John Deere · Main controller (MCZ) - solenoids
John Deere Fault Code MCZ 11400.02
Pump 2 flow rate limit solenoid (SB), feedback abnormal
What does John Deere code MCZ 11400.02 mean?
The MCZ drives the pump 2 flow rate limit solenoid (sb) (Y20) but the current fed back does not match the command (feedback abnormal). Urgency: check soon - the machine may derate or limit a function. Check first: watch the Y20 current on the monitor service screen while changing engine speed and compare it with the commanded value.
- MCZ
- Which controller reports it
- 11400
- What is at fault
- .02
- How it failed
Can I keep running with it?
Check soon
The machine may derate or limit a function. Find the cause before the next shift.
What should I check first?
Watch the Y20 current on the monitor service screen while changing engine speed and compare it with the commanded value
Then 4 more checksWhere this code shows
Turn the key on and open the monitor's diagnostic/fault screen.
Checks
0 of 5 done
Causes
- Y20 coil resistance drifted or partly shorted, so the current does not follow the command
- Intermittent contact in the Y20 plug, giving a current that jumps about
- Contaminated or sticking spool in the pump 2 flow limit valve loading the coil unevenly
- Y20 wires chafed against each other or the frame, touching only when the machine vibrates
How it failed
You'll notice: The pump 2 flow limit solenoid (Y20) is not doing what the MCZ commands, so pump 2 flow cannot be trimmed on request.
OtherRead from how the source describes the code
The source does not say how this one failed.
- Meter test
- Read the code with the service tool and note which other codes are active with it.
- Good result
- Codes that appear together usually share one cause - start with the wiring they share.
When to stop
Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.
Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Same part, other failures: Pump flow, torque and displacement solenoids
- MCZ 11400.02Pump 2 flow rate limit solenoid (SB), feedback abnormalOtherCheck soon
- MCZ 11400.03Pump 2 flow rate limit solenoid (SB), feedback current too highReal conditionCheck soon
- MCZ 11400.04Pump 2 flow rate limit solenoid (SB), feedback current too lowReal conditionCheck soon
- MCZ 11401.02Torque control solenoid (ST), feedback abnormalOtherCheck soon
- MCZ 11401.03Torque control solenoid (ST), feedback current too highReal conditionCheck soon
- MCZ 11401.04Torque control solenoid (ST), feedback current too lowReal conditionCheck soon
- MCZ 11410.02Pump 1 flow rate limit solenoid valve abnormal feedbackOtherCheck soon
- MCZ 11410.03Pump 1 flow rate limit solenoid valve feedback high currentReal conditionCheck soon
- MCZ 11410.04Pump 1 flow rate limit solenoid valve feedback low currentReal conditionCheck soon
Show the other 13 codesHide the other codes
- MCZ 11950.02Pump control valve solenoid 2 feedback current abnormalOtherCheck soon
- MCZ 11950.03Pump control valve solenoid 2 feedback current highReal conditionCheck soon
- MCZ 11950.04Pump control valve solenoid 2 feedback current lowReal conditionCheck soon
- MCZ 11951.02Pump control valve solenoid 1 feedback current abnormalOtherCheck soon
- MCZ 11951.03Pump control valve solenoid 1 feedback current highReal conditionCheck soon
- MCZ 11951.04Pump control valve solenoid 1 feedback current lowReal conditionCheck soon
- MCZ 11953.02Swing flow rate solenoid feedback current abnormalOtherCheck soon
- MCZ 11953.03Swing flow rate solenoid feedback current highReal conditionCheck soon
- MCZ 11953.04Swing flow rate solenoid feedback current lowReal conditionCheck soon
- MCZ 11971.02Pump control valve solenoid 1 abnormal learningOtherCheck soon
- MCZ 11972.02Pump control valve solenoid 2 abnormal learningOtherCheck soon
- MCZ 11985.02Pump control valve solenoid 2 learning failureOtherCheck soon
- MCZ 11986.02Pump control valve solenoid 1 learning failureOtherCheck soon
Other John Deere codes: Main controller (MCZ) - solenoids
Related on Equipments Finder
Source
Excavator Fault Codes - John Deere excavators fault codes list (MCZ/ECU/DSZ)
This source lists MCZ 11400.02 and its meaning. The guidance on this page is general, not taken from it.
The source covers: John Deere G-series excavators (210G/210GLC and 350G class) with MCZ main controller; confirm against serial number.
Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?