Skyjack · GP102 module LED flash codes
Skyjack Load and height sensors and load calibration fault codes
This page covers the load pressure transducer, the height sensor and the load calibration procedure: sensor range codes, calibration status, start checks and data quality messages. The load pressure transducer on P4-2 and the height sensor on P4-3 each give the GP102 a voltage that must stay inside a fixed range.
More about these partsLess
The GP102 needs a stored height and load calibration before the overload system works. The handheld calibration tool checks the machine state before it begins: self-test finished, ground mode, all switches released, machine level and the correct first function. These F-codes report that the finished calibration data is not usable: height not back to zero, too few measurements or an unacceptable fine tune result.
Where this code shows
Find the LED on the GP102 module (older SJIII scissors) or the display and keypad in the hydraulic tray (Skycoded machines).
What do these codes mean?
Skyjack codes F01 to F98 are all about the load and height sensors and load calibration. Most are part or controller faults; none needs an immediate stop. Start with this check: read the sensor outputs in DIAGNOSTICS, SENSORS with the platform down, moving and at full height.
How urgent are they?
None of the 25 codes here means stop now; 19 can wait until the shift ends, but find the cause before the next one; 6 are information only.
- Check soon19
- Info6
What should I check first?
Read the sensor outputs in DIAGNOSTICS, SENSORS with the platform down, moving and at full height
Shared checks25 of 25
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
Skyjack F01Calibration F01: check HWFS
The handheld calibration refused to start because the GP102 start-up self-tests are not finished. Read the HELP message on the module for more detail.· Part or controllerPart or controllerInfoCauses
- Start-up tests still running or failed
- Module reporting an HWFS fault
Checks
- 1Wait for start-up to finish and read the HELP message
- 2Check the LED for a 7-x code and deal with that first
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Skyjack F02Calibration F02: not in ground mode
The calibration was refused because the machine is not in ground mode. Calibration can only be carried out from the ground controls with the input at P2-2 high.· Lost messageLost messageInfoCauses
- Platform controls selected instead of ground controls
- P2-2 input not high
Checks
- 1Select the ground controls and try again
- 2Measure that the P2-2 input is high in ground mode
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Skyjack F03Calibration F03: not stopped
The calibration was refused because a function switch is closed. Every switch must be released before the procedure starts.· Part or controllerPart or controllerInfoCauses
- Joystick or function switch held or stuck
- Switch input shorted
Checks
- 1Open diagnostics and switches in the handheld tool to see which switch is closed
- 2Release or repair the switch that shows closed
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Skyjack F04Calibration F04: tilted
The calibration was refused because the machine reads as tilted. It must be level, and if it is level the module level setting has to be redone.· Part or controllerPart or controllerCheck soonCauses
- Machine standing on a slope
- GP102 tilt level not set
Checks
- 1Move to level ground and repeat
- 2Use SETUPS, TILT SETUPS to set the GP102 level
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Skyjack F05Calibration F05: bad height at start
The height sensor signal on P4-3 is out of range at the start of calibration. It should read about 3.7 V with the platform down.· Part or controllerPart or controllerCheck soonCauses
- Height sensor out of adjustment
- Wiring open or shorted giving 0 V or 5 V
Checks
- 1Read the sensor in DIAGNOSTICS, SENSORS and compare it with 3.7 V
- 2A reading of 0 V or 5 V points to wiring, so check the P4-3 circuit
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Skyjack 6-1Height not calibrated
The module has no valid height calibration stored, so it does not trust the height sensor. The manual says an EZcal is required.· Part or controllerPart or controllerCheck soonCauses
- Controller replaced or reset
- Height sensor replaced
- Calibration data lost
- Calibration aborted part way
Checks
- 1Confirm the height sensor and its wiring are good before calibrating anything
- 2Run the EZcal procedure from the service manual with the hand-held tool
- 3Check the height signal on P4-3 changes smoothly as the platform rises and falls
- 4Repeat the calibration and check the values are saved after power off and on
- 5Cycle power and read the LED again to confirm 6-1 has gone
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Skyjack 6-2Load not calibrated
The module has no valid load calibration for the pressure transducer, so it cannot judge overload correctly. The manual says an EZcal is required.· Part or controllerPart or controllerCheck soonCauses
- Controller replaced
- Pressure transducer replaced
- Memory lost
- Previous calibration did not finish
Checks
- 1Check the transducer signal on P4-2 is within the 0.5 V to 4.5 V range before calibrating
- 2Run the EZcal procedure from the service manual
- 3Repeat the calibration with the platform empty as the manual describes
- 4Confirm the overload warning triggers correctly with a known load afterwards
- 5Cycle power and check the LED reads steady on
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Skyjack 6-3No last calibration date
The module has no record of when it was last calibrated. The manual gives it the same EZcal action as the height and load messages.· Part or controllerPart or controllerCheck soonCauses
- New or reset module
- Calibration never performed
- Memory lost after a power loss
- Wrong module type installed
Checks
- 1Check the module part number is correct for this machine and serial range
- 2Run the EZcal procedure from the service manual with the hand-held tool
- 3Check the battery supply is steady during the calibration run
- 4Cycle power and confirm the code has gone and the LED is steady on
- 5Write the date of the calibration on the service record
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Skyjack 6-4Invalid load, check sensors
The pressure transducer signal into P4 pin 2 is outside its normal range, so the module cannot trust the load reading. The manual gives 0.5 V at zero pressure up to 4.5 V at maximum.· OtherOtherCheck soonCauses
- Pressure transducer failed or disconnected
- Short or open on the signal wire to P4-2
- Supply fault on P4-1
- Transducer damaged at the lift cylinder
Checks
- 1Measure the output at P4-2; it should lie between 0.5 V and 4.5 V and change with load and platform position
- 2Check the 5 V reference to the transducer is present at the plug
- 3Look for a short or open on the signal wire between the transducer and P4
- 4Check the connector at the transducer on the lift cylinder for oil and corrosion
- 5Replace the transducer if its signal does not move with cylinder pressure
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Skyjack 6-5Invalid height, check sensor
The height transducer signal into P4 pin 3 is out of range. The manual says it should be between 0.4 V and 4.6 V and vary with platform position.· OtherOtherCheck soonCauses
- Height sensor failed
- Open or short on the P4-3 signal wire
- Supply fault on P4-1
- Connector corrosion
Checks
- 1Measure P4-3; it should stay between 0.4 V and 4.6 V through the whole travel
- 2Raise and lower the platform and watch the voltage move smoothly without jumps
- 3Check the sensor mounting and linkage for looseness or damage
- 4Check the P4 connector for corrosion and bent pins
- 5Replace the sensor if the reading is stuck at one value
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Skyjack 6-6Overload functions disabled
The module has been configured to ignore the overload function. The manual says this is not a true fault; it just reports the setting.· Real conditionReal conditionInfoCauses
- Module configured with overload suppressed
- Factory override still active
- Wrong configuration after replacement
Checks
- 1Check the machine configuration against the manual for your serial number
- 2Confirm whether the setting was intended by whoever configured the module
- 3Reconfigure and recalibrate if the load system should be active
- 4Test the overload warning with a known weight once it is re-enabled
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Skyjack 6-7Factory override
The module is in a factory override state. The manual lists it beside 6-6 as not a real fault.· OtherOtherInfoCauses
- Module still in factory configuration
- Configuration not completed after installation
- Wrong module fitted
Checks
- 1Check the configuration setting in the module with the hand-held tool
- 2Complete the setup per the service manual if it was not finished
- 3Verify overload and tilt operation after the setup is complete
- 4Cycle power and check the LED shows steady on
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Skyjack F09Calibration F09: bad height at start (second check)
The height sensor output at P4-3 is again out of range at the start of calibration, and it must be about 3.7 V before the procedure can go on.· Lost messageLost messageCheck soonCauses
- Height sensor not set at the starting position
- Sensor wiring fault
Checks
- 1Check the sensor output in DIAGNOSTICS, SENSORS
- 2Adjust or replace the sensor if it will not read 3.7 V when lowered
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Skyjack F10Calibration F10: bad height at end
The height sensor output at P4-3 was out of range at the end of the calibration. It must sit between 0.9 V and 4.1 V when the platform is fully raised.· Part or controllerPart or controllerCheck soonCauses
- Sensor travel too small or too large
- Wiring fault giving 0 V or 5 V
Checks
- 1Read the sensor in DIAGNOSTICS, SENSORS at full height
- 2Check the P4-3 wiring if the reading is 0 V or 5 V
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Skyjack F11Calibration F11: not up
This message appears at the start of the calibration when a function other than UP was selected. Only the UP function may be used at that point.· Part or controllerPart or controllerInfoCauses
- Wrong function selected on the controls
- Lift and down switches both touched
Checks
- 1Select only the UP function
- 2Release all other switches and repeat the step
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Skyjack F13Calibration F13: low height range
At the end of calibration the height signal did not change enough to estimate platform height. A difference of at least 1 V over the lift is expected.· Part or controllerPart or controllerCheck soonCauses
- UP switch released too early so the platform was not fully raised
- Height sensor linkage slipping
Checks
- 1Repeat the calibration holding UP until the platform is fully raised
- 2Check the sensor mounting and linkage moves with the arms
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Skyjack F20Calibration F20: height not 0 percent
After the platform was fully lowered in a static lift the height reading was not 0 percent. It has to return to the same height every time.· Part or controllerPart or controllerCheck soonCauses
- Height sensor drifting or slipping
- Platform not fully down
Checks
- 1Check the height in DIAGNOSTICS, SYSTEM at the bottom
- 2Check the sensor mounting
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Skyjack F28Calibration F28: bad height during run
A problem with the height sensor output at P4-3 was seen during the calibration. The signal has to stay between 1.0 V and 4.0 V throughout.· Part or controllerPart or controllerCheck soonCauses
- Sensor dropping out during travel
- Loose or damaged sensor wiring
Checks
- 1Watch the sensor reading while the platform moves
- 2Check the sensor wiring and plug for loose pins
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Skyjack F42Calibration F42: low pressure at start
The pressure transducer output at P4-2 is too low (0.5 V or less) at the beginning of calibration, so no usable load signal is present.· Part or controllerPart or controllerCheck soonCauses
- Pressure transducer failed or unplugged
- Wiring open to P4-2
Checks
- 1Read the transducer in DIAGNOSTICS, SENSORS
- 2Check the transducer plug and the wiring to P4-2
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Skyjack F43Calibration F43: high pressure at start
The pressure transducer output at P4-2 is too high (4.5 V or more) at the beginning of calibration, which is out of its normal range.· Part or controllerPart or controllerCheck soonCauses
- Transducer failed high
- Signal shorted to supply
Checks
- 1Read the transducer in DIAGNOSTICS, SENSORS
- 2Check the P4-2 wiring for a short to supply
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Skyjack F44Calibration F44: low pressure at a measurement point
The pressure transducer output at P4-2 fell to 0.5 V or less at one of the measurement points during calibration.· Part or controllerPart or controllerCheck soonCauses
- Transducer dropping out
- Loose wiring or connector
Checks
- 1Read the transducer while the platform moves
- 2Check the connector and wiring to P4-2
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Skyjack F45Calibration F45: high pressure at a measurement point
The pressure transducer output at P4-2 rose to 4.5 V or more at one of the measurement points during calibration.· Part or controllerPart or controllerCheck soonCauses
- Transducer failing high
- Supply short on the signal wire
Checks
- 1Read the transducer while the platform moves
- 2Check the P4-2 wiring
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Skyjack F48Calibration F48: bad pressure at start
The pressure transducer output at P4-2 is out of range at the beginning of calibration, so the load calibration cannot start.· Part or controllerPart or controllerCheck soonCauses
- Transducer failed
- Wiring fault on P4-2
Checks
- 1Read the output in DIAGNOSTICS, SENSORS
- 2Check the transducer and its wiring
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Skyjack F52Calibration F52: too few measurements
Not enough measurements were recorded during the lifting or lowering part of calibration, so the data set is incomplete.· Part or controllerPart or controllerCheck soonCauses
- Moving too fast or stopping too early
- Platform not taken through its full travel
Checks
- 1Repeat the procedure and follow the steps slowly
- 2Run the platform through its full travel
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Skyjack F98Calibration F98: fine tune out of range
The fine tune calibration is unacceptable. Skyjack points to a faulty transducer or a faulty or open holding valve or emergency lowering valve.· Part or controllerPart or controllerCheck soonCauses
- Pressure transducer faulty
- Holding valve or emergency lowering valve leaking or open
Checks
- 1Check the pressure transducer reading
- 2Check the holding valves and the emergency lowering valve
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Shared checks
Checks, in order
- 1Read the sensor outputs in DIAGNOSTICS, SENSORS with the platform down, moving and at full height
- 2Read the calibration state in the handheld tool before repeating any procedure
- 3Wait for the start-up codes to clear and read the HELP message on the module first
- 4Check the height reading at the bottom in DIAGNOSTICS, SYSTEM after each full lowering
- 5Measure P4-2 and P4-3 and compare them with the range in the manual
- 6Run the height and load calibration from section 5.3-6 of the manual
- 7Select the ground controls and release every joystick and switch before starting
Causes
- Sensor failed, unplugged or its supply missing
- Module replaced and never calibrated
- Start-up self-test not finished
- Platform not returning to the same bottom height each time
Most codes here: part or controller (19 of 25)
Check power and ground at the module connector with the key on, then its fuses.
When to stop
You'll notice: Overload protection or height limiting acts wrongly and the LED shows 6/4 or 6/5, or a load calibration stops with a bad height, low height range or bad pressure message.
Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Sources
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.