EF Logo

Kubota · DPF regeneration (E:90xx)

Kubota DPF, regeneration and particulate accumulation fault codes

This page covers the diesel particulate filter: regeneration messages and faults, parked regeneration and the overheat precaution, the differential pressure sensor, particulate matter accumulation levels and DPF removal detection. The diesel particulate filter collects soot and burns it off in a regeneration.

More about these parts

These codes show that a regeneration did not run as planned: the catalyst did not heat the exhaust, the regeneration took too long, it stopped because the engine was too cold, or it is happening too often. These codes show that a parked regeneration was stopped because the coolant was too cold or it took too long, that regenerations happen too often, or that the engine is nearing overheat. The differential pressure sensor measures the pressure drop across the particulate filter to estimate soot load. The engine ECU estimates the soot load of the particulate filter. The engine ECU checks that the particulate filter is fitted and working.

FaultStopE:9004Kubota · DPF, regeneration and particulate accumulation
Code shows hereFAULTE:9004

Where this code shows

Watch the meter panel: a warning lamp comes on and the E: code scrolls on the display.

What do these codes mean?

Kubota codes SPN3251-FMI3 to SPN523603-FMI15 are all about the dPF, regeneration and particulate accumulation. The most common failure type is real condition (7 of 24); 3 need an immediate stop. Start with this check: read the message and check whether the regeneration inhibit switch is off.

How urgent are they?

3 of 24 codes here mean stop now; 20 can wait until the shift ends, but find the cause before the next one; 1 is information only.

  • Stop now3
  • Check soon20
  • Info1

What should I check first?

Read the message and check whether the regeneration inhibit switch is off

Shared checks

24 of 24

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Kubota SPN3251-FMI3DPF differential pressure sensor - Open circuit or short to battery

    SPN 3251 FMI 3 means the DPF differential pressure sensor reads above range or is open.· Shorted high
    Check soon

    Causes

    • Sensor failed high
    • Signal wire open or shorted to supply
    • Blocked pressure hose

    Checks

    1. 1Read the sensor at key on engine off; a high reading with no pressure confirms a high-side fault
    2. 2Check the signal wire for a short to supply or an open
    3. 3Blow through the pressure hoses and check for soot plugs
    4. 4Inspect the differential pressure sensor connector for water ingress
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Kubota SPN3251-FMI4DPF differential pressure sensor - Ground short

    SPN 3251 FMI 4 means the DPF differential pressure sensor reads below range, usually an open or grounded signal.· Shorted low
    Check soon

    Causes

    • Sensor failed low
    • Signal wire shorted to ground
    • Hose or fitting problem

    Checks

    1. 1Read the sensor at key on engine off; it should sit near zero
    2. 2Check the differential pressure sensor signal wire for a short to ground
    3. 3Inspect the pressure hoses for cracks and kinks
    4. 4Check the sensor connector for water ingress and bent pins
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Kubota SPN3701-FMI0PM accumulation level 5

    SPN 3701 FMI 0 means soot accumulation in the particulate filter has reached level 5.· Real condition
    Stop now

    Causes

    • Regeneration not completing
    • Sensor fault hiding the real load
    • Engine running at light load

    Checks

    1. 1Run a parked regeneration as the manual describes
    2. 2Read the differential pressure and soot level in Diagmaster
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Kubota SPN3701-FMI15PM accumulation level 3

    SPN 3701 FMI 15 means soot accumulation in the particulate filter has reached level 3.· Real condition
    Check soon

    Causes

    • Regeneration not completing
    • Sensor fault hiding the real load
    • Engine running at light load

    Checks

    1. 1Run a parked regeneration as the manual describes
    2. 2Read the differential pressure and soot level in Diagmaster
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Kubota SPN3701-FMI16PM accumulation level 4

    SPN 3701 FMI 16 means soot accumulation in the particulate filter has reached level 4.· Real condition
    Check soon

    Causes

    • Regeneration not completing
    • Sensor fault hiding the real load
    • Engine running at light load

    Checks

    1. 1Run a parked regeneration as the manual describes
    2. 2Read the differential pressure and soot level in Diagmaster
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Kubota SPN3936-FMI2Loss of function of DPF (PCD)

    SPN 3936 FMI 2 means the particulate filter no longer performs as expected.· Erratic or implausible
    Check soon

    Causes

    • Filter cracked or melted
    • Exhaust leak before the filter
    • Sensor fault

    Checks

    1. 1Inspect the filter for damage
    2. 2Read the differential pressure and compare with the soot estimate
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • Kubota SPN3936-FMI7Removal of DPF (PCD)

    SPN 3936 FMI 7 means the ECU believes the particulate filter has been removed.· Part or controller
    Check soon

    Causes

    • Filter removed or substituted
    • Differential pressure hoses leaking or off
    • Sensor fault

    Checks

    1. 1Confirm the filter is fitted
    2. 2Check the pressure hoses and sensor
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Kubota E:9000DPF regeneration required (low rpm prevents start)

    Soot has built up in the diesel particulate filter and the engine needs a regeneration, but engine speed is too low for it to begin.· Lost message
    Check soon

    Causes

    • Engine run at low idle for long periods so the filter never gets hot
    • Short runs that never reach regeneration temperature
    • Regeneration inhibit switch left on
    • Soot load rising because of an engine or sensor fault

    Checks

    1. 1Confirm the DPF inhibit switch is off and the machine has fuel and normal coolant temperature
    2. 2Raise engine speed and start a parked regeneration with the DPF switch as described in the operator's manual
    3. 3Watch the exhaust temperature rise and the code clear when the regeneration completes
    4. 4Read differential pressure and exhaust temperatures in Diagmaster to see how loaded the filter is
    5. 5If it repeats, check for air intake restriction and exhaust temperature sensor faults
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Kubota E:9001DPF regeneration required

    The controller requests a DPF regeneration because soot is accumulating.· Lost message
    Check soon

    Causes

    • Regeneration not performed as scheduled
    • Frequent idling or light duty keeping exhaust cool
    • Differential pressure sensor misreading soot load
    • Regeneration blocked by the inhibit switch

    Checks

    1. 1Start a manual regeneration with the DPF switch while the loader is parked and level
    2. 2Confirm the exhaust temperature sensors read sensibly against each other
    3. 3Check the DPF differential pressure hoses for kinks, cracks and soot blockage
    4. 4Check that no other engine codes are preventing regeneration
    5. 5Work the machine under load next shift to avoid repeat requests
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Kubota E:9002DPF regenerated

    The controller reports that the particulate filter has just been regenerated.· Other
    Info

    Causes

    • Normal completion of an automatic regeneration
    • Manual regeneration started by the operator
    • Scheduled soot burn-off finishing

    Checks

    1. 1Confirm the DPF lamp has gone off after the regeneration finished
    2. 2Let the engine idle briefly before shutdown if the operator's manual asks for it
    3. 3Note how often regenerations happen so a developing problem shows up early
    4. 4If regenerations come very often, check for E:9214 and the differential pressure sensor
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Kubota E:9003DPF regeneration required (cannot start)

    The DPF needs regeneration but conditions such as low coolant temperature or an inhibit condition stop it from starting.· Other
    Check soon

    Causes

    • Coolant not warm enough to allow regeneration
    • Regeneration inhibit switch active
    • Exhaust temperature sensor fault blocking regeneration

    Checks

    1. 1Warm the engine until coolant reaches operating temperature, then retry
    2. 2Make sure the inhibit switch is off and its circuit is not shorted
    3. 3Read the exhaust temperature sensor values and check they are plausible
    4. 4Check for stored E:9203 and E:9205 to E:9208 codes
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Kubota E:9004DPF replacement required

    The particulate filter is so loaded with ash and soot that regeneration cannot restore it.· Other
    Stop now

    Causes

    • Filter loaded with ash beyond what regeneration can burn
    • Long period of unsuccessful regenerations
    • Engine fault pushing excess soot into the exhaust
    • Cracked or melted DPF substrate

    Checks

    1. 1Review history for repeated failed regenerations
    2. 2Read the DPF differential pressure at idle and compare it with a known good machine
    3. 3Inspect the exhaust inlet and outlet for soot and heat damage
    4. 4Have the DPF cleaned or replaced by a Kubota dealer
    5. 5Reset the soot counters with Diagmaster after the service
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Kubota E:9006DPF regeneration required (inhibit switch active)

    A regeneration is needed but the regeneration inhibit switch is on, so the loader will not burn off the soot.· Other
    Check soon

    Causes

    • DPF inhibit switch left on
    • Inhibit switch circuit shorted
    • Operator working where regeneration must be avoided

    Checks

    1. 1Check the position of the inhibit switch on the dash and the lamp beside it
    2. 2Test the switch contacts with a meter in both positions
    3. 3Check the switch wires for a short to ground or to the supply
    4. 4Turn inhibit off and start a parked regeneration as the manual describes
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Kubota E:9007DPF regeneration required (inhibit switch active, engine may stop)

    A regeneration is needed but cannot start because the inhibit switch is on.· Lost message
    Check soon

    Causes

    • Regeneration inhibit switch left on
    • Machine parked with the hydraulics locked
    • Soot load rising unnoticed

    Checks

    1. 1Release the inhibit switch and restart the engine
    2. 2Start the regeneration as the manual describes
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Kubota E:9010Engine stop for DPF

    The engine control unit stops the engine to protect the exhaust system because the DPF is dangerously loaded or too hot.· Other
    Stop now

    Causes

    • DPF soot load beyond limit after ignored warnings
    • DPF overheating
    • Failed regeneration cycles

    Checks

    1. 1Check the stored DPF codes and earlier warnings to see how the soot load got there
    2. 2Inspect the DPF and exhaust pipes for heat damage and soot leakage
    3. 3Have the soot level and differential pressure read in Diagmaster
    4. 4Perform a service regeneration or replace the DPF at a Kubota dealer
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Kubota E:9204Differential pressure sensor system error

    The sensor that measures pressure drop across the DPF is reporting a bad value, so the ECU cannot judge soot load.· Other
    Check soon

    Causes

    • Differential pressure sensor failed
    • Cracked or blocked pressure hoses to the DPF
    • Wiring fault at the sensor
    • Exhaust leak at a pipe fitting

    Checks

    1. 1Inspect both pressure hoses and their fittings for cracks, soot plugs and loose clamps
    2. 2Read differential pressure at key on engine off; it should be near zero
    3. 3Back-probe supply, ground and signal at the sensor
    4. 4Check the exhaust joints for leaks near the DPF
    5. 5Replace the sensor if the reading will not settle near zero with the engine off
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Kubota E:9211DOC response unusual

    The oxidation catalyst is not heating the exhaust as expected when fuel is dosed.· Lost message
    Check soon

    Causes

    • DOC catalyst degraded or coated with soot
    • Fuel dosing problem
    • Exhaust sensor reading wrong

    Checks

    1. 1Review stored DPF codes and regeneration history in Diagmaster
    2. 2Compare the exhaust temperatures during a regeneration
    3. 3Check the injectors and fuel supply for faults
    4. 4Inspect the air intake and cleaner for restriction that would starve the burn
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Kubota E:9212DPF regeneration timeout

    A regeneration started but did not finish within the allowed time.· Lost message
    Check soon

    Causes

    • Engine shut down during the regeneration
    • Low exhaust temperature
    • Regeneration interrupted by load changes

    Checks

    1. 1Allow the regeneration to finish with the machine parked and idling
    2. 2Check the exhaust temperature sensors read plausibly
    3. 3Check the intake throttle valve moves freely and is not choked with soot
    4. 4Look for other active codes blocking the regeneration
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Kubota E:9213DPF regeneration error (water temperature low)

    Regeneration was stopped because the coolant temperature was too low.· Lost message
    Check soon

    Causes

    • Engine not warm
    • Thermostat stuck open
    • Coolant temperature sensor fault

    Checks

    1. 1Warm the engine fully before starting a regeneration
    2. 2Check that the thermostat closes and opens properly
    3. 3Compare the coolant temperature display with a thermometer
    4. 4Check the coolant level in the radiator, since low coolant can show cold readings
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Kubota E:9214DPF regeneration cycle occurs too often

    Regeneration is happening more often than normal, which points to excess soot production or a faulty sensor.· Other
    Check soon

    Causes

    • Differential pressure sensor misreading
    • Engine making too much soot
    • DOC or DPF damaged
    • Air or fuel system fault

    Checks

    1. 1Check the differential pressure sensor and its hoses
    2. 2Check the air intake and injectors for faults
    3. 3Review the regeneration history in Diagmaster
    4. 4Inspect the DPF for cracks and heavy ash build-up with the dealer's help
    5. 5Repair whatever is making the extra soot before it damages the filter
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Kubota SPN523589-FMI17Low coolant temperature in parked regeneration

    SPN 523589 FMI 17 means a parked regeneration was stopped because the coolant stayed too cold.· Real condition
    Check soon

    Causes

    • Thermostat stuck open
    • Cold ambient conditions
    • Coolant sensor reading low

    Checks

    1. 1Warm the engine up to operating temperature before starting the regeneration
    2. 2Check the thermostat operation
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Kubota SPN523590-FMI16Parked regeneration time out

    SPN 523590 FMI 16 means the parked regeneration took longer than allowed.· Real condition
    Check soon

    Causes

    • Exhaust sensor or catalyst fault
    • Very high soot load
    • Cold engine

    Checks

    1. 1Check for sensor codes first
    2. 2Repeat the regeneration after the engine is warm
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Kubota SPN523602-FMI0High frequency of regeneration

    SPN 523602 FMI 0 means regenerations happen more often than normal.· Real condition
    Check soon

    Causes

    • Injector or air supply fault
    • Oil in the exhaust
    • Sensor fault

    Checks

    1. 1Check for sensor and injector codes
    2. 2Check the oil level and consumption
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Kubota SPN523603-FMI15Overheat pre-caution

    SPN 523603 FMI 15 means the engine is approaching an overheat condition.· Real condition
    Check soon

    Causes

    • Blocked cooler
    • Low coolant
    • Fan problem

    Checks

    1. 1Clean the cooler and check the coolant level
    2. 2Check the fan operation
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

Shared checks

Checks, in order

  1. 1Read the message and check whether the regeneration inhibit switch is off
  2. 2Check for other active engine and sensor codes and fix those first
  3. 3Check the coolant temperature reaches the normal working range
  4. 4Inspect both pressure hoses for blockage and cracks
  5. 5Run the regeneration as the operator's manual describes
  6. 6Inspect the exhaust system to confirm the filter is fitted
  7. 7Move the machine to a safe open area and start the regeneration as the operator's manual describes

Causes

  • Differential pressure sensor hose blocked or sensor failed
  • Long periods of idling or light load that never reach regeneration temperature
  • Exhaust temperature or differential pressure sensor fault
  • Cold coolant from a stuck-open thermostat

Most common here: real condition (7 of 24)

Check the real value with a separate gauge or thermometer before blaming the sensor.

When to stop

You'll notice: A DPF lamp and an E:90xx message on the meter; the engine may be limited in power until the regeneration is done.

Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.