John Deere · Engine control unit (ECU) - Cooling
John Deere Cooling fan control, reversing and speed fault codes
The cooling fan is driven hydraulically and controlled from two sides. The MCZ runs the hydraulic fan control solenoid and reversing solenoids 1 and 2, comparing drive and fed-back current.
More about these partsLess
The ECU runs the variable speed fan solenoid (Y5005), the reversing solenoid Y9 with its manual reverse switch S15, and the fan speed sensor, and compares actual fan speed with the speed it wants. The prefix of the code shows which controller raised it.
Where this code shows
Turn the key on and open the monitor's diagnostic/fault screen.
What do these codes mean?
John Deere codes ECU 000647.05 to ECU 065372.06 are all about the cooling fan control, reversing and speed. The most common failure type is real condition (6 of 23); none needs an immediate stop. Start with this check: read the prefix (MCZ or ECU) and which solenoid or sensor the code names before testing.
How urgent are they?
None of the 23 codes here means stop now; all 23 can wait until the shift ends, but find the cause before the next one.
- Check soon23
What should I check first?
Read the prefix (MCZ or ECU) and which solenoid or sensor the code names before testing
Shared checks23 of 23
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
John Deere ECU 000647.05Variable speed fan solenoid (Y5005) open circuit
The ECU sees an open circuit in the variable speed fan solenoid (Y5005) circuit. The fan speed cannot be controlled, so cooling may suffer and the engine may run hot. The variable speed solenoid (Y5005) sets fan speed, so the fan may run at fixed speed or full speed.· Open circuitOpen circuitCheck soonCauses
- Y5005 proportional coil open inside
- Broken Y5005 wire or a loose connector in the fan drive harness
- Blown fuse in the Y5005 supply
Checks
- 1Measure the Y5005 coil resistance with the plug removed
- 2Check the Y5005 wiring continuity from the plug to the ECU pin
- 3Check the fuse in the Y5005 supply circuit for a blown element
- 4Measure the Y5005 coil resistance and check its plug for oil and corrosion.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
John Deere ECU 000647.06Variable speed fan solenoid (Y5005) short circuit
The ECU sees a short circuit in the variable speed fan solenoid (Y5005) circuit. The fan speed cannot be controlled correctly, and the short can blow a fuse or damage the ECU output. The variable speed solenoid (Y5005) sets fan speed, so the fan may run at fixed speed or full speed.· Lost messageLost messageCheck soonCauses
- Y5005 proportional coil windings shorted internally
- Y5005 control wire pinched in the fan drive harness and touching ground
- Moisture in the Y5005 connector pulling the circuit to ground
Checks
- 1Measure the Y5005 coil resistance with the plug off and compare it with a known good coil
- 2Unplug Y5005 and watch whether the short code turns into an open-circuit code
- 3Check the Y5005 control wire for a short to ground with the ECU end disconnected
- 4Measure the Y5005 coil resistance and check its plug for oil and corrosion.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
John Deere ECU 000647.16Manual purge mode switch active too long
The reversing fan switch (S15) has been active too long, which means the switch is stuck on or its wire is shorted. Switch S15 has been held on too long, so the fan may keep reversing.· OtherOtherCheck soonCauses
- Wiring or connector fault in the circuit behind this code
- The part or unit the code names failing
- Low or unstable supply voltage to the controller
Checks
- 1Check the connector and wiring behind this code for corrosion, oil and pins that are pushed out
- 2Measure supply voltage and ground at the controller and clear the code to see if it returns
- 3Check switch S15 with a meter released and pressed; it must open when released.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
John Deere ECU 000647.31Fan manual reverse mode input active too long
The fan manual reverse input stays active longer than expected, so the reverse request is stuck. The manual reverse request stays active, so the fan may stay in reverse.· OtherOtherCheck soonCauses
- Wiring or connector fault in the circuit behind this code
- The part or unit the code names failing
- Low or unstable supply voltage to the controller
Checks
- 1Check the connector and wiring behind this code for corrosion, oil and pins that are pushed out
- 2Measure supply voltage and ground at the controller and clear the code to see if it returns
- 3Check the reverse input wire for a short to supply and the switch for sticking.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
John Deere ECU 001639.00Fan speed high
The ECU sees the cooling fan running faster than commanded. The operator may hear the fan at full speed and see higher fuel use, or the engine may run cold. The ECU sees the fan faster than commanded, so the operator hears the fan at full speed and fuel use rises.· OtherOtherCheck soonCauses
- Fan control solenoid stuck open or its driver shorted, giving full flow to the fan motor
- Fan speed sensor reading too high
- Fan control valve spool sticking at full flow
Checks
- 1Watch the fan speed against the command on the monitor at a steady engine speed
- 2Check the fan solenoid wiring for a short to supply
- 3Check the fan speed sensor signal against the real fan speed with a tachometer
- 4Compare commanded and actual fan speed; if the actual is high with a low command, the control valve is stuck open.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
John Deere ECU 001639.01Fan speed low
The ECU sees fan speed below the commanded value, with zero speed being the most severe case. The operator may see coolant or hydraulic oil temperature rising and the engine may derate. The ECU sees the fan slower than commanded, so coolant and hydraulic oil temperatures climb.· OtherOtherCheck soonCauses
- Fan blades or drive jammed by debris or a seized bearing
- Fan solenoid open or failed so the fan gets no drive
- Fan speed sensor not reading
- Low hydraulic flow to the fan motor
Checks
- 1Look at the fan for blockage and spin it by hand with the engine off to feel for a seized bearing
- 2Check the fan solenoid and its wiring for an open circuit
- 3Check the fan speed sensor and its air gap to the target
- 4Check the hydraulic flow and pressure to the fan drive
- 5Check for fan related codes logged at the same time
- 6Check for a blocked cooler, low hydraulic supply to the fan motor, and compare commanded and actual speed.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
John Deere ECU 001639.16Fan speed high signal
The fan speed reading is high, listed as a fan speed high signal problem; the cause may be the sensor or the fan control. The ECU sees the fan faster than commanded, so the operator hears the fan at full speed and fuel use rises.· OtherOtherCheck soonCauses
- A real high condition on the machine, such as heat, load or restriction, behind the engine cooling fan speed
- The engine cooling fan speed reading high because of a drifting sensor
- Cooling, intake or supply problem that pushes the value up
Checks
- 1Confirm the real value with an independent gauge or thermometer before blaming the engine cooling fan speed
- 2Look for related codes and for a physical cause such as a blocked cooler or restriction
- 3Compare commanded and actual fan speed; if the actual is high with a low command, the control valve is stuck open.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
John Deere ECU 001639.18Fan speed low: moderately severe level
The ECU sees fan speed low at the moderately severe level and treats it as the earlier warning of a fan fault; the source sends you to the fan speed low diagnosis. The ECU sees the fan slower than commanded, so coolant and hydraulic oil temperatures climb.· OtherOtherCheck soonCauses
- A real low condition on the machine, such as low level, low pressure or a cold engine, behind the engine cooling fan speed
- The engine cooling fan speed reading low because of a drifting sensor
- Supply or feed problem that holds the value down
Checks
- 1Confirm the real value with an independent gauge or by inspection before blaming the engine cooling fan speed
- 2Look for related codes and for a physical cause such as a low level, leak or weak supply
- 3Check for a blocked cooler, low hydraulic supply to the fan motor, and compare commanded and actual speed.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
John Deere ECU 003511.03Fan speed sensor voltage high
The ECU reads the fan speed sensor signal above its normal range, usually a short to supply voltage. Fan speed feedback is lost, so the ECU may run the fan wrongly and the engine may derate. The speed sensor feeds fan closed loop control, so with it faulty the fan runs at a fixed speed.· Shorted highShorted highCheck soonCauses
- Sensor signal wire shorted to the supply wire in the fan harness
- Fan speed sensor failed with its output stuck high
- Water in the sensor connector bridging supply and signal
Checks
- 1Unplug the sensor and measure the signal pin voltage at the harness with the key on
- 2Check the sensor ground wire continuity to the engine ECU
- 3Inspect the sensor connector for water and green corrosion
- 4Watch the live fan speed while the fan turns; a sensor that reads zero with a turning fan is the fault.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
John Deere ECU 003511.04Fan speed sensor voltage low
The ECU reads the fan speed sensor signal below its normal range, usually an open circuit or short to ground. Fan speed feedback is lost and the engine may derate or run the fan at the wrong speed. The speed sensor feeds fan closed loop control, so with it faulty the fan runs at a fixed speed.· Shorted lowShorted lowCheck soonCauses
- Open sensor signal wire
- Signal wire shorted to ground against the fan shroud or frame
- No supply to the sensor from a broken wire or backed-out pin
Checks
- 1Check the supply voltage at the sensor connector with the key on
- 2Check the signal wire continuity from the sensor to the ECU
- 3Check the signal wire for a short to ground with the ECU end disconnected
- 4Watch the live fan speed while the fan turns; a sensor that reads zero with a turning fan is the fault.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
John Deere ECU 005484.05Reversing fan solenoid (Y9) open circuit
The ECU sees an open circuit in the reversing fan solenoid (Y9) circuit. The fan may not reverse to blow out the radiator, and cooling can suffer in dusty work. Solenoid Y9 reverses the fan to blow out the radiator, so cleaning by reversing is lost.· Open circuitOpen circuitCheck soonCauses
- Y9 on-off coil open inside, so the reverse valve never shifts
- Y9 wire broken or the plug loose, most often where the harness is clamped near the fan shroud
- Blown fuse in the Y9 supply
Checks
- 1Measure the Y9 coil resistance with the plug removed; an open reading means the coil has failed
- 2Check the Y9 wiring continuity from the plug to the ECU pin, flexing the harness near the fan
- 3Check the fuse in the Y9 supply circuit for a blown element
- 4Measure the Y9 coil resistance and check its fuse; operate the reverse switch and listen for the valve.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
John Deere ECU 005484.06Reversing fan solenoid (Y9) short circuit
The ECU sees a short circuit in the reversing fan solenoid (Y9) circuit. The fan may not reverse correctly, and the short can blow a fuse or damage the ECU output. Solenoid Y9 reverses the fan to blow out the radiator, so cleaning by reversing is lost.· Lost messageLost messageCheck soonCauses
- Y9 coil windings shorted, so it draws more current than the ECU output allows
- Y9 feed wire rubbed bare against the fan shroud or frame and grounded
- Water in the Y9 plug on the fan drive valve
Checks
- 1Measure the Y9 coil resistance with the plug removed and compare it with a good coil
- 2Disconnect Y9 and see whether the short code clears; if it does, the fault is in the coil or its plug
- 3Check the Y9 wires for a short to ground with the ECU end unplugged
- 4Measure the Y9 coil resistance and check its fuse; operate the reverse switch and listen for the valve.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
John Deere MCZ 11412.02Hydraulic fan control solenoid feedback current abnormal
The current feedback of the hydraulic fan control solenoid is abnormal: the controller sees the drive current leaving its allowed band, so the valve does not move as commanded. The hydraulic fan control solenoid sets fan motor speed from the MCZ, so fan speed does not follow load.· OtherOtherCheck soonCauses
- Faulty coil or damaged wiring at the hydraulic fan control solenoid
- Corroded or loose connector pin raising the circuit resistance
- Controller output stage not driving correctly
Checks
- 1Measure the hydraulic fan control solenoid coil resistance at its plug and compare it with the manual value
- 2Check the harness and plug for corrosion, oil and pins that are pushed out
- 3Read the commanded current for the fan control solenoid on the service screen while oil temperature changes.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
John Deere MCZ 11412.03Hydraulic fan control solenoid feedback current high
The feedback current of the hydraulic fan control solenoid is too high, so the coil or its circuit draws more than the controller expects. The hydraulic fan control solenoid sets fan motor speed from the MCZ, so fan speed does not follow load.· Real conditionReal conditionCheck soonCauses
- Shorted turns inside the hydraulic fan control solenoid coil
- Harness shorted to battery voltage or to another wire
- Controller output stage failed on
Checks
- 1Measure the hydraulic fan control solenoid coil resistance; a value far below the manual figure means shorted turns
- 2Check the harness for a short to supply or to a neighbouring wire with both ends unplugged
- 3Read the commanded current for the fan control solenoid on the service screen while oil temperature changes.
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
John Deere MCZ 11412.04Hydraulic fan control solenoid feedback current low
The feedback current of the hydraulic fan control solenoid is too low, so the coil or its circuit carries less current than the controller expects. The hydraulic fan control solenoid sets fan motor speed from the MCZ, so fan speed does not follow load.· Real conditionReal conditionCheck soonCauses
- Open or burnt coil in the hydraulic fan control solenoid
- Corroded connector or broken wire raising the circuit resistance
- Controller output stage not driving
Checks
- 1Measure the hydraulic fan control solenoid coil resistance; an open or very high value means a failed coil
- 2Check the wires and plug for breaks and corrosion with both ends unplugged
- 3Read the commanded current for the fan control solenoid on the service screen while oil temperature changes.
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
John Deere MCZ 11981.02Fan reversing solenoid 2 feedback current abnormal
The current feedback of the fan reversing solenoid 2 is abnormal: the controller sees the drive current leaving its allowed band, so the valve does not move as commanded. Reversing solenoid 2 works with solenoid 1 to reverse the hydraulic fan.· OtherOtherCheck soonCauses
- Faulty coil or damaged wiring at the fan reversing solenoid 2
- Corroded or loose connector pin raising the circuit resistance
- Controller output stage not driving correctly
Checks
- 1Measure the fan reversing solenoid 2 coil resistance at its plug and compare it with the manual value
- 2Check the harness and plug for corrosion, oil and pins that are pushed out
- 3Compare the solenoid 2 coil resistance with solenoid 1; a difference points at the faulty one.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
John Deere MCZ 11981.03Fan reversing solenoid 2 feedback current high
The feedback current of the fan reversing solenoid 2 is too high, so the coil or its circuit draws more than the controller expects. Reversing solenoid 2 works with solenoid 1 to reverse the hydraulic fan.· Real conditionReal conditionCheck soonCauses
- Shorted turns inside the fan reversing solenoid 2 coil
- Harness shorted to battery voltage or to another wire
- Controller output stage failed on
Checks
- 1Measure the fan reversing solenoid 2 coil resistance; a value far below the manual figure means shorted turns
- 2Check the harness for a short to supply or to a neighbouring wire with both ends unplugged
- 3Compare the solenoid 2 coil resistance with solenoid 1; a difference points at the faulty one.
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
John Deere MCZ 11981.04Fan reversing solenoid 2 feedback current low
The feedback current of the fan reversing solenoid 2 is too low, so the coil or its circuit carries less current than the controller expects. Reversing solenoid 2 works with solenoid 1 to reverse the hydraulic fan.· Real conditionReal conditionCheck soonCauses
- Open or burnt coil in the fan reversing solenoid 2
- Corroded connector or broken wire raising the circuit resistance
- Controller output stage not driving
Checks
- 1Measure the fan reversing solenoid 2 coil resistance; an open or very high value means a failed coil
- 2Check the wires and plug for breaks and corrosion with both ends unplugged
- 3Compare the solenoid 2 coil resistance with solenoid 1; a difference points at the faulty one.
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
John Deere MCZ 11982.02Fan reversing solenoid 1 feedback current abnormal
The current feedback of the fan reversing solenoid 1 is abnormal: the controller sees the drive current leaving its allowed band, so the valve does not move as commanded. Reversing solenoid 1 is the first of two valves that reverse the hydraulic fan.· OtherOtherCheck soonCauses
- Faulty coil or damaged wiring at the fan reversing solenoid 1
- Corroded or loose connector pin raising the circuit resistance
- Controller output stage not driving correctly
Checks
- 1Measure the fan reversing solenoid 1 coil resistance at its plug and compare it with the manual value
- 2Check the harness and plug for corrosion, oil and pins that are pushed out
- 3Test solenoid 1 first, then compare its coil resistance with solenoid 2, which should match.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
John Deere MCZ 11982.03Fan reversing solenoid 1 feedback current high
The feedback current of the fan reversing solenoid 1 is too high, so the coil or its circuit draws more than the controller expects. Reversing solenoid 1 is the first of two valves that reverse the hydraulic fan.· Real conditionReal conditionCheck soonCauses
- Shorted turns inside the fan reversing solenoid 1 coil
- Harness shorted to battery voltage or to another wire
- Controller output stage failed on
Checks
- 1Measure the fan reversing solenoid 1 coil resistance; a value far below the manual figure means shorted turns
- 2Check the harness for a short to supply or to a neighbouring wire with both ends unplugged
- 3Test solenoid 1 first, then compare its coil resistance with solenoid 2, which should match.
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
John Deere MCZ 11982.04Fan reversing solenoid 1 feedback current low
The feedback current of the fan reversing solenoid 1 is too low, so the coil or its circuit carries less current than the controller expects. Reversing solenoid 1 is the first of two valves that reverse the hydraulic fan.· Real conditionReal conditionCheck soonCauses
- Open or burnt coil in the fan reversing solenoid 1
- Corroded connector or broken wire raising the circuit resistance
- Controller output stage not driving
Checks
- 1Measure the fan reversing solenoid 1 coil resistance; an open or very high value means a failed coil
- 2Check the wires and plug for breaks and corrosion with both ends unplugged
- 3Test solenoid 1 first, then compare its coil resistance with solenoid 2, which should match.
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
John Deere ECU 065372.05Proportional fan speed valve solenoid driver open
The controller detects an open circuit on the variable speed fan solenoid (Y5005), meaning the circuit is broken or the part is disconnected, so its signal is lost. The proportional fan valve solenoid driver is the ECU output for Y5005, so this points at the driver circuit.· Open circuitOpen circuitCheck soonCauses
- Unplugged connector or a terminal pushed out of the variable speed fan solenoid (Y5005) plug
- Broken wire inside the harness to the variable speed fan solenoid (Y5005)
- Open element inside the variable speed fan solenoid (Y5005) itself
Checks
- 1Inspect the variable speed fan solenoid (Y5005) plug for pushed-back terminals, corrosion or a plug that is not fully seated
- 2Measure continuity of the wires from the variable speed fan solenoid (Y5005) plug to the controller with both ends disconnected
- 3Check the Y5005 wiring with both ends unplugged before suspecting the ECU output.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
John Deere ECU 065372.06Proportional fan speed valve solenoid driver short
The controller detects a short circuit on the variable speed fan solenoid (Y5005), so the circuit draws too much current or the signal is pulled to a fixed level. The proportional fan valve solenoid driver is the ECU output for Y5005, so this points at the driver circuit.· Short circuitShort circuitCheck soonCauses
- Wire to the variable speed fan solenoid (Y5005) chafed through and touching ground or a supply wire
- Water or oil inside the variable speed fan solenoid (Y5005) connector bridging pins
- Internal short inside the variable speed fan solenoid (Y5005)
Checks
- 1Unplug the variable speed fan solenoid (Y5005) and see whether the code changes from a short to an open; if it does, the part is the likely culprit
- 2Measure each wire to ground with both ends disconnected; a low reading means a harness short
- 3Check the Y5005 wiring with both ends unplugged before suspecting the ECU output.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the part and the controller. Measure from the output wire to ground and to battery positive, then across the part.
Good: Open circuit (OL) to ground and to supply; the part reads its listed resistance, not near 0 Ω.
Shared checks
Checks, in order
- 1Read the prefix (MCZ or ECU) and which solenoid or sensor the code names before testing
- 2Watch the fan at idle and high idle: a fan that does not change speed points at the control solenoid or drive, not the sensor
- 3Measure the solenoid coil resistance at its unplugged connector and check the harness for a short or break
- 4For speed sensor codes check the air gap, the plug and the live speed reading while the fan turns
- 5Check the cooler for blockage and the coolant and hydraulic oil temperature to see whether a real fan failure is overheating the machine
Causes
- Fan control or reversing solenoid coil open or shorted
- Fan speed sensor shorted, open or damaged by the fan
- Fan motor, pump or drive worn so the speed does not match the command
- Wire rubbed through near the fan, or reversing switch S15 stuck on
Most common here: real condition (6 of 23)
Check the real value with a separate gauge or thermometer before blaming the sensor.
When to stop
You'll notice: The engine or hydraulic oil runs hot because the fan is slow, or the fan is noisy and wastes power when it runs too fast; reverse cleaning may not work and the cooler can clog.
Lower attachments to the ground and relieve hydraulic pressure before loosening any fitting. Never feel for a leak with your hand - oil under pressure can inject through skin.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
- Excavator Fault Codes - John Deere excavators fault codes list (MCZ/ECU/DSZ)
- Inside the Yard - John Deere fault codes list (ECU engine codes)
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.