EF Logo

Kubota · Engine ECU - SPN / FMI codes

Kubota ECU power, relays, sensor supply and starting aids fault codes

This page covers the electrical side of the engine ECU: supply and charging, battery voltage signal, the 5 V sensor supplies, the main and starter relays, the glow relay and air heater, and the starter turn-on limit. The engine ECU needs a steady battery voltage, a switched main relay and clean 5 V sensor supplies to run.

More about these parts

The engine ECU monitors the battery voltage on its supply pin. The engine ECU supplies three separate 5 V sensor supplies. The ECU main relay powers the engine ECU and the starter relay drive circuit cranks the engine. The engine ECU switches the glow plugs through a relay for cold starting.

FaultCheckSPN168-FMI3Kubota · ECU power, relays, sensor supply and starting aids
Code shows hereFAULTSPN168-FMI3

Where this code shows

Watch the meter panel: a warning lamp comes on and the E: code scrolls on the display.

What do these codes mean?

Kubota codes SPN168-FMI3 to SPN523544-FMI4 are all about the eCU power, relays, sensor supply and starting aids. The most common failure type is shorted low (6 of 20); 2 need an immediate stop. Start with this check: measure the battery voltage at rest and with the engine running.

How urgent are they?

2 of 20 codes here mean stop now; the other 18 can wait until the shift ends, but find the cause before the next one.

  • Stop now2
  • Check soon18

What should I check first?

Measure the battery voltage at rest and with the engine running

Shared checks

20 of 20

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Kubota SPN168-FMI3Battery voltage high

    SPN 168 FMI 3 means the ECU sees battery voltage above its range.· Shorted high
    Check soon

    Causes

    • Alternator regulator fault
    • Wrong charger or jump source
    • Loose sense wire at the alternator

    Checks

    1. 1Measure battery voltage with the engine running; a 12 V system should not exceed about 15 V
    2. 2Check the alternator regulator and its sense wire
    3. 3Find out how the machine was last jumped or charged
    4. 4Inspect the battery cables and terminals for loose or damaged connections
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Kubota SPN168-FMI4Battery voltage low

    SPN 168 FMI 4 means the ECU sees battery voltage below its working range.· Shorted low
    Check soon

    Causes

    • Discharged battery after a long idle or a stuck parasitic load
    • Alternator output wire loose at the stud
    • Ground strap between battery and frame corroded

    Checks

    1. 1With key on and engine off, measure battery voltage; a healthy 12 V battery reads about 12.4 V or more
    2. 2Crank the engine and watch the voltage dip; a sharp collapse while cranking means the battery or cables are weak
    3. 3Run the engine at fast idle and check the alternator output at its stud for a charging voltage
    4. 4Clean and tighten the battery terminals and the main ground strap to the frame
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Kubota SPN676-FMI0Glow heater relay drive circuit overheat

    SPN 676 FMI 0 means the ECU sees the glow relay drive circuit overheating.· Real condition
    Check soon

    Causes

    • Glow relay drawing too much current
    • Shorted glow plug
    • ECU driver overheating

    Checks

    1. 1Measure the current of each glow plug
    2. 2Check the relay and wiring for heat damage
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Kubota SPN676-FMI5Glow relay drive circuit - Open circuit

    SPN 676 FMI 5 means the glow relay drive circuit circuit is open.· Open circuit
    Check soon

    Causes

    • Broken wire or pulled-out terminal in the circuit
    • Failed glow relay drive circuit
    • Corroded connector

    Checks

    1. 1Check the wire for continuity from the glow relay drive circuit connector to the ECU
    2. 2Inspect the connector for corrosion and backed-out pins
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Kubota SPN677-FMI4Starter relay drive circuit - Short to ground

    SPN 677 FMI 4 means the starter relay drive circuit is shorted to ground.· Shorted low
    Check soon

    Causes

    • Drive wire touching ground
    • Relay coil shorted
    • ECU output fault

    Checks

    1. 1Measure the relay coil and the drive wire to ground
    2. 2Swap the relay with a known good one
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Kubota SPN1485-FMI2Main relay locked in closed position

    SPN 1485 FMI 2 means the ECU main relay stays closed after the key is switched off.· Erratic or implausible
    Stop now

    Causes

    • Main relay contacts welded
    • Relay drive wire shorted
    • Relay socket fault

    Checks

    1. 1Remove the relay with key off and check whether ECU power goes away
    2. 2Swap the main relay for a known good one and retest the key-off power
    3. 3Inspect the relay socket for heat damage and spread terminals
    4. 4Check the relay drive wire for a short to supply
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • Kubota SPN3509-FMI3Sensor supply voltage 1 high

    SPN 3509 FMI 3 means the 5 V sensor supply 1 is too high.· Shorted high
    Check soon

    Causes

    • Supply wire touching battery positive
    • ECU supply fault
    • Wiring damage

    Checks

    1. 1Measure supply 1 at a sensor connector with the key on
    2. 2Inspect the harness for contact with live wires
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Kubota SPN3509-FMI4Sensor supply voltage 1 low

    SPN 3509 FMI 4 means the 5 V sensor supply 1 is pulled low.· Shorted low
    Check soon

    Causes

    • Shorted sensor or wire on the supply line
    • Chafed harness
    • ECU supply fault

    Checks

    1. 1Measure supply 1 at a sensor connector and unplug sensors one by one
    2. 2Inspect the harness for chafing
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Kubota SPN3510-FMI3Sensor supply voltage 2 high

    Sensor supply 2 is too high, unlike the low reading of SPN 3510 FMI 4: its wire is likely touching a higher voltage.· Shorted high
    Check soon

    Causes

    • Supply 2 wire rubbed onto a battery feed
    • ECU supply 2 regulator fault

    Checks

    1. 1Key on, read supply 2; anything clearly above 5 V is a live contact.
    2. 2Trace the supply 2 wire for rubbed insulation near power cables.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Kubota SPN3510-FMI4Sensor supply voltage 2 low

    Sensor supply 2 is pulled low, as SPN 3509 does for supply 1; the sensors fed from supply 2 drop out together.· Shorted low
    Check soon

    Causes

    • A sensor on supply 2 shorted internally
    • Supply 2 wire pinched to ground

    Checks

    1. 1Back-probe supply 2 at one sensor, then unplug that sensor and re-measure.
    2. 2Repeat on each sensor until the voltage recovers.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Kubota SPN3511-FMI3Sensor supply voltage 3 high

    Sensor supply 3 is too high, the opposite of SPN 3511 FMI 4: its wire is likely touching a higher voltage.· Shorted high
    Check soon

    Causes

    • Supply 3 wire in contact with a battery feed
    • ECU supply 3 regulator fault

    Checks

    1. 1Key on, read supply 3 at a sensor plug and compare with supplies 1 and 2.
    2. 2Check the supply 3 wire where it runs beside power cables.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Kubota SPN3511-FMI4Sensor supply voltage 3 low

    Sensor supply 3 is pulled low, as SPN 3509 does for supply 1; sensors fed from supply 3 drop out together.· Shorted low
    Check soon

    Causes

    • A sensor on supply 3 shorted internally
    • Supply 3 wire pinched to ground

    Checks

    1. 1Back-probe supply 3 at one sensor, then unplug sensors in turn until it recovers.
    2. 2Look at the supply 3 harness where it bends or clamps.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Kubota E:9108Battery voltage system error

    The ECU sees battery voltage that is too low or too high.· Lost message
    Check soon

    Causes

    • Weak or sulfated battery
    • Alternator regulator fault
    • Loose or corroded battery terminals

    Checks

    1. 1Measure battery voltage at rest and with the engine running
    2. 2Clean and tighten the battery terminals and engine grounds
    3. 3Check the alternator output at the battery terminals under load
    4. 4Load test the battery or have it tested at a shop
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Kubota E:9109Sensor voltage system error

    One of the engine ECU's 5 V sensor supply lines is out of range.· Lost message
    Check soon

    Causes

    • Shorted sensor on the 5 V supply
    • Harness chafing to ground
    • Water in a sensor connector

    Checks

    1. 1Measure each 5 V sensor supply at the ECU connector with key on
    2. 2Unplug sensors one at a time to find the shorted one
    3. 3Inspect the harness for chafing and pinched sections
    4. 4Check connectors for water, oil and corrosion
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Kubota E:9110Main relay system error

    The relay that powers the engine ECU is faulty or sticking.· Lost message
    Stop now

    Causes

    • Main relay contacts stuck or burnt
    • Relay socket corroded
    • Open main relay fuse

    Checks

    1. 1Swap the main relay with a known good one of the same type
    2. 2Check the fuse and the relay socket terminals for heat damage
    3. 3Measure voltage at the ECU supply pins with key on and key off
    4. 4Check the relay coil resistance against its rating
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Kubota E:9117Air heater system error

    The intake air heater or glow circuit is open or shorted.· Open circuit
    Check soon

    Causes

    • Air heater element open
    • Relay failed
    • Wiring or fuse open
    • Controller output fault

    Checks

    1. 1Measure air heater current when commanded to heat
    2. 2Check the heater relay and its fuse for continuity
    3. 3Inspect the heater wiring and connector for burnt terminals
    4. 4Check the glow time and command in Diagmaster
    5. 5Replace the heater if its element is open circuit
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Kubota E:9119Charging system failure

    The alternator is not charging the battery to the expected voltage.· Other
    Check soon

    Causes

    • Alternator failed
    • Loose or slipping belt
    • Wiring or fuse fault

    Checks

    1. 1Measure charging voltage at the battery with the engine running
    2. 2Check the belt for glazing and correct tension
    3. 3Inspect the alternator wiring and fuse for damage
    4. 4Test the alternator output under load with a meter
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Kubota E:9310Starter turn-on limited

    The starter has been limited because it was cranked too often or too long.· Real condition
    Check soon

    Causes

    • Repeated cranking
    • Weak battery
    • Starter relay fault
    • No fuel

    Checks

    1. 1Wait several minutes before trying to start again
    2. 2Check the battery voltage dip while cranking; a weak battery prolongs each attempt
    3. 3Check the starter relay clicks cleanly and does not stay engaged
    4. 4Check there is fuel in the tank before cranking
    5. 5Try again once the starter and wiring have cooled down
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Kubota SPN523544-FMI3Glow relay drive circuit - Short to battery

    SPN 523544 FMI 3 means the glow relay drive circuit circuit is shorted to battery positive.· Shorted high
    Check soon

    Causes

    • Wire chafed and touching a live supply wire
    • Failed glow relay drive circuit
    • Water inside the glow relay drive circuit connector

    Checks

    1. 1Unplug the glow relay drive circuit and check with the key on that the wire carries no voltage
    2. 2Follow the harness and look for rubbed insulation next to power wires
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Kubota SPN523544-FMI4Glow relay drive circuit - Short to ground

    SPN 523544 FMI 4 means the glow relay drive circuit circuit is shorted to ground.· Shorted low
    Check soon

    Causes

    • Wire chafed through and touching the engine or frame
    • Failed glow relay drive circuit
    • Water inside the glow relay drive circuit connector

    Checks

    1. 1Unplug the glow relay drive circuit and measure the wire to ground with the key off; it should read open
    2. 2Follow the harness and look for chafed insulation at brackets and sleeves
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

Shared checks

Checks, in order

  1. 1Measure the battery voltage at rest and with the engine running
  2. 2Measure the battery voltage at rest and while running
  3. 3Measure each 5 V supply at the sensor connectors
  4. 4Swap the relay with a known good one of the same type
  5. 5Listen for the relay click when the key is turned on
  6. 6Check the battery terminals and the engine earth straps for tightness and corrosion
  7. 7Check the battery terminals and the engine earth strap for corrosion

Causes

  • Starter turn-on limited after repeated cranking
  • Loose or corroded battery terminals and earth straps
  • Weak battery or loose terminals
  • Shorted sensor on the supply line

Most common here: shorted low (6 of 20)

Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

When to stop

You'll notice: Several warning lamps at once, hard starting or the engine stopping, with the E:91xx code.

Most sensor and wiring faults can be traced with a multimeter and the wiring diagram. Disconnect the battery before unplugging controllers; if the controller itself is suspect or needs programming, that needs the dealer’s service tool.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.