JLG Footswitch, joysticks, steer switches and start sequence fault codes
These are the operator inputs of a JLG boom lift: the footswitch and keyswitch, the drive and steer joystick, the lift and swing joystick, the steer switches, the function switches with the ground enable, and the start-up order checks that lock a switch out if it was used too early. The platform and ground modules read each one and report a fault when a contact disagrees with its partner, sticks, or is used out of sequence.
Where this code shows
Turn the key on and watch the fault lamp or platform display.
What do these codes mean?
JLG codes 2-1 to 2310 are all about the footswitch, joysticks, steer switches and start sequence. The most common failure type is real condition (4 of 26); none needs an immediate stop. Start with this check: read the Help message on the analyzer to see which input is named.
How urgent are they?
None of the 26 codes here means stop now; 24 can wait until the shift ends, but find the cause before the next one; 2 are information only.
- Check soon24
- Info2
What should I check first?
Read the Help message on the analyzer to see which input is named
Shared checks26 of 26
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
JLG 2-1Footswitch or keyswitch fault
The controller sees the two footswitch contacts reading the same state for over a second, or the keyswitch input is invalid. Platform functions are blocked until it is cleared; a footswitch fault needs the red EMS button recycled.· Real conditionReal conditionCheck soonCauses
- Footswitch with one contact stuck or worn so both channels agree
- Broken or pinched footswitch cable inside the platform control box
- Corroded platform module connector at the footswitch input
- Keyswitch contacts worn or key left between positions
- Platform module input damaged (rare)
Checks
- 1Read the Help message on the analyzer: FSW FAULTY or KEYSWITCH FAULTY
- 2Open the platform box and check the two footswitch wires change state opposite to each other when pressed and released
- 3Ohm the footswitch cable end to end and wiggle it while watching the analyzer
- 4Clean and reseat the platform module connector
- 5Cycle the EMS button, then retest; replace the footswitch if the fault returns
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
JLG 2-2Drive or steer selection fault
The drive or steer inputs are in a state the controller will not accept: joystick moved before the footswitch, steer selected before the footswitch, both steer switches active, or the joystick signal out of range. Most clear on their own once the input is released.· OtherOtherCheck soonCauses
- Operator moved the drive joystick or steer switch before pressing the footswitch
- Footswitch held closed about 7 seconds with nothing selected
- Drive joystick centre tap voltage outside its window (resistive about 3.08-3.83 V, inductive about 2.18-2.70 V)
- Q-Prox sensor on an inductive joystick reading above about 3.18 V, or joystick not neutral
- Steer rocker switches stuck or wiring shorted
Checks
- 1Release everything, let the footswitch open, then press the footswitch first and select drive after
- 2Read the Help message to see which variant it is (D/S JOY. CENTER TAP BAD, OUT OF RANGE, STEER SWITCHES FAULTY)
- 3Measure joystick supply and centre tap at the platform module with the joystick untouched
- 4Check the 7 V sensor reference is steady and not shorted
- 5Replace the drive joystick if the centre tap stays out of window
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JLG 2-3Boom function selection fault
A boom function (lift, swing, telescope, jib, level, rotate) was selected in the wrong order or its joystick or switch is bad: both directions at once, selected before key or footswitch, or selected before aux power. Lift/swing joystick faults also report here.· OtherOtherCheck soonCauses
- Function switch or lift/swing joystick moved before the footswitch or key was on
- Both directions of one function closed together (stuck rocker)
- Lift/swing joystick centre tap out of window or Q-Prox sensor fault
- Ground function selected before aux power was applied
- Water in the platform control box shorting switch inputs
Checks
- 1Release all functions, cycle the footswitch and retry in the correct order
- 2Use the analyzer diagnostics menu to find which input shows active with nothing pressed
- 3Check the suspect switch contacts with a meter at the platform box terminals
- 4Measure the lift/swing joystick centre tap at rest
- 5Dry out and reseal the platform box; replace the joystick or switch found faulty
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JLG 2-4Steering digital inputs faulty
The steering digital inputs do not make sense to the controller. The manual lists this flash code without extra help text.· OtherOtherCheck soonCauses
- Steer rocker or switch contacts worn so both directions read as pressed
- Platform harness chafed or pinched near the steer switch
- Moisture or corrosion in the platform control box on the steer inputs
- Steer input stuck active from a failed rocker spring
Checks
- 1Read the Help message on the analyzer and note which steer input is named
- 2Open the diagnostics screen and watch both steer inputs while the switch is pushed each way
- 3Ohm the steer switch in each position with the wires removed; the two inputs should never read closed together
- 4Inspect the platform harness connector for water, loose pins and rub marks on the cable
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JLG 2-7Accelerator input faulty
The ground or platform module sees the accelerator (throttle) input as invalid, so it cannot trust the engine speed request. The operator may find the engine stuck at idle or at one speed. The manual lists the flash code with no further Help text.· OtherOtherCheck soonCauses
- Throttle or accelerator switch/pot with a worn or open contact
- Harness between the throttle device and the platform or ground module chafed or broken
- Corroded or loose pin in the module connector for the throttle input
- Throttle actuator or its feedback circuit damaged on the engine
- Module input stage damaged (least likely)
Checks
- 1Plug in the analyzer, read the Help message and note which module (ground or platform) is reporting the accelerator input
- 2Open the analyzer diagnostics and watch the throttle input while moving the throttle switch through each position; it should change cleanly
- 3With the connector unplugged, check the wires from the throttle device to the module pins for continuity and for shorts to each other or to chassis
- 4Clean and reseat the module connector, looking for pushed-back or green pins at the throttle input
- 5Swap in a known good throttle switch or pot to separate a device fault from a wiring fault, and replace the faulty part
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JLG 0011Footswitch open
The controller reports the footswitch input as open, which is the normal state with the pedal released. It is shown as a status line to tell you platform functions are disabled until the pedal is pressed.· OtherOtherInfoCauses
- Pedal released as normal
- Pedal contacts or cable open so the controller never sees it closed
Checks
- 1Press the pedal and watch the footswitch input in the analyzer change to closed
- 2If it never closes, ohm the pedal cable and check the plug in the platform box
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JLG 213Footswitch faulty
The two footswitch signals have been in the same state for too long, so the controller judges the footswitch faulty. Platform functions are locked out and the EMS must be recycled to clear the fault.· OtherOtherCheck soonCauses
- Footswitch contact stuck or worn so both signals match
- Footswitch cable pinched or broken inside the platform box
- Platform module connector corroded at the footswitch pins
- Water in the platform control box
- Platform module input fault
Checks
- 1Watch both footswitch inputs in the analyzer diagnostics; they should switch in opposite states as the pedal is pressed and released
- 2Ohm each footswitch contact in both positions with the cable disconnected from the module
- 3Flex the footswitch cable along its length while watching the analyzer for dropouts
- 4Open the platform box and check for water, corrosion and loose pins on the connector
- 5Recycle the EMS button, retest, and replace the footswitch if the fault comes back
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JLG 224Function problem - Steer left permanently selected
The steer left input reads as selected with nobody pressing it, so the controller treats it as stuck on and may block steering or other functions.· OtherOtherCheck soonCauses
- Steer left switch jammed or sticking
- Steer left wire shorted to a supply wire
Checks
- 1Release the switch and read the steer left input in the analyzer
- 2Unplug the switch and see whether the input clears
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JLG 225Function problem - Steer right permanently selected
The steer right input reads as selected with nobody pressing it, so the controller treats it as stuck on and may block steering or other functions.· OtherOtherCheck soonCauses
- Steer right switch jammed or sticking
- Steer right wire shorted to a supply wire
Checks
- 1Release the switch and read the steer right input in the analyzer
- 2Unplug the switch and see whether the input clears
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JLG 227Steer switches faulty
The controller finds the steer switch pair unreliable, for example left and right selected together, so steering is blocked until the inputs read sensibly.· Real conditionReal conditionCheck soonCauses
- Left and right wires shorted together
- Switch damaged so both contacts close together
Checks
- 1Check that only one steer input changes when each direction is pressed
- 2Check the switch wiring between the switch and the module
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
JLG 234Function switches faulty - Check diagnostics/boom
The controller thinks the function switches are faulty and tells you to check the boom function menu in diagnostics. One or more boom functions may be blocked, for example a switch reading on with nothing pressed.· Real conditionReal conditionCheck soonCauses
- Function switch stuck in the on position
- Water in the platform control box
- Harness short between two function switch wires
- Corroded connector at the platform module
Checks
- 1Open the analyzer diagnostics boom menu and look for any input showing active with nothing pressed
- 2Press each function switch and watch its input change, noting any that stay on or flicker
- 3Check the offending switch with a meter for continuity in each position
- 4Open the platform box, look for moisture and corrosion, and dry and reseal it
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
JLG 235Function switches locked - Selected before aux power
A function switch was selected before auxiliary power was switched on, so the controller locks that function until everything is released and the aux power sequence is repeated.· OtherOtherCheck soonCauses
- Function switch held while aux power was being selected
- Aux power switch contact slow to close so the function input arrives first
Checks
- 1Release the function switches, select aux power, then select the function
- 2Read the aux power input in the analyzer while operating the switch to confirm it registers cleanly
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JLG 236Function switches locked - Selected before start switch
A function switch was selected before the start switch was used, so the controller locks it until switches are released and the start sequence repeated.· OtherOtherCheck soonCauses
- Function switch left selected while the start switch was operated
- Start switch contacts dirty so it registers after the function
Checks
- 1Release all function switches, press start, then select the function
- 2Read the start input in the analyzer and check it changes the moment the switch is pressed
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JLG 237Start switch locked - Selected before keyswitch
The start switch was selected before the keyswitch was in position, so the start is locked until the switches are released and the key used first.· OtherOtherCheck soonCauses
- Start switch held while the key was still being turned
- Keyswitch slow to reach its run position because of worn contacts
Checks
- 1Release the start switch, turn the key fully to run, then press start
- 2Read the keyswitch input in the analyzer and check it shows on before the start input changes
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JLG 2211Footswitch interlock tripped
The footswitch interlock tripped, for example the footswitch was closed with no function selected for too long, or closed at an unexpected time. Functions stay blocked until the operator releases the footswitch and starts again.· Real conditionReal conditionCheck soonCauses
- Footswitch held down at power-up or for too long with nothing selected
- A joystick or function switch stuck in a selected state
- Worn footswitch contact making a noisy, on-off signal
- Water or corrosion in the platform control box
- Footswitch cable chafed where it enters the box
Checks
- 1Release the footswitch and the stick, cycle power and retry in the right order
- 2Open the analyzer diagnostics and check that no function input is active with everything released
- 3Ohm and flex the footswitch cable and contacts for an intermittent break
- 4Inspect the platform box for moisture and reseat the module connector
- 5Replace the footswitch or the stuck function switch if the fault repeats
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
JLG 2212Drive locked - Joystick moved before footswitch
The drive stick was off centre when the footswitch was pressed, so the controller locked drive until you let go of the stick and start again in order.· OtherOtherCheck soonCauses
- Operator put the drive stick forward while the foot was still off the pedal
- Drive stick not centring because its spring or boot is binding
Checks
- 1Return the drive stick to centre, release the pedal and press the pedal first before moving the stick
- 2With the stick at rest read the drive axis in the analyzer; any value away from zero means the stick itself is the fault
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JLG 2213Steer locked - Selected before footswitch
A steer switch was already pressed when the footswitch went down, so the controller locked steering until all steer switches are released and the pedal sequence is repeated.· OtherOtherCheck soonCauses
- Steer thumb switch on the drive stick pressed or sticking as the pedal went down
- Steer rocker contact closed by dirt so it looks pressed at start-up
Checks
- 1Release both steer switches, release the pedal, then press the pedal before steering
- 2Read the steer inputs at rest in the analyzer and find the one showing selected
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JLG 2216Drive/steer joystick out of range high
The drive/steer joystick signal is above its valid window, for example because the sensor reference is out of tolerance or a signal wire is shorted to battery. Drive and steer are blocked until the signal returns to range.· Shorted highShorted highCheck soonCauses
- Drive joystick signal wire touching the battery supply at the joystick plug or in the platform cable
- 7 V sensor reference pulled out of tolerance by a short on another sensor sharing the feed
- Drive joystick damaged internally and reading above its window with the stick released
- Cable chafed where it enters the platform control box
Checks
- 1Read the drive joystick signal and the reference in the analyzer and compare with the manual values for a resistive or inductive joystick
- 2Measure the reference at the platform module; unplug other sensors on the same feed to find a short pulling it off
- 3Inspect the joystick cable and connector for a pin touching the supply
- 4Check the output with the stick released and then moved; it should rise smoothly
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
JLG 2217Drive/steer joystick centre tap bad
The drive/steer joystick centre tap is outside its allowed window (resistive about 3.08-3.83 V, inductive about 2.18-2.70 V). The controller will not trust the stick, so drive and steer are locked out.· OtherOtherCheck soonCauses
- Drive stick spring or boot damaged, so the stick does not come back to the exact neutral point the controller wants
- Worn track or sensor in the drive joystick, giving a centre voltage outside about 3.08-3.83 V on a resistive stick or 2.18-2.70 V on an inductive one
- Corroded pins at the drive joystick plug adding resistance to the centre-tap wire
- Platform module reference supply too high or too low, shifting the whole window
Checks
- 1Let go of the drive stick and read the centre tap in diagnostics, then compare with the window for the joystick fitted
- 2Push the stick through neutral by hand and see whether the boot or the spring holds it off centre
- 3Measure the reference supply at the platform module with the stick untouched
- 4Look at the drive joystick plug and the platform module pins for green corrosion
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JLG 2219Lift/swing joystick out of range high
The lift/swing joystick signal is above its valid window, so the controller blocks boom lift and swing until it returns to range. The operator finds the boom functions dead from the platform.· OtherOtherCheck soonCauses
- Lift/swing stick signal wire touching battery supply inside the platform control box
- Shared sensor reference out of tolerance because of a short elsewhere on the same feed
- Lift/swing joystick failed internally and now reads high even when released
- Platform box cable or connector damaged, putting a live pin against the signal pin
Checks
- 1With the stick released, read the lift/swing signal in diagnostics and compare it with the manual values for the fitted joystick
- 2Unplug other sensors one at a time while watching the reference at the platform module to find a short dragging it up
- 3Inspect the lift/swing joystick cable and plug for a chafed wire against a supply
- 4Move the stick slowly through its travel; the reading should move smoothly and not jump in steps
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JLG 2220Lift/swing joystick centre tap bad
The lift/swing joystick centre tap is outside its allowed voltage window, so the controller will not accept the stick as neutral. Lift and swing from the platform are locked out until it is fixed.· OtherOtherCheck soonCauses
- Boom joystick that no longer centres, with a weak spring or a boot caught by the control box
- Track or sensor inside the lift/swing joystick worn, giving a centre voltage outside the window
- High resistance in the lift/swing joystick plug or the wires to the platform module
- Reference supply to the sensor off from a fault on the same feed
Checks
- 1Release the lift/swing stick and read its centre tap in diagnostics against the window for the fitted joystick
- 2Make sure the stick returns freely to neutral and nothing in the control box is pressing on it
- 3Measure the sensor reference at the platform module with the stick at rest
- 4Check the plug and wires between the joystick and the platform module for corrosion and a backed-out pin
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JLG 2221Lift/swing locked - Joystick moved before footswitch
The lift and swing stick was off centre when the footswitch was pressed, so lift and swing stay locked until the stick is released and the sequence repeated.· OtherOtherCheck soonCauses
- Operator moved the lift or swing stick before the pedal was pressed
- Lift and swing stick not springing back to its centre notch
Checks
- 1Centre the lift and swing stick, lift your foot and press the pedal before touching the stick
- 2Watch the lift and swing axes in the analyzer with the stick released; they should rest at zero
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JLG 2222Waiting for footswitch to be open
The controller will not carry on until the footswitch is released, which makes the operator lift off the pedal before starting again. It appears after a lockout or at power-up with the pedal held.· OtherOtherInfoCauses
- Pedal held down at power-up or after a lockout
- Pedal contacts stuck closed
Checks
- 1Take your foot off the pedal and wait for the message to clear
- 2If the input stays closed with the pedal released, test the pedal and its cable
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JLG 2223Function switches locked - Selected before enable
A function switch was selected before the enable was given, so the controller locks that function until everything is released and enable is applied first.· OtherOtherCheck soonCauses
- Function rocker held while the enable trigger was still open
- Enable trigger worn so it registers late compared with the function switch
Checks
- 1Release every function switch, press the enable, then select the function
- 2Read the enable input in the analyzer while squeezing the trigger and watch whether it changes before the function input does
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JLG 2224Footswitch selected before start
The footswitch was pressed before the start sequence was complete, so platform functions stay locked until the pedal is released and the start repeated.· OtherOtherCheck soonCauses
- Operator standing on the pedal while turning the key or pressing start
- Footswitch contact stuck closed so it looks pressed at power-up
Checks
- 1Take your foot off the pedal, cycle the key and start, then press the pedal last
- 2With the key on and nobody on the pedal read the footswitch input; if it shows pressed the footswitch is the fault
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JLG 2310Function problem - Ground enable permanently selected
The ground enable input reads as selected while nobody is pressing it, so the controller treats it as stuck on and may lock ground control functions or the platform sequence.· OtherOtherCheck soonCauses
- Ground enable switch jammed or not returning
- Ground enable wire shorted to a supply wire
Checks
- 1With everything released, read the ground enable input in the analyzer and see whether it shows selected
- 2Unplug the enable switch; if the input clears the switch is at fault, if not suspect the wiring or module
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Shared checks
Checks, in order
- 1Read the Help message on the analyzer to see which input is named
- 2Release every stick, switch and the pedal, cycle the key and repeat the start-up in the right order
- 3With all controls at rest read the input in the analyzer; one that does not rest at zero is the faulty part
- 4Open the control box and look for moisture, bent levers, pinched cable and green pins
- 5Replace the part that disagrees with its partner, then cycle EMS
Causes
- A worn or jammed footswitch, joystick or rocker that no longer returns to centre
- Broken or pinched cable inside the platform control box
- Corroded connector at the platform module input
- Operator selecting a function before the step it depends on (key, start, enable, pedal)
Most common here: real condition (4 of 26)
Check the real value with a separate gauge or thermometer before blaming the sensor.
When to stop
You'll notice: The platform controls go dead or one function stays locked while the fault lamp flashes the code.
Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
- JLG 600S/660SJ Service and Maintenance Manual 3121298, section 6 (Table 6-8 Fault Code List)
- JLG 600S/600SJ/660SJ/600A/AJ Service and Maintenance Manual 3120840, section 6 (Tables 6-3, 6-5)
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.