John Deere · Engine control unit (ECU) - Cooling
John Deere Fault Code ECU 001639.01
Fan speed low
What does John Deere code ECU 001639.01 mean?
The ECU sees fan speed below the commanded value, with zero speed being the most severe case. The operator may see coolant or hydraulic oil temperature rising and the engine may derate. Urgency: check soon - the machine may derate or limit a function. Check first: look at the fan for blockage and spin it by hand with the engine off to feel for a seized bearing.
- ECU
- Which controller reports it
- 001639
- Cooling fan speed
- .01
- Data below normal, most severe
Can I keep running with it?
Check soon
The machine may derate or limit a function. Find the cause before the next shift.
What should I check first?
Look at the fan for blockage and spin it by hand with the engine off to feel for a seized bearing
Then 5 more checksWhere this code shows
Turn the key on and open the monitor's diagnostic/fault screen.
Checks
0 of 6 done
Causes
- Fan blades or drive jammed by debris or a seized bearing
- Fan solenoid open or failed so the fan gets no drive
- Fan speed sensor not reading
- Low hydraulic flow to the fan motor
How it failed
You'll notice: The ECU sees fan speed below the commanded value, with zero speed being the most severe case.
OtherRead from how the source describes the code
The source does not say how this one failed.
- Meter test
- Read the code with the service tool and note which other codes are active with it.
- Good result
- Codes that appear together usually share one cause - start with the wiring they share.
When to stop
Lower attachments to the ground and relieve hydraulic pressure before loosening any fitting. Never feel for a leak with your hand - oil under pressure can inject through skin.
Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Same part, other failures: Cooling fan control, reversing and speed
- ECU 000647.06Variable speed fan solenoid (Y5005) short circuitLost messageCheck soon
- ECU 000647.16Manual purge mode switch active too longOtherCheck soon
- ECU 000647.31Fan manual reverse mode input active too longOtherCheck soon
- ECU 001639.00Fan speed highOtherCheck soon
- ECU 001639.01Fan speed lowOtherCheck soon
- ECU 001639.16Fan speed high signalOtherCheck soon
- ECU 001639.18Fan speed low: moderately severe levelOtherCheck soon
- ECU 003511.03Fan speed sensor voltage highShorted highCheck soon
- ECU 003511.04Fan speed sensor voltage lowShorted lowCheck soon
Show the other 14 codesHide the other codes
- ECU 000647.05Variable speed fan solenoid (Y5005) open circuitOpen circuitCheck soon
- ECU 005484.05Reversing fan solenoid (Y9) open circuitOpen circuitCheck soon
- ECU 005484.06Reversing fan solenoid (Y9) short circuitLost messageCheck soon
- MCZ 11412.02Hydraulic fan control solenoid feedback current abnormalOtherCheck soon
- MCZ 11412.03Hydraulic fan control solenoid feedback current highReal conditionCheck soon
- MCZ 11412.04Hydraulic fan control solenoid feedback current lowReal conditionCheck soon
- MCZ 11981.02Fan reversing solenoid 2 feedback current abnormalOtherCheck soon
- MCZ 11981.03Fan reversing solenoid 2 feedback current highReal conditionCheck soon
- MCZ 11981.04Fan reversing solenoid 2 feedback current lowReal conditionCheck soon
- MCZ 11982.02Fan reversing solenoid 1 feedback current abnormalOtherCheck soon
- MCZ 11982.03Fan reversing solenoid 1 feedback current highReal conditionCheck soon
- MCZ 11982.04Fan reversing solenoid 1 feedback current lowReal conditionCheck soon
- ECU 065372.05Proportional fan speed valve solenoid driver openOpen circuitCheck soon
- ECU 065372.06Proportional fan speed valve solenoid driver shortShort circuitCheck soon
Related on Equipments Finder
Source
Excavator Fault Codes - John Deere excavators fault codes list (MCZ/ECU/DSZ)
This source lists ECU 001639.01 and its meaning. The guidance on this page is general, not taken from it.
The source covers: John Deere G-series excavators (210G/210GLC and 350G class) with MCZ main controller; confirm against serial number.
Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.