Deutz · Starting and preheat
Deutz Fault Code SPN 729 FMI 3
Engine - Preheating relay - Voltage above normal or shorted to high source
What does Deutz code SPN 729 FMI 3 mean?
The EMR4 sees the output for the preheating relay (in the preheat circuit (glow plug or grid heater) controlled by the EMR4) at a voltage above normal, as if the circuit is shorted to the battery supply. Urgency: check soon - the machine may derate or limit a function. Check first: with the EMR4 unplugged, measure the output wire to battery positive; it should be open.
- SPN 729
- Intake air heater 1
- FMI 3
- Voltage above normal or shorted high
Can I keep running with it?
Check soon
The machine may derate or limit a function. Find the cause before the next shift.
What should I check first?
With the EMR4 unplugged, measure the output wire to battery positive; it should be open
Then 5 more checksWhere to read it
Read the active and stored faults with Deutz SerDia (or the machine maker's diagnostic tool) on the engine diagnostic plug.
Checks
0 of 6 done
Causes
- Output wire shorted to battery positive
- Preheating relay shorted internally
- Relay coil connector corroded
- Harness insulation worn through where it rubs on a bracket, letting the wire touch a live supply
How it failed
You'll notice: Expect a warning lamp; the engine may start hard in cold weather and smoke as the preheat does not work, or the preheat lamp behaves oddly.
Shorted highRead from FMI 3: voltage above normal or shorted high
The signal sits at or near the supply voltage - more than a working sensor can send.
- Meter test
- Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
- Good result
- Open circuit (OL) between them. Any low reading is the short.
When to stop
Most sensor and wiring faults can be traced with a multimeter and the wiring diagram. Disconnect the battery before unplugging controllers; if the controller itself is suspect or needs programming, that needs the dealer’s service tool.
Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Same part, other failures: Actuator relays, starter circuit and glow plug control
7 other codes on this part are also shorted high (SPN 677 FMI 3, SPN 523913 FMI 3, SPN 523914 FMI 3, SPN 523924 FMI 3 and more). When they show together, start at the wiring and connector they share.
- SPN 677 FMI 3Engine - Starter relay - Voltage above normal or shorted to high sourceShorted highCheck soon
- SPN 677 FMI 4Engine - Starter relay - Voltage below normal or shorted to low sourceShorted lowCheck soon
- SPN 677 FMI 5Engine - Starter relay - Current below normal or open circuitOpen circuitCheck soon
- SPN 677 FMI 12Engine - Starter relay - Bad intelligent device or componentPart or controllerCheck soon
- SPN 729 FMI 3Engine - Preheating relay - Voltage above normal or shorted to high sourceShorted highCheck soon
- SPN 729 FMI 4Engine - Preheating relay - Voltage below normal or shorted to low sourceShorted lowCheck soon
- SPN 729 FMI 5Engine - Preheating relay - Current below normal or open circuitOpen circuitCheck soon
- SPN 729 FMI 12Engine - Preheating relay - Bad intelligent device or componentPart or controllerCheck soon
- SPN 523550 FMI 12Engine - Starter switch to long active - Bad intelligent device or componentPart or controllerCheck soon
Show the other 16 codesHide the other codes
- SPN 676 FMI 11Engine - Glow plug relay - Root cause not knownOtherCheck soon
- SPN 523913 FMI 3Engine - Diagnostic cable glow plug control - Voltage above normal or shorted to high sourceShorted highCheck soon
- SPN 523913 FMI 4Engine - Diagnostic cable glow plug control - Voltage below normal or shorted to low sourceShorted lowCheck soon
- SPN 523914 FMI 3Engine - Glow plug control / Electrical water pump - Voltage above normal or shorted to high sourceShorted highCheck soon
- SPN 523914 FMI 4Engine - Glow plug control / Electrical water pump - Voltage below normal or shorted to low sourceShorted lowCheck soon
- SPN 523914 FMI 5Engine - Glow plug control / Electrical water pump - Current below normal or open circuitOpen circuitCheck soon
- SPN 523914 FMI 12Engine - Glow plug control / Electrical water pump - Bad intelligent device or componentPart or controllerCheck soon
- SPN 523924 FMI 3Engine - Actuator relay 2 - Voltage above normal or shorted to high sourceShorted highCheck soon
- SPN 523924 FMI 4Engine - Actuator relay 2 - Voltage below normal or shorted to low sourceShorted lowCheck soon
- SPN 523925 FMI 3Engine - Actuator relay 3 - Voltage above normal or shorted to high sourceShorted highCheck soon
- SPN 523925 FMI 4Engine - Actuator relay 3 - Voltage below normal or shorted to low sourceShorted lowCheck soon
- SPN 523926 FMI 4Engine - Actuator relay 4 - Voltage below normal or shorted to low sourceShorted lowCheck soon
- SPN 523927 FMI 3Engine - Actuator relay 6 - Voltage above normal or shorted to high sourceShorted highCheck soon
- SPN 523984 FMI 3Engine - Actuator relay 7 - Voltage above normal or shorted to high sourceShorted highCheck soon
- SPN 523986 FMI 4Engine - Actuator relay 6 - Voltage below normal or shorted to low sourceShorted lowCheck soon
- SPN 523987 FMI 4Engine - Actuator relay 7 - Voltage below normal or shorted to low sourceShorted lowCheck soon
Related on Equipments Finder
Source
DEUTZ KWP-Codes EMR4 (KWPList EMR4 DE EN, Revision 2.0), page 9
This source lists SPN 729 FMI 3 and its meaning. The guidance on this page is general, not taken from it.
The source covers: Deutz engines with the EMR4 controller (the Deutz list applies to all EMR4 engine series, e.g. TCD 2.9, 3.6, 4.1, 6.1, 7.8 as fitted in machines).
Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?