Deutz · Exhaust aftertreatment (SCR)
Deutz Fault Code SPN 523633 FMI 11
Exhaust aftertreatment - Efficiency SCR system - Root cause not known
What does Deutz code SPN 523633 FMI 11 mean?
The EMR4 reports the SCR efficiency fault with unknown root cause. The conversion of NOx is below the required level and the controller cannot say why. Urgency: check soon - the machine may derate or limit a function. Check first: check the DEF level and quality with a refractometer, since weak DEF is the most common cause of poor SCR efficiency.
- SPN 523633
- What is at fault
- FMI 11
- Root cause not known
Can I keep running with it?
Check soon
The machine may derate or limit a function. Find the cause before the next shift.
What should I check first?
Check the DEF level and quality with a refractometer, since weak DEF is the most common cause of poor SCR efficiency
Then 4 more checksWhere to read it
Read the active and stored faults with Deutz SerDia (or the machine maker's diagnostic tool) on the engine diagnostic plug.
Checks
0 of 5 done
Causes
- Poor DEF quality or empty tank
- Dosing valve partly blocked
- Catalyst aged or contaminated
- NOx sensor reading wrong
How it failed
You'll notice: An emission lamp and a power derate countdown follow if not fixed.
OtherRead from FMI 11: root cause not known
The source does not say how this one failed.
- Meter test
- Read the code with the service tool and note which other codes are active with it.
- Good result
- Codes that appear together usually share one cause - start with the wiring they share.
When to stop
Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.
Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Same part, other failures: SCR system output, catalyst temperature and pressure sensors
- SPN 4360 FMI 2Exhaust aftertreatment - Temperature before SCR Cat - Data erratic intermittent or incorrectErratic or implausibleCheck soon
- SPN 4361 FMI 2Exhaust aftertreatment - Dynamic temperature check before SCR - Data erratic intermittent or incorrectErratic or implausibleCheck soon
- SPN 4361 FMI 3Exhaust aftertreatment - Temperature SCR Cat - Voltage above normal or shorted to high sourceShorted highCheck soon
- SPN 4361 FMI 4Exhaust aftertreatment - Temperature SCR Cat - Voltage below normal or shorted to low sourceShorted lowCheck soon
- SPN 523633 FMI 11Exhaust aftertreatment - Efficiency SCR system - Root cause not knownOtherCheck soon
- SPN 523718 FMI 3Exhaust aftertreatment - SCR system - Voltage above normal or shorted to high sourceShorted highCheck soon
- SPN 523718 FMI 4Exhaust aftertreatment - SCR system - Voltage below normal or shorted to low sourceShorted lowCheck soon
- SPN 523718 FMI 5Exhaust aftertreatment - SCR system - Current below normal or open circuitOpen circuitCheck soon
- SPN 523718 FMI 12Exhaust aftertreatment - SCR system - Bad intelligent device or componentPart or controllerCheck soon
Show the other 10 codesHide the other codes
- SPN 3241 FMI 0Exhaust aftertreatment - Temperature before SCR Cat - Data above normal operational range (Most severe level)Real conditionCheck soon
- SPN 4360 FMI 0Exhaust aftertreatment - Temperature before SCR Cat - Data above normal operational range (Most severe level)Real conditionCheck soon
- SPN 4360 FMI 1Exhaust aftertreatment - Temperature before SCR Cat - Data below normal operational range (Most severe level)Real conditionCheck soon
- SPN 524065 FMI 0Exhaust aftertreatment - Pressure sensor before SCR Cat - Data above normal operational range (Most severe level)Real conditionCheck soon
- SPN 524065 FMI 1Exhaust aftertreatment - Pressure sensor before SCR Cat - Data below normal operational range (Most severe level)Real conditionCheck soon
- SPN 524065 FMI 2Exhaust aftertreatment - Pressure sensor before SCR Cat - Data erratic intermittent or incorrectErratic or implausibleCheck soon
- SPN 524065 FMI 3Exhaust aftertreatment - Pressure sensor before SCR Cat - Voltage above normal or shorted to high sourceShorted highCheck soon
- SPN 524065 FMI 4Exhaust aftertreatment - Pressure sensor before SCR Cat - Voltage below normal or shorted to low sourceShorted lowCheck soon
- SPN 524096 FMI 14Exhaust aftertreatment - EPA counter - Special instructionsOtherInformation
- SPN 524175 FMI 0Exhaust aftertreatment - NOx emission downstream SCR Cat - Data above normal operational range (Most severe level)Real conditionCheck soon
Other Deutz codes: Exhaust aftertreatment (SCR)
- SPN 3361 FMI 7Exhaust aftertreatment - DEF metering unit - Mechanical system not responding or out of adjustment
- SPN 523668 FMI 11Exhaust aftertreatment - Hardware failure temperature sensor DEF suction unit - Root cause not known
- SPN 523669 FMI 11Exhaust aftertreatment - Hardware failure quality sensor DEF suction unit - Root cause not known
- SPN 523670 FMI 11Exhaust aftertreatment - Hardware failure level sensor DEF suction unit - Root cause not known
Related on Equipments Finder
Source
DEUTZ KWP-Codes EMR4 (KWPList EMR4 DE EN, Revision 2.0), page 16
This source lists SPN 523633 FMI 11 and its meaning. The guidance on this page is general, not taken from it.
The source covers: Deutz engines with the EMR4 controller (the Deutz list applies to all EMR4 engine series, e.g. TCD 2.9, 3.6, 4.1, 6.1, 7.8 as fitted in machines).
Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.