EF Logo

Deutz · EGR

Deutz EGR and intake throttle valves fault codes

The smart valves that steer exhaust gas recirculation and intake air: the EGR actuator (valve and its position feedback) and the EGR and intake throttle valve. The EMR4 sends each a target position and reads back the position and status.

More about these parts

Each code names the valve and whether its drive, its position signal or its movement failed.

FaultCheckSPN 51FMI 0Deutz · Throttle valve / Throttle valve position
Plug the service tool in hereDiagnosticport, 9-pin

Where to read it

Read the active and stored faults with Deutz SerDia (or the machine maker's diagnostic tool) on the engine diagnostic plug.

What do these codes mean?

Deutz codes SPN 51 FMI 0 to SPN 524281 FMI 6 are all about the eGR and intake throttle valves. The most common failure type is part or controller (8 of 23); none needs an immediate stop. Start with this check: remove the valve and look for carbon build-up; move it by hand with the key off.

How urgent are they?

None of the 23 codes here means stop now; all 23 can wait until the shift ends, but find the cause before the next one.

  • Check soon23

What should I check first?

Remove the valve and look for carbon build-up; move it by hand with the key off

Shared checks

23 of 23

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Throttle valve / Throttle valve position9 codes

    • Deutz SPN 51 FMI 0Throttle valve / Throttle valve position: Reading too high· most severe

      The EMR4 sees the intake throttle valve (in the intake path, used by the EMR4 for EGR flow control) above its allowed range.· Real condition
      Check soon

      Causes

      • Throttle flap seized with soot or oil build-up
      • Valve flap stuck with soot
      • Part driven beyond its limit
      • Actuator connector corroded
      • Condition really above the limit, for example from overload or a blockage

      Checks

      1. 1Inspect the supply and control wiring of the intake throttle valve for chafe, water and corrosion
      2. 2Check the intake throttle valve moves freely through its range by hand with the key off
      3. 3Remove the intake pipe and check the flap moves freely by hand, with the key off
      4. 4Compare commanded and actual valve position in SerDia while sweeping the throttle valve
      5. 5Read the actual value against the target in SerDia
      6. 6Compare the throttle valve / Throttle valve position reading in SerDia with an independent measurement to see whether the high value is real.
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Engine - Throttle valve / Throttle valve position - Data above normal operational range (Most severe level)

    • Deutz SPN 51 FMI 1Throttle valve / Throttle valve position: Reading too low· most severe

      The EMR4 sees the intake throttle valve (in the intake path, used by the EMR4 for EGR flow control) below its allowed range.· Real condition
      Check soon

      Causes

      • Part not reaching its commanded value
      • Throttle flap seized with soot or oil build-up
      • Actuator connector corroded
      • Valve flap stuck with soot
      • Condition really below the limit, for example from a leak or a weak supply

      Checks

      1. 1Read the actual value against the target in SerDia
      2. 2Compare commanded and actual valve position in SerDia while sweeping the throttle valve
      3. 3Inspect the supply and control wiring of the intake throttle valve for chafe, water and corrosion
      4. 4Remove the intake pipe and check the flap moves freely by hand, with the key off
      5. 5Check the part moves through its full travel by hand with the key off
      6. 6Compare the throttle valve / Throttle valve position reading in SerDia with an independent measurement to see whether the low value is real.
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Engine - Throttle valve / Throttle valve position - Data below normal operational range (Most severe level)

    • Deutz SPN 51 FMI 3Throttle valve / Throttle valve position: Voltage high / shorted high

      The EMR4 sees the output for the intake throttle valve (in the intake path, used by the EMR4 for EGR flow control) at a voltage above normal, as if the circuit is shorted to the battery supply.· Shorted high
      Check soon

      Causes

      • Connector pin touching a live pin
      • Output wire shorted to battery positive
      • Intake throttle valve shorted internally
      • Harness insulation worn through where it rubs on a bracket, letting the wire touch a live supply

      Checks

      1. 1Remove the intake pipe and check the flap moves freely by hand, with the key off
      2. 2Measure the winding or coil resistance of the part
      3. 3Compare commanded and actual valve position in SerDia while sweeping the throttle valve
      4. 4With the EMR4 unplugged, measure the output wire to battery positive; it should be open
      5. 5With the EMR4 and the throttle valve / Throttle valve position unplugged, measure the signal wire against battery positive; it must read open, and any reading means the harness is shorted high.
      6. 6Look at the flap through the intake pipe with the key on: it should move and then rest at the commanded angle.
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:Engine - Throttle valve / Throttle valve position - Voltage above normal or shorted to high source

    • Deutz SPN 51 FMI 4Throttle valve / Throttle valve position: Voltage low / shorted low

      The EMR4 sees the output for the intake throttle valve (in the intake path, used by the EMR4 for EGR flow control) at a voltage below normal, as if the circuit is shorted to ground.· Shorted low
      Check soon

      Causes

      • Valve flap stuck with soot
      • Output wire chafed to ground or the engine block
      • Intake throttle valve winding shorted to its housing
      • Water in the connector bridging the pins
      • Wire pinched against the engine block or frame so the signal is pulled to ground

      Checks

      1. 1Measure the winding resistance of the part and look for a very low value
      2. 2Remove the intake pipe and check the flap moves freely by hand, with the key off
      3. 3Compare commanded and actual valve position in SerDia while sweeping the throttle valve
      4. 4Unplug the intake throttle valve: if the code changes, the part is the shorted one; if it stays, look at the harness
      5. 5With the connector unplugged, measure the throttle valve / Throttle valve position signal wire against ground; a low resistance means a harness short, while an open reading sends you to the part itself.
      6. 6Look at the flap through the intake pipe with the key on: it should move and then rest at the commanded angle.
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Engine - Throttle valve / Throttle valve position - Voltage below normal or shorted to low source

    • Deutz SPN 51 FMI 5Throttle valve / Throttle valve position: Current low / open circuit

      The EMR4 sees too little current through the intake throttle valve (in the intake path, used by the EMR4 for EGR flow control), which means the circuit is open.· Open circuit
      Check soon

      Causes

      • Connector left unplugged after earlier work
      • Intake throttle valve winding open
      • Valve flap stuck with soot
      • Broken wire or a pin pushed out of the connector
      • Terminal pushed back or corroded in its connector so the circuit is open

      Checks

      1. 1Remove the intake pipe and check the flap moves freely by hand, with the key off
      2. 2Continuity-test each wire to the matching EMR4 pin
      3. 3Measure the resistance across the intake throttle valve terminals: infinity means an open winding
      4. 4Compare commanded and actual valve position in SerDia while sweeping the throttle valve
      5. 5Inspect both ends of the intake throttle valve circuit (EMR4 plug and part connector) for pins pushed back in the housing
      6. 6Check the continuity of both wires between the EMR4 plug and the throttle valve / Throttle valve position connector, then the coil resistance, to separate a broken wire from a dead coil.
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

      Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

      Source wording:Engine - Throttle valve / Throttle valve position - Current below normal or open circuit

    • Deutz SPN 51 FMI 6Throttle valve / Throttle valve position: Current high / grounded

      The EMR4 sees too much current through the intake throttle valve (in the intake path, used by the EMR4 for EGR flow control).· Shorted low
      Check soon

      Causes

      • Wire chafed to ground
      • Valve flap stuck with soot
      • Throttle flap seized with soot or oil build-up
      • Winding of the coil shorted turn to turn after heat or vibration

      Checks

      1. 1Check the wiring for chafe and for water in the connector
      2. 2Compare commanded and actual valve position in SerDia while sweeping the throttle valve
      3. 3Measure the intake throttle valve winding resistance; a low value means it is shorting
      4. 4Move the part by hand with the key off to see whether it is seized
      5. 5Remove the intake pipe and check the flap moves freely by hand, with the key off
      6. 6Measure the coil resistance of the throttle valve / Throttle valve position and compare it with a good one; a value far too low means a shorted winding, and unplugging the part to see whether the code clears shows which side is at fault.
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Engine - Throttle valve / Throttle valve position - Current above normal or grounded circuit

    • Deutz SPN 51 FMI 7Throttle valve / Throttle valve position: Not responding / out of adjustment

      The EMR4 sees the intake throttle valve (in the intake path, used by the EMR4 for EGR flow control) not following its commanded position or movement.· Part or controller
      Check soon

      Causes

      • Valve flap stuck with soot
      • Actuator connector corroded
      • Throttle flap seized with soot or oil build-up
      • Soot, carbon or dried residue binding the moving parts

      Checks

      1. 1Command it from SerDia and watch actual position against commanded
      2. 2Inspect for soot, oil or foreign matter around the part
      3. 3Remove the intake pipe and check the flap moves freely by hand, with the key off
      4. 4Compare commanded and actual valve position in SerDia while sweeping the throttle valve
      5. 5Move the throttle valve / Throttle valve position by hand with the key off to feel for sticking, play or soot before you test the electrics.
      6. 6Look at the flap through the intake pipe with the key on: it should move and then rest at the commanded angle.
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

      Source wording:Engine - Throttle valve / Throttle valve position - Mechanical system not responding or out of adjustment

    • Deutz SPN 51 FMI 11Throttle valve / Throttle valve position: Root cause not known

      The EMR4 logged a fault on the intake throttle valve (in the intake path, used by the EMR4 for EGR flow control) but could not classify the cause.· Other
      Check soon

      Causes

      • Intermittent wiring fault
      • Failing intake throttle valve
      • Intermittent contact that left no clear electrical signature

      Checks

      1. 1Read the full SerDia fault list; this code often sits next to a clearer one on the intake throttle valve
      2. 2Measure the supply and ground at the intake throttle valve plug with the key on to confirm it is powered
      3. 3Inspect the intake throttle valve plug and harness for chafed insulation, bent pins and moisture
      4. 4Read the freeze frame stored with the throttle valve / Throttle valve position fault and note speed, load and battery voltage at the moment it was logged.
      5. 5Look at the flap through the intake pipe with the key on: it should move and then rest at the commanded angle.
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

    • Deutz SPN 51 FMI 12Throttle valve / Throttle valve position: Bad device or component

      The EMR4 judges the intake throttle valve (in the intake path, used by the EMR4 for EGR flow control) to be a bad device, meaning the part or its driver electronics no longer respond as a working component.· Part or controller
      Check soon

      Causes

      • Water or soot inside the part
      • Internal failure of the intake throttle valve
      • Driver stage in the EMR4 failing
      • Electronics inside the part damaged by heat, water or a voltage spike

      Checks

      1. 1Read the intake throttle valve status in SerDia and run any actuator test
      2. 2Remove the intake pipe and check the flap moves freely by hand, with the key off
      3. 3Measure supply voltage and ground at the intake throttle valve connector with the key on to confirm the part is powered
      4. 4Compare commanded and actual valve position in SerDia while sweeping the throttle valve
      5. 5Check supply voltage and ground at the throttle valve / Throttle valve position connector under load; if both are good the part itself is the likely culprit and a swap with a known good one confirms it.
      6. 6Look at the flap through the intake pipe with the key on: it should move and then rest at the commanded angle.
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

      Source wording:Engine - Throttle valve / Throttle valve position - Bad intelligent device or component

  • EGR actuator13 codes

    • Deutz SPN 2791 FMI 0EGR actuator: Reading too high· most severe

      The EMR4 sees the EGR actuator (EGR valve) (on the exhaust gas recirculation line between exhaust manifold and intake) above its allowed range.· Real condition
      Check soon

      Causes

      • Actuator position sensor drifting
      • EGR valve plate seized with carbon deposits
      • Soot sticking the EGR valve plate
      • Condition really above the limit, for example from overload or a blockage

      Checks

      1. 1Compare commanded and actual EGR position in SerDia while exercising the valve
      2. 2Read the actual value against the target in SerDia
      3. 3Inspect the EGR valve for sooting and check it moves freely
      4. 4Check the EGR actuator (EGR valve) moves freely through its range by hand with the key off
      5. 5Compare the EGR actuator reading in SerDia with an independent measurement to see whether the high value is real.
      6. 6Check the heat shield and the connector of the EGR actuator for melted plastic, since heat is the usual killer.
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Engine - EGR actuator - Data above normal operational range (Most severe level)

    • Deutz SPN 2791 FMI 2EGR actuator: Erratic reading

      The EMR4 sees the EGR actuator (EGR valve) (on the exhaust gas recirculation line between exhaust manifold and intake) behave erratically against the command, which can mean a sticking part or an intermittent connection.· Erratic or implausible
      Check soon

      Causes

      • Actuator position sensor drifting
      • EGR valve plate seized with carbon deposits
      • Intermittent contact in the connector
      • Loose pin or damaged wire that makes the signal drop out

      Checks

      1. 1Compare commanded and actual EGR position in SerDia while exercising the valve
      2. 2Inspect the EGR valve for sooting and check it moves freely
      3. 3Command the EGR actuator (EGR valve) from SerDia and watch actual versus commanded behaviour for lag or dropouts
      4. 4Wiggle the EGR actuator (EGR valve) harness and connector while watching the live status in SerDia for dropouts
      5. 5Wiggle the harness at the EGR actuator while watching the live value in SerDia; a jump exposes a loose pin or a chafed wire.
      6. 6Check the heat shield and the connector of the EGR actuator for melted plastic, since heat is the usual killer.
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Engine - EGR actuator - Data erratic intermittent or incorrect

    • Deutz SPN 2791 FMI 3EGR actuator: Voltage high / shorted high

      The EMR4 sees the output for the EGR actuator (EGR valve) (on the exhaust gas recirculation line between exhaust manifold and intake) at a voltage above normal, as if the circuit is shorted to the battery supply.· Shorted high
      Check soon

      Causes

      • Soot sticking the EGR valve plate
      • Connector pin touching a live pin
      • Output wire shorted to battery positive
      • Harness insulation worn through where it rubs on a bracket, letting the wire touch a live supply

      Checks

      1. 1Unplug the EGR actuator (EGR valve): if the code stays, the short is in the harness or the EMR4; if it clears, the part is the shorted one
      2. 2With the EMR4 unplugged, measure the output wire to battery positive; it should be open
      3. 3Measure the winding or coil resistance of the part
      4. 4Inspect the EGR valve for sooting and check it moves freely
      5. 5With the EMR4 and the EGR actuator unplugged, measure the signal wire against battery positive; it must read open, and any reading means the harness is shorted high.
      6. 6Check the heat shield and the connector of the EGR actuator for melted plastic, since heat is the usual killer.
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:Engine - EGR actuator - Voltage above normal or shorted to high source

    • Deutz SPN 2791 FMI 4EGR actuator: Voltage low / shorted low

      The EMR4 sees the output for the EGR actuator (EGR valve) (on the exhaust gas recirculation line between exhaust manifold and intake) at a voltage below normal, as if the circuit is shorted to ground.· Shorted low
      Check soon

      Causes

      • Output wire chafed to ground or the engine block
      • Soot sticking the EGR valve plate
      • Water in the connector bridging the pins
      • Wire pinched against the engine block or frame so the signal is pulled to ground

      Checks

      1. 1Inspect the EGR valve for sooting and check it moves freely
      2. 2Unplug the EGR actuator (EGR valve): if the code changes, the part is the shorted one; if it stays, look at the harness
      3. 3Compare commanded and actual EGR position in SerDia while exercising the valve
      4. 4With the EMR4 unplugged, measure the output wire to ground; it should not be low ohms
      5. 5Measure the winding resistance of the part and look for a very low value
      6. 6With the connector unplugged, measure the EGR actuator signal wire against ground; a low resistance means a harness short, while an open reading sends you to the part itself.
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Engine - EGR actuator - Voltage below normal or shorted to low source

    • Deutz SPN 2791 FMI 6EGR actuator: Current high / grounded

      The EMR4 sees too much current through the EGR actuator (EGR valve) (on the exhaust gas recirculation line between exhaust manifold and intake).· Shorted low
      Check soon

      Causes

      • Wire chafed to ground
      • Soot sticking the EGR valve plate
      • Winding partly shorted inside the part
      • EGR valve plate seized with carbon deposits
      • Winding of the coil shorted turn to turn after heat or vibration

      Checks

      1. 1Check the wiring for chafe and for water in the connector
      2. 2Move the part by hand with the key off to see whether it is seized
      3. 3Compare commanded and actual EGR position in SerDia while exercising the valve
      4. 4Inspect the EGR valve for sooting and check it moves freely
      5. 5Measure the coil resistance of the EGR actuator and compare it with a good one; a value far too low means a shorted winding, and unplugging the part to see whether the code clears shows which side is at fault.
      6. 6Check the heat shield and the connector of the EGR actuator for melted plastic, since heat is the usual killer.
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Engine - EGR actuator - Current above normal or grounded circuit

    • Deutz SPN 2791 FMI 7EGR actuator: Not responding / out of adjustment

      The EMR4 sees the EGR actuator (EGR valve) (on the exhaust gas recirculation line between exhaust manifold and intake) not following its commanded position or movement.· Part or controller
      Check soon

      Causes

      • Actuator position sensor drifting
      • Soot sticking the EGR valve plate
      • EGR valve plate seized with carbon deposits
      • Soot, carbon or dried residue binding the moving parts

      Checks

      1. 1Inspect the EGR valve for sooting and check it moves freely
      2. 2Command it from SerDia and watch actual position against commanded
      3. 3Compare commanded and actual EGR position in SerDia while exercising the valve
      4. 4Inspect for soot, oil or foreign matter around the part
      5. 5Move the EGR actuator by hand with the key off to feel for sticking, play or soot before you test the electrics.
      6. 6Check the heat shield and the connector of the EGR actuator for melted plastic, since heat is the usual killer.
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

      Source wording:Engine - EGR actuator - Mechanical system not responding or out of adjustment

    • Deutz SPN 2791 FMI 12EGR actuator: Bad device or component

      The EMR4 judges the EGR actuator (EGR valve) (on the exhaust gas recirculation line between exhaust manifold and intake) to be a bad device, meaning the part or its driver electronics no longer respond as a working component.· Part or controller
      Check soon

      Causes

      • Soot sticking the EGR valve plate
      • Internal failure of the EGR actuator (EGR valve)
      • Driver stage in the EMR4 failing
      • Electronics inside the part damaged by heat, water or a voltage spike

      Checks

      1. 1Fit a known good EGR actuator (EGR valve) if you can borrow one and see whether the code clears for good
      2. 2Compare commanded and actual EGR position in SerDia while exercising the valve
      3. 3Inspect the EGR valve for sooting and check it moves freely
      4. 4Read the EGR actuator (EGR valve) status in SerDia and run any actuator test
      5. 5Measure supply voltage and ground at the EGR actuator (EGR valve) connector with the key on to confirm the part is powered
      6. 6Check supply voltage and ground at the EGR actuator connector under load; if both are good the part itself is the likely culprit and a swap with a known good one confirms it.
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

      Source wording:Engine - EGR actuator - Bad intelligent device or component

    • Deutz SPN 2791 FMI 13EGR actuator: Out of calibration

      The EMR4 reports the EGR actuator (EGR valve) (on the exhaust gas recirculation line between exhaust manifold and intake) as out of calibration.· Part or controller
      Check soon

      Causes

      • Mechanical wear or play shifting the end positions
      • Actuator position sensor drifting
      • EGR actuator (EGR valve) replaced without a recalibration
      • Controller or part replaced without the learn routine being run

      Checks

      1. 1Replace the EGR actuator (EGR valve) if the end-position learn routine in SerDia fails repeatedly
      2. 2Compare commanded and actual EGR position in SerDia while exercising the valve
      3. 3Inspect the EGR valve for sooting and check it moves freely
      4. 4Run the end-position learn or calibration routine in SerDia, if your service tool offers it for the EGR actuator (EGR valve)
      5. 5Check the EGR actuator (EGR valve) for mechanical play or a loose linkage that shifts its end positions
      6. 6Run the calibration or learn routine for the EGR actuator in SerDia after the repair and confirm that it completes.
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

    • Deutz SPN 2791 FMI 16EGR actuator: Reading too high· moderately severe

      The EMR4 sees the EGR actuator (EGR valve) (on the exhaust gas recirculation line between exhaust manifold and intake) above its allowed range at a moderately severe level.· Real condition
      Check soon

      Causes

      • EGR valve plate seized with carbon deposits
      • Failed part or a real condition behind the signal
      • Condition rising toward its limit under load

      Checks

      1. 1Read the actual value against the target in SerDia
      2. 2Check the EGR actuator (EGR valve) moves freely through its range by hand with the key off
      3. 3Inspect the supply and control wiring of the EGR actuator (EGR valve) for chafe, water and corrosion
      4. 4Watch the EGR actuator value in SerDia under load to see whether it climbs toward the severe limit.
      5. 5Check the heat shield and the connector of the EGR actuator for melted plastic, since heat is the usual killer.
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Engine - EGR actuator - Data above normal operational range (Moderately severe level)

    • Deutz SPN 524030 FMI 7EGR actuator: Not responding / out of adjustment

      The EMR4 sees the EGR actuator (on the exhaust gas recirculation line between exhaust manifold and intake) not following its commanded position or movement.· Part or controller
      Check soon

      Causes

      • EGR valve plate seized with carbon deposits
      • Failed part or a real condition behind the signal
      • Soot, carbon or dried residue binding the moving parts

      Checks

      1. 1Move the part by hand with the key off to see whether it is stuck
      2. 2Command it from SerDia and watch actual position against commanded
      3. 3Inspect for soot, oil or foreign matter around the part
      4. 4Move the EGR actuator by hand with the key off to feel for sticking, play or soot before you test the electrics.
      5. 5Check the heat shield and the connector of the EGR actuator for melted plastic, since heat is the usual killer.
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

      Source wording:Engine - EGR actuator - Mechanical system not responding or out of adjustment

    • Deutz SPN 524031 FMI 13EGR actuator: Out of calibration

      The EMR4 reports the EGR actuator (on the exhaust gas recirculation line between exhaust manifold and intake) as out of calibration.· Part or controller
      Check soon

      Causes

      • EGR actuator replaced without a recalibration
      • Mechanical wear or play shifting the end positions
      • Controller or part replaced without the learn routine being run

      Checks

      1. 1Run the end-position learn or calibration routine in SerDia, if your service tool offers it for the EGR actuator
      2. 2Check the EGR actuator for mechanical play or a loose linkage that shifts its end positions
      3. 3Replace the EGR actuator if the end-position learn routine in SerDia fails repeatedly
      4. 4Run the calibration or learn routine for the EGR actuator in SerDia after the repair and confirm that it completes.
      5. 5Check the heat shield and the connector of the EGR actuator for melted plastic, since heat is the usual killer.
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

    • Deutz SPN 524032 FMI 2EGR actuator: Erratic reading

      The EMR4 sees the EGR actuator (on the exhaust gas recirculation line between exhaust manifold and intake) behave erratically against the command, which can mean a sticking part or an intermittent connection.· Erratic or implausible
      Check soon

      Causes

      • EGR valve plate seized with carbon deposits
      • Intermittent contact in the connector
      • Loose pin or damaged wire that makes the signal drop out

      Checks

      1. 1Command the EGR actuator from SerDia and watch actual versus commanded behaviour for lag or dropouts
      2. 2Wiggle the EGR actuator harness and connector while watching the live status in SerDia for dropouts
      3. 3Check both connector halves of the EGR actuator for loose, bent or fretted pins
      4. 4Wiggle the harness at the EGR actuator while watching the live value in SerDia; a jump exposes a loose pin or a chafed wire.
      5. 5Check the heat shield and the connector of the EGR actuator for melted plastic, since heat is the usual killer.
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Engine - EGR actuator - Data erratic intermittent or incorrect

    • Deutz SPN 524033 FMI 7EGR actuator: Not responding / out of adjustment

      The EMR4 sees the EGR actuator (on the exhaust gas recirculation line between exhaust manifold and intake) not following its commanded position or movement.· Part or controller
      Check soon

      Causes

      • EGR valve plate seized with carbon deposits
      • Failed part or a real condition behind the signal
      • Soot, carbon or dried residue binding the moving parts

      Checks

      1. 1Move the part by hand with the key off to see whether it is stuck
      2. 2Command it from SerDia and watch actual position against commanded
      3. 3Inspect for soot, oil or foreign matter around the part
      4. 4Move the EGR actuator by hand with the key off to feel for sticking, play or soot before you test the electrics.
      5. 5Check the heat shield and the connector of the EGR actuator for melted plastic, since heat is the usual killer.
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

      Source wording:Engine - EGR actuator - Mechanical system not responding or out of adjustment

  • Throttle valve dynamic current limitation1 code

    • Deutz SPN 524281 FMI 6Throttle valve dynamic current limitation: Current high / grounded

      The EMR4 sees too much current through the throttle valve dynamic current limitation (in the intake path, used by the EMR4 for EGR flow control).· Shorted low
      Check soon

      Causes

      • Winding partly shorted inside the part
      • Wire chafed to ground
      • Throttle flap seized with soot or oil build-up
      • Winding of the coil shorted turn to turn after heat or vibration

      Checks

      1. 1Measure the throttle valve dynamic current limitation winding resistance; a low value means it is shorting
      2. 2Check the wiring for chafe and for water in the connector
      3. 3Move the part by hand with the key off to see whether it is seized
      4. 4Measure the coil resistance of the throttle valve dynamic current limitation and compare it with a good one; a value far too low means a shorted winding, and unplugging the part to see whether the code clears shows which side is at fault.
      5. 5Free the throttle flap shaft from carbon and check that it turns smoothly by hand.
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Engine - Throttle valve dynamic current limitation - Current above normal or grounded circuit

Shared checks

Checks, in order

  1. 1Remove the valve and look for carbon build-up; move it by hand with the key off
  2. 2Measure supply and ground at the valve connector with the key on
  3. 3Read commanded and actual valve position in SerDia and see where they part
  4. 4Check the wiring and connector for heat damage next to the exhaust
  5. 5Compare the fault after cleaning; if it returns at once, suspect the valve or its harness

Causes

  • Valve stuck or sluggish with soot or carbon deposits
  • Valve motor or position sensor failed from heat
  • Supply fuse, relay or ground to the valve open
  • Valve connector burnt, corroded or filled with soot

Most common here: part or controller (8 of 23)

Check power and ground at the module connector with the key on, then its fuses.

When to stop

You'll notice: A warning lamp or limited function.

Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.