Genie · Battery charger codes
Genie Fault Code E‑0‑0‑4
Charger: defective battery
What does Genie code E-0-0-4 mean?
The charger could not trickle-charge the battery pack up to the minimum voltage, so the pack is judged defective. The charger stops until the pack is repaired. Urgency: check soon - the machine may derate or limit a function. Check first: check the voltage of each battery to find a dead or shorted cell.
Can I keep running with it?
Check soon
The machine may derate or limit a function. Find the cause before the next shift.
What should I check first?
Check the voltage of each battery to find a dead or shorted cell.
Then 3 more checksWhere this code shows
Scissors: read the code on the platform LED display or the ground control LCD.
Checks
0 of 4 done
Causes
- Failed or damaged battery
- Loose or corroded connections
- Shorted cell in the pack
- Deeply discharged pack that cannot recover
How it failed
You'll notice: The charger refuses to charge because it could not trickle the pack up to minimum voltage, so the pack is judged defective.
OtherRead from how the source describes the code
The source does not say how this one failed.
- Meter test
- Read the code with the service tool and note which other codes are active with it.
- Good result
- Codes that appear together usually share one cause - start with the wiring they share.
When to stop
Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.
Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Same part, other failures: Charger battery, supply, temperature and connection errors
- E-0-0-1Charger: high battery voltageShorted highCheck soon
- E-0-0-2Charger: low battery voltage before chargeShorted lowCheck soon
- E-0-0-3Charger: charge timeoutOpen circuitCheck soon
- E-0-0-4Charger: defective batteryOtherCheck soon
- E-0-0-7Charger: amp hour limit exceededOpen circuitCheck soon
- E-0-0-8Charger: battery temperature out of rangeOtherCheck soon
- E-0-1-1Charger: disabled by external commandOtherCheck soon
- E-0-1-2Charger: reverse polarityReal conditionCheck soon
- E-0-1-3Charger: battery does not take currentOtherCheck soon
Show the other 6 codesHide the other codes
- E-0-2-1Charger: high battery voltage while chargingReal conditionCheck soon
- E-0-2-2Charger: low battery voltage while chargingReal conditionCheck soon
- E-0-2-3Charger: high AC voltageOtherCheck soon
- E-0-2-5Charger: low AC voltage oscillationOtherCheck soon
- E-0-3-6Charger: battery temperature sensor required by profileOtherCheck soon
- E-0-3-8Charger: stalled cooling fanOtherCheck soon
Other Genie codes: Battery charger codes
Related on Equipments Finder
Source
This source lists E-0-0-4 and its meaning. The guidance on this page is general, not taken from it.
The source covers: Genie GS slab scissors with the on-board charger.
Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.