Komatsu · Monitor service codes
Komatsu Service codes: sensors, inputs and system (E1xx, E2xx, E3xx) fault codes
This family lists the other service codes of the older PC200-6/PC300-6/PC400-6 and PC200-7 machines: fault history, clock, buzzer, air filter, coolant temperature, wiper, mode selection, network, pressure and speed sensors, fuel dial and governor motor. They show only in service mode.
Where this code shows
Watch the monitor for the user code and the caution lamp or buzzer, and write the code down.
What do these codes mean?
Komatsu codes E101 to E318 are all about the service codes: sensors, inputs and system (E1xx, E2xx, E3xx). The most common failure type is short circuit (4 of 21); none needs an immediate stop. Start with this check: read the service code in the fault history and find the matching circuit.
How urgent are they?
None of the 21 codes here means stop now; 18 can wait until the shift ends, but find the cause before the next one; 3 are information only.
- Check soon18
- Info3
What should I check first?
Read the service code in the fault history and find the matching circuit
Shared checks21 of 21
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
Komatsu E101Fault history record abnormal
The fault history stored in the monitor is corrupt, so past faults cannot be read reliably.· OtherOtherInfoCauses
- Monitor memory fault
- Power lost while the history was being written
Checks
- 1Clear the history and see whether the code returns
- 2Check monitor supply
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Komatsu E102Clock data abnormal
The monitor clock holds invalid data, so the time stamps on faults are unreliable.· OtherOtherInfoCauses
- Monitor clock battery or memory fault
- Monitor supply interruption
Checks
- 1Reset the clock in the monitor
- 2Replace the monitor if it keeps failing
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Komatsu E103Buzzer output short circuit
The buzzer drive wire is touching the 24 V line, so the buzzer output is overloaded.· Short circuitShort circuitCheck soonCauses
- Buzzer wire touching a 24 V feed
- Failed buzzer
Checks
- 1Check the buzzer wire for contact with a power line
- 2Test the buzzer
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the part and the controller. Measure from the output wire to ground and to battery positive, then across the part.
Good: Open circuit (OL) to ground and to supply; the part reads its listed resistance, not near 0 Ω.
Komatsu E104Air filter clogged
The air filter restriction signal reports the air cleaner as clogged.· Real conditionReal conditionCheck soonCauses
- Dirty air filter element
- Restriction switch fault
Checks
- 1Clean or replace the air filter element
- 2Check the restriction switch
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Komatsu E108Coolant temperature above 105
The coolant temperature signal went above 105 (the source gives no unit, normally degrees C). Overheating is possible.· Real conditionReal conditionCheck soonCauses
- Radiator or cooler blocked
- Fan or fan belt problem
- Coolant sensor fault
Checks
- 1Check the radiator and fan operation
- 2Compare the monitor temperature with a thermometer
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Komatsu E112Wiper motor forward drive short circuit
The wiper motor forward drive circuit is shorted, so the wiper will not run forward.· Short circuitShort circuitCheck soonCauses
- Wiper motor shorted
- Wire touching ground
Checks
- 1Check the wiper motor and wiring
- 2Check the wiper fuse
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the part and the controller. Measure from the output wire to ground and to battery positive, then across the part.
Good: Open circuit (OL) to ground and to supply; the part reads its listed resistance, not near 0 Ω.
Komatsu E113Wiper motor reverse drive short circuit
The wiper motor reverse drive circuit is shorted, so the wiper will not run in reverse.· Short circuitShort circuitCheck soonCauses
- Wiper motor shorted
- Wire touching ground
Checks
- 1Check the wiper motor and wiring
- 2Check the wiper fuse
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the part and the controller. Measure from the output wire to ground and to battery positive, then across the part.
Good: Open circuit (OL) to ground and to supply; the part reads its listed resistance, not near 0 Ω.
Komatsu E114Washer drive short circuit
The washer drive circuit is shorted, so the washer will not work.· Short circuitShort circuitCheck soonCauses
- Washer pump shorted
- Wire touching ground
Checks
- 1Check the washer pump and wiring
- 2Check the washer fuse
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the part and the controller. Measure from the output wire to ground and to battery positive, then across the part.
Good: Open circuit (OL) to ground and to supply; the part reads its listed resistance, not near 0 Ω.
Komatsu E217Mode selection input failure
The work mode selection input is abnormal, so the machine may not change mode.· OtherOtherCheck soonCauses
- Mode switch fault
- Switch wiring damaged
Checks
- 1Check the mode switch and its connector
- 2Test the switch in each position
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Komatsu E218Network response timeout
A controller did not answer on the network within the allowed time.· Lost messageLost messageCheck soonCauses
- Data link wire damaged
- Controller without power
Checks
- 1Check the data link wires and connectors
- 2Check the controller supply
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Komatsu E224Front pump pressure sensor circuit abnormal
The front pump pressure sensor circuit is abnormal, so the pump controller may mis-set the pump.· OtherOtherCheck soonCauses
- Sensor connector wet or loose
- Sensor wire damaged
Checks
- 1Check the front pump pressure sensor connector
- 2Measure the sensor supply and signal
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Komatsu E225Rear pump pressure sensor circuit abnormal
The rear pump pressure sensor circuit is abnormal, so the pump controller may mis-set the pump.· OtherOtherCheck soonCauses
- Sensor connector wet or loose
- Sensor wire damaged
Checks
- 1Check the rear pump pressure sensor connector
- 2Measure the sensor supply and signal
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Komatsu E226Pressure sensor power supply abnormal
The supply to the pressure sensors is abnormal, so every pressure reading may be wrong.· OtherOtherCheck soonCauses
- A shorted pressure sensor
- Supply wire damaged
Checks
- 1Unplug the sensors one by one and watch the supply
- 2Check the supply wire
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Komatsu E227Engine speed sensor abnormal
The engine speed sensor signal is abnormal, so the controller cannot track speed.· OtherOtherCheck soonCauses
- Sensor connector loose
- Sensor gap or wiring damaged
Checks
- 1Check the speed sensor connector and wiring
- 2Measure the sensor resistance
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Komatsu E306Feedback potentiometer circuit abnormal
The feedback potentiometer circuit is abnormal, so the governor position is not reported correctly.· OtherOtherCheck soonCauses
- Potentiometer fault
- Wire open
Checks
- 1Check the potentiometer wiring
- 2Measure the potentiometer signal
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Komatsu E308Fuel dial input abnormal
The fuel dial input is abnormal, so engine speed may not follow the dial.· OtherOtherCheck soonCauses
- Fuel dial fault
- Dial wiring damaged
Checks
- 1Check the fuel dial wiring
- 2Turn the dial and watch the signal
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Komatsu E313Automatic grease supply controller malfunction (optional)
The optional automatic grease supply controller reports a malfunction.· OtherOtherInfoCauses
- Grease controller fault
- Pump or wiring fault
Checks
- 1Check the grease controller supply
- 2Check the grease pump wiring
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Komatsu E315Battery relay output circuit short
The battery relay output circuit is shorted, so the battery relay may not work.· OtherOtherCheck soonCauses
- Relay coil shorted
- Wire touching ground
Checks
- 1Check the battery relay and wiring
- 2Measure the relay coil
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Komatsu E316Governor motor out of adjustment
The governor motor is out of adjustment, so the engine speed does not match the dial.· OtherOtherCheck soonCauses
- Governor linkage out of adjustment
- Governor motor worn
Checks
- 1Check the linkage adjustment
- 2Run the governor adjustment in service mode
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Komatsu E317Governor motor circuit open
The governor motor circuit is open, so the motor cannot move.· Open circuitOpen circuitCheck soonCauses
- Governor motor open
- Wire broken
Checks
- 1Check the governor motor wiring
- 2Measure the motor resistance
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Komatsu E318Governor motor circuit short
The governor motor circuit is shorted, so the output is cut.· OtherOtherCheck soonCauses
- Governor motor shorted
- Wire touching ground
Checks
- 1Check the governor motor wiring
- 2Measure the motor resistance
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Shared checks
Checks, in order
- 1Read the service code in the fault history and find the matching circuit
- 2Check the sensor or actuator connector for water and corrosion
- 3Measure the supply, ground and signal wires at the connector
- 4Compare the reading with a trusted gauge or the other side
- 5Clear the history and see whether the code returns
Causes
- Sensor or switch connector loose or corroded
- Wiring open or shorted
- Failed sensor or actuator
- Controller or monitor fault
Most common here: short circuit (4 of 21)
Key off, unplug the part and the controller. Measure from the output wire to ground and to battery positive, then across the part.
When to stop
You'll notice: The machine may run normally, but a sensor, buzzer, wiper or governor function is wrong; the code is read from the service mode fault history.
Let the engine cool before opening the cooling system; a hot cap releases scalding coolant. Running on with an overheat warning risks a head gasket or seized engine.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.