Deutz EGR sensors: differential pressure, temperature and mass flow fault codes

The sensors the EMR4 uses to measure recirculated exhaust gas. The differential pressure sensor across the venturi (SPN 411), the EGR temperature sensors before and after the cooler, and the EGR and intake air mass flow value (SPN 132).

More about these parts

Each code names the sensor and whether its signal is out of range, shorted, open or implausible.

FaultCheckSPN 411FMI 0Deutz · EGR differential pressure
Plug the service tool in hereDiagnosticport, 9-pin

Where to read it

Read the active and stored faults with Deutz SerDia (or the machine maker's diagnostic tool) on the engine diagnostic plug.

What do these codes mean?

Deutz codes SPN 132 FMI 11 to SPN 523960 FMI 1 are all about the eGR sensors: differential pressure, temperature and mass flow. The most common failure type is real condition (5 of 14); none needs an immediate stop. Start with this check: blow out the differential pressure hoses and check they run to the right measuring points.

How urgent are they?

None of the 14 codes here means stop now; all 14 can wait until the shift ends, but find the cause before the next one.

  • Check soon14

What should I check first?

Blow out the differential pressure hoses and check they run to the right measuring points

Shared checks

14 of 14

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Air mass1 code

    • Deutz SPN 132 FMI 11Air mass: Root cause not known

      The EMR4 logged a fault on the air mass (calculated by the EMR4 from the air path sensors) but could not pin down the cause.· Other
      Check soon

      Causes

      • Intermittent wiring fault that has not stayed long enough to be classified
      • Failing part or a real condition the controller flagged
      • Air intake leak or restriction that makes the real air mass differ from the model
      • Charge air, ambient or air mass related sensor reading wrongly

      Checks

      1. 1Read the full SerDia fault list; this code often appears next to a clearer one
      2. 2Inspect the connector and harness for chafed insulation, bent pins and moisture
      3. 3Compare the air mass with the charge air pressure and temperature in SerDia at a steady load
      4. 4Check the air filter, intake hoses and clamps for leaks and restrictions
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

  • EGR differential pressure5 codes

    • Deutz SPN 411 FMI 0EGR differential pressure: Reading too high· most severe

      The EGR differential pressure sensor (on the EGR cooler or venturi, connected by two small pressure hoses) reports a value above the allowed range.· Real condition
      Check soon

      Causes

      • A blocked downstream hose or heavy soot in the EGR path can give a genuine high differential reading
      • Hose or port feeding the sensor blocked with dirt
      • EGR differential pressure sensor drifting high or reading with an offset

      Checks

      1. 1Check the real value against a mechanical gauge or second reading before touching the EGR differential pressure sensor
      2. 2Inspect the sensor port or hose for restriction
      3. 3Compare with its neighbouring sensors in SerDia to see whether only this value is off
      4. 4Inspect the EGR cooler and pipe for soot build-up that changes the differential pressure
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Engine - EGR differential pressure - Data above normal operational range (Most severe level)

      Full page for SPN 411 FMI 0
    • Deutz SPN 411 FMI 2EGR differential pressure: Erratic reading

      The EMR4 sees the EGR differential pressure sensor (on the EGR cooler or venturi, connected by two small pressure hoses) signal jump or disagree with other values.· Erratic or implausible
      Check soon

      Causes

      • Intermittent contact in the connector
      • EGR differential pressure sensor on its way out
      • Harness chafed against a bracket in a spot that only touches under vibration
      • Sensor hoses swapped or cracked after EGR work

      Checks

      1. 1Inspect the connector for loose pins, bent terminals and moisture
      2. 2Blow out the sensor hoses and check they run to the correct EGR measuring points without kinks or soot plugs
      3. 3Watch the EGR differential pressure sensor value in SerDia while wiggling the connector and harness
      4. 4Inspect the EGR cooler and pipe for soot build-up that changes the differential pressure
      5. 5Check the 5 V reference for dips while the fault shows
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Engine - EGR differential pressure - Data erratic intermittent or incorrect

    • Deutz SPN 411 FMI 3EGR differential pressure: Voltage high / shorted high

      The EMR4 reads the EGR differential pressure sensor (on the EGR cooler or venturi, connected by two small pressure hoses) signal above its valid 0.5 to 4.5 V window.· Shorted high
      Check soon

      Causes

      • Soot-clogged or kinked pressure hose to the EGR venturi
      • Open ground return wire, which pushes the signal up to the reference
      • Signal wire touching 5 V or battery in the harness

      Checks

      1. 1With the sensor unplugged, measure the signal pin; battery voltage there means a short to supply
      2. 2Compare the EGR differential pressure sensor reading in SerDia with key on and engine off against the value you expect at rest
      3. 3Check continuity of the sensor ground wire back to the EMR4 pin
      4. 4Fit a known good EGR differential pressure sensor temporarily, if you have one, and see whether the reading moves back into range
      5. 5Key on: measure the 5 V reference at the EGR differential pressure sensor plug between supply and ground; 5 V present means the supply side is fine
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:Engine - EGR differential pressure - Voltage above normal or shorted to high source

    • Deutz SPN 411 FMI 4EGR differential pressure: Voltage low / shorted low

      The EMR4 reads the EGR differential pressure sensor (on the EGR cooler or venturi, connected by two small pressure hoses) signal below its valid 0.5 to 4.5 V window.· Shorted low
      Check soon

      Causes

      • Signal wire rubbed through to ground
      • 5 V reference lost: open supply wire or a short on the shared 5 V line
      • Soot-clogged or kinked pressure hose to the EGR venturi

      Checks

      1. 1With the sensor unplugged, measure resistance from the signal pin to ground; it should not be near zero
      2. 2Key on: measure the 5 V reference at the EGR differential pressure sensor plug; no reference means open supply wire or another sensor on that line pulling it down
      3. 3Unplug other sensors sharing the 5 V line one at a time to see whether the reference comes back
      4. 4Fit a known good EGR differential pressure sensor temporarily, if you have one, and see whether the reading moves back into range
      5. 5Compare the EGR differential pressure sensor reading in SerDia with key on and engine off against the value you expect at rest
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Engine - EGR differential pressure - Voltage below normal or shorted to low source

    • Deutz SPN 411 FMI 11EGR differential pressure: Root cause not known

      The EMR4 logged a fault on the EGR differential pressure sensor (on the EGR cooler or venturi, connected by two small pressure hoses) but could not classify the cause.· Other
      Check soon

      Causes

      • Failing EGR differential pressure sensor
      • Soot-clogged or kinked pressure hose to the EGR venturi
      • Intermittent wiring fault that did not stay long enough to be classified

      Checks

      1. 1Inspect the EGR differential pressure sensor connector and the harness run for chafed insulation, bent pins and moisture
      2. 2Blow out the sensor hoses and check they run to the correct EGR measuring points without kinks or soot plugs
      3. 3Inspect the EGR cooler and pipe for soot build-up that changes the differential pressure
      4. 4Measure 5 V supply and signal voltage at the sensor plug with the key on
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Read the code with the service tool and note which other codes are active with it.

      Good: Codes that appear together usually share one cause - start with the wiring they share.

  • EGR temperature sensor2 codes

    • Deutz SPN 412 FMI 3EGR temperature sensor: Voltage high / shorted high

      The EMR4 reads the EGR temperature sensor (in the exhaust gas recirculation line after the EGR cooler) at a voltage above its valid window.· Shorted high
      Check soon

      Causes

      • Open circuit: broken wire, pushed-out pin or an unplugged connector at the EGR temperature sensor
      • Sensor element failed open, so its resistance stays very high at any temperature
      • Signal wire touching a supply voltage somewhere in the harness

      Checks

      1. 1Unplug the EGR temperature sensor and measure its resistance across the two pins; an NTC that reads open at room temperature is finished
      2. 2Bridge the two harness pins with a jumper wire with the key on; the code should change to the voltage-below-normal one if the harness is sound
      3. 3With the sensor unplugged and key on, check the signal pin for battery voltage, which would mean a short to supply
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

      Good: Open circuit (OL) between them. Any low reading is the short.

      Source wording:Engine - EGR temperature sensor - Voltage above normal or shorted to high source

    • Deutz SPN 412 FMI 4EGR temperature sensor: Voltage low / shorted low

      The EMR4 reads the EGR temperature sensor (in the exhaust gas recirculation line after the EGR cooler) at a voltage below its valid window.· Shorted low
      Check soon

      Causes

      • Signal wire rubbed through to the engine block or frame
      • Sensor element shorted internally, so it reads as extremely hot
      • Water bridging the pins inside the EGR temperature sensor connector

      Checks

      1. 1Unplug the EGR temperature sensor with the key on: if the code flips to the voltage-above-normal one, the harness is fine and the sensor is the shorted part
      2. 2With the EMR4 unplugged, measure resistance from the signal pin to ground; anything but open points to a short in the wire
      3. 3Measure the EGR temperature sensor resistance and compare it with its temperature; a very low value means the element is shorted
      ControllerPartSupplySignalGround
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

      Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

      Source wording:Engine - EGR temperature sensor - Voltage below normal or shorted to low source

  • EGR mass flow4 codes

    • Deutz SPN 2659 FMI 0EGR mass flow: Reading too high· most severe

      The EMR4 rates the EGR mass flow (in the EMR4 air path model, derived from the air and EGR sensors) as above its allowed operating range, at the most severe level.· Real condition
      Check soon

      Causes

      • The monitored condition is really above its limit, for example from overload or a blockage
      • Signal or part drifting high with age

      Checks

      1. 1Read the EGR mass flow value in SerDia and compare it with an independent measurement before replacing parts
      2. 2Look for the real cause of an excessive value, such as a restriction or an overloaded function
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Engine - EGR mass flow - Data above normal operational range (Most severe level)

    • Deutz SPN 2659 FMI 1EGR mass flow: Reading too low· most severe

      The EMR4 rates the EGR mass flow (in the EMR4 air path model, derived from the air and EGR sensors) as below its allowed operating range, at the most severe level.· Real condition
      Check soon

      Causes

      • The monitored condition is really below its limit, for example a leak, a blockage or a part not working
      • Signal or part drifting low with age

      Checks

      1. 1Read the EGR mass flow value in SerDia and compare it with an independent measurement before replacing parts
      2. 2Look for the real cause of a low value, such as a leak, a blocked line or a weak supply
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Engine - EGR mass flow - Data below normal operational range (Most severe level)

    • Deutz SPN 2659 FMI 2EGR mass flow: Erratic reading

      The EMR4 sees the EGR mass flow (in the EMR4 air path model, derived from the air and EGR sensors) erratic, intermittent or implausible.· Erratic or implausible
      Check soon

      Causes

      • Intermittent contact in a connector or a pin with fretting
      • Harness chafed where it moves with vibration

      Checks

      1. 1Watch the EGR mass flow value in SerDia while wiggling the harness and connector and note when it jumps
      2. 2Compare it with a related value, since a lone odd reading points at the circuit or part itself
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Watch the live value on the service tool while you flex the harness and tap the connector.

      Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

      Source wording:Engine - EGR mass flow - Data erratic intermittent or incorrect

    • Deutz SPN 2659 FMI 12EGR mass flow: Bad device or component

      The EMR4 judges the EGR mass flow (in the EMR4 air path model, derived from the air and EGR sensors) to be a bad device.· Part or controller
      Check soon

      Causes

      • Internal failure of the part or its electronics
      • Water, soot or dirt inside the part

      Checks

      1. 1Read the EGR mass flow status in SerDia and run any available actuator or component test
      2. 2Check supply voltage and ground at the connector with the key on to confirm it is powered
      ControllerPartSupplySignalGround?
      Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

      Meter test

      Check power and ground at the module connector with the key on, then its fuses.

      Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

      Source wording:Engine - EGR mass flow - Bad intelligent device or component

  • EGR temperature after EGR cooler2 codes

    • Deutz SPN 523960 FMI 0EGR temperature after EGR cooler: Reading too high· most severe

      The EGR temperature after the EGR cooler (downstream of the EGR cooler in the recirculation path) reports a temperature above the allowed operating range.· Real condition
      Check soon

      Causes

      • Cooler bypass flap not moving
      • Sensor drifting low in resistance with age
      • Partial short or wet connector lowering the EGR temperature after the EGR cooler resistance so it reads hot

      Checks

      1. 1Check the real temperature with an infrared thermometer or mechanical gauge before touching the EGR temperature after the EGR cooler
      2. 2Compare EGR temperature after the cooler with coolant temperature; the gap should shrink at steady load
      3. 3Check coolant flow through the EGR cooler and look for a coolant hose that is kinked or blocked
      4. 4Check the connector pins for moisture and corrosion, which can pull a reading hot
      5. 5Look in SerDia at the EGR temperature after the EGR cooler reading next to a neighbouring temperature; a lone hot value points at the sensor
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Engine - EGR temperature after EGR cooler - Data above normal operational range (Most severe level)

    • Deutz SPN 523960 FMI 1EGR temperature after EGR cooler: Reading too low· most severe

      The EGR temperature after the EGR cooler (downstream of the EGR cooler in the recirculation path) reports a temperature below the allowed range.· Real condition
      Check soon

      Causes

      • A reading far below the plausible window means the sensor or its wiring is shorted
      • Cooler bypass flap not moving
      • Sensor drifting high in resistance after heat cycles

      Checks

      1. 1Compare the EGR temperature after the EGR cooler value in SerDia with a neighbouring temperature; if only this one is cold the circuit is suspect
      2. 2Compare EGR temperature after the cooler with coolant temperature; the gap should shrink at steady load
      3. 3Measure voltage drop across the connector with the engine running to find a high-resistance joint
      4. 4Measure the real temperature with a second thermometer once the engine has warmed up
      allowed rangetime
      The reading against the band the controller allows.

      Meter test

      Check the real value with a separate gauge or thermometer before blaming the sensor.

      Good: If the gauge agrees with the display, fix the machine, not the sensor.

      Source wording:Engine - EGR temperature after EGR cooler - Data below normal operational range (Most severe level)

Shared checks

Checks, in order

  1. 1Blow out the differential pressure hoses and check they run to the right measuring points
  2. 2Read the EGR temperatures and the flow value in SerDia and compare them with the engine state
  3. 3Inspect the EGR cooler and pipe for soot build-up
  4. 4Inspect each sensor connector near the exhaust for heat damage and moisture

Causes

  • Soot-clogged or kinked pressure hose to the EGR venturi, or hoses swapped after work
  • EGR cooler or pipe fouled so the readings drift
  • Temperature sensor in the hot exhaust gas with burnt wiring
  • Fault in a sensor, its 5 V supply or its ground wire

Most common here: real condition (5 of 14)

Check the real value with a separate gauge or thermometer before blaming the sensor.

When to stop

You'll notice: A warning lamp or limited function.

Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.