What the operator touches and sees. The accelerator pedal sensor (SPN 91), switch inputs from the machine, the warning lamps the EMR4 drives, shutdown requests from engine protection or the machine controller, and the GPS and telemetry status.
More about these partsLess
Each code names the input or output and how it failed.
Where to read it
Read the active and stored faults with Deutz SerDia (or the machine maker's diagnostic tool) on the engine diagnostic plug.
What do these codes mean?
Deutz codes SPN 29 FMI 2 to SPN 524286 FMI 2 are all about the operator inputs, warning lamps, shutdown requests and telemetry. The most common failure type is erratic or implausible (7 of 22); 2 need an immediate stop. Start with this check: read the pedal signal in SerDia through its whole travel and look for dropouts.
How urgent are they?
2 of 22 codes here mean stop now; the other 20 can wait until the shift ends, but find the cause before the next one.
- Stop now2
- Check soon20
What should I check first?
Read the pedal signal in SerDia through its whole travel and look for dropouts
Shared checks22 of 22
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
Machine - Position accelerator pedal 2 (remote accelerator pedal 1)3 codes
Deutz SPN 29 FMI 2Machine - Position accelerator pedal 2 (remote accelerator pedal 1): Erratic reading
The EMR4 sees the accelerator pedal 2 (remote pedal 1) (in the second or remote throttle input, such as a hand throttle or second pedal) signal erratic or not agreeing with its partner sensor. That usually means a worn track in the pedal or a loose connection. Deutz list: KWP code 978, blink code 126.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Hand throttle potentiometer worn
- Intermittent contact in the pedal connector
- Remote throttle input wired by the machine maker through a splice that has corroded
Checks
- 1Compare with the second pedal track, which should mirror it
- 2Find out whether your machine actually uses a second throttle input; an unused input left unplugged can log this fault
- 3Move the accelerator pedal 2 (remote pedal 1) slowly through its travel in SerDia and look for jumps
- 4Check the pedal connector for moisture and loose pins
- 5Move the remote or hand throttle through its travel and watch the value in SerDia for steps or dropouts
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Source wording:Machine - Position accelerator pedal 2 (remote accelerator pedal 1) - Data erratic intermittent or incorrect
Deutz SPN 29 FMI 3Machine - Position accelerator pedal 2 (remote accelerator pedal 1): Voltage high / shorted high
The EMR4 reads the accelerator pedal 2 (remote pedal 1) (in the second or remote throttle input, such as a hand throttle or second pedal) above its valid voltage range. For a pedal potentiometer that means an open ground or a signal wire pulled up to supply. Deutz list: KWP code 932, blink code 126.· Shorted highShorted highCheck soonCauses
- Signal wire shorted to the 5 V or battery supply
- Hand throttle potentiometer worn
- Open ground wire to the pedal potentiometer
- Remote throttle input wired by the machine maker through a splice that has corroded
Checks
- 1Unplug the pedal and check the signal pin for a short to supply
- 2Move the remote or hand throttle through its travel and watch the value in SerDia for steps or dropouts
- 3Measure continuity of the pedal ground wire back to the EMR4
- 4Find out whether your machine actually uses a second throttle input; an unused input left unplugged can log this fault
- 5Key on: measure the supply to the accelerator pedal 2 (remote pedal 1) and check it reads 5 V
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:Machine - Position accelerator pedal 2 (remote accelerator pedal 1) - Voltage above normal or shorted to high source
Deutz SPN 29 FMI 4Machine - Position accelerator pedal 2 (remote accelerator pedal 1): Voltage low / shorted low
The EMR4 reads the accelerator pedal 2 (remote pedal 1) (in the second or remote throttle input, such as a hand throttle or second pedal) below its valid voltage range. For a pedal potentiometer that means a shorted signal wire or a lost 5 V reference. Deutz list: KWP code 937, blink code 126.· Shorted lowShorted lowCheck soonCauses
- Signal wire rubbed through to ground
- 5 V supply to the pedal lost or open
- Hand throttle potentiometer worn
Checks
- 1Find out whether your machine actually uses a second throttle input; an unused input left unplugged can log this fault
- 2Check the harness where it flexes at the pedal or throttle lever
- 3Key on: measure the 5 V supply at the accelerator pedal 2 (remote pedal 1) plug
- 4Unplug the pedal and measure resistance from signal to ground, which should not be near zero
- 5Move the remote or hand throttle through its travel and watch the value in SerDia for steps or dropouts
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Machine - Position accelerator pedal 2 (remote accelerator pedal 1) - Voltage below normal or shorted to low source
Machine - Position accelerator pedal (sensor 1)3 codes
Deutz SPN 91 FMI 3Machine - Position accelerator pedal (sensor 1): Voltage high / shorted high
The EMR4 reads the accelerator pedal (sensor 1) (in the operator pedal or hand throttle assembly) above its valid voltage range. For a pedal potentiometer that means an open ground or a signal wire pulled up to supply. Deutz list: KWP code 935, blink code 226.· Shorted highShorted highCheck soonCauses
- Pedal connector contaminated by washdown water
- Signal wire shorted to the 5 V or battery supply
- Open ground wire to the pedal potentiometer
Checks
- 1Sweep the pedal slowly through its whole travel with SerDia open and watch for dropouts or steps in the percentage
- 2Key on: measure the supply to the accelerator pedal (sensor 1) and check it reads 5 V
- 3Unplug the pedal and check the signal pin for a short to supply
- 4Check the machine-maker pedal connector and any splice into the engine harness, not just the engine side
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:Machine - Position accelerator pedal (sensor 1) - Voltage above normal or shorted to high source
Full page for SPN 91 FMI 3Deutz SPN 91 FMI 4Machine - Position accelerator pedal (sensor 1): Voltage low / shorted low
The EMR4 reads the accelerator pedal (sensor 1) (in the operator pedal or hand throttle assembly) below its valid voltage range. For a pedal potentiometer that means a shorted signal wire or a lost 5 V reference. Deutz list: KWP code 940, blink code 226.· Shorted lowShorted lowCheck soonCauses
- Worn track inside the pedal potentiometer
- Pedal connector contaminated by washdown water
- 5 V supply to the pedal lost or open
- Signal wire rubbed through to ground
Checks
- 1Key on: measure the 5 V supply at the accelerator pedal (sensor 1) plug
- 2Unplug the pedal and measure resistance from signal to ground, which should not be near zero
- 3Check the harness where it flexes at the pedal or throttle lever
- 4Sweep the pedal slowly through its whole travel with SerDia open and watch for dropouts or steps in the percentage
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Machine - Position accelerator pedal (sensor 1) - Voltage below normal or shorted to low source
Deutz SPN 91 FMI 11Machine - Position accelerator pedal (sensor 1): Root cause not known
The EMR4 logged a fault on the accelerator pedal (sensor 1) (in the operator pedal or hand throttle assembly) but could not classify the cause. Test the supply, ground and signal in turn. Deutz list: KWP code 976, blink code 226.· OtherOtherCheck soonCauses
- Intermittent wiring fault
- Worn track inside the pedal potentiometer
- Pedal connector contaminated by washdown water
Checks
- 1Measure supply, ground and signal at the pedal plug
- 2Check the machine-maker pedal connector and any splice into the engine harness, not just the engine side
- 3Sweep the pedal slowly through its whole travel with SerDia open and watch for dropouts or steps in the percentage
- 4Read the full SerDia list for a clearer pedal code
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Machine - Amber warning lamp4 codes
Deutz SPN 624 FMI 3Machine - Amber warning lamp: Voltage high / shorted high
The EMR4 sees the output for the amber warning lamp (in the instrument panel or machine display, driven by the EMR4 output) at a voltage above normal, as if the circuit is shorted to the battery supply. The controller cannot drive the relay or output correctly. Deutz list: KWP code 971, blink code 513.· Shorted highShorted highCheck soonCauses
- Connector pin touching a live pin
- Amber warning lamp shorted internally
- Output wire shorted to battery positive
Checks
- 1Trace the lamp wire from the EMR4 pin to the panel for damage
- 2Check the lamp comes on briefly at key-on as the bulb test; no bulb test points at the lamp or its wire
- 3With the EMR4 unplugged, measure the output wire to battery positive; it should be open
- 4Measure the winding or coil resistance of the part
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:Machine - Amber warning lamp - Voltage above normal or shorted to high source
Deutz SPN 624 FMI 4Machine - Amber warning lamp: Voltage low / shorted low
The EMR4 sees the output for the amber warning lamp (in the instrument panel or machine display, driven by the EMR4 output) at a voltage below normal, as if the circuit is shorted to ground. The controller cannot drive the relay or output correctly. Deutz list: KWP code 972, blink code 513.· Shorted lowShorted lowCheck soonCauses
- Output wire chafed to ground or the engine block
- Amber warning lamp winding shorted to its housing
- Water in the connector bridging the pins
Checks
- 1Measure the winding resistance of the part and look for a very low value
- 2Check the lamp comes on briefly at key-on as the bulb test; no bulb test points at the lamp or its wire
- 3Trace the lamp wire from the EMR4 pin to the panel for damage
- 4With the EMR4 unplugged, measure the output wire to ground; it should not be low ohms
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Machine - Amber warning lamp - Voltage below normal or shorted to low source
Deutz SPN 624 FMI 5Machine - Amber warning lamp: Current low / open circuit
The EMR4 sees too little current through the amber warning lamp (in the instrument panel or machine display, driven by the EMR4 output), which means the circuit is open. The controller commands the relay or output but nothing flows. Deutz list: KWP code 969, blink code 513.· Open circuitOpen circuitCheck soonCauses
- Lamp bulb or LED failed
- Broken wire or a pin pushed out of the connector
- Amber warning lamp winding open
Checks
- 1Continuity-test each wire to the matching EMR4 pin
- 2Inspect both ends of the amber warning lamp circuit (EMR4 plug and part connector) for pins pushed back in the housing
- 3Measure the resistance across the amber warning lamp terminals: infinity means an open winding
- 4Check the lamp comes on briefly at key-on as the bulb test; no bulb test points at the lamp or its wire
- 5Trace the lamp wire from the EMR4 pin to the panel for damage
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Source wording:Machine - Amber warning lamp - Current below normal or open circuit
Deutz SPN 624 FMI 12Machine - Amber warning lamp: Bad device or component
The EMR4 judges the amber warning lamp (in the instrument panel or machine display, driven by the EMR4 output) to be a bad device, meaning the part or its driver electronics no longer respond as a working component. Deutz list: KWP code 970, blink code 513.· Part or controllerPart or controllerCheck soonCauses
- Lamp bulb or LED failed
- Internal failure of the amber warning lamp
- Water or soot inside the part
Checks
- 1Trace the lamp wire from the EMR4 pin to the panel for damage
- 2Check the lamp comes on briefly at key-on as the bulb test; no bulb test points at the lamp or its wire
- 3Measure supply voltage and ground at the amber warning lamp connector with the key on to confirm the part is powered
- 4Read the amber warning lamp status in SerDia and run any actuator test
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Source wording:Machine - Amber warning lamp - Bad intelligent device or component
Engine - Protection system requested shutdown1 code
Deutz SPN 1109 FMI 2Engine - Protection system requested shutdown: Erratic reading
The EMR4 reports the engine protection system requested a shutdown, with erratic data. The protection logic is no longer getting reliable inputs. Deutz list: KWP code 121, blink code 341.· Erratic or implausibleErratic or implausibleStop nowCauses
- Oil pressure or coolant sensor failing
- Intermittent connection on a protection sensor
- Wiring fault on the protection input
Checks
- 1Check the oil pressure, coolant temperature and coolant level readings in SerDia for implausible values
- 2Wiggle the sensor harnesses and check their connectors for loose pins
- 3Check the engine oil level and the coolant level by eye, because real low levels trigger protection
- 4Look at which protection input flickers while the engine runs
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Source wording:Engine - Protection system requested shutdown - Data erratic intermittent or incorrect
Engine - Shutdown override switch1 code
Deutz SPN 1237 FMI 2Engine - Shutdown override switch: Erratic reading
The EMR4 reports the shutdown override switch signal erratic. The override input that lets the operator bypass an engine shutdown is unstable. Deutz list: KWP code 747, blink code 145.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Override switch worn or sticking
- Intermittent connector
- Wiring chafed
Checks
- 1Operate the override switch and watch the input state in SerDia to see whether it follows the switch
- 2Check the override switch contacts for wear or corrosion
- 3Check the wiring from the switch to the EMR4 for chafing and loose terminals
- 4Check the machine wiring diagram to confirm which pin carries the override input
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Source wording:Engine - Shutdown override switch - Data erratic intermittent or incorrect
Machine - Pre selection switch engine brake1 code
Deutz SPN 523090 FMI 2Machine - Pre selection switch engine brake: Erratic reading
The EMR4 sees the pre selection switch engine brake (on the machine and read by the EMR4) erratic, intermittent or implausible. The signal is present but unsteady or disagrees with other values. Deutz list: KWP code 362, blink code 329.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Intermittent contact in a connector or a pin with fretting
- Harness chafed where it moves with vibration
Checks
- 1Watch the pre selection switch engine brake value in SerDia while wiggling the harness and connector and note when it jumps
- 2Compare it with a related value, since a lone odd reading points at the circuit or part itself
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Source wording:Machine - Pre selection switch engine brake - Data erratic intermittent or incorrect
Engine - Shut down request from internal ECU monitoring1 code
Deutz SPN 523698 FMI 11Engine - Shut down request from internal ECU monitoring: Root cause not known
The EMR4 reports a shut down request from its internal monitoring, cause not known. The controller itself decided to stop the engine because of a condition it checks. Deutz list: KWP code 122, blink code 591.· OtherOtherStop nowCauses
- A critical sensor or supply fault that triggered the shutdown
- ECU internal monitoring failure
- Wiring fault on an engine protection input
Checks
- 1Read the full fault list and freeze frames in SerDia to see what happened just before the shutdown
- 2Check battery supply stability at the EMR4 connector during cranking and running
- 3Check the main grounds between the ECU, engine block and frame
- 4Look for an active protection code (oil pressure, coolant temperature, speed) that explains the shutdown
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Machine - CAN shut down request from engine shut down1 code
Deutz SPN 523741 FMI 14Machine - CAN shut down request from engine shut down: Special instructions
The EMR4 flags a CAN shut down request from the engine shut down function as special instructions. The machine requested or received an engine stop via CAN. Deutz list: KWP code 172, blink code 618.· Lost messageLost messageCheck soonCauses
- Machine controller commanded a shutdown
- A machine protection condition
- CAN fault sending a wrong request
Checks
- 1Check the machine controller for its own fault codes that explain why it asked for a shutdown
- 2Read the shutdown reason and the freeze frame in SerDia
- 3Check the CAN wiring for a fault that could send a wrong shutdown request
- 4Check protection inputs the machine uses, such as hydraulic oil temperature or emergency stop
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Engine - EAT/SCR inducement or DEF level lamp / collective error lamp (water in fuel & fuel pressure & air filter clogged)4 codes
Deutz SPN 524087 FMI 3Engine - EAT/SCR inducement or DEF level lamp / collective error lamp (water in fuel & fuel pressure & air filter clogged): Voltage high / shorted high
The EMR4 sees the output for the EAT/SCR inducement lamp or collective error lamp (in the instrument panel, driven by the EMR4) at a voltage above normal, as if the circuit is shorted to the battery supply. The controller cannot drive the relay or output correctly. Deutz list: KWP code 1621, blink code 884.· Shorted highShorted highCheck soonCauses
- EAT/SCR inducement lamp or collective error lamp shorted internally
- Connector pin touching a live pin
- Lamp bulb or LED failed
- Output wire shorted to battery positive
Checks
- 1Measure the winding or coil resistance of the part
- 2Unplug the EAT/SCR inducement lamp or collective error lamp: if the code stays, the short is in the harness or the EMR4; if it clears, the part is the shorted one
- 3Trace the lamp wire from the EMR4 pin to the panel for damage
- 4With the EMR4 unplugged, measure the output wire to battery positive; it should be open
- 5Check that the lamp does a bulb test at key-on
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:Engine - EAT/SCR inducement or DEF level lamp / collective error lamp (water in fuel & fuel pressure & air filter clogged) - Voltage above normal or shorted to high source
Deutz SPN 524087 FMI 4Engine - EAT/SCR inducement or DEF level lamp / collective error lamp (water in fuel & fuel pressure & air filter clogged): Voltage low / shorted low
The EMR4 sees the output for the EAT/SCR inducement lamp or collective error lamp (in the instrument panel, driven by the EMR4) at a voltage below normal, as if the circuit is shorted to ground. The controller cannot drive the relay or output correctly. Deutz list: KWP code 1622, blink code 884.· Shorted lowShorted lowCheck soonCauses
- Water in the connector bridging the pins
- Output wire chafed to ground or the engine block
- Lamp bulb or LED failed
- EAT/SCR inducement lamp or collective error lamp winding shorted to its housing
Checks
- 1Check that the lamp does a bulb test at key-on
- 2Measure the winding resistance of the part and look for a very low value
- 3With the EMR4 unplugged, measure the output wire to ground; it should not be low ohms
- 4Trace the lamp wire from the EMR4 pin to the panel for damage
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Engine - EAT/SCR inducement or DEF level lamp / collective error lamp (water in fuel & fuel pressure & air filter clogged) - Voltage below normal or shorted to low source
Deutz SPN 524087 FMI 5Engine - EAT/SCR inducement or DEF level lamp / collective error lamp (water in fuel & fuel pressure & air filter clogged): Current low / open circuit
The EMR4 sees too little current through the EAT/SCR inducement lamp or collective error lamp (in the instrument panel, driven by the EMR4), which means the circuit is open. The controller commands the relay or output but nothing flows. Deutz list: KWP code 1619, blink code 884.· Open circuitOpen circuitCheck soonCauses
- EAT/SCR inducement lamp or collective error lamp winding open
- Broken wire or a pin pushed out of the connector
- Connector left unplugged after earlier work
Checks
- 1Trace the lamp wire from the EMR4 pin to the panel for damage
- 2Continuity-test each wire to the matching EMR4 pin
- 3Measure the resistance across the EAT/SCR inducement lamp or collective error lamp terminals: infinity means an open winding
- 4Check that the lamp does a bulb test at key-on
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Source wording:Engine - EAT/SCR inducement or DEF level lamp / collective error lamp (water in fuel & fuel pressure & air filter clogged) - Current below normal or open circuit
Deutz SPN 524087 FMI 12Engine - EAT/SCR inducement or DEF level lamp / collective error lamp (water in fuel & fuel pressure & air filter clogged): Bad device or component
The EMR4 judges the EAT/SCR inducement lamp or collective error lamp (in the instrument panel, driven by the EMR4) to be a bad device, meaning the part or its driver electronics no longer respond as a working component. Deutz list: KWP code 1620, blink code 884.· Part or controllerPart or controllerCheck soonCauses
- Water or soot inside the part
- Internal failure of the EAT/SCR inducement lamp or collective error lamp
- Lamp bulb or LED failed
- Driver stage in the EMR4 failing
Checks
- 1Measure supply voltage and ground at the EAT/SCR inducement lamp or collective error lamp connector with the key on to confirm the part is powered
- 2Fit a known good EAT/SCR inducement lamp or collective error lamp if you can borrow one and see whether the code clears for good
- 3Read the EAT/SCR inducement lamp or collective error lamp status in SerDia and run any actuator test
- 4Check that the lamp does a bulb test at key-on
- 5Trace the lamp wire from the EMR4 pin to the panel for damage
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Source wording:Engine - EAT/SCR inducement or DEF level lamp / collective error lamp (water in fuel & fuel pressure & air filter clogged) - Bad intelligent device or component
Machine - Override switch1 code
Deutz SPN 524133 FMI 2Machine - Override switch: Erratic reading
The EMR4 sees the override switch (on the machine and read by the EMR4) erratic, intermittent or implausible. The signal is present but unsteady or disagrees with other values. Deutz list: KWP code 1698, blink code 956.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Intermittent contact in a connector or a pin with fretting
- Harness chafed where it moves with vibration
Checks
- 1Watch the override switch value in SerDia while wiggling the harness and connector and note when it jumps
- 2Compare it with a related value, since a lone odd reading points at the circuit or part itself
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Source wording:Machine - Override switch - Data erratic intermittent or incorrect
Machine - GPS status error1 code
Deutz SPN 524285 FMI 2Machine - GPS status error: Erratic reading
The EMR4 sees the GPS status error (on the telematics unit of the machine) erratic, intermittent or implausible. The signal is present but unsteady or disagrees with other values. Deutz list: KWP code 1471, blink code 1143.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Intermittent contact in a connector or a pin with fretting
- Harness chafed where it moves with vibration
Checks
- 1Watch the GPS status error value in SerDia while wiggling the harness and connector and note when it jumps
- 2Compare it with a related value, since a lone odd reading points at the circuit or part itself
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Source wording:Machine - GPS status error - Data erratic intermittent or incorrect
Machine - Telemetry status error1 code
Deutz SPN 524286 FMI 2Machine - Telemetry status error: Erratic reading
The EMR4 sees the telemetry status error (on the telematics unit of the machine) erratic, intermittent or implausible. The signal is present but unsteady or disagrees with other values. Deutz list: KWP code 1472, blink code 1144.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Intermittent contact in a connector or a pin with fretting
- Harness chafed where it moves with vibration
Checks
- 1Watch the telemetry status error value in SerDia while wiggling the harness and connector and note when it jumps
- 2Compare it with a related value, since a lone odd reading points at the circuit or part itself
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Source wording:Machine - Telemetry status error - Data erratic intermittent or incorrect
Shared checks
Checks, in order
- 1Read the pedal signal in SerDia through its whole travel and look for dropouts
- 2Check the switch or lamp circuit from the machine wiring diagram, at the engine connector
- 3Find out what asked for the shutdown from the freeze frame data
- 4Inspect the connectors for moisture and bent pins
Causes
- Accelerator pedal sensor, its 5 V supply or ground faulty
- Switch or lamp wiring in the machine harness open or shorted
- Machine controller requesting a shutdown or limit for its own reasons
- Telemetry unit without supply or signal
Most common here: erratic or implausible (7 of 22)
Watch the live value on the service tool while you flex the harness and tap the connector.
When to stop
You'll notice: A warning lamp or limited function.
Most sensor and wiring faults can be traced with a multimeter and the wiring diagram. Disconnect the battery before unplugging controllers; if the controller itself is suspect or needs programming, that needs the dealer’s service tool.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.