EF Logo

Komatsu · Pump controller

Komatsu Fault Code DXA8KA

PC-EPC (front pump) solenoid: circuit open

What does Komatsu code DXA8KA mean?

The pump controller finds the front pump PC-EPC solenoid circuit open, so no current reaches the coil that sets the front pump output. The front pump cannot be adjusted, and the machine loses pump power or responds slowly. Urgency: check soon - the machine may derate or limit a function. Check first: look at the front PC-EPC connector at the pump for water, corrosion and pushed-back pins.

FaultCheckDXA8KAKomatsu · Pump controller

Can I keep running with it?

Check soon

The machine may derate or limit a function. Find the cause before the next shift.

What should I check first?

Look at the front PC-EPC connector at the pump for water, corrosion and pushed-back pins

Then 4 more checks
Code shows hereFAULTDXA8KA

Where this code shows

Watch the monitor for the user code and the caution lamp or buzzer, and write the code down.

Checks

0 of 5 done

Causes

  • Front PC-EPC connector at the pump loose, oily or corroded
  • Open wire between the pump controller and the front PC-EPC solenoid
  • Open coil in the front PC-EPC solenoid
  • Pump controller output stage failed

How it failed

You'll notice: Weak or slow hydraulics with DXA8KA on the monitor.

Open circuitRead from how the source describes the code

No current flows, or the signal floats - a wire, pin or coil is broken.

ControllerPartSupplySignalGround
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.
Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good result
Near 0 Ω on each wire. The part reads its listed resistance, not OL.

When to stop

Lower attachments to the ground and relieve hydraulic pressure before loosening any fitting. Never feel for a leak with your hand - oil under pressure can inject through skin.

Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Same part, other failures: Pump PC-EPC, LS-EPC and flow divider solenoids

Source

SINOCMP - Error Code List for Komatsu PC200-8, PC220-8 and PC220LC-8 Excavators (failure code table)

This source lists DXA8KA and its meaning. The guidance on this page is general, not taken from it.

The source covers: Komatsu PC200-8, PC220-8 and PC220LC-8 excavators (the models the source lists).

Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.