John Deere · Main controller (MCZ) - pressure sensors
John Deere Swing, travel and attachment pressure sensors fault codes
Four sensors report circuit pressure for the swing, travel and attachment functions. B33 reads the swing circuit so the controller can manage swing power and smoothness.
More about these partsLess
B34 reads the travel circuit and feeds travel auto-shift. B32 reads the front attachment circuit and a further sensor the attachment circuit under its own code numbers; the controller uses them for the flow and relief settings of a breaker or crusher.
Where this code shows
Turn the key on and open the monitor's diagnostic/fault screen.
What do these codes mean?
John Deere codes MCZ 11301.03 to MCZ 11942.04 are all about the swing, travel and attachment pressure sensors. None needs an immediate stop. Start with this check: read which sensor the code names (B33 swing, B34 travel, B32 front attachment or the attachment sensor) and unplug that one only.
How urgent are they?
None of the 8 codes here means stop now; all 8 can wait until the shift ends, but find the cause before the next one.
- Check soon8
What should I check first?
Read which sensor the code names (B33 swing, B34 travel, B32 front attachment or the attachment sensor) and unplug that one only
Shared checks8 of 8
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
John Deere MCZ 11301.03Swing pressure sensor (B33) signal high
The main controller reads the swing pressure sensor (B33) on the swing circuit as high. The control logic that uses this pressure becomes unreliable, so the machine may feel weak or jerky.· OtherOtherCheck soonCauses
- B33 signal wire shorted to its 5 V feed in the harness that runs up through the upper frame
- B33 return wire open, so the signal floats high
- B33 failed high inside
Checks
- 1Unplug B33 and, key on, measure its harness signal pin; a reading close to 5 V points to the wiring
- 2Check B33 ground continuity to the MCZ with the harness disconnected at both ends
- 3Read swing pressure on the monitor with the swing lever in neutral; it should be near zero
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
John Deere MCZ 11301.04Swing pressure sensor (B33) signal low
The main controller reads the swing pressure sensor (B33) on the swing circuit as low. The control logic that uses this pressure becomes unreliable, so the machine may feel weak or jerky.· OtherOtherCheck soonCauses
- B33 signal wire cut where it crosses from the upper frame
- B33 signal wire shorted to the frame
- B33 supply wire broken or its pin pushed back
Checks
- 1Check for 5 V at the B33 supply pin with the key on; zero volts means the supply side is open
- 2Check the B33 signal wire for a short to chassis ground with both connectors unplugged
- 3Check signal wire continuity from B33 to the MCZ, wiggling the harness around the swing area
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
John Deere MCZ 11304.03Travel pressure sensor (B34) signal high
The main controller reads the travel pressure sensor (B34) on the travel circuit as high. The control logic that uses this pressure becomes unreliable, so the machine may feel weak or jerky.· OtherOtherCheck soonCauses
- B34 signal shorted to supply in the undercarriage harness
- B34 failed high
- B34 ground open
Checks
- 1Disconnect B34 and measure its harness signal pin; supply voltage there means the harness is shorted
- 2Check ground continuity from the B34 return pin to the MCZ sensor ground pin
- 3Look at the travel pressure display with the travel levers in neutral and the machine stopped
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
John Deere MCZ 11304.04Travel pressure sensor (B34) signal low
The main controller reads the travel pressure sensor (B34) on the travel circuit as low. The control logic that uses this pressure becomes unreliable, so the machine may feel weak or jerky.· OtherOtherCheck soonCauses
- Broken signal wire at B34 or in the harness run to the MCZ
- Signal wire shorted to the frame
- B34 supply wire broken
Checks
- 1Check 5 V at the B34 connector supply and ground pins with the key on
- 2Test the signal wire to chassis ground for a short with the connectors unplugged
- 3Check signal wire continuity from the B34 connector to the MCZ
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
John Deere MCZ 11307.03Front attachment pressure sensor (B32) signal high
The main controller reads the front attachment pressure sensor (B32) on the front attachment circuit as high. The control logic that uses this pressure becomes unreliable, so the machine may feel weak or jerky.· OtherOtherCheck soonCauses
- B32 signal wire shorted to supply near the attachment line
- B32 failed high
- Open ground wire to B32
Checks
- 1Unplug B32 and read the signal pin voltage with the key on
- 2Check the B32 sensor ground continuity to the MCZ
- 3With the attachment lever in neutral, see whether the monitor shows pressure on the attachment channel
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
John Deere MCZ 11307.04Front attachment pressure sensor (B32) signal low
The main controller reads the front attachment pressure sensor (B32) on the front attachment circuit as low. The control logic that uses this pressure becomes unreliable, so the machine may feel weak or jerky.· OtherOtherCheck soonCauses
- Open B32 signal wire
- B32 signal shorted to ground
- No supply voltage at B32
Checks
- 1Check supply and ground at B32 with the key on
- 2Test the signal wire to ground with the connector unplugged
- 3Check signal wire continuity from B32 to the MCZ
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
John Deere MCZ 11942.03Attachment pressure sensor circuit voltage high
The controller reads the attachment pressure sensor signal above its normal range, so it cannot use the value and the function that depends on it runs on a fallback or is switched off.· Shorted highShorted highCheck soonCauses
- Signal wire of the attachment pressure sensor shorted to the 5 V supply or to battery voltage
- Open return (ground) wire at the attachment pressure sensor, which lets the signal float high
- The attachment pressure sensor failed internally with a stuck high output
Checks
- 1Unplug the attachment pressure sensor and, key on, measure the harness signal pin: a value near 5 V points to a harness short or a controller fault rather than the part
- 2Check continuity of the attachment pressure sensor return wire to the controller sensor ground with both ends disconnected
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
John Deere MCZ 11942.04Attachment pressure sensor circuit voltage low
The controller reads the attachment pressure sensor signal below its normal range, so it cannot use the value and the function that depends on it runs on a fallback or is switched off.· Shorted lowShorted lowCheck soonCauses
- Signal wire of the attachment pressure sensor shorted to ground
- Broken or unplugged 5 V supply wire to the attachment pressure sensor
- The attachment pressure sensor failed internally with a stuck low output
Checks
- 1With the attachment pressure sensor unplugged and the key on, check for the 5 V supply on its harness plug; no supply means a broken feed wire or a faulty controller output
- 2Measure the signal wire to ground with both ends disconnected; a very low resistance means a short to ground in the harness
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Shared checks
Checks, in order
- 1Read which sensor the code names (B33 swing, B34 travel, B32 front attachment or the attachment sensor) and unplug that one only
- 2Key on, measure the signal pin of the unplugged sensor: about 5 V means short to the feed, about 0 V means short to ground or an open wire
- 3Compare the live value with what the circuit is doing; with the lever neutral swing, travel and the tool should read low
- 4Check the sensor ground wire to the MCZ for continuity with both ends disconnected
- 5Follow the harness for rub marks where it crosses frame edges, and inspect the plug for corrosion and bent pins
Causes
- Sensor failed inside and sending a fixed voltage
- Signal wire chafed on the swing frame, track frame or boom, touching feed or ground
- Plug pulled loose or flooded after pressure washing
- Broken return wire letting the signal float high
When to stop
You'll notice: Swing can feel harsh or weak, travel can shift oddly, or a tool can run at the wrong flow or relief setting, depending on which circuit the code names.
Lower attachments to the ground and relieve hydraulic pressure before loosening any fitting. Never feel for a leak with your hand - oil under pressure can inject through skin.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.