FaultCheckE202Komatsu · Service codes: solenoid circuits (E2xx, E3xx)
Code shows hereFAULTE202

Where this code shows

Watch the monitor for the user code and the caution lamp or buzzer, and write the code down.

What do these codes mean?

Komatsu codes E202 to E303 are all about the service codes: solenoid circuits (E2xx, E3xx). The most common failure type is open circuit (10 of 21); none needs an immediate stop. Start with this check: inspect the solenoid connector for water and corrosion.

How urgent are they?

None of the 21 codes here means stop now; all 21 can wait until the shift ends, but find the cause before the next one.

  • Check soon21

What should I check first?

Inspect the solenoid connector for water and corrosion

Shared checks

21 of 21

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Komatsu E202LS select solenoid: circuit short

    The pump controller finds the LS select solenoid circuit shorted, so the coil is no longer limiting current.· Other
    Check soon

    Causes

    • Harness wire to the LS select solenoid rubbed through and touching ground or another feed
    • Shorted turns or water inside the LS select solenoid coil
    • LS select solenoid valve spool sticking from dirty oil

    Checks

    1. 1Unplug the LS select solenoid and measure each wire to ground; any continuity means the harness is shorted
    2. 2Operate the LS select solenoid function and check the solenoid clicks
    3. 3Find the LS select solenoid on the main valve and check its plug first. Watch for contamination in the selector spool bore, which is common after a hose burst.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Komatsu E203Swing parking brake solenoid: circuit short

    The pump controller finds the swing parking brake solenoid circuit shorted, so the coil is no longer limiting current.· Lost message
    Check soon

    Causes

    • Harness wire to the swing parking brake solenoid rubbed through and touching ground or another feed
    • Shorted turns or water inside the swing parking brake solenoid coil
    • Swing parking brake solenoid valve spool sticking from dirty oil

    Checks

    1. 1Unplug the swing parking brake solenoid and measure each wire to ground; any continuity means the harness is shorted
    2. 2Operate the swing parking brake solenoid function and check the solenoid clicks
    3. 3Find the swing parking brake solenoid near the swing motor and check its plug first. A brake that drags can also overheat the swing motor housing, so feel it after a test.
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Komatsu E204Pump confluence/diversion solenoid: circuit short

    The pump controller finds the pump confluence/diversion solenoid circuit shorted, so the coil is no longer limiting current.· Other
    Check soon

    Causes

    • Harness wire to the pump confluence/diversion solenoid rubbed through and touching ground or another feed
    • Shorted turns or water inside the pump confluence/diversion solenoid coil
    • Pump confluence/diversion solenoid valve spool sticking from dirty oil

    Checks

    1. 1Unplug the pump confluence/diversion solenoid and measure each wire to ground; any continuity means the harness is shorted
    2. 2Operate the pump confluence/diversion solenoid function and check the solenoid clicks
    3. 3Find the confluence solenoid on the main valve and check its plug first. Listen for a clear click when the lever is moved with the boom raised against its stop.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Komatsu E205Second-stage overflow solenoid: circuit short

    The pump controller finds the second-stage overflow solenoid circuit shorted, so the coil is no longer limiting current.· Other
    Check soon

    Causes

    • Harness wire to the second-stage overflow solenoid rubbed through and touching ground or another feed
    • Shorted turns or water inside the second-stage overflow solenoid coil
    • Second-stage overflow solenoid valve spool sticking from dirty oil

    Checks

    1. 1Unplug the second-stage overflow solenoid and measure each wire to ground; any continuity means the harness is shorted
    2. 2Operate the second-stage overflow solenoid function and check the solenoid clicks
    3. 3Find the second-stage overflow solenoid on the main valve and check its plug first. Raise the relief setting with the power switch and see whether digging force changes.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Komatsu E206Travel speed switching solenoid: circuit short

    The pump controller finds the travel speed switching solenoid circuit shorted, so the coil is no longer limiting current.· Other
    Check soon

    Causes

    • Harness wire to the travel speed switching solenoid rubbed through and touching ground or another feed
    • Shorted turns or water inside the travel speed switching solenoid coil
    • Travel speed switching solenoid valve spool sticking from dirty oil

    Checks

    1. 1Unplug the travel speed switching solenoid and measure each wire to ground; any continuity means the harness is shorted
    2. 2Operate the travel speed switching solenoid function and check the solenoid clicks
    3. 3Find the travel speed solenoid near the travel motors or valve and check its plug first. Lift one track and test both speed positions to confirm the motor displacement changes.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Komatsu E207Quick mode solenoid: circuit short

    The pump controller finds the quick mode solenoid circuit shorted, so the coil is no longer limiting current.· Other
    Check soon

    Causes

    • Harness wire to the quick mode solenoid rubbed through and touching ground or another feed
    • Shorted turns or water inside the quick mode solenoid coil
    • Quick mode solenoid valve spool sticking from dirty oil

    Checks

    1. 1Unplug the quick mode solenoid and measure each wire to ground; any continuity means the harness is shorted
    2. 2Operate the quick mode solenoid function and check the solenoid clicks
    3. 3Find the quick mode solenoid on the valve block and check its plug first. Toggle the mode switch and note whether the monitor icon and the valve both respond.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Komatsu E208Quick mode solenoid: circuit open

    The pump controller finds the quick mode solenoid circuit open, so no current can flow through the coil.· Open circuit
    Check soon

    Causes

    • Broken wire or loose pin between the pump controller and the quick mode solenoid
    • Open coil inside the quick mode solenoid
    • Quick mode solenoid valve spool sticking from dirty oil

    Checks

    1. 1Key off, unplug the quick mode solenoid and measure the coil resistance; an open reading condemns the coil
    2. 2Operate the quick mode solenoid function and check the solenoid clicks
    3. 3Find the quick mode solenoid on the valve block and check its plug first. Toggle the mode switch and note whether the monitor icon and the valve both respond.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Komatsu E213Swing parking brake solenoid: circuit open

    The pump controller finds the swing parking brake solenoid circuit open, so no current can flow through the coil.· Open circuit
    Check soon

    Causes

    • Broken wire or loose pin between the pump controller and the swing parking brake solenoid
    • Open coil inside the swing parking brake solenoid
    • Swing parking brake solenoid valve spool sticking from dirty oil

    Checks

    1. 1Key off, unplug the swing parking brake solenoid and measure the coil resistance; an open reading condemns the coil
    2. 2Operate the swing parking brake solenoid function and check the solenoid clicks
    3. 3Find the swing parking brake solenoid near the swing motor and check its plug first. A brake that drags can also overheat the swing motor housing, so feel it after a test.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Komatsu E214Pump confluence/diversion solenoid: circuit open

    The pump controller finds the pump confluence/diversion solenoid circuit open, so no current can flow through the coil.· Open circuit
    Check soon

    Causes

    • Broken wire or loose pin between the pump controller and the pump confluence/diversion solenoid
    • Open coil inside the pump confluence/diversion solenoid
    • Pump confluence/diversion solenoid valve spool sticking from dirty oil

    Checks

    1. 1Key off, unplug the pump confluence/diversion solenoid and measure the coil resistance; an open reading condemns the coil
    2. 2Operate the pump confluence/diversion solenoid function and check the solenoid clicks
    3. 3Find the confluence solenoid on the main valve and check its plug first. Listen for a clear click when the lever is moved with the boom raised against its stop.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Komatsu E215Second-stage overflow solenoid: circuit open

    The pump controller finds the second-stage overflow solenoid circuit open, so no current can flow through the coil.· Open circuit
    Check soon

    Causes

    • Broken wire or loose pin between the pump controller and the second-stage overflow solenoid
    • Open coil inside the second-stage overflow solenoid
    • Second-stage overflow solenoid valve spool sticking from dirty oil

    Checks

    1. 1Key off, unplug the second-stage overflow solenoid and measure the coil resistance; an open reading condemns the coil
    2. 2Operate the second-stage overflow solenoid function and check the solenoid clicks
    3. 3Find the second-stage overflow solenoid on the main valve and check its plug first. Raise the relief setting with the power switch and see whether digging force changes.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Komatsu E216Travel speed switching solenoid: circuit open

    The pump controller finds the travel speed switching solenoid circuit open, so no current can flow through the coil.· Open circuit
    Check soon

    Causes

    • Broken wire or loose pin between the pump controller and the travel speed switching solenoid
    • Open coil inside the travel speed switching solenoid
    • Travel speed switching solenoid valve spool sticking from dirty oil

    Checks

    1. 1Key off, unplug the travel speed switching solenoid and measure the coil resistance; an open reading condemns the coil
    2. 2Operate the travel speed switching solenoid function and check the solenoid clicks
    3. 3Find the travel speed solenoid near the travel motors or valve and check its plug first. Lift one track and test both speed positions to confirm the motor displacement changes.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Komatsu E222LS-EPC solenoid: circuit short

    The pump controller finds the LS-EPC solenoid circuit shorted, so the coil is no longer limiting current.· Lost message
    Check soon

    Causes

    • Harness wire to the LS-EPC solenoid rubbed through and touching ground or another feed
    • Shorted turns or water inside the LS-EPC solenoid coil
    • LS-EPC solenoid valve spool sticking from dirty oil

    Checks

    1. 1Unplug the LS-EPC solenoid and measure each wire to ground; any continuity means the harness is shorted
    2. 2Operate the LS-EPC solenoid function and check the solenoid clicks
    3. 3Find the LS-EPC valve on the pump or main valve and check its plug first. Compare pump hunting at idle with the engine warm and cold before replacing parts.
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Komatsu E223LS-EPC solenoid: circuit open

    The pump controller finds the LS-EPC solenoid circuit open, so no current can flow through the coil.· Open circuit
    Check soon

    Causes

    • Broken wire or loose pin between the pump controller and the LS-EPC solenoid
    • Open coil inside the LS-EPC solenoid
    • LS-EPC solenoid valve spool sticking from dirty oil

    Checks

    1. 1Key off, unplug the LS-EPC solenoid and measure the coil resistance; an open reading condemns the coil
    2. 2Operate the LS-EPC solenoid function and check the solenoid clicks
    3. 3Find the LS-EPC valve on the pump or main valve and check its plug first. Compare pump hunting at idle with the engine warm and cold before replacing parts.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Komatsu E231Activation mode (swing) solenoid: circuit short

    The pump controller finds the activation mode (swing) solenoid circuit shorted, so the coil is no longer limiting current.· Other
    Check soon

    Causes

    • Harness wire to the activation mode (swing) solenoid rubbed through and touching ground or another feed
    • Shorted turns or water inside the activation mode (swing) solenoid coil
    • Activation mode (swing) solenoid valve spool sticking from dirty oil

    Checks

    1. 1Unplug the activation mode (swing) solenoid and measure each wire to ground; any continuity means the harness is shorted
    2. 2Operate the activation mode function and check the solenoid clicks
    3. 3Find the swing activation mode solenoid on the valve block and check its plug first. Swing with the bucket empty in two work modes and compare the start-up feel.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Komatsu E232Front pump TVC solenoid (old model): circuit short

    The pump controller finds the front pump TVC solenoid (old model) circuit shorted, so the coil is no longer limiting current.· Other
    Check soon

    Causes

    • Harness wire to the front pump TVC solenoid (old model) rubbed through and touching ground or another feed
    • Shorted turns or water inside the front pump TVC solenoid (old model) coil
    • Front pump TVC solenoid (old model) valve spool sticking from dirty oil

    Checks

    1. 1Unplug the front pump TVC solenoid (old model) and measure each wire to ground; any continuity means the harness is shorted
    2. 2Operate the front pump TVC solenoid function and check the solenoid clicks
    3. 3Find the front pump TVC solenoid on the front pump and check its plug first. Use a pressure gauge on the front pump test port to see whether torque control follows.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Komatsu E233Front pump TVC solenoid (old model): circuit open

    The pump controller finds the front pump TVC solenoid (old model) circuit open, so no current can flow through the coil.· Open circuit
    Check soon

    Causes

    • Broken wire or loose pin between the pump controller and the front pump TVC solenoid (old model)
    • Open coil inside the front pump TVC solenoid (old model)
    • Front pump TVC solenoid (old model) valve spool sticking from dirty oil

    Checks

    1. 1Key off, unplug the front pump TVC solenoid (old model) and measure the coil resistance; an open reading condemns the coil
    2. 2Operate the front pump TVC solenoid function and check the solenoid clicks
    3. 3Find the front pump TVC solenoid on the front pump and check its plug first. Use a pressure gauge on the front pump test port to see whether torque control follows.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Komatsu E235Activation mode (swing) solenoid: circuit open

    The pump controller finds the activation mode (swing) solenoid circuit open, so no current can flow through the coil.· Open circuit
    Check soon

    Causes

    • Broken wire or loose pin between the pump controller and the activation mode (swing) solenoid
    • Open coil inside the activation mode (swing) solenoid
    • Activation mode (swing) solenoid valve spool sticking from dirty oil

    Checks

    1. 1Key off, unplug the activation mode (swing) solenoid and measure the coil resistance; an open reading condemns the coil
    2. 2Operate the activation mode function and check the solenoid clicks
    3. 3Find the swing activation mode solenoid on the valve block and check its plug first. Swing with the bucket empty in two work modes and compare the start-up feel.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Komatsu E236Rear pump TVC solenoid: circuit short

    The pump controller finds the rear pump TVC solenoid circuit shorted, so the coil is no longer limiting current.· Other
    Check soon

    Causes

    • Harness wire to the rear pump TVC solenoid rubbed through and touching ground or another feed
    • Shorted turns or water inside the rear pump TVC solenoid coil
    • Rear pump TVC solenoid valve spool sticking from dirty oil

    Checks

    1. 1Unplug the rear pump TVC solenoid and measure each wire to ground; any continuity means the harness is shorted
    2. 2Operate the rear pump TVC solenoid function and check the solenoid clicks
    3. 3Find the rear pump TVC solenoid on the rear pump and check its plug first. Use a pressure gauge on the rear pump test port to see whether torque control follows.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Komatsu E237Rear pump TVC solenoid: circuit open

    The pump controller finds the rear pump TVC solenoid circuit open, so no current can flow through the coil.· Open circuit
    Check soon

    Causes

    • Broken wire or loose pin between the pump controller and the rear pump TVC solenoid
    • Open coil inside the rear pump TVC solenoid
    • Rear pump TVC solenoid valve spool sticking from dirty oil

    Checks

    1. 1Key off, unplug the rear pump TVC solenoid and measure the coil resistance; an open reading condemns the coil
    2. 2Operate the rear pump TVC solenoid function and check the solenoid clicks
    3. 3Find the rear pump TVC solenoid on the rear pump and check its plug first. Use a pressure gauge on the rear pump test port to see whether torque control follows.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Komatsu E302Swing stroke control solenoid: circuit short

    The pump controller finds the swing stroke control solenoid circuit shorted, so the coil is no longer limiting current.· Lost message
    Check soon

    Causes

    • Harness wire to the swing stroke control solenoid rubbed through and touching ground or another feed
    • Shorted turns or water inside the swing stroke control solenoid coil
    • Swing stroke control solenoid valve spool sticking from dirty oil

    Checks

    1. 1Unplug the swing stroke control solenoid and measure each wire to ground; any continuity means the harness is shorted
    2. 2Operate the swing stroke control solenoid function and check the solenoid clicks
    3. 3Find the swing stroke control solenoid near the swing motor and check its plug first. Brake the swing from full speed and note whether the stop is harsh or soft.
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Komatsu E303Swing stroke control solenoid: circuit open

    The pump controller finds the swing stroke control solenoid circuit open, so no current can flow through the coil.· Open circuit
    Check soon

    Causes

    • Broken wire or loose pin between the pump controller and the swing stroke control solenoid
    • Open coil inside the swing stroke control solenoid
    • Swing stroke control solenoid valve spool sticking from dirty oil

    Checks

    1. 1Key off, unplug the swing stroke control solenoid and measure the coil resistance; an open reading condemns the coil
    2. 2Operate the swing stroke control solenoid function and check the solenoid clicks
    3. 3Find the swing stroke control solenoid near the swing motor and check its plug first. Brake the swing from full speed and note whether the stop is harsh or soft.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

Shared checks

Checks, in order

  1. 1Inspect the solenoid connector for water and corrosion
  2. 2Measure the solenoid coil resistance and compare it with the shop manual value
  3. 3Measure each solenoid wire to ground with the controller connector off
  4. 4Operate the function and listen for the solenoid clicking
  5. 5Swap with a similar solenoid to see if the fault follows

Causes

  • Solenoid connector wet or corroded
  • Wire to the solenoid rubbed through
  • Failed solenoid coil, shorted or open
  • Controller output stage failed

Most common here: open circuit (10 of 21)

Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

When to stop

You'll notice: A hydraulic function that depends on the solenoid does not work correctly; the code is found only in the service mode fault history.

Lower attachments to the ground and relieve hydraulic pressure before loosening any fitting. Never feel for a leak with your hand - oil under pressure can inject through skin.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.