EF Logo

Kubota · Engine ECU - SPN / FMI codes

Kubota Injectors, injector data and crank and cam sensors fault codes

This page covers injection and engine position: injector wiring, drive and charging circuits, injector correction (QR / IQA) data, the crankshaft and camshaft position sensors and the E:9100 rpm sensor error. Each injector has its own coil wire to the engine ECU.

More about these parts

The ECU charges a capacitor to a high voltage to fire the injectors quickly. Each injector has a correction code, called QR or IQA, that the ECU needs to meter fuel exactly. The crankshaft sensor (NE) gives engine speed and the camshaft sensor (G) identifies the cylinder.

FaultStopSPN636-FMI8Kubota · Crankshaft position sensor (NE)
Code shows hereFAULTSPN636-FMI8

Where this code shows

Watch the meter panel: a warning lamp comes on and the E: code scrolls on the display.

What do these codes mean?

Kubota codes SPN636-FMI2 to SPN523605-FMI6 are all about the injectors, injector data and crank and cam sensors. The most common failure type is shorted high (6 of 18); 16 need an immediate stop. Start with this check: identify the injector named by the code in the firing order.

How urgent are they?

16 of 18 codes here mean stop now; the other 2 can wait until the shift ends, but find the cause before the next one.

  • Stop now16
  • Check soon2

What should I check first?

Identify the injector named by the code in the firing order

Shared checks

18 of 18

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Kubota SPN636-FMI2Crankshaft position sensor (NE) - Short to battery

    SPN 636 FMI 2 means the crankshaft position (NE) sensor circuit is shorted to battery positive.· Erratic or implausible
    Stop now

    Causes

    • Wire chafed and touching a live supply wire
    • Failed crankshaft position (NE) sensor
    • Water inside the crankshaft position (NE) sensor connector

    Checks

    1. 1Unplug the crankshaft position (NE) sensor and check with the key on that the wire carries no voltage
    2. 2Follow the harness and look for rubbed insulation next to power wires
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • Kubota SPN636-FMI7NE and G sensor signals out of phase

    SPN 636 FMI 7 means the crankshaft (NE) and camshaft (G) signals no longer line up in timing.· Part or controller
    Stop now

    Causes

    • Loose or damaged crankshaft or camshaft sensor
    • Worn timing gear or pulse wheel
    • Sensor wiring interference

    Checks

    1. 1Check the mounting and gap of both sensors
    2. 2Inspect the pulse wheel and the timing gear for damage or play
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Kubota SPN636-FMI8Crankshaft position sensor (NE) - Open circuit or short to ground

    SPN 636 FMI 8 means the crankshaft speed sensor signal is missing or abnormal.· Erratic or implausible
    Stop now

    Causes

    • Crankshaft sensor failed
    • Sensor wires damaged or open
    • Metal debris or oil on the sensor tip
    • Sensor gap or pulse wheel damage

    Checks

    1. 1Inspect the sensor tip and connector for debris and oil
    2. 2Measure the sensor coil resistance against the manual value
    3. 3Check the harness for chafing and open circuits
    4. 4Check for engine speed on the meter while cranking
    5. 5Replace the crankshaft sensor if the signal is weak or drops out
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • Kubota SPN651-FMI3Injector No.1 harness coil - Open circuit

    SPN 651 FMI 3 means the harness coil of injector No.1 is open, so the ECU cannot fire it.· Shorted high
    Stop now

    Causes

    • Open wire or loose terminal at injector No.1
    • Injector No.1 coil open
    • Chafed injector harness under the valve cover

    Checks

    1. 1Check the connector at injector No.1 for a firm lock and clean contacts
    2. 2Measure the coil resistance of injector No.1 and compare it with the others
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Kubota SPN652-FMI3Injector No.2 harness coil - Open circuit

    Same open-coil fault as SPN 651, on the harness coil of injector No.2.· Shorted high
    Stop now

    Causes

    • Open wire or terminal at injector No.2
    • Injector No.2 coil open

    Checks

    1. 1Measure the coil resistance of injector No.2 against the other injectors.
    2. 2Check the lock and pins of the injector No.2 connector.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Kubota SPN653-FMI3Injector No.3 harness coil - Open circuit

    Same open-coil fault as SPN 651, on the harness coil of injector No.3.· Shorted high
    Stop now

    Causes

    • Open wire or terminal at injector No.3
    • Injector No.3 coil open

    Checks

    1. 1Measure the coil resistance of injector No.3 against the other injectors.
    2. 2Check the lock and pins of the injector No.3 connector.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Kubota SPN654-FMI3Injector No.4 harness coil - Open circuit

    Same open-coil fault as SPN 651, on the harness coil of injector No.4.· Shorted high
    Stop now

    Causes

    • Open wire or terminal at injector No.4
    • Injector No.4 coil open

    Checks

    1. 1Measure the coil resistance of injector No.4 against the other injectors.
    2. 2Check the lock and pins of the injector No.4 connector.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Kubota SPN723-FMI2Camshaft position sensor (G) - Short to battery

    SPN 723 FMI 2 means the camshaft position (G) sensor circuit is shorted to battery positive.· Erratic or implausible
    Stop now

    Causes

    • Wire chafed and touching a live supply wire
    • Failed camshaft position (G) sensor
    • Water inside the camshaft position (G) sensor connector

    Checks

    1. 1Unplug the camshaft position (G) sensor and check with the key on that the wire carries no voltage
    2. 2Follow the harness and look for rubbed insulation next to power wires
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • Kubota SPN723-FMI8Camshaft position sensor (G) - Open circuit or short to ground

    SPN 723 FMI 8 means the camshaft sensor signal is missing or abnormal.· Erratic or implausible
    Stop now

    Causes

    • Camshaft sensor failed
    • Sensor wire damaged near the timing cover
    • Debris on the sensor tip

    Checks

    1. 1Inspect the cam sensor and its connector for oil and looseness
    2. 2Measure the sensor resistance against the manual value
    3. 3Check the harness near the timing cover for chafing
    4. 4Compare cam and crank signals in Diagmaster during cranking
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • Kubota SPN1077-FMI12Injector drive IC error or open circuit

    SPN 1077 FMI 12 means the ECU chip that drives the injectors reports an internal fault or an open load.· Part or controller
    Stop now

    Causes

    • Open injector wiring
    • ECU driver chip failure
    • Low supply voltage

    Checks

    1. 1Check all four injector connectors and coil resistances
    2. 2Cycle the key and see whether the code returns at once
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Kubota E:9100Rpm sensor system error

    The engine speed or position signal (crankshaft or cam sensor) is bad.· Other
    Stop now

    Causes

    • Crankshaft position sensor failed or dirty
    • Camshaft position sensor failed
    • Sensor wires damaged or shorted
    • Damaged pulse wheel or wrong sensor gap

    Checks

    1. 1Inspect both sensors and connectors for oil, metal swarf and damage
    2. 2Measure sensor resistance against the service manual value
    3. 3Check the sensor harness for chafing against the engine block
    4. 4Look for the matching SPN 636 / 723 codes in Diagmaster
    5. 5Replace the failed sensor and confirm engine speed on the meter
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Kubota SPN523523-FMI3Injector No.1 and No.4 short to battery, or all injectors

    SPN 523523 FMI 3 means the drive wire of injectors 1 and 4, or of all injectors, is shorted to battery positive.· Shorted high
    Stop now

    Causes

    • Injector harness chafed and touching a live wire
    • Injector coil shorted to the supply
    • ECU injector driver damaged

    Checks

    1. 1Unplug the injectors one at a time and watch whether the code clears
    2. 2Check the injector harness for rubbed insulation next to power wires
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Kubota SPN523524-FMI3Injector No.2 and No.3 short to battery, or all injectors

    Same short-to-battery fault as SPN 523523, but on the drive wire shared by injectors 2 and 3 (or all injectors).· Shorted high
    Stop now

    Causes

    • Drive wire of injector 2 or 3 chafed onto a live wire
    • Injector 2 or 3 coil shorted to supply

    Checks

    1. 1Unplug injector 2, then injector 3, and note which one clears the code.
    2. 2Look for rubbed insulation on the 2 and 3 drive wires next to power wires.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Kubota SPN523525-FMI1Injector charge voltage low

    SPN 523525 FMI 1 means the injector firing capacitor does not reach its charge voltage.· Real condition
    Stop now

    Causes

    • Low battery or supply voltage to the ECU
    • Shorted injector loading the charge circuit
    • ECU internal fault

    Checks

    1. 1Measure the battery voltage while cranking
    2. 2Check the injector coil resistance for a shorted injector
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Kubota SPN523535-FMI0Injector charge voltage high

    SPN 523535 FMI 0 means the capacitor that fires the injectors is charging to too high a voltage.· Real condition
    Stop now

    Causes

    • ECU internal charging circuit fault
    • Injector circuit open so the charge cannot discharge
    • Poor ECU earth

    Checks

    1. 1Check for injector wiring codes and fix those first
    2. 2Check the ECU earth connections and supply voltage
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Kubota SPN523538-FMI2QR (IQA) data error

    SPN 523538 FMI 2 means the injector correction data is wrong.· Erratic or implausible
    Check soon

    Causes

    • Wrong data entered
    • ECU data corrupted
    • Injector replaced without update

    Checks

    1. 1Compare the stored codes with the injector codes
    2. 2Re-enter the codes in Diagmaster
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • Kubota SPN523538-FMI7No QR (IQA) data

    SPN 523538 FMI 7 means no injector correction data is stored.· Part or controller
    Check soon

    Causes

    • ECU replaced and not coded
    • Data lost
    • Injector replaced and not coded

    Checks

    1. 1Enter the injector codes in Diagmaster
    2. 2Check for other ECU memory codes
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Kubota SPN523605-FMI6Injector driver IC short circuit

    SPN 523605 FMI 6 means the ECU injector driver chip detects an over-current or short circuit on the injector output.· Shorted low
    Stop now

    Causes

    • Injector wiring shorted to ground
    • Injector coil shorted
    • ECU driver chip failure

    Checks

    1. 1Measure each injector coil resistance for a low reading
    2. 2Check the injector harness for a short to ground
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

Shared checks

Checks, in order

  1. 1Identify the injector named by the code in the firing order
  2. 2Check the battery voltage and the engine earth connections
  3. 3Read the stored injector codes in Diagmaster
  4. 4Check the sensor mounting bolt and the air gap at the pulse wheel
  5. 5Check the injector connector for corrosion and a firm lock
  6. 6Check the injector wiring and coil resistance of each injector
  7. 7Compare them with the codes printed on the injectors

Causes

  • Rpm sensor gap or wiring fault
  • Chafed injector harness under the valve cover
  • Faulty injector or injector wiring that loads the drive circuit
  • Injector correction codes not entered after replacement

Most common here: shorted high (6 of 18)

Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

When to stop

You'll notice: Rough running, misfire and white or black smoke, with the engine ECU lamp.

Common-rail fuel runs at very high pressure. Never open a high-pressure line or fitting with the engine running or just after it stops - a fine fuel jet can pierce skin.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.