the CAN high and low wiring for opens, shorts and water
  2. 2Check the antenna cable and connector (on the LiveLink telematics unit, with the diagnostic tool and a multimeter)
  3. 3Measure the bus resistance with power off, it should show the termination
  4. 4Check the SIM card is seated and active (on the LiveLink telematics unit, with the diagnostic tool and a multimeter)
  5. 5Unplug nodes one at a time to find a faulty one
  6. 6Check the supply voltage at the LiveLink unit (on the LiveLink telematics unit, with the diagnostic tool and a multimeter)
  7. 7Run the ECU binding procedure after any ECU change

Causes

  • CAN wiring damaged or water in connectors
  • Antenna or cable fault
  • Missing or wrong termination
  • SIM card or network problem

Most common here: lost message (12 of 27)

Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

When to stop

You'll notice: Several controllers may report faults at once, some functions may be limited, and the engine may derate.

Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.