EF Logo

Komatsu · Monitor service codes

Komatsu Service codes: sensors, inputs and system (E1xx, E2xx, E3xx) fault codes

This family lists the other service codes of the older PC200-6/PC300-6/PC400-6 and PC200-7 machines: fault history, clock, buzzer, air filter, coolant temperature, wiper, mode selection, network, pressure and speed sensors, fuel dial and governor motor. They show only in service mode.

FaultInfoE101Komatsu · Service codes: sensors, inputs and system (E1xx, E2xx, E3xx)
Code shows hereFAULTE101

Where this code shows

Watch the monitor for the user code and the caution lamp or buzzer, and write the code down.

What do these codes mean?

Komatsu codes E101 to E318 are all about the service codes: sensors, inputs and system (E1xx, E2xx, E3xx). The most common failure type is short circuit (4 of 21); none needs an immediate stop. Start with this check: read the service code in the fault history and find the matching circuit.

How urgent are they?

None of the 21 codes here means stop now; 18 can wait until the shift ends, but find the cause before the next one; 3 are information only.

  • Check soon18
  • Info3

What should I check first?

Read the service code in the fault history and find the matching circuit

Shared checks

21 of 21

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Komatsu E101Fault history record abnormal

    The fault history stored in the monitor is corrupt, so past faults cannot be read reliably.· Other
    Info

    Causes

    • Monitor memory fault
    • Power lost while the history was being written

    Checks

    1. 1Clear the history and see whether the code returns
    2. 2Check monitor supply
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Komatsu E102Clock data abnormal

    The monitor clock holds invalid data, so the time stamps on faults are unreliable.· Other
    Info

    Causes

    • Monitor clock battery or memory fault
    • Monitor supply interruption

    Checks

    1. 1Reset the clock in the monitor
    2. 2Replace the monitor if it keeps failing
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Komatsu E103Buzzer output short circuit

    The buzzer drive wire is touching the 24 V line, so the buzzer output is overloaded.· Short circuit
    Check soon

    Causes

    • Buzzer wire touching a 24 V feed
    • Failed buzzer

    Checks

    1. 1Check the buzzer wire for contact with a power line
    2. 2Test the buzzer
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the part and the controller. Measure from the output wire to ground and to battery positive, then across the part.

    Good: Open circuit (OL) to ground and to supply; the part reads its listed resistance, not near 0 Ω.

  • Komatsu E104Air filter clogged

    The air filter restriction signal reports the air cleaner as clogged.· Real condition
    Check soon

    Causes

    • Dirty air filter element
    • Restriction switch fault

    Checks

    1. 1Clean or replace the air filter element
    2. 2Check the restriction switch
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Komatsu E108Coolant temperature above 105

    The coolant temperature signal went above 105 (the source gives no unit, normally degrees C).· Real condition
    Check soon

    Causes

    • Radiator or cooler blocked
    • Fan or fan belt problem
    • Coolant sensor fault

    Checks

    1. 1Check the radiator and fan operation
    2. 2Compare the monitor temperature with a thermometer
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Komatsu E112Wiper motor forward drive short circuit

    The wiper motor forward drive circuit is shorted, so the wiper will not run forward.· Short circuit
    Check soon

    Causes

    • Wiper motor shorted
    • Wire touching ground

    Checks

    1. 1Check the wiper motor and wiring
    2. 2Check the wiper fuse
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the part and the controller. Measure from the output wire to ground and to battery positive, then across the part.

    Good: Open circuit (OL) to ground and to supply; the part reads its listed resistance, not near 0 Ω.

  • Komatsu E113Wiper motor reverse drive short circuit

    The wiper motor reverse drive circuit is shorted, so the wiper will not run in reverse.· Short circuit
    Check soon

    Causes

    • Wiper motor shorted
    • Wire touching ground

    Checks

    1. 1Check the wiper motor and wiring
    2. 2Check the wiper fuse
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the part and the controller. Measure from the output wire to ground and to battery positive, then across the part.

    Good: Open circuit (OL) to ground and to supply; the part reads its listed resistance, not near 0 Ω.

  • Komatsu E114Washer drive short circuit

    The washer drive circuit is shorted, so the washer will not work.· Short circuit
    Check soon

    Causes

    • Washer pump shorted
    • Wire touching ground

    Checks

    1. 1Check the washer pump and wiring
    2. 2Check the washer fuse
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the part and the controller. Measure from the output wire to ground and to battery positive, then across the part.

    Good: Open circuit (OL) to ground and to supply; the part reads its listed resistance, not near 0 Ω.

  • Komatsu E217Mode selection input failure

    The work mode selection input is abnormal, so the machine may not change mode.· Other
    Check soon

    Causes

    • Mode switch fault
    • Switch wiring damaged

    Checks

    1. 1Check the mode switch and its connector
    2. 2Test the switch in each position
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Komatsu E218Network response timeout

    A controller did not answer on the network within the allowed time.· Lost message
    Check soon

    Causes

    • Data link wire damaged
    • Controller without power

    Checks

    1. 1Check the data link wires and connectors
    2. 2Check the controller supply
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Komatsu E224Front pump pressure sensor circuit abnormal

    The front pump pressure sensor circuit is abnormal, so the pump controller may mis-set the pump.· Other
    Check soon

    Causes

    • Sensor connector wet or loose
    • Sensor wire damaged

    Checks

    1. 1Check the front pump pressure sensor connector
    2. 2Measure the sensor supply and signal
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Komatsu E225Rear pump pressure sensor circuit abnormal

    The rear pump pressure sensor circuit is abnormal, so the pump controller may mis-set the pump.· Other
    Check soon

    Causes

    • Sensor connector wet or loose
    • Sensor wire damaged

    Checks

    1. 1Check the rear pump pressure sensor connector
    2. 2Measure the sensor supply and signal
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Komatsu E226Pressure sensor power supply abnormal

    The supply to the pressure sensors is abnormal, so every pressure reading may be wrong.· Other
    Check soon

    Causes

    • A shorted pressure sensor
    • Supply wire damaged

    Checks

    1. 1Unplug the sensors one by one and watch the supply
    2. 2Check the supply wire
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Komatsu E227Engine speed sensor abnormal

    The engine speed sensor signal is abnormal, so the controller cannot track speed.· Other
    Check soon

    Causes

    • Sensor connector loose
    • Sensor gap or wiring damaged

    Checks

    1. 1Check the speed sensor connector and wiring
    2. 2Measure the sensor resistance
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Komatsu E306Feedback potentiometer circuit abnormal

    The feedback potentiometer circuit is abnormal, so the governor position is not reported correctly.· Other
    Check soon

    Causes

    • Potentiometer fault
    • Wire open

    Checks

    1. 1Check the potentiometer wiring
    2. 2Measure the potentiometer signal
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Komatsu E308Fuel dial input abnormal

    The fuel dial input is abnormal, so engine speed may not follow the dial.· Other
    Check soon

    Causes

    • Fuel dial fault
    • Dial wiring damaged

    Checks

    1. 1Check the fuel dial wiring
    2. 2Turn the dial and watch the signal
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Komatsu E313Automatic grease supply controller malfunction (optional)

    The optional automatic grease supply controller reports a malfunction.· Other
    Info

    Causes

    • Grease controller fault
    • Pump or wiring fault

    Checks

    1. 1Check the grease controller supply
    2. 2Check the grease pump wiring
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Komatsu E315Battery relay output circuit short

    The battery relay output circuit is shorted, so the battery relay may not work.· Other
    Check soon

    Causes

    • Relay coil shorted
    • Wire touching ground

    Checks

    1. 1Check the battery relay and wiring
    2. 2Measure the relay coil
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Komatsu E316Governor motor out of adjustment

    The governor motor is out of adjustment, so the engine speed does not match the dial.· Other
    Check soon

    Causes

    • Governor linkage out of adjustment
    • Governor motor worn

    Checks

    1. 1Check the linkage adjustment
    2. 2Run the governor adjustment in service mode
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Komatsu E317Governor motor circuit open

    The governor motor circuit is open, so the motor cannot move.· Open circuit
    Check soon

    Causes

    • Governor motor open
    • Wire broken

    Checks

    1. 1Check the governor motor wiring
    2. 2Measure the motor resistance
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Komatsu E318Governor motor circuit short

    The governor motor circuit is shorted, so the output is cut.· Other
    Check soon

    Causes

    • Governor motor shorted
    • Wire touching ground

    Checks

    1. 1Check the governor motor wiring
    2. 2Measure the motor resistance
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

Shared checks

Checks, in order

  1. 1Read the service code in the fault history and find the matching circuit
  2. 2Check the sensor or actuator connector for water and corrosion
  3. 3Measure the supply, ground and signal wires at the connector
  4. 4Compare the reading with a trusted gauge or the other side
  5. 5Clear the history and see whether the code returns

Causes

  • Sensor or switch connector loose or corroded
  • Wiring open or shorted
  • Failed sensor or actuator
  • Controller or monitor fault

Most common here: short circuit (4 of 21)

Key off, unplug the part and the controller. Measure from the output wire to ground and to battery positive, then across the part.

When to stop

You'll notice: The machine may run normally, but a sensor, buzzer, wiper or governor function is wrong; the code is read from the service mode fault history.

Let the engine cool before opening the cooling system; a hot cap releases scalding coolant. Running on with an overheat warning risks a head gasket or seized engine.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.