Skyjack · GP102 module LED flash codes

Skyjack Load and height sensors and load calibration fault codes

This page covers the load pressure transducer, the height sensor and the load calibration procedure: sensor range codes, calibration status, start checks and data quality messages. The load pressure transducer on P4-2 and the height sensor on P4-3 each give the GP102 a voltage that must stay inside a fixed range.

More about these parts

The GP102 needs a stored height and load calibration before the overload system works. The handheld calibration tool checks the machine state before it begins: self-test finished, ground mode, all switches released, machine level and the correct first function. These F-codes report that the finished calibration data is not usable: height not back to zero, too few measurements or an unacceptable fine tune result.

FaultCheck6-1Skyjack · Load and height sensors and load calibration
Code shows hereFAULT6-1

Where this code shows

Find the LED on the GP102 module (older SJIII scissors) or the display and keypad in the hydraulic tray (Skycoded machines).

What do these codes mean?

Skyjack codes F01 to F98 are all about the load and height sensors and load calibration. Most are part or controller faults; none needs an immediate stop. Start with this check: read the sensor outputs in DIAGNOSTICS, SENSORS with the platform down, moving and at full height.

How urgent are they?

None of the 25 codes here means stop now; 19 can wait until the shift ends, but find the cause before the next one; 6 are information only.

  • Check soon19
  • Info6

What should I check first?

Read the sensor outputs in DIAGNOSTICS, SENSORS with the platform down, moving and at full height

Shared checks

25 of 25

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Skyjack F01Calibration F01: check HWFS

    The handheld calibration refused to start because the GP102 start-up self-tests are not finished.· Part or controller
    Info

    Causes

    • Start-up tests still running or failed
    • Module reporting an HWFS fault

    Checks

    1. 1Wait for start-up to finish and read the HELP message
    2. 2Check the LED for a 7-x code and deal with that first
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Skyjack F02Calibration F02: not in ground mode

    The calibration was refused because the machine is not in ground mode.· Lost message
    Info

    Causes

    • Platform controls selected instead of ground controls
    • P2-2 input not high

    Checks

    1. 1Select the ground controls and try again
    2. 2Measure that the P2-2 input is high in ground mode
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Skyjack F03Calibration F03: not stopped

    The calibration was refused because a function switch is closed.· Part or controller
    Info

    Causes

    • Joystick or function switch held or stuck
    • Switch input shorted

    Checks

    1. 1Open diagnostics and switches in the handheld tool to see which switch is closed
    2. 2Release or repair the switch that shows closed
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Skyjack F04Calibration F04: tilted

    The calibration was refused because the machine reads as tilted.· Part or controller
    Check soon

    Causes

    • Machine standing on a slope
    • GP102 tilt level not set

    Checks

    1. 1Move to level ground and repeat
    2. 2Use SETUPS, TILT SETUPS to set the GP102 level
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Skyjack F05Calibration F05: bad height at start

    The height sensor signal on P4-3 is out of range at the start of calibration.· Part or controller
    Check soon

    Causes

    • Height sensor out of adjustment
    • Wiring open or shorted giving 0 V or 5 V

    Checks

    1. 1Read the sensor in DIAGNOSTICS, SENSORS and compare it with 3.7 V
    2. 2A reading of 0 V or 5 V points to wiring, so check the P4-3 circuit
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Skyjack 6-1Height not calibrated

    The module has no valid height calibration stored, so it does not trust the height sensor.· Part or controller
    Check soon

    Causes

    • Controller replaced or reset
    • Height sensor replaced
    • Calibration data lost
    • Calibration aborted part way

    Checks

    1. 1Confirm the height sensor and its wiring are good before calibrating anything
    2. 2Run the EZcal procedure from the service manual with the hand-held tool
    3. 3Check the height signal on P4-3 changes smoothly as the platform rises and falls
    4. 4Repeat the calibration and check the values are saved after power off and on
    5. 5Cycle power and read the LED again to confirm 6-1 has gone
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Skyjack 6-2Load not calibrated

    The module has no valid load calibration for the pressure transducer, so it cannot judge overload correctly.· Part or controller
    Check soon

    Causes

    • Controller replaced
    • Pressure transducer replaced
    • Memory lost
    • Previous calibration did not finish

    Checks

    1. 1Check the transducer signal on P4-2 is within the 0.5 V to 4.5 V range before calibrating
    2. 2Run the EZcal procedure from the service manual
    3. 3Repeat the calibration with the platform empty as the manual describes
    4. 4Confirm the overload warning triggers correctly with a known load afterwards
    5. 5Cycle power and check the LED reads steady on
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Skyjack 6-3No last calibration date

    The module has no record of when it was last calibrated.· Part or controller
    Check soon

    Causes

    • New or reset module
    • Calibration never performed
    • Memory lost after a power loss
    • Wrong module type installed

    Checks

    1. 1Check the module part number is correct for this machine and serial range
    2. 2Run the EZcal procedure from the service manual with the hand-held tool
    3. 3Check the battery supply is steady during the calibration run
    4. 4Cycle power and confirm the code has gone and the LED is steady on
    5. 5Write the date of the calibration on the service record
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Skyjack 6-4Invalid load, check sensors

    The pressure transducer signal into P4 pin 2 is outside its normal range, so the module cannot trust the load reading.· Other
    Check soon

    Causes

    • Pressure transducer failed or disconnected
    • Short or open on the signal wire to P4-2
    • Supply fault on P4-1
    • Transducer damaged at the lift cylinder

    Checks

    1. 1Measure the output at P4-2; it should lie between 0.5 V and 4.5 V and change with load and platform position
    2. 2Check the 5 V reference to the transducer is present at the plug
    3. 3Look for a short or open on the signal wire between the transducer and P4
    4. 4Check the connector at the transducer on the lift cylinder for oil and corrosion
    5. 5Replace the transducer if its signal does not move with cylinder pressure
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Skyjack 6-5Invalid height, check sensor

    The height transducer signal into P4 pin 3 is out of range.· Other
    Check soon

    Causes

    • Height sensor failed
    • Open or short on the P4-3 signal wire
    • Supply fault on P4-1
    • Connector corrosion

    Checks

    1. 1Measure P4-3; it should stay between 0.4 V and 4.6 V through the whole travel
    2. 2Raise and lower the platform and watch the voltage move smoothly without jumps
    3. 3Check the sensor mounting and linkage for looseness or damage
    4. 4Check the P4 connector for corrosion and bent pins
    5. 5Replace the sensor if the reading is stuck at one value
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Skyjack 6-6Overload functions disabled

    The module has been configured to ignore the overload function.· Real condition
    Info

    Causes

    • Module configured with overload suppressed
    • Factory override still active
    • Wrong configuration after replacement

    Checks

    1. 1Check the machine configuration against the manual for your serial number
    2. 2Confirm whether the setting was intended by whoever configured the module
    3. 3Reconfigure and recalibrate if the load system should be active
    4. 4Test the overload warning with a known weight once it is re-enabled
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Skyjack 6-7Factory override

    The module is in a factory override state.· Other
    Info

    Causes

    • Module still in factory configuration
    • Configuration not completed after installation
    • Wrong module fitted

    Checks

    1. 1Check the configuration setting in the module with the hand-held tool
    2. 2Complete the setup per the service manual if it was not finished
    3. 3Verify overload and tilt operation after the setup is complete
    4. 4Cycle power and check the LED shows steady on
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Skyjack F09Calibration F09: bad height at start (second check)

    The height sensor output at P4-3 is again out of range at the start of calibration, and it must be about 3.7 V before the procedure can go on.· Lost message
    Check soon

    Causes

    • Height sensor not set at the starting position
    • Sensor wiring fault

    Checks

    1. 1Check the sensor output in DIAGNOSTICS, SENSORS
    2. 2Adjust or replace the sensor if it will not read 3.7 V when lowered
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Skyjack F10Calibration F10: bad height at end

    The height sensor output at P4-3 was out of range at the end of the calibration.· Part or controller
    Check soon

    Causes

    • Sensor travel too small or too large
    • Wiring fault giving 0 V or 5 V

    Checks

    1. 1Read the sensor in DIAGNOSTICS, SENSORS at full height
    2. 2Check the P4-3 wiring if the reading is 0 V or 5 V
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Skyjack F11Calibration F11: not up

    This message appears at the start of the calibration when a function other than UP was selected.· Part or controller
    Info

    Causes

    • Wrong function selected on the controls
    • Lift and down switches both touched

    Checks

    1. 1Select only the UP function
    2. 2Release all other switches and repeat the step
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Skyjack F13Calibration F13: low height range

    At the end of calibration the height signal did not change enough to estimate platform height.· Part or controller
    Check soon

    Causes

    • UP switch released too early so the platform was not fully raised
    • Height sensor linkage slipping

    Checks

    1. 1Repeat the calibration holding UP until the platform is fully raised
    2. 2Check the sensor mounting and linkage moves with the arms
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Skyjack F20Calibration F20: height not 0 percent

    After the platform was fully lowered in a static lift the height reading was not 0 percent.· Part or controller
    Check soon

    Causes

    • Height sensor drifting or slipping
    • Platform not fully down

    Checks

    1. 1Check the height in DIAGNOSTICS, SYSTEM at the bottom
    2. 2Check the sensor mounting
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Skyjack F28Calibration F28: bad height during run

    A problem with the height sensor output at P4-3 was seen during the calibration.· Part or controller
    Check soon

    Causes

    • Sensor dropping out during travel
    • Loose or damaged sensor wiring

    Checks

    1. 1Watch the sensor reading while the platform moves
    2. 2Check the sensor wiring and plug for loose pins
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Skyjack F42Calibration F42: low pressure at start

    The pressure transducer output at P4-2 is too low (0.5 V or less) at the beginning of calibration, so no usable load signal is present.· Part or controller
    Check soon

    Causes

    • Pressure transducer failed or unplugged
    • Wiring open to P4-2

    Checks

    1. 1Read the transducer in DIAGNOSTICS, SENSORS
    2. 2Check the transducer plug and the wiring to P4-2
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Skyjack F43Calibration F43: high pressure at start

    The pressure transducer output at P4-2 is too high (4.5 V or more) at the beginning of calibration, which is out of its normal range.· Part or controller
    Check soon

    Causes

    • Transducer failed high
    • Signal shorted to supply

    Checks

    1. 1Read the transducer in DIAGNOSTICS, SENSORS
    2. 2Check the P4-2 wiring for a short to supply
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Skyjack F44Calibration F44: low pressure at a measurement point

    The pressure transducer output at P4-2 fell to 0.5 V or less at one of the measurement points during calibration.· Part or controller
    Check soon

    Causes

    • Transducer dropping out
    • Loose wiring or connector

    Checks

    1. 1Read the transducer while the platform moves
    2. 2Check the connector and wiring to P4-2
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Skyjack F45Calibration F45: high pressure at a measurement point

    The pressure transducer output at P4-2 rose to 4.5 V or more at one of the measurement points during calibration.· Part or controller
    Check soon

    Causes

    • Transducer failing high
    • Supply short on the signal wire

    Checks

    1. 1Read the transducer while the platform moves
    2. 2Check the P4-2 wiring
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Skyjack F48Calibration F48: bad pressure at start

    The pressure transducer output at P4-2 is out of range at the beginning of calibration, so the load calibration cannot start.· Part or controller
    Check soon

    Causes

    • Transducer failed
    • Wiring fault on P4-2

    Checks

    1. 1Read the output in DIAGNOSTICS, SENSORS
    2. 2Check the transducer and its wiring
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Skyjack F52Calibration F52: too few measurements

    Not enough measurements were recorded during the lifting or lowering part of calibration, so the data set is incomplete.· Part or controller
    Check soon

    Causes

    • Moving too fast or stopping too early
    • Platform not taken through its full travel

    Checks

    1. 1Repeat the procedure and follow the steps slowly
    2. 2Run the platform through its full travel
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Skyjack F98Calibration F98: fine tune out of range

    The fine tune calibration is unacceptable.· Part or controller
    Check soon

    Causes

    • Pressure transducer faulty
    • Holding valve or emergency lowering valve leaking or open

    Checks

    1. 1Check the pressure transducer reading
    2. 2Check the holding valves and the emergency lowering valve
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

Shared checks

Checks, in order

  1. 1Read the sensor outputs in DIAGNOSTICS, SENSORS with the platform down, moving and at full height
  2. 2Read the calibration state in the handheld tool before repeating any procedure
  3. 3Wait for the start-up codes to clear and read the HELP message on the module first
  4. 4Check the height reading at the bottom in DIAGNOSTICS, SYSTEM after each full lowering
  5. 5Measure P4-2 and P4-3 and compare them with the range in the manual
  6. 6Run the height and load calibration from section 5.3-6 of the manual
  7. 7Select the ground controls and release every joystick and switch before starting

Causes

  • Sensor failed, unplugged or its supply missing
  • Module replaced and never calibrated
  • Start-up self-test not finished
  • Platform not returning to the same bottom height each time

Most codes here: part or controller (19 of 25)

Check power and ground at the module connector with the key on, then its fuses.

When to stop

You'll notice: Overload protection or height limiting acts wrongly and the LED shows 6/4 or 6/5, or a load calibration stops with a bad height, low height range or bad pressure message.

Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.