The charger checks the battery pack and its surroundings before and during a charge. It reports battery voltage that is too high or too low for the profile, a pack that will not accept or hold a charge, an AC supply above 270 VAC or unstable, a battery temperature sensor or cooling fan problem, and a connection problem such as reversed battery leads or an external disable.

FaultCheckE-0-0-1Genie · Charger battery, supply, temperature and connection errors
Code shows hereFAULTE-0-0-1

Where this code shows

Scissors: read the code on the platform LED display or the ground control LCD.

What do these codes mean?

Genie codes E-0-0-1 to E-0-3-8 are all about the charger battery, supply, temperature and connection errors. The most common failure type is real condition (3 of 15); none needs an immediate stop. Start with this check: measure pack voltage at the charger terminals and compare it with the charger rating, then check each battery in the pack.

How urgent are they?

None of the 15 codes here means stop now; all 15 can wait until the shift ends, but find the cause before the next one.

  • Check soon15

What should I check first?

Measure pack voltage at the charger terminals and compare it with the charger rating, then check each battery in the pack.

Shared checks

15 of 15

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Genie E-0-0-1High battery voltage

    The battery voltage is too high for the charger to start a charge.· Shorted high
    Check soon

    Causes

    • Wrong battery type or voltage for the charger profile
    • Overcharged pack after a previous charge
    • Loose or wrong battery cable connections
    • Charger voltage sensing fault

    Checks

    1. 1Measure pack voltage at the charger terminals with a meter and compare it with the charger rating.
    2. 2Check the cable connections and polarity at the batteries and charger.
    3. 3Confirm the battery type matches the charger profile for the machine.
    4. 4Disconnect the pack for 30 seconds and reconnect to clear the code.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Genie E-0-0-2Low battery voltage before charge

    The battery voltage is too low for the charger to start a charge.· Shorted low
    Check soon

    Causes

    • Deeply discharged pack
    • Bad cell or battery connection
    • Loose or corroded battery cables
    • Charger sensing wire fault

    Checks

    1. 1Measure the pack voltage and each battery's voltage; a weak battery will read well below its neighbours.
    2. 2Check the cable connections for looseness and corrosion.
    3. 3Check the battery condition with a load or hydrometer test.
    4. 4Disconnect and reconnect the pack after repair to clear the code.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Genie E-0-0-3Charge timeout

    The battery pack did not reach the target voltage within the safe time, so the charger cut the charge.· Open circuit
    Check soon

    Causes

    • High temperature reducing charger output
    • Worn or damaged battery
    • Loose battery connections

    Checks

    1. 1Charge in cooler conditions and check the charger and batteries are not hot.
    2. 2Test each battery's voltage and condition; replace any weak battery.
    3. 3Check the battery cable connections for looseness and corrosion.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Genie E-0-0-4Defective battery

    The charger could not trickle-charge the battery pack up to the minimum voltage, so the pack is judged defective.· Other
    Check soon

    Causes

    • Failed or damaged battery
    • Loose or corroded connections
    • Shorted cell in the pack
    • Deeply discharged pack that cannot recover

    Checks

    1. 1Check the voltage of each battery to find a dead or shorted cell.
    2. 2Check the connections at each battery terminal and the main cables.
    3. 3Check water level and condition on flooded batteries.
    4. 4Disconnect the battery for 30 seconds to clear the code after repair.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Genie E-0-0-7Amp hour limit exceeded

    The safety amp-hour limit was exceeded during the charge, so the charger stopped.· Open circuit
    Check soon

    Causes

    • Weak or damaged battery that cannot hold charge
    • Deeply discharged pack
    • Parasitic load running while charging

    Checks

    1. 1Test each battery's voltage and capacity with a load test.
    2. 2Disconnect parasitic loads, such as an accessory drawing power, while charging.
    3. 3Check the battery connections for looseness and corrosion.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Genie E-0-0-8Battery temperature out of range

    The battery temperature sensor reports a temperature outside the range allowed for charging (Genie fault ID 233, type 19).· Other
    Check soon

    Causes

    • Battery temperature sensor wiring fault
    • Hot or cold batteries
    • Failed temperature sensor

    Checks

    1. 1Check the temperature sensor and its connections.
    2. 2Rest the charger and disconnect AC power for 30 seconds.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Genie E-0-1-1Disabled by external command

    The charger received a command to stop charging from outside, for example from the machine, and did not charge the battery pack (Genie fault ID 135, type 8).· Other
    Check soon

    Causes

    • External disable signal active
    • Interlock input held

    Checks

    1. 1Check the machine's charger interlock input.
    2. 2Clear the external command and retry; the code self clears.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Genie E-0-1-2Reverse polarity

    The battery pack is connected the wrong way round to the charger (Genie fault ID 135, type 8), so charging is blocked.· Real condition
    Check soon

    Causes

    • Battery cables reversed after service
    • Charger leads reversed

    Checks

    1. 1Check the battery cable polarity at the pack and the charger.
    2. 2Correct the connection; the code self clears.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Genie E-0-1-3Battery does not take current

    The charger detects battery voltage but cannot push charging current into the pack (Genie fault ID 204, type 21).· Other
    Check soon

    Causes

    • Open battery connection
    • Worn batteries that will not accept current

    Checks

    1. 1Check battery connections.
    2. 2Self clearing when the condition is corrected.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Genie E-0-2-1High battery voltage while charging

    The battery voltage went too high while charging, as seen by the charger profile (Genie fault ID 254, type 23).· Real condition
    Check soon

    Causes

    • Wrong charger profile for the battery type
    • Loose cable giving wrong voltage readings

    Checks

    1. 1Check battery voltage and cable connections.
    2. 2Confirm the profile matches the battery type.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Genie E-0-2-2Low battery voltage while charging

    The battery voltage was too low while charging, as seen by the charger profile (Genie fault ID 254, type 24).· Real condition
    Check soon

    Causes

    • Wrong charger profile for the battery type
    • Weak or failing battery

    Checks

    1. 1Check battery voltage and cable connections.
    2. 2Confirm the profile matches the battery type.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Genie E-0-2-3High AC voltage

    The AC supply to the charger is higher than 270 VAC (Genie fault ID 267, type 23).· Other
    Check soon

    Causes

    • AC supply over 270 VAC
    • Faulty generator or supply

    Checks

    1. 1Connect to a stable AC source between 85 and 270 VAC at 45 to 65 Hz.
    2. 2Self clearing when the condition is corrected.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Genie E-0-2-5Low AC voltage oscillation

    The AC voltage supplied to the charger is unstable and low (Genie fault ID 267, type 24).· Other
    Check soon

    Causes

    • Undersized generator
    • Weak or unstable AC source

    Checks

    1. 1Connect to a stable AC source between 85 and 270 VAC at 45 to 65 Hz.
    2. 2Check the generator size if one is used.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Genie E-0-3-6Battery temperature sensor required by profile

    The selected charge profile needs a battery temperature sensor, but none is installed (Genie fault ID 233, type 21).· Other
    Check soon

    Causes

    • Sensor not fitted
    • Sensor wiring open
    • Wrong profile for the machine

    Checks

    1. 1Check the battery temperature sensor connections.
    2. 2Check the charger profile and confirm a sensor is installed.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Genie E-0-3-8Stalled cooling fan

    The charger cooling fan is stalled or obstructed (Genie fault ID 268, type 21).· Other
    Check soon

    Causes

    • Fan blocked by debris
    • Fan motor failed

    Checks

    1. 1Inspect the fan for damage.
    2. 2Clear any blockage.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

Shared checks

Checks, in order

  1. 1Measure pack voltage at the charger terminals and compare it with the charger rating, then check each battery in the pack.
  2. 2Check the battery cables, terminals and polarity at the pack and the charger for loose or corroded joints.
  3. 3Confirm the charger profile matches the battery type fitted to the machine.
  4. 4Measure the AC supply at the plug and use a short, adequate lead; high or unstable mains stops the charge.
  5. 5Disconnect the pack for 30 seconds to clear the code after the repair.

Causes

  • Wrong battery type or voltage for the charger profile
  • Worn, sulphated or deeply discharged battery pack
  • Loose or corroded battery cables, or leads connected the wrong way round
  • AC supply out of range or extension lead too long

Most common here: real condition (3 of 15)

Check the real value with a separate gauge or thermometer before blaming the sensor.

When to stop

You'll notice: Charging does not start or stops and the charger flashes amber.

Let the engine cool before opening the cooling system; a hot cap releases scalding coolant. Running on with an overheat warning risks a head gasket or seized engine.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.