Hyundai · Transmission TCU codes (hex)
Hyundai TCU auxiliary output circuits fault codes
These codes cover TCU outputs other than the clutch valves: engine derating, the customer specific ride control function, the reverse warning relay, the starter interlock relay, the converter lock-up solenoid, the difflock or axle connection and the warning signal output.
Where this code shows
Turn the key on and open the fault code or diagnosis menu on the cluster.
What do these codes mean?
Hyundai codes A1 to 96 are all about the tCU auxiliary output circuits. The most common failure type is shorted high (7 of 21); none needs an immediate stop. Start with this check: check the wire and connector from the TCU to the affected device.
How urgent are they?
None of the 21 codes here means stop now; 21 are information only.
- Info21
What should I check first?
Check the wire and connector from the TCU to the affected device
Shared checks21 of 21
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
Hyundai A1TCU difflock or axle connection: short to ground
The difflock solenoid output looks shorted to ground. A grounded difflock line can leave the lock engaged or disabled, so test it on loose ground. Test the difflock switch on loose ground and watch the lamp. Check the difflock solenoid resistance. Axle housing vibration can wear this wire. Axle breather leaks wet the connector.· Shorted lowShorted lowInfoCauses
- Fault in the wiring or connector of the difflock or axle connection
- Difflock or axle connection coil or relay failed
Checks
- 1Check the cable and connector for the difflock or axle connection
- 2Test the difflock or axle connection coil or relay resistance for the short to ground condition
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Hyundai A2TCU difflock or axle connection: short to battery voltage
The difflock solenoid output looks shorted to battery voltage. A supply short on the difflock output can hold it on in turns, so check the turning feel. Steer tightly with the difflock off and see whether the axle fights the turn. Check the difflock fuse. Aftermarket lighting taps can inject supply. Lighting add-ons commonly splice here.· Shorted highShorted highInfoCauses
- Fault in the wiring or connector of the difflock or axle connection
- Difflock or axle connection coil or relay failed
Checks
- 1Check the cable and connector for the difflock or axle connection
- 2Test the difflock or axle connection coil or relay resistance for the short to battery voltage condition
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Hyundai A3TCU difflock or axle connection: open circuit
The difflock solenoid output looks open. An open difflock line means the axle lock will not engage, so traction on loose ground drops. Switch the difflock on and see whether the axle actually locks. Check the difflock plug. Axle plug seals may leak and corrode. Mud packed around the plug seals causes corrosion.· Open circuitOpen circuitInfoCauses
- Fault in the wiring or connector of the difflock or axle connection
- Difflock or axle connection coil or relay failed
Checks
- 1Check the cable and connector for the difflock or axle connection
- 2Test the difflock or axle connection coil or relay resistance for the open circuit condition
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Hyundai A4TCU warning signal output: short to ground
The warning signal output looks shorted to ground. A grounded warning output may sound or light a warning device constantly. Listen for a warning device that sounds all the time. Check the warning wire for chafing. Dashboard harness folds can wear this wire. Switch panel folds chafe conductors.· Shorted lowShorted lowInfoCauses
- Fault in the wiring or connector of the warning signal output
- Warning signal output coil or relay failed
Checks
- 1Check the cable and connector for the warning signal output
- 2Test the warning signal output coil or relay resistance for the short to ground condition
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Hyundai A5TCU warning signal output: open circuit
The warning signal output looks open. An open warning output means the warning device never gets driven, so protection warnings are lost. Check that the warning device sounds with a bench supply. Check the warning plug. Warning lamp bulb failures can mimic this. Bulb filaments can break and mimic opens.· Open circuitOpen circuitInfoCauses
- Fault in the wiring or connector of the warning signal output
- Warning signal output coil or relay failed
Checks
- 1Check the cable and connector for the warning signal output
- 2Test the warning signal output coil or relay resistance for the open circuit condition
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Hyundai A6TCU warning signal output: short to battery voltage
The warning signal output looks shorted to battery voltage. A supply short on the warning output may hold the device on. Check the warning device with its plug off. Check the warning fuse. Pinched harness near the console can leak supply. Console wiring pinches under trim.· Shorted highShorted highInfoCauses
- Fault in the wiring or connector of the warning signal output
- Warning signal output coil or relay failed
Checks
- 1Check the cable and connector for the warning signal output
- 2Test the warning signal output coil or relay resistance for the short to battery voltage condition
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Hyundai 7DTCU engine derating device: short to ground
Engine derating stays on while the fault is present. This line ties to the engine derating input, so a grounded wire may leave the engine derated and short of power. Measure the derating wire with the plug off and compare it with the working side. Compare it with the working side of the derating circuit. Look for pinched cable beneath the cab floor. Derate may appear as sluggish acceleration only.· Shorted lowShorted lowInfoCauses
- Fault in the wiring or connector of the engine derating device
- Engine derating device coil or relay failed
Checks
- 1Check the cable and connector for the engine derating device
- 2Test the engine derating device coil or relay resistance for the short to ground condition
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Hyundai 7ETCU engine derating device: short to battery voltage
The engine derating output looks shorted to battery voltage. A supply short on this line does not change driving, so the fault may only be found by reading codes. Measure the derating wire with the plug off for contact with supply. It is not a drive-affecting fault. Aftermarket accessories sometimes tap this wire. Harness tie wraps sometimes bite wires.· Shorted highShorted highInfoCauses
- Fault in the wiring or connector of the engine derating device
- Engine derating device coil or relay failed
Checks
- 1Check the cable and connector for the engine derating device
- 2Test the engine derating device coil or relay resistance for the short to battery voltage condition
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Hyundai 7FTCU engine derating device: open circuit
The engine derating output looks open and the TCU keeps running normally. An open derating line means the TCU cannot request derating, so protection against torque overload is reduced. Measure the derating wire for continuity with the plug off. Protection reduces rather than failing outright. A previous engine swap can leave this plug unmated. Inspect splice blocks inside the cab loom.· Open circuitOpen circuitInfoCauses
- Fault in the wiring or connector of the engine derating device
- Engine derating device coil or relay failed
Checks
- 1Check the cable and connector for the engine derating device
- 2Test the engine derating device coil or relay resistance for the open circuit condition
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Hyundai 9ATCU converter lock-up clutch solenoid: short to ground
The lock-up solenoid output looks shorted to ground. A grounded lock-up solenoid line can leave the converter clutch held, so check driveability at low speed for stalling. Drive slowly and watch for drag or stall at low speed. Check the solenoid resistance. Oily harness insulation can swell and chafe. Transmission oil seeping into plugs causes swelling.· Shorted lowShorted lowInfoCauses
- Fault in the wiring or connector of the converter lock-up clutch solenoid
- Converter lock-up clutch solenoid coil or relay failed
Checks
- 1Check the cable and connector for the converter lock-up clutch solenoid
- 2Test the converter lock-up clutch solenoid coil or relay resistance for the short to ground condition
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Hyundai 9BTCU converter lock-up clutch solenoid: open circuit
The converter clutch stays open, which shows as lost lock-up and higher converter slip. An open line leaves lock-up unavailable, so fuel use rises on long drives and converter oil runs hotter. Compare converter oil temperature after a long drive with a similar machine. Check the solenoid plug. Gearbox heat can bake the plug brittle. Heat cycling hardens connector seals.· Open circuitOpen circuitInfoCauses
- Fault in the wiring or connector of the converter lock-up clutch solenoid
- Converter lock-up clutch solenoid coil or relay failed
Checks
- 1Check the cable and connector for the converter lock-up clutch solenoid
- 2Test the converter lock-up clutch solenoid coil or relay resistance for the open circuit condition
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Hyundai 9CTCU converter lock-up clutch solenoid: short to battery voltage
The lock-up solenoid output looks shorted to battery voltage. A supply short on the lock-up output may hold the converter clutch on in the wrong gear. Check lock-up behaviour as the machine accelerates through the gears. Check the solenoid fuse. A burnt harness section near the exhaust can leak supply. Exhaust proximity bakes loom coverings.· Shorted highShorted highInfoCauses
- Fault in the wiring or connector of the converter lock-up clutch solenoid
- Converter lock-up clutch solenoid coil or relay failed
Checks
- 1Check the cable and connector for the converter lock-up clutch solenoid
- 2Test the converter lock-up clutch solenoid coil or relay resistance for the short to battery voltage condition
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Hyundai 17TCU customer function 1 (ride control): short to ground
The ride control output looks shorted to vehicle ground. Ride control is a customer-fitted function, so check whether this machine actually has a ride control kit before chasing wiring. Look for any aftermarket kit connected to the customer output. Check the option wiring diagram. Previously fitted suspension kits sometimes leave stubs. Suspension solenoid coils fail with age.· Shorted lowShorted lowInfoCauses
- Fault in the wiring or connector of the customer function 1 (ride control)
- Customer function 1 (ride control) coil or relay failed
Checks
- 1Check the cable and connector for the customer function 1 (ride control)
- 2Test the customer function 1 (ride control) coil or relay resistance for the short to ground condition
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Hyundai 18TCU customer function 1 (ride control): short to battery voltage
The ride control output looks shorted to battery voltage. Because ride control is customer-fitted, confirm the kit is fitted and that no loose aftermarket wire is touching supply. Look for any aftermarket kit wired into the customer output. Check the option fuse. Tapped power feeds are common on retrofits. Check relay contact welding on option kits.· Shorted highShorted highInfoCauses
- Fault in the wiring or connector of the customer function 1 (ride control)
- Customer function 1 (ride control) coil or relay failed
Checks
- 1Check the cable and connector for the customer function 1 (ride control)
- 2Test the customer function 1 (ride control) coil or relay resistance for the short to battery voltage condition
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Hyundai 19TCU customer function 1 (ride control): open circuit
The ride control output looks open. An open ride control line may simply mean the option is not connected, so confirm what is fitted. Look for a disconnected option plug on the customer output. Check that the option plug is mated. Seasonal attachments may remove the plug. Look for cut wires from earlier repairs.· Open circuitOpen circuitInfoCauses
- Fault in the wiring or connector of the customer function 1 (ride control)
- Customer function 1 (ride control) coil or relay failed
Checks
- 1Check the cable and connector for the customer function 1 (ride control)
- 2Test the customer function 1 (ride control) coil or relay resistance for the open circuit condition
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Hyundai 91TCU reverse warning relay: short to ground
The backup alarm stays on while the fault is present. A grounded wire holds the reverse warning alarm on, which an operator notices first as a constant beeper. Test the alarm by selecting reverse and by listening in neutral. Check the relay coil with a spare. Water ingress at the rear lamp cluster can short this wire. Lamp housings can fill with water.· Shorted lowShorted lowInfoCauses
- Fault in the wiring or connector of the reverse warning relay
- Reverse warning relay coil or relay failed
Checks
- 1Check the cable and connector for the reverse warning relay
- 2Test the reverse warning relay coil or relay resistance for the short to ground condition
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Hyundai 92TCU reverse warning relay: short to battery voltage
The reverse warning relay output looks shorted to battery voltage. A supply short on this output leaves the relay state uncertain, so test the alarm in reverse and neutral. Test the alarm in reverse after clearing the code. Check the alarm fuse. A melted fuse holder can leak supply onto the wire. Fuse boxes can overheat and creep.· Shorted highShorted highInfoCauses
- Fault in the wiring or connector of the reverse warning relay
- Reverse warning relay coil or relay failed
Checks
- 1Check the cable and connector for the reverse warning relay
- 2Test the reverse warning relay coil or relay resistance for the short to battery voltage condition
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Hyundai 93TCU reverse warning relay: open circuit
The reverse warning relay output looks open, so the alarm may not sound. An open relay line means the backup alarm will not sound in reverse, which is a safety matter on site. Test the alarm in reverse and look at the relay base. Check the alarm bulb or horn. Rear harness vibration commonly breaks this wire. Tail harness flexing breaks conductors.· Open circuitOpen circuitInfoCauses
- Fault in the wiring or connector of the reverse warning relay
- Reverse warning relay coil or relay failed
Checks
- 1Check the cable and connector for the reverse warning relay
- 2Test the reverse warning relay coil or relay resistance for the open circuit condition
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Hyundai 94TCU starter interlock relay: short to ground
The starter interlock relay output looks shorted to ground. This relay is part of the starter interlock, so a fault can stop the starter working in the wrong gear or let it crank when it should not. Try to crank in neutral and in gear to see how the interlock behaves. Check the interlock relay with a spare. Corroded ignition switch contacts may mimic this fault. Ignition barrel wear changes contact patterns.· Shorted lowShorted lowInfoCauses
- Fault in the wiring or connector of the starter interlock relay
- Starter interlock relay coil or relay failed
Checks
- 1Check the cable and connector for the starter interlock relay
- 2Test the starter interlock relay coil or relay resistance for the short to ground condition
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Hyundai 95TCU starter interlock relay: short to battery voltage
The starter interlock relay output looks shorted to battery voltage. A supply short on this output may hold the starter interlock open, so check that the engine will not start in gear. Try to crank in gear to confirm the interlock still works. Check the interlock fuse. Wiring modifications near the starter can leak supply. Starter terminals can leak at the solenoid post.· Shorted highShorted highInfoCauses
- Fault in the wiring or connector of the starter interlock relay
- Starter interlock relay coil or relay failed
Checks
- 1Check the cable and connector for the starter interlock relay
- 2Test the starter interlock relay coil or relay resistance for the short to battery voltage condition
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Hyundai 96TCU starter interlock relay: open circuit
The starter interlock relay output looks open. An open interlock relay line can leave the starter disabled, so a no-crank complaint may trace back to it. Try to crank in neutral to see whether the starter responds. Check the interlock relay base. Starter relay socket corrosion is common. Relay sockets crack from vibration.· Open circuitOpen circuitInfoCauses
- Fault in the wiring or connector of the starter interlock relay
- Starter interlock relay coil or relay failed
Checks
- 1Check the cable and connector for the starter interlock relay
- 2Test the starter interlock relay coil or relay resistance for the open circuit condition
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Shared checks
Checks, in order
- 1Check the wire and connector from the TCU to the affected device
- 2Measure the coil or relay resistance and compare it with a known-good one
- 3Look for contact to ground or battery voltage along the wire
- 4Check the fuse for the circuit with the key on
- 5Clear the code and then operate the function to confirm it works
Causes
- Relay or solenoid coil open or shorted
- Wire from the TCU to the device damaged
- Connector corroded
- Wire touching battery voltage or ground
Most common here: shorted high (7 of 21)
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
When to stop
You'll notice: A function such as the backup alarm, ride control, lock-up or starter interlock may stop working or stay on, and the display shows a hex code.
Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.