Deutz · Relays and outputs
Deutz Actuator relays, starter circuit and glow plug control fault codes
The outputs that switch machine loads for the EMR4: the actuator relays 2 to 7 whose use depends on the machine maker, the starter relay and starter switch circuit (SPN 677), and the glow plug control for preheat (SPN 729). Each code names the output and whether it is shorted to supply, shorted to ground, open or faulty.
Where to read it
Read the active and stored faults with Deutz SerDia (or the machine maker's diagnostic tool) on the engine diagnostic plug.
What do these codes mean?
Deutz codes SPN 676 FMI 11 to SPN 523987 FMI 4 are all about the actuator relays, starter circuit and glow plug control. The most common failure type is shorted low (9 of 25); none needs an immediate stop. Start with this check: identify what the relay switches on your machine from the wiring diagram.
How urgent are they?
None of the 25 codes here means stop now; all 25 can wait until the shift ends, but find the cause before the next one.
- Check soon25
What should I check first?
Identify what the relay switches on your machine from the wiring diagram
Shared checks25 of 25
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
Glow plug relay1 code
Deutz SPN 676 FMI 11Glow plug relay: Root cause not known
The EMR4 logged a fault on the glow plug relay (in the preheat circuit (glow plug or grid heater) controlled by the EMR4) but could not classify the cause. Test the circuit and the part separately. Deutz list: KWP codes 543 and 544, blink code 263. For this code the controller flagged the glow plug relay but could not tell whether wiring, part or supply is to blame. The glow plug control unit is a separate module with its own diagnostic line to the EMR4. The usual symptom is a lamp with little else to notice, because the controller could not name the cause.· OtherOtherCheck soonCauses
- Intermittent wiring fault
- Failing glow plug relay
- Intermittent contact that left no clear electrical signature
Checks
- 1Read the full SerDia fault list; this code often sits next to a clearer one on the glow plug relay
- 2Measure the supply and ground at the glow plug relay plug with the key on to confirm it is powered
- 3Inspect the glow plug relay plug and harness for chafed insulation, bent pins and moisture
- 4Read the freeze frame stored with the glow plug relay fault and note speed, load and battery voltage at the moment it was logged.
- 5Check the supply fuse and the heavy cable of the glow plug control unit.
- 6Feel or listen for the glow plug relay at key-on, and check its coil feed and ground.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Starter relay4 codes
Deutz SPN 677 FMI 3Starter relay: Voltage high / shorted high
The EMR4 sees the output for the starter relay (on the starter circuit controlled by the EMR4 start output) at a voltage above normal, as if the circuit is shorted to the battery supply. The controller cannot drive the relay or output correctly. Deutz list: KWP code 956, blink code 512. For this code the controller read the starter relay circuit at a voltage above normal, as if the wire or the driver were pulled up to the supply voltage, for instance by a chafed harness touching a live wire. The starter relay circuit also reads the starter switch, so an operator who holds the key too long can log it. The usual symptom is a load that stays energised or never switches off, and the lamp comes on at the next key cycle.· Shorted highShorted highCheck soonCauses
- Starter relay shorted internally
- Output wire shorted to battery positive
- Connector pin touching a live pin
- Relay coil connector corroded
- Harness insulation worn through where it rubs on a bracket, letting the wire touch a live supply
Checks
- 1Check the starter solenoid feed and the heavy cable terminals for tightness and corrosion
- 2Unplug the starter relay: if the code stays, the short is in the harness or the EMR4; if it clears, the part is the shorted one
- 3With the EMR4 unplugged, measure the output wire to battery positive; it should be open
- 4With the EMR4 and the starter relay unplugged, measure the signal wire against battery positive; it must read open, and any reading means the harness is shorted high.
- 5Check the key switch contacts and the starter solenoid wiring.
- 6Crank once and watch the starter relay state and the battery voltage in SerDia together, since a heavy starter load can pull the supply down.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:Engine - Starter relay - Voltage above normal or shorted to high source
Full page for SPN 677 FMI 3Deutz SPN 677 FMI 4Starter relay: Voltage low / shorted low
The EMR4 sees the output for the starter relay (on the starter circuit controlled by the EMR4 start output) at a voltage below normal, as if the circuit is shorted to ground. The controller cannot drive the relay or output correctly. Deutz list: KWP code 957, blink code 512. For this code the controller read the starter relay circuit at a voltage below normal, as if it were tied to ground, which points to a wire rubbing through on the frame or a part shorted to its housing. The starter relay circuit also reads the starter switch, so an operator who holds the key too long can log it. The usual symptom is a load that never switches on, a dead function and a lamp after a few seconds.· Shorted lowShorted lowCheck soonCauses
- Output wire chafed to ground or the engine block
- Water in the connector bridging the pins
- Starter relay winding shorted to its housing
- Wire pinched against the engine block or frame so the signal is pulled to ground
Checks
- 1With the EMR4 unplugged, measure the output wire to ground; it should not be low ohms
- 2Check the starter solenoid feed and the heavy cable terminals for tightness and corrosion
- 3Unplug the starter relay: if the code changes, the part is the shorted one; if it stays, look at the harness
- 4Measure the winding resistance of the part and look for a very low value
- 5With the connector unplugged, measure the starter relay signal wire against ground; a low resistance means a harness short, while an open reading sends you to the part itself.
- 6Crank once and watch the starter relay state and the battery voltage in SerDia together, since a heavy starter load can pull the supply down.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Engine - Starter relay - Voltage below normal or shorted to low source
Deutz SPN 677 FMI 5Starter relay: Current low / open circuit
The EMR4 sees too little current through the starter relay (on the starter circuit controlled by the EMR4 start output), which means the circuit is open. The controller commands the relay or output but nothing flows. Deutz list: KWP code 958, blink code 512. For this code the controller measured too little current in the starter relay circuit, the signature of an open wire, a pulled-out pin or a burnt-out coil. The starter relay circuit also reads the starter switch, so an operator who holds the key too long can log it. The usual symptom is a load that does not respond at all although the controller commands it.· Open circuitOpen circuitCheck soonCauses
- Broken wire or a pin pushed out of the connector
- Relay coil connector corroded
- Connector left unplugged after earlier work
- Terminal pushed back or corroded in its connector so the circuit is open
Checks
- 1Measure the resistance across the starter relay terminals: infinity means an open winding
- 2Listen for the starter relay clicking when you turn the key to start
- 3Inspect both ends of the starter relay circuit (EMR4 plug and part connector) for pins pushed back in the housing
- 4Continuity-test each wire to the matching EMR4 pin
- 5Check the continuity of both wires between the EMR4 plug and the starter relay connector, then the coil resistance, to separate a broken wire from a dead coil.
- 6Crank once and watch the starter relay state and the battery voltage in SerDia together, since a heavy starter load can pull the supply down.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Source wording:Engine - Starter relay - Current below normal or open circuit
Deutz SPN 677 FMI 12Starter relay: Bad device or component
The EMR4 judges the starter relay (on the starter circuit controlled by the EMR4 start output) to be a bad device, meaning the part or its driver electronics no longer respond as a working component. Deutz list: KWP code 959, blink code 512. For this code the starter relay reports an internal fault to the controller, so the electronics inside the part have judged themselves defective. The starter relay circuit also reads the starter switch, so an operator who holds the key too long can log it. The usual symptom is a function that stops at once and will not come back until the part is replaced.· Part or controllerPart or controllerCheck soonCauses
- Water or soot inside the part
- Relay coil connector corroded
- Internal failure of the starter relay
- Driver stage in the EMR4 failing
- Electronics inside the part damaged by heat, water or a voltage spike
Checks
- 1Measure supply voltage and ground at the starter relay connector with the key on to confirm the part is powered
- 2Read the starter relay status in SerDia and run any actuator test
- 3Check the starter solenoid feed and the heavy cable terminals for tightness and corrosion
- 4Listen for the starter relay clicking when you turn the key to start
- 5Check supply voltage and ground at the starter relay connector under load; if both are good the part itself is the likely culprit and a swap with a known good one confirms it.
- 6Crank once and watch the starter relay state and the battery voltage in SerDia together, since a heavy starter load can pull the supply down.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Source wording:Engine - Starter relay - Bad intelligent device or component
Preheating relay4 codes
Deutz SPN 729 FMI 3Preheating relay: Voltage high / shorted high
The EMR4 sees the output for the preheating relay (in the preheat circuit (glow plug or grid heater) controlled by the EMR4) at a voltage above normal, as if the circuit is shorted to the battery supply. The controller cannot drive the relay or output correctly. Deutz list: KWP code 549, blink code 263. For this code the controller read the preheating relay circuit at a voltage above normal, as if the wire or the driver were pulled up to the supply voltage, for instance by a chafed harness touching a live wire. The preheating relay switches the high current to the glow plugs, so it works hard at every cold start. The usual symptom is a load that stays energised or never switches off, and the lamp comes on at the next key cycle.· Shorted highShorted highCheck soonCauses
- Output wire shorted to battery positive
- Preheating relay shorted internally
- Relay coil connector corroded
- Harness insulation worn through where it rubs on a bracket, letting the wire touch a live supply
Checks
- 1With the EMR4 unplugged, measure the output wire to battery positive; it should be open
- 2Unplug the preheating relay: if the code stays, the short is in the harness or the EMR4; if it clears, the part is the shorted one
- 3Measure the winding or coil resistance of the part
- 4With the EMR4 and the preheating relay unplugged, measure the signal wire against battery positive; it must read open, and any reading means the harness is shorted high.
- 5Listen for the relay clicking on key-on in cold weather and measure the voltage drop across its contacts.
- 6Compare the glow plug current draw at key-on with a cold engine; a relay that sticks gives a long burn and a hot connector.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:Engine - Preheating relay - Voltage above normal or shorted to high source
Full page for SPN 729 FMI 3Deutz SPN 729 FMI 4Preheating relay: Voltage low / shorted low
The EMR4 sees the output for the preheating relay (in the preheat circuit (glow plug or grid heater) controlled by the EMR4) at a voltage below normal, as if the circuit is shorted to ground. The controller cannot drive the relay or output correctly. Deutz list: KWP code 551, blink code 263. For this code the controller read the preheating relay circuit at a voltage below normal, as if it were tied to ground, which points to a wire rubbing through on the frame or a part shorted to its housing. The preheating relay switches the high current to the glow plugs, so it works hard at every cold start. The usual symptom is a load that never switches on, a dead function and a lamp after a few seconds.· Shorted lowShorted lowCheck soonCauses
- Preheating relay winding shorted to its housing
- Relay coil connector corroded
- Output wire chafed to ground or the engine block
- Wire pinched against the engine block or frame so the signal is pulled to ground
Checks
- 1Listen for the relay clicking when preheat is requested and measure the output on the heater side
- 2Check the preheat circuit fuse and the heavy cable to the heaters for corrosion
- 3Unplug the preheating relay: if the code changes, the part is the shorted one; if it stays, look at the harness
- 4With the connector unplugged, measure the preheating relay signal wire against ground; a low resistance means a harness short, while an open reading sends you to the part itself.
- 5Listen for the relay clicking on key-on in cold weather and measure the voltage drop across its contacts.
- 6Compare the glow plug current draw at key-on with a cold engine; a relay that sticks gives a long burn and a hot connector.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Engine - Preheating relay - Voltage below normal or shorted to low source
Deutz SPN 729 FMI 5Preheating relay: Current low / open circuit
The EMR4 sees too little current through the preheating relay (in the preheat circuit (glow plug or grid heater) controlled by the EMR4), which means the circuit is open. The controller commands the relay or output but nothing flows. Deutz list: KWP code 545, blink code 263. For this code the controller measured too little current in the preheating relay circuit, the signature of an open wire, a pulled-out pin or a burnt-out coil. The preheating relay switches the high current to the glow plugs, so it works hard at every cold start. The usual symptom is a load that does not respond at all although the controller commands it.· Open circuitOpen circuitCheck soonCauses
- Connector left unplugged after earlier work
- Preheating relay winding open
- Broken wire or a pin pushed out of the connector
- Terminal pushed back or corroded in its connector so the circuit is open
Checks
- 1Continuity-test each wire to the matching EMR4 pin
- 2Check the preheat circuit fuse and the heavy cable to the heaters for corrosion
- 3Inspect both ends of the preheating relay circuit (EMR4 plug and part connector) for pins pushed back in the housing
- 4Listen for the relay clicking when preheat is requested and measure the output on the heater side
- 5Check the continuity of both wires between the EMR4 plug and the preheating relay connector, then the coil resistance, to separate a broken wire from a dead coil.
- 6Compare the glow plug current draw at key-on with a cold engine; a relay that sticks gives a long burn and a hot connector.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Source wording:Engine - Preheating relay - Current below normal or open circuit
Deutz SPN 729 FMI 12Preheating relay: Bad device or component
The EMR4 judges the preheating relay (in the preheat circuit (glow plug or grid heater) controlled by the EMR4) to be a bad device, meaning the part or its driver electronics no longer respond as a working component. Deutz list: KWP code 547, blink code 263. For this code the preheating relay reports an internal fault to the controller, so the electronics inside the part have judged themselves defective. The preheating relay switches the high current to the glow plugs, so it works hard at every cold start. The usual symptom is a function that stops at once and will not come back until the part is replaced.· Part or controllerPart or controllerCheck soonCauses
- Relay coil connector corroded
- Driver stage in the EMR4 failing
- Internal failure of the preheating relay
- Electronics inside the part damaged by heat, water or a voltage spike
Checks
- 1Measure supply voltage and ground at the preheating relay connector with the key on to confirm the part is powered
- 2Check the preheat circuit fuse and the heavy cable to the heaters for corrosion
- 3Fit a known good preheating relay if you can borrow one and see whether the code clears for good
- 4Read the preheating relay status in SerDia and run any actuator test
- 5Check supply voltage and ground at the preheating relay connector under load; if both are good the part itself is the likely culprit and a swap with a known good one confirms it.
- 6Compare the glow plug current draw at key-on with a cold engine; a relay that sticks gives a long burn and a hot connector.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Source wording:Engine - Preheating relay - Bad intelligent device or component
Starter switch to long active1 code
Deutz SPN 523550 FMI 12Starter switch to long active: Bad device or component
The EMR4 judges the starter switch signal active for too long. The start input stays on, so the controller treats it as stuck. Deutz list: KWP code 980, blink code 515. For this code the starter switch to long active reports an internal fault to the controller, so the electronics inside the part have judged themselves defective. The starter relay circuit also reads the starter switch, so an operator who holds the key too long can log it. The usual symptom is a function that stops at once and will not come back until the part is replaced.· Part or controllerPart or controllerCheck soonCauses
- Key switch contacts stuck closed
- Start wire shorted to supply
- Machine start relay stuck
- Electronics inside the part damaged by heat, water or a voltage spike
Checks
- 1Measure the start signal at the EMR4 pin with the key at run; it should be off
- 2Check the machine start relay for a stuck contact
- 3Look at the start wire for a short to supply that keeps the signal active
- 4Check supply voltage and ground at the starter switch to long active connector under load; if both are good the part itself is the likely culprit and a swap with a known good one confirms it.
- 5Check the key switch contacts and the starter solenoid wiring.
- 6Release the key promptly and watch whether the starter switch input returns to off; a switch stuck on logs this code.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Source wording:Engine - Starter switch to long active - Bad intelligent device or component
Diagnostic cable glow plug control2 codes
Deutz SPN 523913 FMI 3Diagnostic cable glow plug control: Voltage high / shorted high
The EMR4 sees the output for the diagnostic cable for glow plug control (between the EMR4 and the glow plug control unit) at a voltage above normal, as if the circuit is shorted to the battery supply. The controller cannot drive the actuator correctly. Deutz list: KWP code 74, blink code 721. For this code the controller read the diagnostic cable glow plug control circuit at a voltage above normal, as if the wire or the driver were pulled up to the supply voltage, for instance by a chafed harness touching a live wire. The diagnostic cable carries status between the glow plug control unit and the EMR4. The usual symptom is a load that stays energised or never switches off, and the lamp comes on at the next key cycle.· Shorted highShorted highCheck soonCauses
- Output wire shorted to battery positive
- Connector pin touching a live pin
- Diagnostic cable for glow plug control shorted internally
- Harness insulation worn through where it rubs on a bracket, letting the wire touch a live supply
Checks
- 1Unplug the diagnostic cable for glow plug control: if the code stays, the short is in the harness or the EMR4; if it clears, the part is the shorted one
- 2With the EMR4 unplugged, measure the output wire to battery positive; it should be open
- 3Measure the winding or coil resistance of the part
- 4With the EMR4 and the diagnostic cable glow plug control unplugged, measure the signal wire against battery positive; it must read open, and any reading means the harness is shorted high.
- 5Check the diagnostic wire between the control unit and the EMR4 for chafing.
- 6Read the glow plug control unit status and its water pump output in SerDia while the key is on.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:Engine - Diagnostic cable glow plug control - Voltage above normal or shorted to high source
Deutz SPN 523913 FMI 4Diagnostic cable glow plug control: Voltage low / shorted low
The EMR4 sees the output for the diagnostic cable for glow plug control (between the EMR4 and the glow plug control unit) at a voltage below normal, as if the circuit is shorted to ground. The controller cannot drive the actuator correctly. Deutz list: KWP code 75, blink code 721. For this code the controller read the diagnostic cable glow plug control circuit at a voltage below normal, as if it were tied to ground, which points to a wire rubbing through on the frame or a part shorted to its housing. The diagnostic cable carries status between the glow plug control unit and the EMR4. The usual symptom is a load that never switches on, a dead function and a lamp after a few seconds.· Shorted lowShorted lowCheck soonCauses
- Output wire chafed to ground or the engine block
- Diagnostic cable for glow plug control winding shorted to its housing
- Water in the connector bridging the pins
- Wire pinched against the engine block or frame so the signal is pulled to ground
Checks
- 1Unplug the diagnostic cable for glow plug control: if the code changes, the part is the shorted one; if it stays, look at the harness
- 2With the EMR4 unplugged, measure the output wire to ground; it should not be low ohms
- 3Measure the winding resistance of the part and look for a very low value
- 4With the connector unplugged, measure the diagnostic cable glow plug control signal wire against ground; a low resistance means a harness short, while an open reading sends you to the part itself.
- 5Check the diagnostic wire between the control unit and the EMR4 for chafing.
- 6Read the glow plug control unit status and its water pump output in SerDia while the key is on.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Engine - Diagnostic cable glow plug control - Voltage below normal or shorted to low source
Glow plug control / Electrical water pump4 codes
Deutz SPN 523914 FMI 3Glow plug control / Electrical water pump: Voltage high / shorted high
The EMR4 sees the output for the glow plug control / electrical water pump driver (on the glow plug control unit) at a voltage above normal, as if the circuit is shorted to the battery supply. The controller cannot drive the actuator correctly. Deutz list: KWP code 78, blink code 721. For this code the controller read the glow plug control / Electrical water pump circuit at a voltage above normal, as if the wire or the driver were pulled up to the supply voltage, for instance by a chafed harness touching a live wire. The glow plug control unit is a separate module with its own diagnostic line to the EMR4. The usual symptom is a load that stays energised or never switches off, and the lamp comes on at the next key cycle.· Shorted highShorted highCheck soonCauses
- Control unit connector wet
- Connector pin touching a live pin
- Output wire shorted to battery positive
- Glow plug control / electrical water pump driver shorted internally
- Harness insulation worn through where it rubs on a bracket, letting the wire touch a live supply
Checks
- 1Unplug the glow plug control / electrical water pump driver: if the code stays, the short is in the harness or the EMR4; if it clears, the part is the shorted one
- 2Check the glow plug control unit supply and ground voltage at key-on
- 3Measure the winding or coil resistance of the part
- 4Test each glow plug for resistance and continuity
- 5With the EMR4 and the glow plug control / Electrical water pump unplugged, measure the signal wire against battery positive; it must read open, and any reading means the harness is shorted high.
- 6Read the glow plug control unit status and its water pump output in SerDia while the key is on.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:Engine - Glow plug control / Electrical water pump - Voltage above normal or shorted to high source
Deutz SPN 523914 FMI 4Glow plug control / Electrical water pump: Voltage low / shorted low
The EMR4 sees the output for the glow plug control / electrical water pump driver (on the glow plug control unit) at a voltage below normal, as if the circuit is shorted to ground. The controller cannot drive the actuator correctly. Deutz list: KWP code 79, blink code 721. For this code the controller read the glow plug control / Electrical water pump circuit at a voltage below normal, as if it were tied to ground, which points to a wire rubbing through on the frame or a part shorted to its housing. The glow plug control unit is a separate module with its own diagnostic line to the EMR4. The usual symptom is a load that never switches on, a dead function and a lamp after a few seconds.· Shorted lowShorted lowCheck soonCauses
- Glow plug control / electrical water pump driver winding shorted to its housing
- Water in the connector bridging the pins
- Output wire chafed to ground or the engine block
- Wire pinched against the engine block or frame so the signal is pulled to ground
Checks
- 1Measure the winding resistance of the part and look for a very low value
- 2Check the glow plug control unit supply and ground voltage at key-on
- 3Test each glow plug for resistance and continuity
- 4With the connector unplugged, measure the glow plug control / Electrical water pump signal wire against ground; a low resistance means a harness short, while an open reading sends you to the part itself.
- 5Check the supply fuse and the heavy cable of the glow plug control unit.
- 6Read the glow plug control unit status and its water pump output in SerDia while the key is on.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Engine - Glow plug control / Electrical water pump - Voltage below normal or shorted to low source
Deutz SPN 523914 FMI 5Glow plug control / Electrical water pump: Current low / open circuit
The EMR4 sees too little current through the glow plug control / electrical water pump driver (on the glow plug control unit), which means the circuit is open. The controller commands the actuator but nothing flows. Deutz list: KWP code 76, blink code 721. For this code the controller measured too little current in the glow plug control / Electrical water pump circuit, the signature of an open wire, a pulled-out pin or a burnt-out coil. The glow plug control unit is a separate module with its own diagnostic line to the EMR4. The usual symptom is a load that does not respond at all although the controller commands it.· Open circuitOpen circuitCheck soonCauses
- Connector left unplugged after earlier work
- Glow plug control / electrical water pump driver winding open
- Control unit connector wet
- Terminal pushed back or corroded in its connector so the circuit is open
Checks
- 1Test each glow plug for resistance and continuity
- 2Inspect both ends of the glow plug control / electrical water pump driver circuit (EMR4 plug and part connector) for pins pushed back in the housing
- 3Continuity-test each wire to the matching EMR4 pin
- 4Check the continuity of both wires between the EMR4 plug and the glow plug control / Electrical water pump connector, then the coil resistance, to separate a broken wire from a dead coil.
- 5Check the supply fuse and the heavy cable of the glow plug control unit.
- 6Read the glow plug control unit status and its water pump output in SerDia while the key is on.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Source wording:Engine - Glow plug control / Electrical water pump - Current below normal or open circuit
Deutz SPN 523914 FMI 12Glow plug control / Electrical water pump: Bad device or component
The EMR4 judges the glow plug control / electrical water pump driver (on the glow plug control unit) to be a bad device, meaning the part or its driver electronics no longer respond as a working component. Deutz list: KWP code 77, blink code 721. For this code the glow plug control / Electrical water pump reports an internal fault to the controller, so the electronics inside the part have judged themselves defective. The glow plug control unit is a separate module with its own diagnostic line to the EMR4. The usual symptom is a function that stops at once and will not come back until the part is replaced.· Part or controllerPart or controllerCheck soonCauses
- Internal failure of the glow plug control / electrical water pump driver
- Driver stage in the EMR4 failing
- Control unit connector wet
- Electronics inside the part damaged by heat, water or a voltage spike
Checks
- 1Check the glow plug control unit supply and ground voltage at key-on
- 2Read the glow plug control / electrical water pump driver status in SerDia and run any actuator test
- 3Measure supply voltage and ground at the glow plug control / electrical water pump driver connector with the key on to confirm the part is powered
- 4Check supply voltage and ground at the glow plug control / Electrical water pump connector under load; if both are good the part itself is the likely culprit and a swap with a known good one confirms it.
- 5Check the supply fuse and the heavy cable of the glow plug control unit.
- 6Read the glow plug control unit status and its water pump output in SerDia while the key is on.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Source wording:Engine - Glow plug control / Electrical water pump - Bad intelligent device or component
Actuator relay 22 codes
Deutz SPN 523924 FMI 3Actuator relay 2: Voltage high / shorted high
The EMR4 sees the output for the actuator relay 2 (in the machine or engine harness switched by the EMR4) at a voltage above normal, as if the circuit is shorted to the battery supply. The controller cannot drive the relay or output correctly. Deutz list: KWP code 37, blink code 167. For this code the controller read the actuator relay 2 circuit at a voltage above normal, as if the wire or the driver were pulled up to the supply voltage, for instance by a chafed harness touching a live wire. Actuator relays are free outputs that the machine maker wires to a load of its choice. The usual symptom is a load that stays energised or never switches off, and the lamp comes on at the next key cycle.· Shorted highShorted highCheck soonCauses
- Actuator relay 2 shorted internally
- Relay base corroded
- Output wire shorted to battery positive
- Connector pin touching a live pin
- Harness insulation worn through where it rubs on a bracket, letting the wire touch a live supply
Checks
- 1Identify what actuator relay 2 switches on your machine from the wiring diagram
- 2Swap the relay with a similar one to see whether the fault follows it
- 3With the EMR4 unplugged, measure the output wire to battery positive; it should be open
- 4Unplug the actuator relay 2: if the code stays, the short is in the harness or the EMR4; if it clears, the part is the shorted one
- 5With the EMR4 and the actuator relay 2 unplugged, measure the signal wire against battery positive; it must read open, and any reading means the harness is shorted high.
- 6Read the relay output state in SerDia while forcing the function on the machine, to see whether the controller or the machine is holding it.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:Engine - Actuator relay 2 - Voltage above normal or shorted to high source
Deutz SPN 523924 FMI 4Actuator relay 2: Voltage low / shorted low
The EMR4 sees the output for the actuator relay 2 (in the machine or engine harness switched by the EMR4) at a voltage below normal, as if the circuit is shorted to ground. The controller cannot drive the relay or output correctly. Deutz list: KWP code 42, blink code 167. For this code the controller read the actuator relay 2 circuit at a voltage below normal, as if it were tied to ground, which points to a wire rubbing through on the frame or a part shorted to its housing. Actuator relays are free outputs that the machine maker wires to a load of its choice. The usual symptom is a load that never switches on, a dead function and a lamp after a few seconds.· Shorted lowShorted lowCheck soonCauses
- Relay base corroded
- Actuator relay 2 winding shorted to its housing
- Output wire chafed to ground or the engine block
- Wire pinched against the engine block or frame so the signal is pulled to ground
Checks
- 1With the EMR4 unplugged, measure the output wire to ground; it should not be low ohms
- 2Measure the winding resistance of the part and look for a very low value
- 3Swap the relay with a similar one to see whether the fault follows it
- 4Identify what actuator relay 2 switches on your machine from the wiring diagram
- 5With the connector unplugged, measure the actuator relay 2 signal wire against ground; a low resistance means a harness short, while an open reading sends you to the part itself.
- 6Read the relay output state in SerDia while forcing the function on the machine, to see whether the controller or the machine is holding it.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Engine - Actuator relay 2 - Voltage below normal or shorted to low source
Actuator relay 32 codes
Deutz SPN 523925 FMI 3Actuator relay 3: Voltage high / shorted high
The EMR4 sees the output for the actuator relay 3 (in the machine or engine harness switched by the EMR4) at a voltage above normal, as if the circuit is shorted to the battery supply. The controller cannot drive the relay or output correctly. Deutz list: KWP code 38, blink code 731. For this code the controller read the actuator relay 3 circuit at a voltage above normal, as if the wire or the driver were pulled up to the supply voltage, for instance by a chafed harness touching a live wire. Actuator relays are free outputs that the machine maker wires to a load of its choice. The usual symptom is a load that stays energised or never switches off, and the lamp comes on at the next key cycle.· Shorted highShorted highCheck soonCauses
- Output wire shorted to battery positive
- Connector pin touching a live pin
- Actuator relay 3 shorted internally
- Harness insulation worn through where it rubs on a bracket, letting the wire touch a live supply
Checks
- 1Unplug the actuator relay 3: if the code stays, the short is in the harness or the EMR4; if it clears, the part is the shorted one
- 2With the EMR4 unplugged, measure the output wire to battery positive; it should be open
- 3Measure the winding or coil resistance of the part
- 4With the EMR4 and the actuator relay 3 unplugged, measure the signal wire against battery positive; it must read open, and any reading means the harness is shorted high.
- 5Find in the machine wiring diagram what this relay switches before you test anything.
- 6Read the relay output state in SerDia while forcing the function on the machine, to see whether the controller or the machine is holding it.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:Engine - Actuator relay 3 - Voltage above normal or shorted to high source
Deutz SPN 523925 FMI 4Actuator relay 3: Voltage low / shorted low
The EMR4 sees the output for the actuator relay 3 (in the machine or engine harness switched by the EMR4) at a voltage below normal, as if the circuit is shorted to ground. The controller cannot drive the relay or output correctly. Deutz list: KWP code 43, blink code 731. For this code the controller read the actuator relay 3 circuit at a voltage below normal, as if it were tied to ground, which points to a wire rubbing through on the frame or a part shorted to its housing. Actuator relays are free outputs that the machine maker wires to a load of its choice. The usual symptom is a load that never switches on, a dead function and a lamp after a few seconds.· Shorted lowShorted lowCheck soonCauses
- Output wire chafed to ground or the engine block
- Actuator relay 3 winding shorted to its housing
- Water in the connector bridging the pins
- Wire pinched against the engine block or frame so the signal is pulled to ground
Checks
- 1Unplug the actuator relay 3: if the code changes, the part is the shorted one; if it stays, look at the harness
- 2With the EMR4 unplugged, measure the output wire to ground; it should not be low ohms
- 3Measure the winding resistance of the part and look for a very low value
- 4With the connector unplugged, measure the actuator relay 3 signal wire against ground; a low resistance means a harness short, while an open reading sends you to the part itself.
- 5Find in the machine wiring diagram what this relay switches before you test anything.
- 6Read the relay output state in SerDia while forcing the function on the machine, to see whether the controller or the machine is holding it.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Engine - Actuator relay 3 - Voltage below normal or shorted to low source
Actuator relay 41 code
Deutz SPN 523926 FMI 4Actuator relay 4: Voltage low / shorted low
The EMR4 sees the output for the actuator relay 4 (in the machine or engine harness switched by the EMR4) at a voltage below normal, as if the circuit is shorted to ground. The controller cannot drive the relay or output correctly. Deutz list: KWP code 44, blink code 732. For this code the controller read the actuator relay 4 circuit at a voltage below normal, as if it were tied to ground, which points to a wire rubbing through on the frame or a part shorted to its housing. Actuator relays are free outputs that the machine maker wires to a load of its choice. The usual symptom is a load that never switches on, a dead function and a lamp after a few seconds.· Shorted lowShorted lowCheck soonCauses
- Output wire chafed to ground or the engine block
- Actuator relay 4 winding shorted to its housing
- Water in the connector bridging the pins
- Wire pinched against the engine block or frame so the signal is pulled to ground
Checks
- 1Unplug the actuator relay 4: if the code changes, the part is the shorted one; if it stays, look at the harness
- 2With the EMR4 unplugged, measure the output wire to ground; it should not be low ohms
- 3Measure the winding resistance of the part and look for a very low value
- 4With the connector unplugged, measure the actuator relay 4 signal wire against ground; a low resistance means a harness short, while an open reading sends you to the part itself.
- 5Find in the machine wiring diagram what this relay switches before you test anything.
- 6Read the relay output state in SerDia while forcing the function on the machine, to see whether the controller or the machine is holding it.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Engine - Actuator relay 4 - Voltage below normal or shorted to low source
Actuator relay 62 codes
Deutz SPN 523927 FMI 3Actuator relay 6: Voltage high / shorted high
The EMR4 sees the output for the actuator relay 6 (in the machine or engine harness switched by the EMR4) at a voltage above normal, as if the circuit is shorted to the battery supply. The controller cannot drive the relay or output correctly. Deutz list: KWP code 40, blink code 733. For this code the controller read the actuator relay 6 circuit at a voltage above normal, as if the wire or the driver were pulled up to the supply voltage, for instance by a chafed harness touching a live wire. Actuator relays are free outputs that the machine maker wires to a load of its choice. The usual symptom is a load that stays energised or never switches off, and the lamp comes on at the next key cycle.· Shorted highShorted highCheck soonCauses
- Output wire shorted to battery positive
- Connector pin touching a live pin
- Actuator relay 6 shorted internally
- Harness insulation worn through where it rubs on a bracket, letting the wire touch a live supply
Checks
- 1Unplug the actuator relay 6: if the code stays, the short is in the harness or the EMR4; if it clears, the part is the shorted one
- 2With the EMR4 unplugged, measure the output wire to battery positive; it should be open
- 3Measure the winding or coil resistance of the part
- 4With the EMR4 and the actuator relay 6 unplugged, measure the signal wire against battery positive; it must read open, and any reading means the harness is shorted high.
- 5Find in the machine wiring diagram what this relay switches before you test anything.
- 6Read the relay output state in SerDia while forcing the function on the machine, to see whether the controller or the machine is holding it.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:Engine - Actuator relay 6 - Voltage above normal or shorted to high source
Deutz SPN 523986 FMI 4Actuator relay 6: Voltage low / shorted low
The EMR4 sees the output for the actuator relay 6 (in the machine or engine harness switched by the EMR4) at a voltage below normal, as if the circuit is shorted to ground. The controller cannot drive the relay or output correctly. Deutz list: KWP code 1241, blink code 176. For this code the controller read the actuator relay 6 circuit at a voltage below normal, as if it were tied to ground, which points to a wire rubbing through on the frame or a part shorted to its housing. Actuator relays are free outputs that the machine maker wires to a load of its choice. The usual symptom is a load that never switches on, a dead function and a lamp after a few seconds.· Shorted lowShorted lowCheck soonCauses
- Output wire chafed to ground or the engine block
- Actuator relay 6 winding shorted to its housing
- Water in the connector bridging the pins
- Wire pinched against the engine block or frame so the signal is pulled to ground
Checks
- 1Unplug the actuator relay 6: if the code changes, the part is the shorted one; if it stays, look at the harness
- 2With the EMR4 unplugged, measure the output wire to ground; it should not be low ohms
- 3Measure the winding resistance of the part and look for a very low value
- 4With the connector unplugged, measure the actuator relay 6 signal wire against ground; a low resistance means a harness short, while an open reading sends you to the part itself.
- 5Find in the machine wiring diagram what this relay switches before you test anything.
- 6Read the relay output state in SerDia while forcing the function on the machine, to see whether the controller or the machine is holding it.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Engine - Actuator relay 6 - Voltage below normal or shorted to low source
Actuator relay 72 codes
Deutz SPN 523984 FMI 3Actuator relay 7: Voltage high / shorted high
The EMR4 sees the output for the actuator relay 7 (in the machine or engine harness switched by the EMR4) at a voltage above normal, as if the circuit is shorted to the battery supply. The controller cannot drive the relay or output correctly. Deutz list: KWP code 1239, blink code 788. For this code the controller read the actuator relay 7 circuit at a voltage above normal, as if the wire or the driver were pulled up to the supply voltage, for instance by a chafed harness touching a live wire. Actuator relays are free outputs that the machine maker wires to a load of its choice. The usual symptom is a load that stays energised or never switches off, and the lamp comes on at the next key cycle.· Shorted highShorted highCheck soonCauses
- Output wire shorted to battery positive
- Connector pin touching a live pin
- Actuator relay 7 shorted internally
- Harness insulation worn through where it rubs on a bracket, letting the wire touch a live supply
Checks
- 1Unplug the actuator relay 7: if the code stays, the short is in the harness or the EMR4; if it clears, the part is the shorted one
- 2With the EMR4 unplugged, measure the output wire to battery positive; it should be open
- 3Measure the winding or coil resistance of the part
- 4With the EMR4 and the actuator relay 7 unplugged, measure the signal wire against battery positive; it must read open, and any reading means the harness is shorted high.
- 5Find in the machine wiring diagram what this relay switches before you test anything.
- 6Read the relay output state in SerDia while forcing the function on the machine, to see whether the controller or the machine is holding it.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:Engine - Actuator relay 7 - Voltage above normal or shorted to high source
Deutz SPN 523987 FMI 4Actuator relay 7: Voltage low / shorted low
The EMR4 sees the output for the actuator relay 7 (in the machine or engine harness switched by the EMR4) at a voltage below normal, as if the circuit is shorted to ground. The controller cannot drive the relay or output correctly. Deutz list: KWP code 1242, blink code 791. For this code the controller read the actuator relay 7 circuit at a voltage below normal, as if it were tied to ground, which points to a wire rubbing through on the frame or a part shorted to its housing. Actuator relays are free outputs that the machine maker wires to a load of its choice. The usual symptom is a load that never switches on, a dead function and a lamp after a few seconds.· Shorted lowShorted lowCheck soonCauses
- Output wire chafed to ground or the engine block
- Actuator relay 7 winding shorted to its housing
- Water in the connector bridging the pins
- Wire pinched against the engine block or frame so the signal is pulled to ground
Checks
- 1Unplug the actuator relay 7: if the code changes, the part is the shorted one; if it stays, look at the harness
- 2With the EMR4 unplugged, measure the output wire to ground; it should not be low ohms
- 3Measure the winding resistance of the part and look for a very low value
- 4With the connector unplugged, measure the actuator relay 7 signal wire against ground; a low resistance means a harness short, while an open reading sends you to the part itself.
- 5Find in the machine wiring diagram what this relay switches before you test anything.
- 6Read the relay output state in SerDia while forcing the function on the machine, to see whether the controller or the machine is holding it.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Engine - Actuator relay 7 - Voltage below normal or shorted to low source
Shared checks
Checks, in order
- 1Identify what the relay switches on your machine from the wiring diagram
- 2Swap the relay with a similar one to see whether the fault follows it
- 3Measure the voltage at the output with the key on and the output commanded
- 4Unplug the load: if the code stays, the short is in the harness or the EMR4
- 5Inspect connectors and fuses for water, chafing and pushed-back pins
Causes
- Relay or glow plug control unit failed, or its base corroded
- Output wire shorted to battery or ground, or open
- Starter relay or starter switch circuit fault
- Supply fuse or connector fault in the circuit
Most common here: shorted low (9 of 25)
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
When to stop
You'll notice: A warning lamp or limited function.
Most sensor and wiring faults can be traced with a multimeter and the wiring diagram. Disconnect the battery before unplugging controllers; if the controller itself is suspect or needs programming, that needs the dealer’s service tool.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.