DOC inlet/outlet pressure implausible

What does SPN 3251 FMI 21 mean?

The pressure readings across the DOC and DPF do not agree with each other. The ECM suspects a sensor, hose or filter problem and may block regeneration. Urgency: check soon - the machine may derate or limit a function. Check first: check each hose runs to the correct tap and sensor port.

FaultCheckSPN 3251FMI 21J1939 engine ECU

Can I keep running with it?

Check soon

The machine may derate or limit a function. Find the cause before the next shift.

What should I check first?

Check each hose runs to the correct tap and sensor port

Then 4 more checks
Plug the service tool in hereDiagnosticport, 9-pin

Where to read it

Connect a J1939-capable scan tool to the 9-pin diagnostic port.

Checks

0 of 5 done

Causes

  • Sensor hoses crossed or swapped at the taps
  • One of the pressure sensors drifting or failed
  • Exhaust leak between the two sensing points
  • Hose damaged by heat or abrasion

How it failed

You'll notice: The pressure readings across the DOC and DPF do not agree with each other, so the ECM suspects a sensor, hose or filter problem and may block regeneration and show the lamp.

Erratic or implausibleRead from FMI 21: data drifted low

The reading jumps, drifts or disagrees with the sensors around it.

allowed rangetime
The reading against the band the controller allows.
Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good result
A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

When to stop

Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.

Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Source

Detroit Diesel DD15 2017-2020 fault codes list (Diesel Laptops)

This list shows SPN 3251 with FMI 21. The guidance on this page is general, not taken from it.

Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.