Genie · Battery charger codes
Genie Fault Code E‑0‑0‑1
Charger: high battery voltage
What does Genie code E-0-0-1 mean?
The battery voltage is too high for the charger to start a charge. The charger waits and the code clears itself once the pack voltage is within range. Urgency: check soon - the machine may derate or limit a function. Check first: measure pack voltage at the charger terminals with a meter and compare it with the charger rating.
Can I keep running with it?
Check soon
The machine may derate or limit a function. Find the cause before the next shift.
What should I check first?
Measure pack voltage at the charger terminals with a meter and compare it with the charger rating.
Then 3 more checksWhere this code shows
Scissors: read the code on the platform LED display or the ground control LCD.
Checks
0 of 4 done
Causes
- Wrong battery type or voltage for the charger profile
- Overcharged pack after a previous charge
- Loose or wrong battery cable connections
- Charger voltage sensing fault
How it failed
You'll notice: The charger will not start charging and flashes amber while the pack voltage is too high; it restarts by itself once voltage falls.
Shorted highRead from how the source describes the code
The signal sits at or near the supply voltage - more than a working sensor can send.
- Meter test
- Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
- Good result
- Open circuit (OL) between them. Any low reading is the short.
When to stop
Most sensor and wiring faults can be traced with a multimeter and the wiring diagram. Disconnect the battery before unplugging controllers; if the controller itself is suspect or needs programming, that needs the dealer’s service tool.
Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Same part, other failures: Charger battery, supply, temperature and connection errors
- E-0-0-1Charger: high battery voltageShorted highCheck soon
- E-0-0-2Charger: low battery voltage before chargeShorted lowCheck soon
- E-0-0-3Charger: charge timeoutOpen circuitCheck soon
- E-0-0-4Charger: defective batteryOtherCheck soon
- E-0-0-7Charger: amp hour limit exceededOpen circuitCheck soon
- E-0-0-8Charger: battery temperature out of rangeOtherCheck soon
- E-0-1-1Charger: disabled by external commandOtherCheck soon
- E-0-1-2Charger: reverse polarityReal conditionCheck soon
- E-0-1-3Charger: battery does not take currentOtherCheck soon
Show the other 6 codesHide the other codes
- E-0-2-1Charger: high battery voltage while chargingReal conditionCheck soon
- E-0-2-2Charger: low battery voltage while chargingReal conditionCheck soon
- E-0-2-3Charger: high AC voltageOtherCheck soon
- E-0-2-5Charger: low AC voltage oscillationOtherCheck soon
- E-0-3-6Charger: battery temperature sensor required by profileOtherCheck soon
- E-0-3-8Charger: stalled cooling fanOtherCheck soon
Other Genie codes: Battery charger codes
Related on Equipments Finder
Source
This source lists E-0-0-1 and its meaning. The guidance on this page is general, not taken from it.
The source covers: Genie GS slab scissors with the on-board charger.
Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.