JCB · Communication (CAN / telematics)
JCB Engine ECU CAN messages fault codes
Other controllers receive engine speed, temperature, pressure and EGR data from the engine ECU over CAN, and the aftertreatment unit receives boost, temperature and operating mode data. These codes say a message is missing, invalid, late or the override switch message is wrong.
Where this code shows
Switch the key on and note any warning lamp or fault icon on the cluster.
What do these codes mean?
JCB codes P0070-81 to P3423-87 are all about the engine ECU CAN messages. Most are lost message faults; none needs an immediate stop. Start with this check: check the CAN wiring and the 120 ohm termination.
How urgent are they?
None of the 22 codes here means stop now; all 22 can wait until the shift ends, but find the cause before the next one.
- Check soon22
What should I check first?
Check the CAN wiring and the 120 ohm termination
Shared checks22 of 22
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
JCB P0070-81Engine ECU CAN bus message error
Frames from the engine ECU reach this controller but they carry a message error, so the data cannot be trusted. The bus is alive; the content is bad.· Lost messageLost messageCheck soonCauses
- Electrical noise or a poor CAN connection corrupting frames
- Engine ECU sending badly formed frames after a software fault
Checks
- 1Check CAN connector pins and shield earth near the engine ECU
- 2Read the engine ECU for internal or software faults
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB P0070-87Missing message from engine ECU
The engine ECU's messages stopped arriving at this controller altogether. The receiving controller has lost its source of engine data.· Lost messageLost messageCheck soonCauses
- Engine ECU without power, in reset or off the bus
- CAN wire open between the two controllers
Checks
- 1Check the engine ECU power relay, fuses and earths
- 2Check continuity of CAN high and low between the controllers
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB U0105-87CAN bus message error for fuel quantity from engine ECU
The fuel quantity message from the engine ECU is missing or corrupted. Controllers that use fuel quantity, for example for load estimation, lose that input.· Lost messageLost messageCheck soonCauses
- Engine ECU not sending fuel quantity
- CAN link interrupted
Checks
- 1Check that the engine ECU is sending fuel quantity with the diagnostic tool
- 2Check CAN wiring and termination
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB P0321-87Missing engine speed CAN message
The engine speed message from the engine ECU is missing. The controller that needs engine rpm, such as the cluster or the hydraulic controller, receives nothing and may show zero or limit functions.· Lost messageLost messageCheck soonCauses
- Engine ECU not transmitting engine speed
- Break in the CAN link that carries engine speed
Checks
- 1Compare the rpm shown in the diagnostic tool from the engine ECU with the rpm in the receiving controller
- 2Test the CAN link while the engine is running and watching the rpm value
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB U0401-61CAN bus message error for modelled NOx from engine ECU
The modelled NOx value from the engine ECU arrives with a message error. The aftertreatment controller relies on this model, for example for dosing.· Lost messageLost messageCheck soonCauses
- Engine ECU sending a corrupted modelled NOx frame
- CAN noise
Checks
- 1Read the modelled NOx value in the engine ECU
- 2Check CAN connectors and shield
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB U0401-81CAN bus message error from engine ECU
A message from the engine ECU has an error: the frame arrives but fails its validity check. The receiving controller cannot use the data.· Lost messageLost messageCheck soonCauses
- Poor CAN connection corrupting frames
- Engine ECU software fault
Checks
- 1Check the CAN pins at the engine ECU and the receiver
- 2Read the engine ECU for software or internal faults
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB U0401-86Invalid CAN signal from engine ECU
A signal in the engine ECU's CAN message is invalid: the value is outside what the message definition allows.· Lost messageLost messageCheck soonCauses
- Engine ECU sending an out-of-range value
- Software mismatch between controllers
Checks
- 1Compare the same signal in the engine ECU and in the receiving controller
- 2Compare software versions
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB U0401-87Invalid data from engine control module, missing message
The engine control module's message is missing at the receiving controller, so invalid or no data arrives for the signals it carries.· Lost messageLost messageCheck soonCauses
- Engine ECU off the bus or not powered
- CAN wire break
Checks
- 1Check the engine ECU supply, earth and the power relay
- 2Check CAN continuity to the engine ECU
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB P1400-00Erroneous signal from override switch
The signal from the engine override switch is judged erroneous. The switch input is present but its value does not make sense, for example both states at once.· OtherOtherCheck soonCauses
- Override switch contacts faulty or stuck
- Wiring fault on the switch input
Checks
- 1Operate the override switch and watch its state change on live data
- 2Check the switch plug and wiring for water or damaged pins
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB P1401-00CAN bus message error from override switch
The CAN message that carries the override switch state has an error. The message arrives but fails the check on its content.· Lost messageLost messageCheck soonCauses
- Controller that reads the switch sending bad frames
- Connector or wiring fault on the CAN link
Checks
- 1Check the connector of the module that reads the override switch
- 2Read that module for its own faults
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB P1402-00CAN bus off error from override switch
The module that reads the override switch has gone bus-off: it stopped talking on CAN after too many errors, so the override request cannot reach the engine.· Lost messageLost messageCheck soonCauses
- Short on the CAN wiring near the switch module
- Switch module faulty or without supply
Checks
- 1Check supply and earth of the switch module
- 2Measure CAN high and low for a short or an open
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB P1509CAN bus communication error with TSC
Communication with the torque speed control (TSC) message failed on CAN. The machine controller cannot hand a torque or speed request to the engine ECU.· Lost messageLost messageCheck soonCauses
- CAN wiring between the machine controller and the engine ECU interrupted
- Engine ECU not accepting TSC messages after a software change
Checks
- 1Check CAN continuity between the two controllers
- 2Confirm the engine ECU software and its TSC configuration match the machine
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB P2413-81CAN bus message error for EGR faults from engine
The engine ECU sent an EGR fault message that arrives corrupted. The aftertreatment or machine controller cannot rely on the EGR status it receives.· Lost messageLost messageCheck soonCauses
- CAN noise or a poor connection on the EGR message path
- Engine ECU sending a malformed EGR frame
Checks
- 1Check the connectors and shield on the CAN link
- 2Read the EGR status directly from the engine ECU and compare with what the receiving controller shows
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB P2413-86CAN bus message error from engine ECU (EGR)
The EGR fault message from the engine ECU is invalid: the signal value is outside what the message format allows.· Lost messageLost messageCheck soonCauses
- Engine ECU reporting an invalid EGR value
- Software mismatch between controllers
Checks
- 1Read the engine ECU's EGR data and fault list
- 2Compare controller software versions
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB P2413-87CAN bus off for EGR faults from engine ECU
The module carrying the EGR fault message from the engine ECU went bus-off, so the EGR status cannot be received.· Lost messageLost messageCheck soonCauses
- Short or open on the CAN pair
- Engine ECU or the receiving module driving the bus into error
Checks
- 1Measure CAN high and low voltage and look for a stuck bus
- 2Disconnect modules one at a time to find one pulling the bus down
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB P2502-87Missing engine ECU power management message
The engine ECU's power management message is missing. The controller that depends on it for charging or power-down decisions has lost that information.· OtherOtherCheck soonCauses
- Engine ECU not sending the power management frame
- CAN fault on the link between engine ECU and the power-management consumer
Checks
- 1Check the engine ECU supply and the CAN link
- 2Read the power management status from the engine ECU directly
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB P3414-87Erroneous signal for engine boost pressure
The boost pressure value the aftertreatment controller receives from the engine ECU is erroneous. The signal arrives but is outside the plausible range.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Engine ECU sending a wrong boost value, possibly from a failed boost sensor
- CAN data error on the link
Checks
- 1Compare the boost pressure shown by the engine ECU with the one in the aftertreatment controller
- 2Check the engine boost sensor and its wiring
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
JCB P3415-87Data length error for IC1 frame
The IC1 frame, which carries intake manifold data from the engine ECU, has the wrong data length. The frame format is off and the receiver rejects it.· OtherOtherCheck soonCauses
- Software or configuration mismatch between the engine ECU and the receiver
- Frame corrupted on the bus
Checks
- 1Compare the software versions and CAN configuration of both controllers
- 2Check the CAN wiring for noise
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB P3416-87Time out error for IC1 frame
The IC1 frame from the engine ECU did not arrive within its time window. The receiver stops getting intake manifold data until frames resume.· Lost messageLost messageCheck soonCauses
- Engine ECU not sending IC1
- CAN link interrupted
Checks
- 1Check that the engine ECU is sending IC1 using the bus monitor in the diagnostic tool
- 2Check CAN wiring and termination
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB P3417-87Erroneous signal for intake manifold temperature
The intake manifold temperature value received from the engine ECU is erroneous. The data does not match what the receiver expects for that sensor.· OtherOtherCheck soonCauses
- Engine ECU passing a wrong intake manifold temperature, for example from a failed sensor
- CAN data error
Checks
- 1Read the manifold temperature sensor value in the engine ECU
- 2Check the sensor and its wiring
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB P3418-87Erroneous signal for operating mode request
The operating mode request from the engine ECU is erroneous. The aftertreatment controller cannot work out which mode the engine is asking for.· OtherOtherCheck soonCauses
- Engine ECU sending an invalid operating mode
- Mismatch in software between controllers
Checks
- 1Read the engine operating mode in the diagnostic tool
- 2Compare software versions of the two controllers
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB P3423-87Erroneous signal for engine exhaust gas temperature
The exhaust gas temperature value from the engine ECU is erroneous at the receiver. The reading is outside what the aftertreatment controller can accept.· Lost messageLost messageCheck soonCauses
- Engine ECU sending an implausible exhaust gas temperature
- CAN corruption
Checks
- 1Compare the exhaust temperature in the engine ECU with that in the aftertreatment controller
- 2Check the exhaust temperature sensor wiring
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Shared checks
Checks, in order
- 1Check the CAN wiring and the 120 ohm termination
- 2Check that the engine ECU is powered and has no active faults
- 3Look for other nodes that drop off the bus (on the engine CAN messages, with the diagnostic tool and a multimeter)
- 4Check software versions match (on the engine CAN messages, with the diagnostic tool and a multimeter)
Causes
- CAN wiring open or shorted
- Engine ECU not sending the message
- Bus overloaded or a node faulty
- Software mismatch between units
Most codes here: lost message (16 of 22)
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
When to stop
You'll notice: Gauges may read wrong, some functions may be limited, and a check lamp is on.
Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
- Partao JCB fault code list, page 4 (code table)
- Partao JCB fault code list, page 16 (code table)
- Partao JCB fault code list, page 7 (code table)
- Partao JCB fault code list, page 9 (code table)
- Partao JCB fault code list, page 10 (code table)
- Partao JCB fault code list, page 13 (code table)
- Partao JCB fault code list, page 14 (code table)
- Partao JCB fault code list, page 15 (code table)
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.