JCB · Communication (CAN / telematics)
JCB CAN bus, module communication and LiveLink telematics fault codes
These codes report a general CAN bus fault such as a bus-off state or timeout, lost communication with the EGR, turbo or other control modules, or an ECU that is not bound to the machine. The LiveLink unit is JCB's telematics box with a modem, GPS and SIM.
More about these partsLess
These codes report problems with its power, antenna, SIM or network.
Where this code shows
Switch the key on and note any warning lamp or fault icon on the cluster.
What do these codes mean?
JCB codes U0002 to U2106 are all about the cAN bus, module communication and LiveLink telematics. The most common failure type is lost message (12 of 27); none needs an immediate stop. Start with this check: check the CAN high and low wiring for opens, shorts and water.
How urgent are they?
None of the 27 codes here means stop now; 16 can wait until the shift ends, but find the cause before the next one; 11 are information only.
- Check soon16
- Info11
What should I check first?
Check the CAN high and low wiring for opens, shorts and water
Shared checks27 of 27
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
JCB U0002ISO-CAN bus fault
A controller reports a general fault on the ISO CAN bus. Messages are lost or corrupted across the whole bus, so more than one module may complain at the same moment.· Lost messageLost messageCheck soonCauses
- Open or shorted CAN high or CAN low wire
- Missing or faulty terminating resistor at either end of the bus
- A module pulling the bus down after an internal failure
Checks
- 1Measure resistance between CAN high and CAN low with the system powered down and compare it with the combined terminator value
- 2Unplug modules one at a time to find one that drags the bus down
- 3Inspect connectors and splices on the CAN trunk for water or corrosion
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB U010ALost communication with EGR control module A
The engine ECU lost communication with the EGR control module. The module is either not powered, not reachable on the bus or not sending data.· Lost messageLost messageCheck soonCauses
- EGR control module without supply or earth
- CAN wiring to the EGR module open or loose
Checks
- 1Check the EGR module supply, earth and connector
- 2Check CAN continuity to the module
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB U010CLost communication with turbocharger control module A
The engine ECU lost communication with the turbocharger control module that drives the variable-geometry actuator. It is a data fault on that module's CAN link.· Lost messageLost messageCheck soonCauses
- Turbocharger control module without power
- CAN link to the module damaged or loose
- Module failed internally
Checks
- 1Check the turbocharger actuator module supply, earth and connector
- 2Check CAN continuity and the termination between the module and the engine ECU
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB U0029-87CAN bus communication failure at 250 kbps
The machine's CAN network, which runs at 250 kbps, has lost communication. This code reports the message timeout form of that fault.· Lost messageLost messageCheck soonCauses
- Wiring fault on the 250 kbps CAN trunk
- A module on the bus not powered or stuck in reset
Checks
- 1Check CAN high and low continuity and the termination resistors
- 2Check that each module on the bus has power and earth
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB U0029-88CAN bus communication failure at 250 kbps (code 88)
The same 250 kbps CAN communication failure as U0029-87, recorded under suffix 88. The source lists it separately; the repair is the same: find the bus wiring or module fault.· Lost messageLost messageCheck soonCauses
- Wiring fault on the CAN trunk
- A module on the bus not powered or in reset
Checks
- 1Compare which controllers report the fault under -87 and -88 and look for the one they have in common
- 2Inspect CAN connectors for water or corrosion
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB U040BCAN communication error, EGR overtemperature
A CAN communication error was raised together with an EGR overtemperature condition. The data about the hot EGR was not received properly, so check both the bus and the EGR cooler.· Lost messageLost messageCheck soonCauses
- CAN message about EGR temperature not received
- Overheating EGR cooler genuinely reporting high temperature
Checks
- 1Read the EGR temperature on live data to see whether the value is real
- 2Check CAN wiring between the EGR module and the engine ECU
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB U040DInvalid data from turbocharger control module A
The turbocharger control module sent data that the engine ECU judged invalid. The module is talking but the content makes no sense.· OtherOtherCheck soonCauses
- Turbocharger control module sending corrupted data
- Intermittent CAN fault on the module link
Checks
- 1Check the turbocharger actuator supply voltage and its connector
- 2Read the turbo module's own fault list for internal faults
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB U040FEngine rating mismatch
The engine rating stored in the engine ECU does not match what another controller expects. This is a configuration mismatch, not a wiring fault.· OtherOtherCheck soonCauses
- Wrong software or rating file loaded in one of the controllers
- A replaced controller not programmed for this machine
Checks
- 1Compare the engine rating and software versions in each controller with the machine's data plate or service tool
- 2Reprogram the replaced controller with the right file
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB U0073Control module communication bus A off
The control module communication bus A has gone off: a controller disconnected itself from the bus after repeated errors, so other controllers stop hearing from it.· Open circuitOpen circuitCheck soonCauses
- Short between CAN high and CAN low
- Bus A wiring open at a connector
- Faulty module sending constant errors
Checks
- 1Measure the CAN voltages with the key on and look for a bus stuck at one level
- 2Disconnect modules one at a time and watch whether the bus recovers
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
JCB U0101CAN timeout fault
A controller waited for a CAN message from another controller and nothing arrived in time. A wiring break, a module without power or one that has reset can cause the timeout.· Lost messageLost messageCheck soonCauses
- Sending controller without power or earth
- CAN wiring break or loose connector
Checks
- 1Check fuses and supply to the controller that should be sending the message
- 2Wiggle the CAN connectors while watching whether communication returns
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB U0110Inducement BAM time-out fault
The inducement message from the aftertreatment controller to the engine ECU timed out, so the engine cannot be told the state of inducement and the derate function may misbehave.· Lost messageLost messageCheck soonCauses
- CAN link between the aftertreatment controller and the engine ECU interrupted
- Aftertreatment controller reset or without power
Checks
- 1Check the aftertreatment controller supply and CAN wiring
- 2Compare the message timing in the diagnostic tool if it can show the bus traffic
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB U190ALiveLink SIM card failure
LiveLink SIM card failure. The controller logged a fault on the liveLink SIM card failure, which affects how the LiveLink telematics unit works until the cause is found.· OtherOtherInfoCauses
- LiveLink SIM card failure or its wiring faulty
- Connector corrosion or a loose pin
Checks
- 1Read the live data for the liveLink SIM card failure and look for a value that is stuck or implausible
- 2Check the liveLink SIM card failure connector and wiring for damage
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB U190BLiveLink loss of communication with GSM module
LiveLink loss of communication with GSM module. The controller did not receive a valid message or lost contact on the bus, so data for the LiveLink telematics unit is missing or unreliable.· OtherOtherInfoCauses
- CAN wiring open, shorted or wet at a connector
- The sending module not powered, reset or faulty
Checks
- 1Check the CAN high and low wiring and the 120 ohm termination
- 2Check that the sending module has power, earth and no active faults of its own
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB U190CLiveLink GSM network registration failure
LiveLink GSM network registration failure. The controller logged a fault on the liveLink GSM network registration failure, which affects how the LiveLink telematics unit works until the cause is found.· Lost messageLost messageInfoCauses
- LiveLink GSM network registration failure or its wiring faulty
- Connector corrosion or a loose pin
Checks
- 1Read the live data for the liveLink GSM network registration failure and look for a value that is stuck or implausible
- 2Check the liveLink GSM network registration failure connector and wiring for damage
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB U0410VNT communication fault
Communication with the variable-nozzle turbocharger (VNT) actuator failed. The ECU cannot command vane position, so boost control falls back to a default.· Lost messageLost messageCheck soonCauses
- VNT actuator connector or wiring damaged
- Actuator electronics failed
Checks
- 1Check the VNT actuator connector and wiring
- 2Run the actuator test with the diagnostic tool
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB U1100Communication failure between systems
A controller reported a communication failure between two systems on the machine, without naming which. Find the controllers that disagree.· OtherOtherCheck soonCauses
- Wiring problem between the two systems
- One of the two controllers not powered
Checks
- 1Read the fault lists from all controllers to find which two lost contact
- 2Check power and earth to each of them
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB U1300ECU binding fault
The engine ECU is not bound to the machine controller, a security pairing that must match after a replacement. The engine may not start or may be limited until the pairing is redone.· OtherOtherCheck soonCauses
- Engine ECU or machine controller replaced and not paired
- Pairing data corrupted
Checks
- 1Perform the ECU binding or matching procedure with the service tool
- 2Check you are binding the correct controllers for this machine
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB U1800ECU binding fault
The same ECU binding fault as U1300, recorded under a different code number. The two controllers do not recognise each other until the binding is redone.· OtherOtherCheck soonCauses
- ECU or machine controller replaced and not paired
- Binding data lost after reprogramming
Checks
- 1Repeat the binding procedure and read both codes again
- 2Confirm the part numbers of both controllers match the machine
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB U1900LiveLink vehicle battery voltage below normal
LiveLink vehicle battery voltage below normal. The reading or voltage for the liveLink vehicle battery voltage below normal is below the allowed range, so the controller treats the signal as unreliable.· Shorted lowShorted lowInfoCauses
- LiveLink vehicle battery voltage below normal signal pulled low by a short to ground or an open supply
- Sensor or part failed giving a low reading
Checks
- 1Read the liveLink vehicle battery voltage below normal value on live data and compare it with the expected value
- 2Unplug the liveLink vehicle battery voltage below normal and check the signal wire for a short to ground and the supply for 5 V
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
JCB U1901LiveLink ECU internal voltage below normal
LiveLink ECU internal voltage below normal. The reading or voltage for the liveLink ECU internal voltage below normal is below the allowed range, so the controller treats the signal as unreliable.· Shorted lowShorted lowInfoCauses
- LiveLink ECU internal voltage below normal signal pulled low by a short to ground or an open supply
- Sensor or part failed giving a low reading
Checks
- 1Read the liveLink ECU internal voltage below normal value on live data and compare it with the expected value
- 2Unplug the liveLink ECU internal voltage below normal and check the signal wire for a short to ground and the supply for 5 V
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
JCB U1904LiveLink ECU above temperature threshold
LiveLink ECU above temperature threshold. The reading or voltage for the liveLink ECU above temperature threshold is above the allowed range, so the controller treats the signal as unreliable.· OtherOtherInfoCauses
- LiveLink ECU above temperature threshold signal pulled high by a short to the 5 V reference or supply
- Sensor or part failed giving a high reading
Checks
- 1Read the liveLink ECU above temperature threshold value on live data and compare it with the expected value
- 2Unplug the liveLink ECU above temperature threshold and check the signal wire for a short to 5 V or battery
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB U1905LiveLink ECU below temperature threshold
LiveLink ECU below temperature threshold. The reading or voltage for the liveLink ECU below temperature threshold is below the allowed range, so the controller treats the signal as unreliable.· OtherOtherInfoCauses
- LiveLink ECU below temperature threshold signal pulled low by a short to ground or an open supply
- Sensor or part failed giving a low reading
Checks
- 1Read the liveLink ECU below temperature threshold value on live data and compare it with the expected value
- 2Unplug the liveLink ECU below temperature threshold and check the signal wire for a short to ground and the supply for 5 V
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB U1906LiveLink accelerometer internal failure
LiveLink accelerometer internal failure. The controller logged a fault on the liveLink accelerometer internal failure, which affects how the LiveLink telematics unit works until the cause is found.· OtherOtherInfoCauses
- LiveLink accelerometer internal failure or its wiring faulty
- Connector corrosion or a loose pin
Checks
- 1Read the live data for the liveLink accelerometer internal failure and look for a value that is stuck or implausible
- 2Check the liveLink accelerometer internal failure connector and wiring for damage
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB U1907LiveLink telematics modem jammed
LiveLink telematics modem jammed. The controller logged a fault on the liveLink telematics modem jammed, which affects how the LiveLink telematics unit works until the cause is found.· OtherOtherInfoCauses
- LiveLink telematics modem jammed or its wiring faulty
- Connector corrosion or a loose pin
Checks
- 1Read the live data for the liveLink telematics modem jammed and look for a value that is stuck or implausible
- 2Check the liveLink telematics modem jammed connector and wiring for damage
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB U1908LiveLink GPS antenna malfunction
LiveLink GPS antenna malfunction. The controller logged a fault on the liveLink GPS antenna malfunction, which affects how the LiveLink telematics unit works until the cause is found.· OtherOtherInfoCauses
- LiveLink GPS antenna malfunction or its wiring faulty
- Connector corrosion or a loose pin
Checks
- 1Read the live data for the liveLink GPS antenna malfunction and look for a value that is stuck or implausible
- 2Check the liveLink GPS antenna malfunction connector and wiring for damage
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB U1909LiveLink no communication with GPS module
LiveLink no communication with GPS module. The controller did not receive a valid message or lost contact on the bus, so data for the LiveLink telematics unit is missing or unreliable.· Lost messageLost messageInfoCauses
- CAN wiring open, shorted or wet at a connector
- The sending module not powered, reset or faulty
Checks
- 1Check the CAN high and low wiring and the 120 ohm termination
- 2Check that the sending module has power, earth and no active faults of its own
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB U2106CAN timeout fault
A controller timed out waiting for a CAN message, the same condition as U0101 but reported from another module. A module stopped sending in time.· Lost messageLost messageCheck soonCauses
- Controller that sends the message not powered or reset
- CAN wiring or connector fault
Checks
- 1Find out which controller reports the code and which one it expects to hear from
- 2Check that controller's supply, earth and CAN connector
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Shared checks
Checks, in order
- 1Check the CAN high and low wiring for opens, shorts and water
- 2Check the antenna cable and connector (on the LiveLink telematics unit, with the diagnostic tool and a multimeter)
- 3Measure the bus resistance with power off, it should show the termination
- 4Check the SIM card is seated and active (on the LiveLink telematics unit, with the diagnostic tool and a multimeter)
- 5Unplug nodes one at a time to find a faulty one
- 6Check the supply voltage at the LiveLink unit (on the LiveLink telematics unit, with the diagnostic tool and a multimeter)
- 7Run the ECU binding procedure after any ECU change
Causes
- CAN wiring damaged or water in connectors
- Antenna or cable fault
- Missing or wrong termination
- SIM card or network problem
Most common here: lost message (12 of 27)
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
When to stop
You'll notice: Several controllers may report faults at once, some functions may be limited, and the engine may derate.
Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.
