EF Logo

Kubota · Engine ECU - SPN / FMI codes

Kubota EGR system and emission warnings fault codes

This page covers the exhaust gas recirculation valve and its position feedback, the E:9113 EGR valve error and the E:9115 emission level caution. The exhaust gas recirculation valve is moved by a small DC motor with a position sensor.

FaultCheckE:9113Kubota · EGR system and emission warnings
Code shows hereFAULTE:9113

Where this code shows

Watch the meter panel: a warning lamp comes on and the E: code scrolls on the display.

What do these codes mean?

Kubota codes E:9113 to SPN523578-FMI2 are all about the eGR system and emission warnings. The most common failure type is erratic or implausible (3 of 9); none needs an immediate stop. Start with this check: inspect the EGR valve for soot and free movement.

How urgent are they?

None of the 9 codes here means stop now; all 9 can wait until the shift ends, but find the cause before the next one.

  • Check soon9

What should I check first?

Inspect the EGR valve for soot and free movement

Shared checks

9 of 9

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Kubota E:9113EGR valve system error

    The EGR valve or its position sensor is out of range or stuck.· Other
    Check soon

    Causes

    • EGR actuator motor failed
    • EGR valve stuck with soot
    • Position sensor fault
    • Wiring to the EGR valve

    Checks

    1. 1Inspect the EGR valve for soot jamming and free movement
    2. 2Check the actuator wires and connector for damage and water
    3. 3Read the EGR commanded and actual position in Diagmaster
    4. 4Measure the actuator motor circuit resistance against the manual
    5. 5Clean or replace the EGR valve if it is stuck
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Kubota E:9115Emission level caution

    The ECU warns that exhaust emission levels are above the allowed limit.· Other
    Check soon

    Causes

    • EGR system fault
    • DPF or DOC fault
    • Injector fault
    • Sensor fault

    Checks

    1. 1Read all active engine codes in Diagmaster and deal with them in order
    2. 2Check the EGR valve and DOC for obvious problems and soot
    3. 3Check the exhaust temperature sensors read plausibly
    4. 4Verify the DPF is regenerating when it is requested
    5. 5Repair the underlying fault and retest the machine
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Kubota SPN523572-FMI4EGR position sensor failure

    SPN 523572 FMI 4 means the EGR valve position signal is out of range.· Shorted low
    Check soon

    Causes

    • Position sensor wire open or shorted
    • Sensor failed
    • Connector corrosion

    Checks

    1. 1Read the EGR position in Diagmaster while moving the valve
    2. 2Check the connector and wiring
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Kubota SPN523574-FMI3EGR actuator open circuit

    SPN 523574 FMI 3 means the EGR valve actuator circuit is open.· Shorted high
    Check soon

    Causes

    • Open wire to the EGR actuator
    • Actuator motor failed
    • Corroded connector

    Checks

    1. 1Check the actuator connector and wire continuity to the ECU
    2. 2Measure the motor winding resistance
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Kubota SPN523574-FMI4EGR actuator short circuit

    SPN 523574 FMI 4 means the EGR valve actuator circuit is shorted.· Shorted low
    Check soon

    Causes

    • Shorted actuator wire
    • Motor winding shorted
    • Water in the connector

    Checks

    1. 1Measure the motor winding resistance and the wire to ground
    2. 2Inspect the connector for water
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Kubota SPN523575-FMI7EGR valve stuck

    SPN 523575 FMI 7 means the EGR valve does not move to the commanded position.· Part or controller
    Check soon

    Causes

    • Soot build-up in the valve
    • Motor or gear failure
    • Blocked EGR cooler

    Checks

    1. 1Remove and inspect the valve for soot
    2. 2Command the valve in Diagmaster and watch whether it moves
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Kubota SPN523576-FMI2EGR DC motor overheat

    SPN 523576 FMI 2 means the EGR motor temperature is above the limit.· Erratic or implausible
    Check soon

    Causes

    • Blocked EGR cooler or coolant flow
    • Motor drawing high current from a sticking valve
    • Hot engine bay

    Checks

    1. 1Check the coolant flow to the EGR cooler
    2. 2Check the valve for sticking
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • Kubota SPN523577-FMI2EGR DC motor temperature sensor failure

    SPN 523577 FMI 2 means the temperature sensor inside the EGR motor gives an implausible value.· Erratic or implausible
    Check soon

    Causes

    • Sensor wire or connector fault
    • Sensor failed inside the actuator
    • Actuator internal fault

    Checks

    1. 1Check the actuator connector
    2. 2Read the motor temperature in Diagmaster against the engine temperature
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • Kubota SPN523578-FMI2No communication with EGR

    SPN 523578 FMI 2 means the ECU is not receiving messages from the EGR actuator.· Erratic or implausible
    Check soon

    Causes

    • Open CAN or supply wire to the actuator
    • Actuator failed
    • Corroded connector

    Checks

    1. 1Check the actuator supply and CAN wires
    2. 2Check the connector for water
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

Shared checks

Checks, in order

  1. 1Inspect the EGR valve for soot and free movement
  2. 2Check the connector and wiring for damage
  3. 3Command the valve in Diagmaster and watch the position
  4. 4Check the EGR cooler and pipes for blockage

Causes

  • EGR valve sticking from soot build-up
  • EGR valve sticking with soot
  • Motor or position sensor failed
  • Wiring or connector fault

Most common here: erratic or implausible (3 of 9)

Watch the live value on the service tool while you flex the harness and tap the connector.

When to stop

You'll notice: Reduced power, black smoke or a rough idle, with the engine ECU lamp.

Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?