Skyjack · GP102 module LED flash codes
Skyjack Tilt, overload, armguard and elevation switch codes fault codes
This page covers the GP102 cut-outs and the switches behind them: tilt, overload and height cut-outs, the armguard stop, and the elevation switch in both running faults and calibration F-codes. The GP102 module watches the tilt sensor, the load pressure transducer and the height sensor.
More about these partsLess
The armguard (scissor-arm guard) input tells the GP102 that something is touching the guard. The elevation switch on P2-10 tells the GP102 whether the platform is lowered or raised, and the module uses it to allow drive, set limits and cross-check the height sensor.
Where this code shows
Find the LED on the GP102 module (older SJIII scissors) or the display and keypad in the hydraulic tray (Skycoded machines).
What do these codes mean?
Skyjack codes 1-1 to F47 are all about the tilt, overload, armguard and elevation switch codes. Most are part or controller faults; none needs an immediate stop. Start with this check: lower the platform fully and look at the ground under the machine before touching anything.
How urgent are they?
None of the 17 codes here means stop now; 11 can wait until the shift ends, but find the cause before the next one; 6 are information only.
- Check soon11
- Info6
What should I check first?
Lower the platform fully and look at the ground under the machine before touching anything
Shared checks17 of 17
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
Skyjack 1-1Vehicle tilted
The tilt sensor inside the GP102 module sees the machine standing on a slope steeper than its cut-out angle. The module blocks drive and lift-up to protect the machine, so this is a warning about where the machine sits rather than a broken part.· OtherOtherInfoCauses
- Machine parked or driven on a slope or uneven ground
- One wheel or a pothole bar sitting on a kerb, ramp edge or debris
- GP102 module loose or mounted crooked on its bracket, so it reads a false angle
- Tilt sensor reading wrong after the module was replaced
Checks
- 1Lower the platform completely first, then look at what the machine is standing on
- 2Move the machine onto firm level ground and see whether the flash code clears by itself
- 3Check the GP102 module mounting bolts are tight and the module sits flat on its bracket
- 4Put a spirit level on the chassis next to the module to confirm the chassis really is level
- 5If the code stays on level ground, read the LED again for 7-1 (bad tilt sensor) before replacing anything
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Skyjack 1-2Vehicle overloaded
The pressure transducer on the lift cylinder tells the GP102 module the platform load is above the rated limit. The module cuts lift and drive until the extra weight is removed, so it is a load message, not a fault in the module.· Real conditionReal conditionInfoCauses
- More people, tools or material on the platform than the rated capacity
- Platform pressed against a beam or ceiling, which adds to the cylinder pressure
- Lift cylinder pressure transducer reading high or out of calibration
- Load calibration lost after a battery or module change
Checks
- 1Take the load off and compare what was on the platform with the capacity plate
- 2Look for the platform touching an overhead structure and use the emergency lowering if it is trapped
- 3With the platform empty, measure the transducer signal at P4-2; it should sit between 0.5 V and 4.5 V and not at the top of the range
- 4Check the transducer connector and cable at the lift cylinder for oil, water or damage
- 5If an empty platform still reads overloaded, repeat the load calibration (see 6-2)
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Skyjack 1-3Armguard active (lift and drive stopped)
The arm-guard input is blocking movement and the module is reporting that as the reason. It is a status message about the guard circuit, not a failed component.· OtherOtherInfoCauses
- Scissor arm guard tripped by an object or a person
- Guard switch stuck, bent or out of adjustment
- Wire from the guard switch pinched or open at the module plug
- Debris or a tool jammed under the scissor stack
Checks
- 1Walk round the scissor stack and look for anything touching or resting on the guard
- 2Trip the guard by hand and listen for the switch click; look for a bent bracket or seized lever
- 3Check the switch connector for a pushed-back pin or corrosion
- 4Compare with 2-3, which reports the same guard at the moment a function is being driven
- 5After freeing it, cycle the controls and confirm the LED returns to steady on
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Skyjack 1-4Too high, drive prevented
The height transducer shows the platform above the height where driving is allowed. The module blocks drive so the machine cannot be moved with the platform raised; this is normal protection unless it happens with the platform down.· Real conditionReal conditionInfoCauses
- Platform raised above the drive-height cut-out, which is normal behaviour
- Height transducer reading high so the module thinks the platform is higher than it is
- Cable damage between the height sensor and plug P4
- Height calibration missing after the module or sensor was replaced
Checks
- 1Lower the platform fully and see whether drive returns; if it does, the machine is behaving normally
- 2With the platform down, measure the height signal at P4-3; the manual gives 0.4 V to 4.6 V and it should change as the platform rises
- 3Check the P4 plug for corrosion and follow the cable for chafing near the scissor pivots
- 4Raise slowly while watching P4-3; a jump or dropout points at the sensor or its wire
- 5Repeat the height calibration if the sensor or module was changed (see 6-1)
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Skyjack 1-5Too high, lift up prevented
The module is refusing further lift-up because the height or the load and height combination has reached the allowed limit. It is a limit message that only points at a hardware problem if it appears too early.· Real conditionReal conditionInfoCauses
- Platform genuinely at its maximum height
- Height transducer reading high and ending lift early
- Overload or tilt condition active at the same time
- Wrong or stale height calibration
Checks
- 1Check the platform is not already at full height or touching a ceiling
- 2Read the height signal at P4-3 at a known platform height; it should stay between 0.4 V and 4.6 V
- 3Look for an active overload (1-2) or tilt (1-1) code that is also blocking lift
- 4Inspect the P4 cable and connector at the height sensor for damage
- 5Recalibrate the height sensor if the readings disagree with the real height
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Skyjack 2-1Elevation switch shifted?
The module sees the elevation switch change state at a platform position where it should not. That points at the switch, its mounting or the arm that operates it. The manual notes this one does not clear until the switch behaves.· OtherOtherCheck soonCauses
- Elevation switch loose on its bracket so it has moved out of position
- Operating arm or cam bent or worn
- Switch contacts dirty or intermittent
- Wire rubbing at the scissor arm pivot
Checks
- 1Raise and lower the platform slowly and watch the switch operate; it must change state at the same point every time
- 2Check the bracket bolts are tight and the switch has not slid along its slot
- 3Look at the actuating arm for bending or wear marks
- 4Test the switch across its terminals in both positions for a clean open and closed reading
- 5Check the wire at the pivot for chafing, then cycle power and watch whether the code returns
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Skyjack 2-2Elevation switch stuck?
The module sees the elevation switch staying in one state while the platform moves. Unlike a shifted switch the signal never changes, so the switch or its actuator is jammed, or the wire is open.· OtherOtherCheck soonCauses
- Switch seized in the open or closed position
- Actuator not reaching the switch because of damage or wrong position
- Open or shorted wire on the switch circuit
- Dirt or hydraulic oil packed around the switch
Checks
- 1With the platform fully down note the switch state, then raise a little and see if it changes
- 2Push the actuator by hand and listen or feel for a click
- 3Clean around the switch and check the actuator moves freely on its pivot
- 4Check continuity of the switch wires with the plug disconnected to find a break
- 5Replace the switch if it cannot follow the arm, then raise and lower to clear the code
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Skyjack 2-3Armguard active (one-off flash)
This is the arm-guard reason reported while a function is being used. The manual says it appears once and then clears because it only explains why the machine stopped, so it is not a fault by itself.· OtherOtherInfoCauses
- Operator or object tripped the scissor arm guard
- Guard switch sticking and releasing
- Loose connector giving a short pulse on the guard input
- Debris under the arm guard
Checks
- 1Clear anything away from the arm guard and confirm the machine moves again
- 2Trip the guard by hand a few times and check the switch returns freely each time
- 3Wiggle the guard switch connector with the machine powered; a flash code appearing means a loose pin
- 4Compare against 1-3 to tell a standing guard problem from a one-off trip
- 5If it flashes without being touched, look for an intermittent short in the switch wire
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Skyjack F06Calibration F06: elevation switch closed at start
The elevation switch at P2-10 was closed at the start of calibration after the operator confirmed that the platform is down.· Part or controllerPart or controllerCheck soonCauses
- Elevation switch stuck or misadjusted
- Wire to the switch shorted
Checks
- 1Check the platform is really down and the switch is open
- 2Check the elevation switch wiring
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Skyjack F08Calibration F08: elevation switch closed at top
The elevation switch at P2-10 was closed at the end of calibration, when the platform should be fully raised.· Part or controllerPart or controllerCheck soonCauses
- UP switch accidentally released near the start of the lift
- Elevation switch wiring fault
Checks
- 1Repeat the lift without letting go of UP
- 2Check the elevation switch wiring
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Skyjack F15Calibration F15: elevation switch closed at bottom
The elevation switch at P2-10 was closed when the platform had been fully lowered at the end of the calibration.· Part or controllerPart or controllerCheck soonCauses
- DOWN switch released before the platform was fully lowered
- Elevation switch fault
Checks
- 1Lower the platform fully and check the switch
- 2Check the elevation switch wiring
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Skyjack F16Calibration F16: elevation switch opened too low
The elevation switch opened during lift at too low a height, below 5 percent. The recorded value is shown under HEIGHT CALS.· Part or controllerPart or controllerCheck soonCauses
- Elevation switch set too low
- Switch cam out of position
Checks
- 1Check the ElevUp value in CALIBRATIONS, HEIGHT CALS
- 2Set the switch to the manufacturer specification and recalibrate the load
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Skyjack F17Calibration F17: elevation switch opened too high
The elevation switch opened during lift at too high a height, above 25 percent of the travel.· Part or controllerPart or controllerCheck soonCauses
- Elevation switch set too high
- Switch cam out of position
Checks
- 1Check the ElevUp value in CALIBRATIONS, HEIGHT CALS
- 2Set the switch to the manufacturer specification and recalibrate the load
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Skyjack F18Calibration F18: elevation switch closed too low
The elevation switch closed during lowering at too low a height, below 5 percent of the travel.· Part or controllerPart or controllerCheck soonCauses
- Elevation switch set too low
- Switch cam out of position
Checks
- 1Check the ElevDown value in CALIBRATIONS, HEIGHT CALS
- 2Set the switch to the manufacturer specification and recalibrate the load
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Skyjack F19Calibration F19: elevation switch closed too high
The elevation switch closed during lowering at too high a height, above 25 percent of the travel.· Part or controllerPart or controllerCheck soonCauses
- Elevation switch set too high
- Switch cam out of position
Checks
- 1Check the height values in CALIBRATIONS, HEIGHT CALS
- 2Set the switch to the manufacturer specification and recalibrate the load
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Skyjack F46Calibration F46: elevation switch opened twice
The elevation switch opened more than once during the lifting part of the calibration, so the switch is bouncing or unreliable.· Part or controllerPart or controllerCheck soonCauses
- Loose or worn elevation switch
- Intermittent switch wiring
Checks
- 1Check the switch mounting and cam
- 2Check the wiring for intermittent contact
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Skyjack F47Calibration F47: elevation switch closed twice
The elevation switch closed more than once during the lowering part of the calibration, so the switch is bouncing or unreliable.· Part or controllerPart or controllerCheck soonCauses
- Loose or worn elevation switch
- Intermittent switch wiring
Checks
- 1Check the switch mounting and cam
- 2Check the wiring for intermittent contact
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Shared checks
Checks, in order
- 1Lower the platform fully and look at the ground under the machine before touching anything
- 2Walk round the machine and look for anything resting on or against the guard
- 3Raise and lower the platform and watch the switch open and close at the same point every time
- 4Take excess load off the platform and see whether the flash code clears by itself
- 5Operate the guard switch by hand, listen for the click and check the bracket is not bent
- 6Check the switch mounting, cam and bracket for movement or damage
- 7Move the machine to firm level ground and cycle the key switch
Causes
- Machine standing on a slope or on one raised wheel
- Object or person touching the guard
- Elevation switch cam or bracket moved out of adjustment
- Too much weight or a badly placed load on the platform
Most codes here: part or controller (9 of 17)
Check power and ground at the module connector with the key on, then its fuses.
When to stop
You'll notice: A function stops working and the module LED repeats a short flash pattern.
Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Sources
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.