Deutz · EGR
Deutz EGR and intake throttle valves fault codes
The smart valves that steer exhaust gas recirculation and intake air: the EGR actuator (valve and its position feedback) and the EGR and intake throttle valve. The EMR4 sends each a target position and reads back the position and status.
More about these partsLess
Each code names the valve and whether its drive, its position signal or its movement failed.
Where to read it
Read the active and stored faults with Deutz SerDia (or the machine maker's diagnostic tool) on the engine diagnostic plug.
What do these codes mean?
Deutz codes SPN 51 FMI 0 to SPN 524281 FMI 6 are all about the eGR and intake throttle valves. The most common failure type is part or controller (8 of 23); none needs an immediate stop. Start with this check: remove the valve and look for carbon build-up; move it by hand with the key off.
How urgent are they?
None of the 23 codes here means stop now; all 23 can wait until the shift ends, but find the cause before the next one.
- Check soon23
What should I check first?
Remove the valve and look for carbon build-up; move it by hand with the key off
Shared checks23 of 23
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
Throttle valve / Throttle valve position9 codes
Deutz SPN 51 FMI 0Throttle valve / Throttle valve position: Reading too high· most severe
The EMR4 sees the intake throttle valve (in the intake path, used by the EMR4 for EGR flow control) above its allowed range. The controller treats this as a serious level. Deutz list: KWP code 1423, blink code 594. For this code the controller rates the throttle valve / Throttle valve position value as above its allowed range; the value may be real or a plausibility limit tripped. The throttle valve position sensor is read as the flap angle, so the flap itself and its feedback share one connector.· Real conditionReal conditionCheck soonCauses
- Throttle flap seized with soot or oil build-up
- Valve flap stuck with soot
- Part driven beyond its limit
- Actuator connector corroded
- Condition really above the limit, for example from overload or a blockage
Checks
- 1Inspect the supply and control wiring of the intake throttle valve for chafe, water and corrosion
- 2Check the intake throttle valve moves freely through its range by hand with the key off
- 3Remove the intake pipe and check the flap moves freely by hand, with the key off
- 4Compare commanded and actual valve position in SerDia while sweeping the throttle valve
- 5Read the actual value against the target in SerDia
- 6Compare the throttle valve / Throttle valve position reading in SerDia with an independent measurement to see whether the high value is real.
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Source wording:Engine - Throttle valve / Throttle valve position - Data above normal operational range (Most severe level)
Deutz SPN 51 FMI 1Throttle valve / Throttle valve position: Reading too low· most severe
The EMR4 sees the intake throttle valve (in the intake path, used by the EMR4 for EGR flow control) below its allowed range. The part is not reaching the position or output the controller commands, and it treats the shortfall as serious. Deutz list: KWP code 1424, blink code 594. For this code the controller rates the throttle valve / Throttle valve position value as below its allowed range; the value may be real or a plausibility limit tripped. The throttle valve position sensor is read as the flap angle, so the flap itself and its feedback share one connector.· Real conditionReal conditionCheck soonCauses
- Part not reaching its commanded value
- Throttle flap seized with soot or oil build-up
- Actuator connector corroded
- Valve flap stuck with soot
- Condition really below the limit, for example from a leak or a weak supply
Checks
- 1Read the actual value against the target in SerDia
- 2Compare commanded and actual valve position in SerDia while sweeping the throttle valve
- 3Inspect the supply and control wiring of the intake throttle valve for chafe, water and corrosion
- 4Remove the intake pipe and check the flap moves freely by hand, with the key off
- 5Check the part moves through its full travel by hand with the key off
- 6Compare the throttle valve / Throttle valve position reading in SerDia with an independent measurement to see whether the low value is real.
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Source wording:Engine - Throttle valve / Throttle valve position - Data below normal operational range (Most severe level)
Deutz SPN 51 FMI 3Throttle valve / Throttle valve position: Voltage high / shorted high
The EMR4 sees the output for the intake throttle valve (in the intake path, used by the EMR4 for EGR flow control) at a voltage above normal, as if the circuit is shorted to the battery supply. The controller cannot drive the actuator correctly. Deutz list: KWP code 1024, blink code 594. For this code the controller read the throttle valve / Throttle valve position circuit at a voltage above normal, as if the wire or the driver were pulled up to the supply voltage, for instance by a chafed harness touching a live wire. The throttle valve position sensor is read as the flap angle, so the flap itself and its feedback share one connector.· Shorted highShorted highCheck soonCauses
- Connector pin touching a live pin
- Output wire shorted to battery positive
- Intake throttle valve shorted internally
- Harness insulation worn through where it rubs on a bracket, letting the wire touch a live supply
Checks
- 1Remove the intake pipe and check the flap moves freely by hand, with the key off
- 2Measure the winding or coil resistance of the part
- 3Compare commanded and actual valve position in SerDia while sweeping the throttle valve
- 4With the EMR4 unplugged, measure the output wire to battery positive; it should be open
- 5With the EMR4 and the throttle valve / Throttle valve position unplugged, measure the signal wire against battery positive; it must read open, and any reading means the harness is shorted high.
- 6Look at the flap through the intake pipe with the key on: it should move and then rest at the commanded angle.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:Engine - Throttle valve / Throttle valve position - Voltage above normal or shorted to high source
Deutz SPN 51 FMI 4Throttle valve / Throttle valve position: Voltage low / shorted low
The EMR4 sees the output for the intake throttle valve (in the intake path, used by the EMR4 for EGR flow control) at a voltage below normal, as if the circuit is shorted to ground. The controller cannot drive the actuator correctly. Deutz list: KWP code 1025, blink code 594. For this code the controller read the throttle valve / Throttle valve position circuit at a voltage below normal, as if it were tied to ground, which points to a wire rubbing through on the frame or a part shorted to its housing. The throttle valve position sensor is read as the flap angle, so the flap itself and its feedback share one connector.· Shorted lowShorted lowCheck soonCauses
- Valve flap stuck with soot
- Output wire chafed to ground or the engine block
- Intake throttle valve winding shorted to its housing
- Water in the connector bridging the pins
- Wire pinched against the engine block or frame so the signal is pulled to ground
Checks
- 1Measure the winding resistance of the part and look for a very low value
- 2Remove the intake pipe and check the flap moves freely by hand, with the key off
- 3Compare commanded and actual valve position in SerDia while sweeping the throttle valve
- 4Unplug the intake throttle valve: if the code changes, the part is the shorted one; if it stays, look at the harness
- 5With the connector unplugged, measure the throttle valve / Throttle valve position signal wire against ground; a low resistance means a harness short, while an open reading sends you to the part itself.
- 6Look at the flap through the intake pipe with the key on: it should move and then rest at the commanded angle.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Engine - Throttle valve / Throttle valve position - Voltage below normal or shorted to low source
Deutz SPN 51 FMI 5Throttle valve / Throttle valve position: Current low / open circuit
The EMR4 sees too little current through the intake throttle valve (in the intake path, used by the EMR4 for EGR flow control), which means the circuit is open. The controller commands the actuator but nothing flows. Deutz list: KWP code 1015, blink code 594. For this code the controller measured too little current in the throttle valve / Throttle valve position circuit, the signature of an open wire, a pulled-out pin or a burnt-out coil. The throttle valve position sensor is read as the flap angle, so the flap itself and its feedback share one connector.· Open circuitOpen circuitCheck soonCauses
- Connector left unplugged after earlier work
- Intake throttle valve winding open
- Valve flap stuck with soot
- Broken wire or a pin pushed out of the connector
- Terminal pushed back or corroded in its connector so the circuit is open
Checks
- 1Remove the intake pipe and check the flap moves freely by hand, with the key off
- 2Continuity-test each wire to the matching EMR4 pin
- 3Measure the resistance across the intake throttle valve terminals: infinity means an open winding
- 4Compare commanded and actual valve position in SerDia while sweeping the throttle valve
- 5Inspect both ends of the intake throttle valve circuit (EMR4 plug and part connector) for pins pushed back in the housing
- 6Check the continuity of both wires between the EMR4 plug and the throttle valve / Throttle valve position connector, then the coil resistance, to separate a broken wire from a dead coil.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Source wording:Engine - Throttle valve / Throttle valve position - Current below normal or open circuit
Deutz SPN 51 FMI 6Throttle valve / Throttle valve position: Current high / grounded
The EMR4 sees too much current through the intake throttle valve (in the intake path, used by the EMR4 for EGR flow control). A shorted winding or wiring fault is drawing more current than the controller allows. Deutz list: KWP code 1014, blink code 594. For this code the controller measured too much current in the throttle valve / Throttle valve position circuit and switched the driver off to protect itself, typically because of a shorted winding or a wire grounded in the harness. The throttle valve position sensor is read as the flap angle, so the flap itself and its feedback share one connector.· Shorted lowShorted lowCheck soonCauses
- Wire chafed to ground
- Valve flap stuck with soot
- Throttle flap seized with soot or oil build-up
- Winding of the coil shorted turn to turn after heat or vibration
Checks
- 1Check the wiring for chafe and for water in the connector
- 2Compare commanded and actual valve position in SerDia while sweeping the throttle valve
- 3Measure the intake throttle valve winding resistance; a low value means it is shorting
- 4Move the part by hand with the key off to see whether it is seized
- 5Remove the intake pipe and check the flap moves freely by hand, with the key off
- 6Measure the coil resistance of the throttle valve / Throttle valve position and compare it with a good one; a value far too low means a shorted winding, and unplugging the part to see whether the code clears shows which side is at fault.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Engine - Throttle valve / Throttle valve position - Current above normal or grounded circuit
Deutz SPN 51 FMI 7Throttle valve / Throttle valve position: Not responding / out of adjustment
The EMR4 sees the intake throttle valve (in the intake path, used by the EMR4 for EGR flow control) not following its commanded position or movement. The signal is fine; the part itself is not moving as it should. Deutz list: KWP code 1016, blink code 594. For this code the throttle valve / Throttle valve position was commanded but did not follow, so the fault is mechanical (sticking, wear or soot) rather than electrical. The throttle valve position sensor is read as the flap angle, so the flap itself and its feedback share one connector.· Part or controllerPart or controllerCheck soonCauses
- Valve flap stuck with soot
- Actuator connector corroded
- Throttle flap seized with soot or oil build-up
- Soot, carbon or dried residue binding the moving parts
Checks
- 1Command it from SerDia and watch actual position against commanded
- 2Inspect for soot, oil or foreign matter around the part
- 3Remove the intake pipe and check the flap moves freely by hand, with the key off
- 4Compare commanded and actual valve position in SerDia while sweeping the throttle valve
- 5Move the throttle valve / Throttle valve position by hand with the key off to feel for sticking, play or soot before you test the electrics.
- 6Look at the flap through the intake pipe with the key on: it should move and then rest at the commanded angle.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Source wording:Engine - Throttle valve / Throttle valve position - Mechanical system not responding or out of adjustment
Deutz SPN 51 FMI 11Throttle valve / Throttle valve position: Root cause not known
The EMR4 logged a fault on the intake throttle valve (in the intake path, used by the EMR4 for EGR flow control) but could not classify the cause. Test the circuit and the part separately. Deutz list: KWP codes 1231 and 2059, blink code 594. For this code the controller flagged the throttle valve / Throttle valve position but could not tell whether wiring, part or supply is to blame. The throttle valve position sensor is read as the flap angle, so the flap itself and its feedback share one connector.· OtherOtherCheck soonCauses
- Intermittent wiring fault
- Failing intake throttle valve
- Intermittent contact that left no clear electrical signature
Checks
- 1Read the full SerDia fault list; this code often sits next to a clearer one on the intake throttle valve
- 2Measure the supply and ground at the intake throttle valve plug with the key on to confirm it is powered
- 3Inspect the intake throttle valve plug and harness for chafed insulation, bent pins and moisture
- 4Read the freeze frame stored with the throttle valve / Throttle valve position fault and note speed, load and battery voltage at the moment it was logged.
- 5Look at the flap through the intake pipe with the key on: it should move and then rest at the commanded angle.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Deutz SPN 51 FMI 12Throttle valve / Throttle valve position: Bad device or component
The EMR4 judges the intake throttle valve (in the intake path, used by the EMR4 for EGR flow control) to be a bad device, meaning the part or its driver electronics no longer respond as a working component. Deutz list: KWP code 1932, blink code 5-9-4. For this code the throttle valve / Throttle valve position reports an internal fault to the controller, so the electronics inside the part have judged themselves defective. The throttle valve position sensor is read as the flap angle, so the flap itself and its feedback share one connector.· Part or controllerPart or controllerCheck soonCauses
- Water or soot inside the part
- Internal failure of the intake throttle valve
- Driver stage in the EMR4 failing
- Electronics inside the part damaged by heat, water or a voltage spike
Checks
- 1Read the intake throttle valve status in SerDia and run any actuator test
- 2Remove the intake pipe and check the flap moves freely by hand, with the key off
- 3Measure supply voltage and ground at the intake throttle valve connector with the key on to confirm the part is powered
- 4Compare commanded and actual valve position in SerDia while sweeping the throttle valve
- 5Check supply voltage and ground at the throttle valve / Throttle valve position connector under load; if both are good the part itself is the likely culprit and a swap with a known good one confirms it.
- 6Look at the flap through the intake pipe with the key on: it should move and then rest at the commanded angle.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Source wording:Engine - Throttle valve / Throttle valve position - Bad intelligent device or component
EGR actuator13 codes
Deutz SPN 2791 FMI 0EGR actuator: Reading too high· most severe
The EMR4 sees the EGR actuator (EGR valve) (on the exhaust gas recirculation line between exhaust manifold and intake) above its allowed range. The controller treats this as a serious level. Deutz list: KWP code 1763, blink code 415. For this code the controller rates the EGR actuator value as above its allowed range; the value may be real or a plausibility limit tripped. The EGR actuator is the valve that meters recirculated exhaust and sits in the hottest part of the engine.· Real conditionReal conditionCheck soonCauses
- Actuator position sensor drifting
- EGR valve plate seized with carbon deposits
- Soot sticking the EGR valve plate
- Condition really above the limit, for example from overload or a blockage
Checks
- 1Compare commanded and actual EGR position in SerDia while exercising the valve
- 2Read the actual value against the target in SerDia
- 3Inspect the EGR valve for sooting and check it moves freely
- 4Check the EGR actuator (EGR valve) moves freely through its range by hand with the key off
- 5Compare the EGR actuator reading in SerDia with an independent measurement to see whether the high value is real.
- 6Check the heat shield and the connector of the EGR actuator for melted plastic, since heat is the usual killer.
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Source wording:Engine - EGR actuator - Data above normal operational range (Most severe level)
Deutz SPN 2791 FMI 2EGR actuator: Erratic reading
The EMR4 sees the EGR actuator (EGR valve) (on the exhaust gas recirculation line between exhaust manifold and intake) behave erratically against the command, which can mean a sticking part or an intermittent connection. Deutz list: KWP code 1753, blink code 415. For this code the EGR actuator signal is erratic: it jumps or does not agree with what the controller expects, which usually means an intermittent contact. The EGR actuator is the valve that meters recirculated exhaust and sits in the hottest part of the engine.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Actuator position sensor drifting
- EGR valve plate seized with carbon deposits
- Intermittent contact in the connector
- Loose pin or damaged wire that makes the signal drop out
Checks
- 1Compare commanded and actual EGR position in SerDia while exercising the valve
- 2Inspect the EGR valve for sooting and check it moves freely
- 3Command the EGR actuator (EGR valve) from SerDia and watch actual versus commanded behaviour for lag or dropouts
- 4Wiggle the EGR actuator (EGR valve) harness and connector while watching the live status in SerDia for dropouts
- 5Wiggle the harness at the EGR actuator while watching the live value in SerDia; a jump exposes a loose pin or a chafed wire.
- 6Check the heat shield and the connector of the EGR actuator for melted plastic, since heat is the usual killer.
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Source wording:Engine - EGR actuator - Data erratic intermittent or incorrect
Deutz SPN 2791 FMI 3EGR actuator: Voltage high / shorted high
The EMR4 sees the output for the EGR actuator (EGR valve) (on the exhaust gas recirculation line between exhaust manifold and intake) at a voltage above normal, as if the circuit is shorted to the battery supply. The controller cannot drive the actuator correctly. Deutz list: KWP code 1758, blink code 415. For this code the controller read the EGR actuator circuit at a voltage above normal, as if the wire or the driver were pulled up to the supply voltage, for instance by a chafed harness touching a live wire. The EGR actuator is the valve that meters recirculated exhaust and sits in the hottest part of the engine.· Shorted highShorted highCheck soonCauses
- Soot sticking the EGR valve plate
- Connector pin touching a live pin
- Output wire shorted to battery positive
- Harness insulation worn through where it rubs on a bracket, letting the wire touch a live supply
Checks
- 1Unplug the EGR actuator (EGR valve): if the code stays, the short is in the harness or the EMR4; if it clears, the part is the shorted one
- 2With the EMR4 unplugged, measure the output wire to battery positive; it should be open
- 3Measure the winding or coil resistance of the part
- 4Inspect the EGR valve for sooting and check it moves freely
- 5With the EMR4 and the EGR actuator unplugged, measure the signal wire against battery positive; it must read open, and any reading means the harness is shorted high.
- 6Check the heat shield and the connector of the EGR actuator for melted plastic, since heat is the usual killer.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Source wording:Engine - EGR actuator - Voltage above normal or shorted to high source
Deutz SPN 2791 FMI 4EGR actuator: Voltage low / shorted low
The EMR4 sees the output for the EGR actuator (EGR valve) (on the exhaust gas recirculation line between exhaust manifold and intake) at a voltage below normal, as if the circuit is shorted to ground. The controller cannot drive the actuator correctly. Deutz list: KWP code 1759, blink code 415. For this code the controller read the EGR actuator circuit at a voltage below normal, as if it were tied to ground, which points to a wire rubbing through on the frame or a part shorted to its housing. The EGR actuator is the valve that meters recirculated exhaust and sits in the hottest part of the engine.· Shorted lowShorted lowCheck soonCauses
- Output wire chafed to ground or the engine block
- Soot sticking the EGR valve plate
- Water in the connector bridging the pins
- Wire pinched against the engine block or frame so the signal is pulled to ground
Checks
- 1Inspect the EGR valve for sooting and check it moves freely
- 2Unplug the EGR actuator (EGR valve): if the code changes, the part is the shorted one; if it stays, look at the harness
- 3Compare commanded and actual EGR position in SerDia while exercising the valve
- 4With the EMR4 unplugged, measure the output wire to ground; it should not be low ohms
- 5Measure the winding resistance of the part and look for a very low value
- 6With the connector unplugged, measure the EGR actuator signal wire against ground; a low resistance means a harness short, while an open reading sends you to the part itself.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Engine - EGR actuator - Voltage below normal or shorted to low source
Deutz SPN 2791 FMI 6EGR actuator: Current high / grounded
The EMR4 sees too much current through the EGR actuator (EGR valve) (on the exhaust gas recirculation line between exhaust manifold and intake). A shorted winding or wiring fault is drawing more current than the controller allows. Deutz list: KWP code 1757, blink code 415. For this code the controller measured too much current in the EGR actuator circuit and switched the driver off to protect itself, typically because of a shorted winding or a wire grounded in the harness. The EGR actuator is the valve that meters recirculated exhaust and sits in the hottest part of the engine.· Shorted lowShorted lowCheck soonCauses
- Wire chafed to ground
- Soot sticking the EGR valve plate
- Winding partly shorted inside the part
- EGR valve plate seized with carbon deposits
- Winding of the coil shorted turn to turn after heat or vibration
Checks
- 1Check the wiring for chafe and for water in the connector
- 2Move the part by hand with the key off to see whether it is seized
- 3Compare commanded and actual EGR position in SerDia while exercising the valve
- 4Inspect the EGR valve for sooting and check it moves freely
- 5Measure the coil resistance of the EGR actuator and compare it with a good one; a value far too low means a shorted winding, and unplugging the part to see whether the code clears shows which side is at fault.
- 6Check the heat shield and the connector of the EGR actuator for melted plastic, since heat is the usual killer.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Engine - EGR actuator - Current above normal or grounded circuit
Deutz SPN 2791 FMI 7EGR actuator: Not responding / out of adjustment
The EMR4 sees the EGR actuator (EGR valve) (on the exhaust gas recirculation line between exhaust manifold and intake) not following its commanded position or movement. The signal is fine; the part itself is not moving as it should. Deutz list: KWP code 1752, blink code 415. For this code the EGR actuator was commanded but did not follow, so the fault is mechanical (sticking, wear or soot) rather than electrical. The EGR actuator is the valve that meters recirculated exhaust and sits in the hottest part of the engine.· Part or controllerPart or controllerCheck soonCauses
- Actuator position sensor drifting
- Soot sticking the EGR valve plate
- EGR valve plate seized with carbon deposits
- Soot, carbon or dried residue binding the moving parts
Checks
- 1Inspect the EGR valve for sooting and check it moves freely
- 2Command it from SerDia and watch actual position against commanded
- 3Compare commanded and actual EGR position in SerDia while exercising the valve
- 4Inspect for soot, oil or foreign matter around the part
- 5Move the EGR actuator by hand with the key off to feel for sticking, play or soot before you test the electrics.
- 6Check the heat shield and the connector of the EGR actuator for melted plastic, since heat is the usual killer.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Source wording:Engine - EGR actuator - Mechanical system not responding or out of adjustment
Deutz SPN 2791 FMI 12EGR actuator: Bad device or component
The EMR4 judges the EGR actuator (EGR valve) (on the exhaust gas recirculation line between exhaust manifold and intake) to be a bad device, meaning the part or its driver electronics no longer respond as a working component. Deutz list: KWP code 384, blink code 415. For this code the EGR actuator reports an internal fault to the controller, so the electronics inside the part have judged themselves defective. The EGR actuator is the valve that meters recirculated exhaust and sits in the hottest part of the engine.· Part or controllerPart or controllerCheck soonCauses
- Soot sticking the EGR valve plate
- Internal failure of the EGR actuator (EGR valve)
- Driver stage in the EMR4 failing
- Electronics inside the part damaged by heat, water or a voltage spike
Checks
- 1Fit a known good EGR actuator (EGR valve) if you can borrow one and see whether the code clears for good
- 2Compare commanded and actual EGR position in SerDia while exercising the valve
- 3Inspect the EGR valve for sooting and check it moves freely
- 4Read the EGR actuator (EGR valve) status in SerDia and run any actuator test
- 5Measure supply voltage and ground at the EGR actuator (EGR valve) connector with the key on to confirm the part is powered
- 6Check supply voltage and ground at the EGR actuator connector under load; if both are good the part itself is the likely culprit and a swap with a known good one confirms it.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Source wording:Engine - EGR actuator - Bad intelligent device or component
Deutz SPN 2791 FMI 13EGR actuator: Out of calibration
The EMR4 reports the EGR actuator (EGR valve) (on the exhaust gas recirculation line between exhaust manifold and intake) as out of calibration. The learned end positions or characteristics no longer match what the controller expects. Deutz list: KWP code 1754, blink code 415. For this code the EGR actuator is out of calibration: its learned end positions no longer match what the controller expects, which usually follows a replacement or a reset. The EGR actuator is the valve that meters recirculated exhaust and sits in the hottest part of the engine.· Part or controllerPart or controllerCheck soonCauses
- Mechanical wear or play shifting the end positions
- Actuator position sensor drifting
- EGR actuator (EGR valve) replaced without a recalibration
- Controller or part replaced without the learn routine being run
Checks
- 1Replace the EGR actuator (EGR valve) if the end-position learn routine in SerDia fails repeatedly
- 2Compare commanded and actual EGR position in SerDia while exercising the valve
- 3Inspect the EGR valve for sooting and check it moves freely
- 4Run the end-position learn or calibration routine in SerDia, if your service tool offers it for the EGR actuator (EGR valve)
- 5Check the EGR actuator (EGR valve) for mechanical play or a loose linkage that shifts its end positions
- 6Run the calibration or learn routine for the EGR actuator in SerDia after the repair and confirm that it completes.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Deutz SPN 2791 FMI 16EGR actuator: Reading too high· moderately severe
The EMR4 sees the EGR actuator (EGR valve) (on the exhaust gas recirculation line between exhaust manifold and intake) above its allowed range at a moderately severe level. The controller treats it as a warning that gets worse if ignored. Deutz list: KWP code 1762, blink code 415. For this code the controller rates the EGR actuator value as moderately above its range, the early step before the most severe level. The EGR actuator is the valve that meters recirculated exhaust and sits in the hottest part of the engine.· Real conditionReal conditionCheck soonCauses
- EGR valve plate seized with carbon deposits
- Failed part or a real condition behind the signal
- Condition rising toward its limit under load
Checks
- 1Read the actual value against the target in SerDia
- 2Check the EGR actuator (EGR valve) moves freely through its range by hand with the key off
- 3Inspect the supply and control wiring of the EGR actuator (EGR valve) for chafe, water and corrosion
- 4Watch the EGR actuator value in SerDia under load to see whether it climbs toward the severe limit.
- 5Check the heat shield and the connector of the EGR actuator for melted plastic, since heat is the usual killer.
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Source wording:Engine - EGR actuator - Data above normal operational range (Moderately severe level)
Deutz SPN 524030 FMI 7EGR actuator: Not responding / out of adjustment
The EMR4 sees the EGR actuator (on the exhaust gas recirculation line between exhaust manifold and intake) not following its commanded position or movement. The signal is fine; the part itself is not moving as it should. Deutz list: KWP code 1440, blink code 815. For this code the EGR actuator was commanded but did not follow, so the fault is mechanical (sticking, wear or soot) rather than electrical. The EGR actuator is the valve that meters recirculated exhaust and sits in the hottest part of the engine.· Part or controllerPart or controllerCheck soonCauses
- EGR valve plate seized with carbon deposits
- Failed part or a real condition behind the signal
- Soot, carbon or dried residue binding the moving parts
Checks
- 1Move the part by hand with the key off to see whether it is stuck
- 2Command it from SerDia and watch actual position against commanded
- 3Inspect for soot, oil or foreign matter around the part
- 4Move the EGR actuator by hand with the key off to feel for sticking, play or soot before you test the electrics.
- 5Check the heat shield and the connector of the EGR actuator for melted plastic, since heat is the usual killer.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Source wording:Engine - EGR actuator - Mechanical system not responding or out of adjustment
Deutz SPN 524031 FMI 13EGR actuator: Out of calibration
The EMR4 reports the EGR actuator (on the exhaust gas recirculation line between exhaust manifold and intake) as out of calibration. The learned end positions or characteristics no longer match what the controller expects. Deutz list: KWP code 1441, blink code 815. For this code the EGR actuator is out of calibration: its learned end positions no longer match what the controller expects, which usually follows a replacement or a reset. The EGR actuator is the valve that meters recirculated exhaust and sits in the hottest part of the engine.· Part or controllerPart or controllerCheck soonCauses
- EGR actuator replaced without a recalibration
- Mechanical wear or play shifting the end positions
- Controller or part replaced without the learn routine being run
Checks
- 1Run the end-position learn or calibration routine in SerDia, if your service tool offers it for the EGR actuator
- 2Check the EGR actuator for mechanical play or a loose linkage that shifts its end positions
- 3Replace the EGR actuator if the end-position learn routine in SerDia fails repeatedly
- 4Run the calibration or learn routine for the EGR actuator in SerDia after the repair and confirm that it completes.
- 5Check the heat shield and the connector of the EGR actuator for melted plastic, since heat is the usual killer.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Deutz SPN 524032 FMI 2EGR actuator: Erratic reading
The EMR4 sees the EGR actuator (on the exhaust gas recirculation line between exhaust manifold and intake) behave erratically against the command, which can mean a sticking part or an intermittent connection. Deutz list: KWP code 1442, blink code 815. For this code the EGR actuator signal is erratic: it jumps or does not agree with what the controller expects, which usually means an intermittent contact. The EGR actuator is the valve that meters recirculated exhaust and sits in the hottest part of the engine.· Erratic or implausibleErratic or implausibleCheck soonCauses
- EGR valve plate seized with carbon deposits
- Intermittent contact in the connector
- Loose pin or damaged wire that makes the signal drop out
Checks
- 1Command the EGR actuator from SerDia and watch actual versus commanded behaviour for lag or dropouts
- 2Wiggle the EGR actuator harness and connector while watching the live status in SerDia for dropouts
- 3Check both connector halves of the EGR actuator for loose, bent or fretted pins
- 4Wiggle the harness at the EGR actuator while watching the live value in SerDia; a jump exposes a loose pin or a chafed wire.
- 5Check the heat shield and the connector of the EGR actuator for melted plastic, since heat is the usual killer.
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Source wording:Engine - EGR actuator - Data erratic intermittent or incorrect
Deutz SPN 524033 FMI 7EGR actuator: Not responding / out of adjustment
The EMR4 sees the EGR actuator (on the exhaust gas recirculation line between exhaust manifold and intake) not following its commanded position or movement. The signal is fine; the part itself is not moving as it should. Deutz list: KWP code 1443, blink code 815. For this code the EGR actuator was commanded but did not follow, so the fault is mechanical (sticking, wear or soot) rather than electrical. The EGR actuator is the valve that meters recirculated exhaust and sits in the hottest part of the engine.· Part or controllerPart or controllerCheck soonCauses
- EGR valve plate seized with carbon deposits
- Failed part or a real condition behind the signal
- Soot, carbon or dried residue binding the moving parts
Checks
- 1Move the part by hand with the key off to see whether it is stuck
- 2Command it from SerDia and watch actual position against commanded
- 3Inspect for soot, oil or foreign matter around the part
- 4Move the EGR actuator by hand with the key off to feel for sticking, play or soot before you test the electrics.
- 5Check the heat shield and the connector of the EGR actuator for melted plastic, since heat is the usual killer.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Source wording:Engine - EGR actuator - Mechanical system not responding or out of adjustment
Throttle valve dynamic current limitation1 code
Deutz SPN 524281 FMI 6Throttle valve dynamic current limitation: Current high / grounded
The EMR4 sees too much current through the throttle valve dynamic current limitation (in the intake path, used by the EMR4 for EGR flow control). A shorted winding or wiring fault is drawing more current than the controller allows. Deutz list: KWP codes 2038 (blink 1124), 2069 (blink 1147). For this code the controller measured too much current in the throttle valve dynamic current limitation circuit and switched the driver off to protect itself, typically because of a shorted winding or a wire grounded in the harness. Dynamic current limitation means the throttle valve motor pulled more current than the limit, usually a stiff flap.· Shorted lowShorted lowCheck soonCauses
- Winding partly shorted inside the part
- Wire chafed to ground
- Throttle flap seized with soot or oil build-up
- Winding of the coil shorted turn to turn after heat or vibration
Checks
- 1Measure the throttle valve dynamic current limitation winding resistance; a low value means it is shorting
- 2Check the wiring for chafe and for water in the connector
- 3Move the part by hand with the key off to see whether it is seized
- 4Measure the coil resistance of the throttle valve dynamic current limitation and compare it with a good one; a value far too low means a shorted winding, and unplugging the part to see whether the code clears shows which side is at fault.
- 5Free the throttle flap shaft from carbon and check that it turns smoothly by hand.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Source wording:Engine - Throttle valve dynamic current limitation - Current above normal or grounded circuit
Shared checks
Checks, in order
- 1Remove the valve and look for carbon build-up; move it by hand with the key off
- 2Measure supply and ground at the valve connector with the key on
- 3Read commanded and actual valve position in SerDia and see where they part
- 4Check the wiring and connector for heat damage next to the exhaust
- 5Compare the fault after cleaning; if it returns at once, suspect the valve or its harness
Causes
- Valve stuck or sluggish with soot or carbon deposits
- Valve motor or position sensor failed from heat
- Supply fuse, relay or ground to the valve open
- Valve connector burnt, corroded or filled with soot
Most common here: part or controller (8 of 23)
Check power and ground at the module connector with the key on, then its fuses.
When to stop
You'll notice: A warning lamp or limited function.
Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.