Komatsu · Pump controller
Komatsu Fault Code DW43KA
Travel speed solenoid: circuit open
What does Komatsu code DW43KA mean?
The pump controller finds the travel speed solenoid circuit open, so the solenoid cannot change the travel motors between speeds. The machine stays in one speed range and travel feels slow or will not shift. Urgency: check soon - the machine may derate or limit a function. Check first: inspect the travel speed solenoid connector for water and loose pins.
Can I keep running with it?
Check soon
The machine may derate or limit a function. Find the cause before the next shift.
What should I check first?
Inspect the travel speed solenoid connector for water and loose pins
Then 4 more checksWhere this code shows
Watch the monitor for the user code and the caution lamp or buzzer, and write the code down.
Checks
0 of 5 done
Causes
- Travel speed solenoid connector loose or corroded
- Open wire between the pump controller and the solenoid
- Open coil in the travel speed solenoid
- Pump controller output stage failed
How it failed
You'll notice: Travel will not shift between speeds, with DW43KA on the monitor.
Open circuitRead from how the source describes the code
No current flows, or the signal floats - a wire, pin or coil is broken.
- Meter test
- Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
- Good result
- Near 0 Ω on each wire. The part reads its listed resistance, not OL.
When to stop
Lower attachments to the ground and relieve hydraulic pressure before loosening any fitting. Never feel for a leak with your hand - oil under pressure can inject through skin.
Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Same part, other failures: Travel speed, swing brake and relief solenoids
4 other codes on this part are also open circuit (DWK0KA, DWA2KA, DW45KA, DW91KA). When they show together, start at the wiring and connector they share.
- DWK0KASecond-stage overflow (relief) solenoid: circuit openOpen circuitCheck soon
- DWK0KBSecond-stage overflow (relief) solenoid: circuit shortOtherCheck soon
- DWA2KABackup solenoid: circuit openOpen circuitCheck soon
- DWA2KBBackup solenoid: circuit shortOtherCheck soon
- DW43KATravel speed solenoid: circuit openOpen circuitCheck soon
- DW43KBTravel speed solenoid: circuit shortOtherCheck soon
- DW45KASwing brake solenoid: circuit openOpen circuitCheck soon
- DW45KBSwing brake solenoid: circuit shortErratic or implausibleCheck soon
- DW91KATravel junction solenoid: circuit openOpen circuitCheck soon
- DW91KBTravel junction solenoid: circuit shortOtherCheck soon
Other Komatsu codes: Pump controller
Related on Equipments Finder
Source
SINOCMP - Error Code List for Komatsu PC200-8, PC220-8 and PC220LC-8 Excavators (failure code table)
This source lists DW43KA and its meaning. The guidance on this page is general, not taken from it.
The source covers: Komatsu PC200-8, PC220-8 and PC220LC-8 excavators (the models the source lists).
Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?