John Deere · Main controller (MCZ) - solenoids
John Deere Pump flow, torque and displacement solenoids fault codes
These solenoid valves shape how much oil the main pumps deliver. The SB solenoid (Y20) limits pump 2 flow and a matching solenoid limits pump 1.
More about these partsLess
The torque control solenoid (ST) limits pump torque to protect the engine. Pump control valve solenoids 1 and 2 set the displacement of each pump and have a learning routine, and the swing flow rate solenoid limits swing flow. The MCZ compares drive current with fed-back current and sets a code when they differ.
Where this code shows
Turn the key on and open the monitor's diagnostic/fault screen.
What do these codes mean?
John Deere codes MCZ 11400.02 to MCZ 11986.02 are all about the pump flow, torque and displacement solenoids. Most are real condition faults; none needs an immediate stop. Start with this check: identify the solenoid the code names and unplug its connector.
How urgent are they?
None of the 22 codes here means stop now; all 22 can wait until the shift ends, but find the cause before the next one.
- Check soon22
What should I check first?
Identify the solenoid the code names and unplug its connector
Shared checks22 of 22
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
John Deere MCZ 11400.02Pump 2 flow rate limit solenoid (SB), feedback abnormal
The MCZ drives the pump 2 flow rate limit solenoid (sb) (Y20) but the current fed back does not match the command (feedback abnormal). The source quotes trip points near 920 mA high and 70 mA low. Pump control or engine load matching may be degraded.· OtherOtherCheck soonCauses
- Y20 coil resistance drifted or partly shorted, so the current does not follow the command
- Intermittent contact in the Y20 plug, giving a current that jumps about
- Contaminated or sticking spool in the pump 2 flow limit valve loading the coil unevenly
- Y20 wires chafed against each other or the frame, touching only when the machine vibrates
Checks
- 1Watch the Y20 current on the monitor service screen while changing engine speed and compare it with the commanded value
- 2Unplug Y20 and measure the coil resistance, then compare it with the service manual value or a matching coil on the machine
- 3Wiggle the Y20 harness and plug with the engine running and see if the current reading jumps
- 4Inspect the Y20 harness between the pump 2 regulator and the MCZ for rubbed insulation and oil soaking
- 5Remove and clean the valve only if the coil and wiring are good and the current still does not follow
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
John Deere MCZ 11400.03Pump 2 flow rate limit solenoid (SB), feedback current too high
The MCZ drives the pump 2 flow rate limit solenoid (sb) (Y20) but the current fed back does not match the command (feedback current too high). The source quotes trip points near 920 mA high and 70 mA low. Pump control or engine load matching may be degraded.· Real conditionReal conditionCheck soonCauses
- Y20 coil with shorted turns, drawing too much current
- Y20 return wire shorted to the supply side somewhere in the harness
- Water in the Y20 plug creating a leak path that adds current
Checks
- 1Unplug Y20 and measure the coil resistance; a value well below the manual figure points to shorted turns
- 2With the MCZ connector off, check the Y20 wires for any continuity to battery positive that should not exist
- 3Open the Y20 plug and look for moisture, green corrosion and burnt contacts
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
John Deere MCZ 11400.04Pump 2 flow rate limit solenoid (SB), feedback current too low
The MCZ drives the pump 2 flow rate limit solenoid (sb) (Y20) but the current fed back does not match the command (feedback current too low). The source quotes trip points near 920 mA high and 70 mA low. Pump control or engine load matching may be degraded.· Real conditionReal conditionCheck soonCauses
- Y20 coil open inside
- Broken Y20 wire or a pin pushed out of the plug
- Blown or missing fuse in the supply feeding the MCZ solenoid outputs
Checks
- 1Unplug Y20 and measure the coil; an open-circuit reading confirms the coil has failed
- 2Check continuity of both Y20 wires from the plug to the MCZ pins
- 3Check the fuse and power feed for the MCZ solenoid outputs
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
John Deere MCZ 11401.02Torque control solenoid (ST), feedback abnormal
The MCZ drives the torque control solenoid (st) (Y21) but the current fed back does not match the command (feedback abnormal). The source quotes trip points near 920 mA high and 70 mA low. Pump control or engine load matching may be degraded.· OtherOtherCheck soonCauses
- Y21 coil resistance off or the coil partly shorted
- Poor contact in the Y21 plug so the current wanders
- Torque control valve contaminated and dragging against the coil load
Checks
- 1Compare the Y21 current on the monitor with the commanded value at several engine speeds
- 2Measure the Y21 coil resistance with the plug removed and compare it with the service manual figure
- 3Wiggle the Y21 plug and harness with the engine running to see if the current reading changes
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
John Deere MCZ 11401.03Torque control solenoid (ST), feedback current too high
The MCZ drives the torque control solenoid (st) (Y21) but the current fed back does not match the command (feedback current too high). The source quotes trip points near 920 mA high and 70 mA low. Pump control or engine load matching may be degraded.· Real conditionReal conditionCheck soonCauses
- Y21 coil with shorted turns
- Y21 wire shorted to the supply side in the harness
- Moisture in the Y21 plug creating a leak path
Checks
- 1Unplug Y21 and measure the coil resistance; a low reading versus the manual points to a shorted coil
- 2Check the Y21 wires with the MCZ plug off for any unwanted continuity to battery positive
- 3Inspect the Y21 plug for water and burn marks on the terminals
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
John Deere MCZ 11401.04Torque control solenoid (ST), feedback current too low
The MCZ drives the torque control solenoid (st) (Y21) but the current fed back does not match the command (feedback current too low). The source quotes trip points near 920 mA high and 70 mA low. Pump control or engine load matching may be degraded.· Real conditionReal conditionCheck soonCauses
- Y21 coil open
- Broken Y21 wire or a pin backed out of the plug
- No supply to the Y21 circuit because of a blown fuse
Checks
- 1Unplug Y21 and measure the coil; an open reading means the coil has failed
- 2Check continuity of both Y21 wires from the plug to the MCZ pins
- 3Check the fuse in the solenoid supply circuit and the power feed to the MCZ outputs
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
John Deere MCZ 11410.02Pump 1 flow rate limit solenoid valve abnormal feedback
The current feedback of the pump 1 flow rate limit solenoid is abnormal: the controller sees the drive current leaving its allowed band, so the valve does not move as commanded.· OtherOtherCheck soonCauses
- Faulty coil or damaged wiring at the pump 1 flow rate limit solenoid
- Corroded or loose connector pin raising the circuit resistance
- Controller output stage not driving correctly
Checks
- 1Measure the pump 1 flow rate limit solenoid coil resistance at its plug and compare it with the manual value
- 2Check the harness and plug for corrosion, oil and pins that are pushed out
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
John Deere MCZ 11410.03Pump 1 flow rate limit solenoid valve feedback high current
The feedback current of the pump 1 flow rate limit solenoid is too high, so the coil or its circuit draws more than the controller expects.· Real conditionReal conditionCheck soonCauses
- Shorted turns inside the pump 1 flow rate limit solenoid coil
- Harness shorted to battery voltage or to another wire
- Controller output stage failed on
Checks
- 1Measure the pump 1 flow rate limit solenoid coil resistance; a value far below the manual figure means shorted turns
- 2Check the harness for a short to supply or to a neighbouring wire with both ends unplugged
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
John Deere MCZ 11410.04Pump 1 flow rate limit solenoid valve feedback low current
The feedback current of the pump 1 flow rate limit solenoid is too low, so the coil or its circuit carries less current than the controller expects.· Real conditionReal conditionCheck soonCauses
- Open or burnt coil in the pump 1 flow rate limit solenoid
- Corroded connector or broken wire raising the circuit resistance
- Controller output stage not driving
Checks
- 1Measure the pump 1 flow rate limit solenoid coil resistance; an open or very high value means a failed coil
- 2Check the wires and plug for breaks and corrosion with both ends unplugged
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
John Deere MCZ 11950.02Pump control valve solenoid 2 feedback current abnormal
The current feedback of the pump control valve solenoid 2 is abnormal: the controller sees the drive current leaving its allowed band, so the valve does not move as commanded.· OtherOtherCheck soonCauses
- Faulty coil or damaged wiring at the pump control valve solenoid 2
- Corroded or loose connector pin raising the circuit resistance
- Controller output stage not driving correctly
Checks
- 1Measure the pump control valve solenoid 2 coil resistance at its plug and compare it with the manual value
- 2Check the harness and plug for corrosion, oil and pins that are pushed out
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
John Deere MCZ 11950.03Pump control valve solenoid 2 feedback current high
The feedback current of the pump control valve solenoid 2 is too high, so the coil or its circuit draws more than the controller expects.· Real conditionReal conditionCheck soonCauses
- Shorted turns inside the pump control valve solenoid 2 coil
- Harness shorted to battery voltage or to another wire
- Controller output stage failed on
Checks
- 1Measure the pump control valve solenoid 2 coil resistance; a value far below the manual figure means shorted turns
- 2Check the harness for a short to supply or to a neighbouring wire with both ends unplugged
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
John Deere MCZ 11950.04Pump control valve solenoid 2 feedback current low
The feedback current of the pump control valve solenoid 2 is too low, so the coil or its circuit carries less current than the controller expects.· Real conditionReal conditionCheck soonCauses
- Open or burnt coil in the pump control valve solenoid 2
- Corroded connector or broken wire raising the circuit resistance
- Controller output stage not driving
Checks
- 1Measure the pump control valve solenoid 2 coil resistance; an open or very high value means a failed coil
- 2Check the wires and plug for breaks and corrosion with both ends unplugged
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
John Deere MCZ 11951.02Pump control valve solenoid 1 feedback current abnormal
The current feedback of the pump control valve solenoid 1 is abnormal: the controller sees the drive current leaving its allowed band, so the valve does not move as commanded.· OtherOtherCheck soonCauses
- Faulty coil or damaged wiring at the pump control valve solenoid 1
- Corroded or loose connector pin raising the circuit resistance
- Controller output stage not driving correctly
Checks
- 1Measure the pump control valve solenoid 1 coil resistance at its plug and compare it with the manual value
- 2Check the harness and plug for corrosion, oil and pins that are pushed out
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
John Deere MCZ 11951.03Pump control valve solenoid 1 feedback current high
The feedback current of the pump control valve solenoid 1 is too high, so the coil or its circuit draws more than the controller expects.· Real conditionReal conditionCheck soonCauses
- Shorted turns inside the pump control valve solenoid 1 coil
- Harness shorted to battery voltage or to another wire
- Controller output stage failed on
Checks
- 1Measure the pump control valve solenoid 1 coil resistance; a value far below the manual figure means shorted turns
- 2Check the harness for a short to supply or to a neighbouring wire with both ends unplugged
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
John Deere MCZ 11951.04Pump control valve solenoid 1 feedback current low
The feedback current of the pump control valve solenoid 1 is too low, so the coil or its circuit carries less current than the controller expects.· Real conditionReal conditionCheck soonCauses
- Open or burnt coil in the pump control valve solenoid 1
- Corroded connector or broken wire raising the circuit resistance
- Controller output stage not driving
Checks
- 1Measure the pump control valve solenoid 1 coil resistance; an open or very high value means a failed coil
- 2Check the wires and plug for breaks and corrosion with both ends unplugged
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
John Deere MCZ 11953.02Swing flow rate solenoid feedback current abnormal
The current feedback of the swing flow rate solenoid is abnormal: the controller sees the drive current leaving its allowed band, so the valve does not move as commanded.· OtherOtherCheck soonCauses
- Faulty coil or damaged wiring at the swing flow rate solenoid
- Corroded or loose connector pin raising the circuit resistance
- Controller output stage not driving correctly
Checks
- 1Measure the swing flow rate solenoid coil resistance at its plug and compare it with the manual value
- 2Check the harness and plug for corrosion, oil and pins that are pushed out
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
John Deere MCZ 11953.03Swing flow rate solenoid feedback current high
The feedback current of the swing flow rate solenoid is too high, so the coil or its circuit draws more than the controller expects.· Real conditionReal conditionCheck soonCauses
- Shorted turns inside the swing flow rate solenoid coil
- Harness shorted to battery voltage or to another wire
- Controller output stage failed on
Checks
- 1Measure the swing flow rate solenoid coil resistance; a value far below the manual figure means shorted turns
- 2Check the harness for a short to supply or to a neighbouring wire with both ends unplugged
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
John Deere MCZ 11953.04Swing flow rate solenoid feedback current low
The feedback current of the swing flow rate solenoid is too low, so the coil or its circuit carries less current than the controller expects.· Real conditionReal conditionCheck soonCauses
- Open or burnt coil in the swing flow rate solenoid
- Corroded connector or broken wire raising the circuit resistance
- Controller output stage not driving
Checks
- 1Measure the swing flow rate solenoid coil resistance; an open or very high value means a failed coil
- 2Check the wires and plug for breaks and corrosion with both ends unplugged
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
John Deere MCZ 11971.02Pump control valve solenoid 1 abnormal learning
The learning routine for pump control valve solenoid 1 did not give a valid result, so the controller does not have the correct starting point for that pump's control current.· OtherOtherCheck soonCauses
- Wiring or connector fault in the circuit behind this code
- The part or unit the code names failing
- Low or unstable supply voltage to the controller
Checks
- 1Check the connector and wiring behind this code for corrosion, oil and pins that are pushed out
- 2Measure supply voltage and ground at the controller and clear the code to see if it returns
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
John Deere MCZ 11972.02Pump control valve solenoid 2 abnormal learning
The learning routine for pump control valve solenoid 2 did not give a valid result, so the controller lacks the correct starting current for the second pump control.· OtherOtherCheck soonCauses
- Wiring or connector fault in the circuit behind this code
- The part or unit the code names failing
- Low or unstable supply voltage to the controller
Checks
- 1Check the connector and wiring behind this code for corrosion, oil and pins that are pushed out
- 2Measure supply voltage and ground at the controller and clear the code to see if it returns
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
John Deere MCZ 11985.02Pump control valve solenoid 2 learning failure
The controller could not complete the learning of pump control valve solenoid 2 and marked it failed, so the stored correction for the second pump is invalid.· OtherOtherCheck soonCauses
- Wiring or connector fault in the circuit behind this code
- The part or unit the code names failing
- Low or unstable supply voltage to the controller
Checks
- 1Check the connector and wiring behind this code for corrosion, oil and pins that are pushed out
- 2Measure supply voltage and ground at the controller and clear the code to see if it returns
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
John Deere MCZ 11986.02Pump control valve solenoid 1 learning failure
The controller could not finish the learning of pump control valve solenoid 1 and flagged it as failed, which leaves the stored pump correction invalid.· OtherOtherCheck soonCauses
- Wiring or connector fault in the circuit behind this code
- The part or unit the code names failing
- Low or unstable supply voltage to the controller
Checks
- 1Check the connector and wiring behind this code for corrosion, oil and pins that are pushed out
- 2Measure supply voltage and ground at the controller and clear the code to see if it returns
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Shared checks
Checks, in order
- 1Identify the solenoid the code names and unplug its connector
- 2Measure coil resistance and compare it with the manual: open or very high means a burnt coil (current too low), far below means shorted turns (current too high)
- 3Check the harness for a short to supply, ground or a neighbouring wire with both ends unplugged
- 4Read the commanded and fed-back current on the service screen while using the function
- 5For learning codes confirm the machine conditions the manual requires, then repeat the learning routine
Causes
- Coil open, or shorted turns inside the solenoid
- Wire rubbed through near the pump regulator and shorted to supply, ground or a neighbouring wire
- Connector corroded or pins loose, adding resistance
- Learning routine interrupted or invalid after a pump or controller change
Most codes here: real condition (12 of 22)
Check the real value with a separate gauge or thermometer before blaming the sensor.
When to stop
You'll notice: Pump output is wrong or limited, digging speed changes without operator input, and the machine may run slow with several pump codes at once.
Lower attachments to the ground and relieve hydraulic pressure before loosening any fitting. Never feel for a leak with your hand - oil under pressure can inject through skin.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.