Deutz · ECU hardware
Deutz Main and Secondary ECU link and hardware events fault codes
On engines with a Main and a Secondary controller the two exchange messages over a private CAN link and cross-check each other. These codes cover events on the Secondary ECU that make the Main ECU log a collective fault (battery voltage, CAN, monitoring, software reset, EEPROM, speed signal) and timeouts of the messages between the two controllers.
Where to read it
Read the active and stored faults with Deutz SerDia (or the machine maker's diagnostic tool) on the engine diagnostic plug.
What do these codes mean?
Deutz codes SPN 524038 FMI 9 to SPN 524243 FMI 11 are all about the main and Secondary ECU link and hardware events. Most are lost message faults; none needs an immediate stop. Start with this check: read the dataset and software versions of both controllers in SerDia and compare them.
How urgent are they?
None of the 20 codes here means stop now; all 20 can wait until the shift ends, but find the cause before the next one.
- Check soon20
What should I check first?
Read the dataset and software versions of both controllers in SerDia and compare them
Shared checks20 of 20
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
CAN Main Secondary13 codes
Deutz SPN 524038 FMI 9CAN Main Secondary: Abnormal update rate timeout
The EMR4 did not receive the CAN Main Secondary (on the CAN link between the two controllers of a twin-controller engine) within the expected time. The data comes from another control unit on the bus, so the fault sits in the bus, the sender or its supply rather than in an engine sensor. Deutz list: KWP code 1285, blink code 8-2-4. One cyclic message between the Main and the Secondary ECU is missing; the code number says which of the exchanged messages, and the pair of controllers cross-check less.· Lost messageLost messageCheck soonCauses
- CAN wire open, shorted or a connector loose on the path to the sender
- Sender not powered, in reset or switched off
Checks
- 1Check the supply and ground of the sending control unit with the key on
- 2Measure the bus resistance with the key off and look for a missing terminating resistor
- 3Look at the private CAN wires and plugs between the two controllers and watch the message status in SerDia.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Deutz SPN 524039 FMI 9CAN Main Secondary: Abnormal update rate timeout
Same fault as SPN 524038 FMI 9 for the CAN Main Secondary message. One cyclic message between the Main and the Secondary ECU is missing; the code number says which of the exchanged messages, and the pair of controllers cross-check less. Deutz list: KWP code 1286, blink code 8-2-5.· Lost messageLost messageCheck soonCauses
- CAN wire open, shorted or a connector loose on the path to the sender
- Sender not powered, in reset or switched off
Checks
- 1Look at the private CAN wires and plugs between the two controllers and watch the message status in SerDia.
- 2Check the supply and ground of the sending control unit with the key on
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Deutz SPN 524040 FMI 9CAN Main Secondary: Abnormal update rate timeout
Same fault as SPN 524038 FMI 9 for the CAN Main Secondary message. One cyclic message between the Main and the Secondary ECU is missing; the code number says which of the exchanged messages, and the pair of controllers cross-check less. Deutz list: KWP code 1287, blink code 8-2-6.· Lost messageLost messageCheck soonCauses
- CAN wire open, shorted or a connector loose on the path to the sender
- Sender not powered, in reset or switched off
Checks
- 1Look at the private CAN wires and plugs between the two controllers and watch the message status in SerDia.
- 2Check the supply and ground of the sending control unit with the key on
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Deutz SPN 524041 FMI 9CAN Main Secondary: Abnormal update rate timeout
Same fault as SPN 524038 FMI 9 for the CAN Main Secondary message. One cyclic message between the Main and the Secondary ECU is missing; the code number says which of the exchanged messages, and the pair of controllers cross-check less. Deutz list: KWP code 1288, blink code 8-2-7.· Lost messageLost messageCheck soonCauses
- CAN wire open, shorted or a connector loose on the path to the sender
- Sender not powered, in reset or switched off
Checks
- 1Look at the private CAN wires and plugs between the two controllers and watch the message status in SerDia.
- 2Check the supply and ground of the sending control unit with the key on
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Deutz SPN 524042 FMI 9CAN Main Secondary: Abnormal update rate timeout
Same fault as SPN 524038 FMI 9 for the CAN Main Secondary message. One cyclic message between the Main and the Secondary ECU is missing; the code number says which of the exchanged messages, and the pair of controllers cross-check less. Deutz list: KWP code 1289, blink code 8-2-8.· Lost messageLost messageCheck soonCauses
- CAN wire open, shorted or a connector loose on the path to the sender
- Sender not powered, in reset or switched off
Checks
- 1Look at the private CAN wires and plugs between the two controllers and watch the message status in SerDia.
- 2Check the supply and ground of the sending control unit with the key on
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Deutz SPN 524043 FMI 9CAN Main Secondary: Abnormal update rate timeout
Same fault as SPN 524038 FMI 9 for the CAN Main Secondary message. One cyclic message between the Main and the Secondary ECU is missing; the code number says which of the exchanged messages, and the pair of controllers cross-check less. Deutz list: KWP code 1290, blink code 8-2-9.· Lost messageLost messageCheck soonCauses
- CAN wire open, shorted or a connector loose on the path to the sender
- Sender not powered, in reset or switched off
Checks
- 1Look at the private CAN wires and plugs between the two controllers and watch the message status in SerDia.
- 2Check the supply and ground of the sending control unit with the key on
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Deutz SPN 524044 FMI 9CAN Main Secondary: Abnormal update rate timeout
Same fault as SPN 524038 FMI 9 for the CAN Main Secondary message. One cyclic message between the Main and the Secondary ECU is missing; the code number says which of the exchanged messages, and the pair of controllers cross-check less. Deutz list: KWP code 1482, blink code 1-8-8.· Lost messageLost messageCheck soonCauses
- CAN wire open, shorted or a connector loose on the path to the sender
- Sender not powered, in reset or switched off
Checks
- 1Look at the private CAN wires and plugs between the two controllers and watch the message status in SerDia.
- 2Check the supply and ground of the sending control unit with the key on
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Deutz SPN 524045 FMI 9CAN Main Secondary: Abnormal update rate timeout
Same fault as SPN 524038 FMI 9 for the CAN Main Secondary message. One cyclic message between the Main and the Secondary ECU is missing; the code number says which of the exchanged messages, and the pair of controllers cross-check less. Deutz list: KWP code 1291, blink code 8-3-1.· Lost messageLost messageCheck soonCauses
- CAN wire open, shorted or a connector loose on the path to the sender
- Sender not powered, in reset or switched off
Checks
- 1Look at the private CAN wires and plugs between the two controllers and watch the message status in SerDia.
- 2Check the supply and ground of the sending control unit with the key on
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Deutz SPN 524046 FMI 9CAN Main Secondary: Abnormal update rate timeout
Same fault as SPN 524038 FMI 9 for the CAN Main Secondary message. One cyclic message between the Main and the Secondary ECU is missing; the code number says which of the exchanged messages, and the pair of controllers cross-check less. Deutz list: KWP code 1292, blink code 8-3-2.· Lost messageLost messageCheck soonCauses
- CAN wire open, shorted or a connector loose on the path to the sender
- Sender not powered, in reset or switched off
Checks
- 1Look at the private CAN wires and plugs between the two controllers and watch the message status in SerDia.
- 2Check the supply and ground of the sending control unit with the key on
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Deutz SPN 524047 FMI 9CAN Main Secondary: Abnormal update rate timeout
Same fault as SPN 524038 FMI 9 for the CAN Main Secondary message. One cyclic message between the Main and the Secondary ECU is missing; the code number says which of the exchanged messages, and the pair of controllers cross-check less. Deutz list: KWP code 1293, blink code 8-3-3.· Lost messageLost messageCheck soonCauses
- CAN wire open, shorted or a connector loose on the path to the sender
- Sender not powered, in reset or switched off
Checks
- 1Look at the private CAN wires and plugs between the two controllers and watch the message status in SerDia.
- 2Check the supply and ground of the sending control unit with the key on
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Deutz SPN 524048 FMI 9CAN Main Secondary: Abnormal update rate timeout
Same fault as SPN 524038 FMI 9 for the CAN Main Secondary message. One cyclic message between the Main and the Secondary ECU is missing; the code number says which of the exchanged messages, and the pair of controllers cross-check less. Deutz list: KWP code 1294, blink code 8-3-4.· Lost messageLost messageCheck soonCauses
- CAN wire open, shorted or a connector loose on the path to the sender
- Sender not powered, in reset or switched off
Checks
- 1Look at the private CAN wires and plugs between the two controllers and watch the message status in SerDia.
- 2Check the supply and ground of the sending control unit with the key on
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Deutz SPN 524069 FMI 9CAN Main Secondary: Abnormal update rate timeout
Same fault as SPN 524038 FMI 9 for the CAN Main Secondary message. One cyclic message between the Main and the Secondary ECU is missing; the code number says which of the exchanged messages, and the pair of controllers cross-check less. Deutz list: KWP code 1345, blink code 8-9-6.· Lost messageLost messageCheck soonCauses
- CAN wire open, shorted or a connector loose on the path to the sender
- Sender not powered, in reset or switched off
Checks
- 1Look at the private CAN wires and plugs between the two controllers and watch the message status in SerDia.
- 2Check the supply and ground of the sending control unit with the key on
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Deutz SPN 524189 FMI 9CAN Main Secondary: Abnormal update rate timeout
Same fault as SPN 524038 FMI 9 for the CAN Main Secondary message. One cyclic message between the Main and the Secondary ECU is missing; the code number says which of the exchanged messages, and the pair of controllers cross-check less. Deutz list: KWP code 1889, blink code 2-6-9.· Lost messageLost messageCheck soonCauses
- CAN wire open, shorted or a connector loose on the path to the sender
- Sender not powered, in reset or switched off
Checks
- 1Look at the private CAN wires and plugs between the two controllers and watch the message status in SerDia.
- 2Check the supply and ground of the sending control unit with the key on
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Battery voltage failure on Secondary ECU triggers collective fault Main1 code
Deutz SPN 524234 FMI 11Battery voltage failure on Secondary ECU triggers collective fault Main: Root cause not known
The Secondary and Main controllers exchange status, and the EMR4 logged an event for the battery voltage failure on Secondary ECU triggers collective fault Main (on engines with a Main and a Secondary ECU) with a cause it could not name. It is usually a consequence of another fault on the other controller. Deutz list: KWP code 1975, blink code 3-1-5. The Secondary ECU saw a battery voltage failure at its own supply and reported it, so a dip or a poor feed at the Secondary ECU is the first fault.· OtherOtherCheck soonCauses
- The original fault is stored on the other controller
- Interrupted CAN link or supply between the two controllers
Checks
- 1Read the stored faults of the other controller and start with the oldest
- 2Fix that fault, then clear both controllers and test run the engine
- 3Measure voltage at the Secondary ECU during cranking.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
CAN failure on Secondary ECU triggers collective fault Main1 code
Deutz SPN 524235 FMI 11CAN failure on Secondary ECU triggers collective fault Main: Root cause not known
The Secondary and Main controllers exchange status, and the EMR4 logged an event for the CAN failure on Secondary ECU triggers collective fault Main (on engines with a Main and a Secondary ECU) with a cause it could not name. It is usually a consequence of another fault on the other controller. Deutz list: KWP code 1976, blink code 3-1-5. The Secondary ECU reported a failure of its own CAN connection to the Main ECU.· Lost messageLost messageCheck soonCauses
- The original fault is stored on the other controller
- Interrupted CAN link or supply between the two controllers
Checks
- 1Read the stored faults of the other controller and start with the oldest
- 2Fix that fault, then clear both controllers and test run the engine
- 3Check the CAN wires and plug of the Secondary ECU.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
ECU monitoring failure on Secondary ECU triggers collective fault Main1 code
Deutz SPN 524236 FMI 11ECU monitoring failure on Secondary ECU triggers collective fault Main: Root cause not known
The Secondary and Main controllers exchange status, and the EMR4 logged an event for the ECU monitoring failure on Secondary ECU triggers collective fault Main (on engines with a Main and a Secondary ECU) with a cause it could not name. It is usually a consequence of another fault on the other controller. Deutz list: KWP code 1977, blink code 3-1-5. The monitoring function inside the Secondary ECU failed, the self-check that watches the main processor.· OtherOtherCheck soonCauses
- The original fault is stored on the other controller
- Interrupted CAN link or supply between the two controllers
Checks
- 1Read the stored faults of the other controller and start with the oldest
- 2Fix that fault, then clear both controllers and test run the engine
- 3Check the supply of the Secondary ECU and then have it tested.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
ECU failure on Secondary ECU triggers collective fault Main2 codes
Deutz SPN 524237 FMI 11ECU failure on Secondary ECU triggers collective fault Main: Root cause not known
The Secondary and Main controllers exchange status, and the EMR4 logged an event for the ECU failure on Secondary ECU triggers collective fault Main (on engines with a Main and a Secondary ECU) with a cause it could not name. It is usually a consequence of another fault on the other controller. Deutz list: KWP code 1978, blink code 3-1-5. The Secondary ECU reported an internal failure and the Main ECU logged the consequence.· OtherOtherCheck soonCauses
- The original fault is stored on the other controller
- Interrupted CAN link or supply between the two controllers
Checks
- 1Read the stored faults of the other controller and start with the oldest
- 2Fix that fault, then clear both controllers and test run the engine
- 3Check supply and ground of the Secondary ECU before suspecting the unit.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Deutz SPN 524238 FMI 11ECU failure on Secondary ECU triggers collective fault Main: Root cause not known
Same fault as SPN 524237 FMI 11 for the ECU failure on Secondary ECU triggers collective fault Main message. The Secondary ECU reported an internal failure and the Main ECU logged the consequence. Deutz list: KWP code 1979, blink code 3-1-5.· OtherOtherCheck soonCauses
- The original fault is stored on the other controller
- Interrupted CAN link or supply between the two controllers
Checks
- 1Check supply and ground of the Secondary ECU before suspecting the unit.
- 2Read the stored faults of the other controller and start with the oldest
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Software reset failure on Secondary ECU triggers collective fault Main1 code
Deutz SPN 524242 FMI 11Software reset failure on Secondary ECU triggers collective fault Main: Root cause not known
The Secondary and Main controllers exchange status, and the EMR4 logged an event for the software reset failure on Secondary ECU triggers collective fault Main (on engines with a Main and a Secondary ECU) with a cause it could not name. It is usually a consequence of another fault on the other controller. Deutz list: KWP code 1983, blink code 3-1-5. The Secondary ECU restarted its software on its own, which is the signature of a supply dip or an internal watchdog.· Part or controllerPart or controllerCheck soonCauses
- The original fault is stored on the other controller
- Interrupted CAN link or supply between the two controllers
Checks
- 1Read the stored faults of the other controller and start with the oldest
- 2Fix that fault, then clear both controllers and test run the engine
- 3Look for voltage dips at the Secondary ECU feed when the code was stored.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Engine speed signal failure on Secondary ECU triggers collective fault Main1 code
Deutz SPN 524243 FMI 11Engine speed signal failure on Secondary ECU triggers collective fault Main: Root cause not known
The Secondary and Main controllers exchange status, and the EMR4 logged an event for the engine speed signal failure on Secondary ECU triggers collective fault Main (on engines with a Main and a Secondary ECU) with a cause it could not name. It is usually a consequence of another fault on the other controller. Deutz list: KWP code 1984, blink code 3-1-5. The Secondary ECU lost or distrusted the engine speed signal, which it needs for its own monitoring.· OtherOtherCheck soonCauses
- The original fault is stored on the other controller
- Interrupted CAN link or supply between the two controllers
Checks
- 1Read the stored faults of the other controller and start with the oldest
- 2Fix that fault, then clear both controllers and test run the engine
- 3Read engine speed on both controllers and check the speed sensor wiring to the Secondary ECU.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Shared checks
Checks, in order
- 1Read the dataset and software versions of both controllers in SerDia and compare them
- 2Measure supply and ground at both controllers with the key on
- 3Check the wiring of the link for chafing and spread pins
- 4Read the engine speed on both controllers and compare the two
- 5Clear the codes on both controllers after the repair and see which one logs first
Causes
- Private CAN link between the Main and Secondary ECU open or shorted
- Secondary ECU unpowered because of its fuse, supply or ground, or reset by supply dips
- Datasets of the two controllers not matching
- Terminating resistance wrong on the link
Most codes here: lost message (14 of 20)
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
When to stop
You'll notice: A warning lamp or limited function.
Most sensor and wiring faults can be traced with a multimeter and the wiring diagram. Disconnect the battery before unplugging controllers; if the controller itself is suspect or needs programming, that needs the dealer’s service tool.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.